GelCap SL. GelCap SL splice cover kits quickly and con-veniently insulate, seal, and protect stub splice connections up to 1000 volts.

Similar documents
LOW VOLTAGE SPLICES & TAPS

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

HVS S 15kV Class

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

C Electrical Connection Kit

State of the Art in Splicing and Terminating Power Cables. Patrick Lyons Electric Power Sales, Inc.

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

RayClic Connection System

ecolor Graze Powercore Linear LED surface light for wall washing and grazing

SOLARLOK Interconnection System Installation Manual

Seal Kits for BUDI Enclosures

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Model 9001, Alarm

Instruction Manual Magcoder HS35 Hollow Shaft Encoder

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

User s Manual and Operating Instructions

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

Platen Heater Pad Replacement

Installation Guide. For Model: COS52OSB5CR READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE. net weight of fan: lb (9.9 kg) PRINTED IN CHINA

Model 9001, Alarm

HVS S Splice Series

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL

The Escalade OWNER S MANUAL. Ceiling Fan. Model No. FP2320** READ AND SAVE THESE INSTRUCTIONS. Net Weight 38 lbs. or 17.3 kg.

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

F.P.O. Installation Guide. For Placement Only

Raychem Heating System

PRO Series Energy Star Ceiling Fan Owner's Manual

G3/8" DIN ISO 228 THREAD SHOULDER AND DUST CAP MATING SURFACE. STYLE H ESCUTCHEON (SEPARATELY ORDERED) 85 mm DIA. (3-3/8")

Ceiling Fan Ow n e r s Manual

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

ST. KITTS CEILING FAN

XT Series Thermostats

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Ribbon Breakout Kit Installation Instructions

CEILING FAN OWNER'S MANUAL

C A Heating Cable Gland Kit

STEAMPRO. Steam Generator Troubleshooting and Service Guide

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER S MANUAL

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

READ AND SAVE THESE INSTRUCTIONS

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

CEILING FAN OWNER S MANUAL

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

Roof Mounting System. Installation Manual. Standard (XRS) and Light (XRL) Rails with Integrated Grounding *ETL Listed Per UL Edition v1.

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

Table of Contents Important Safeguards 2 Introduction 3 Installation 4 Operation 5 Cleaning Pattern 5 Automatic Shutoff and Removal 6 Maintenance 6

Roof Mounting System. Installation Manual. Light Rail (XRL) 2013 Edition v1.3. Solar Mounting Made Simple

Sound Cover [ , , , ]

Florentine IV 56 in Ceiling Fan Owner s Manual Florentine IV Ventilador de Techo de 1,42 m Manual del Propietario

Hydraulic Crimping Head, PN

CEILING FAN OWNER'S MANUAL

Oahu Showerspa Model #1035 Owner's Manual

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

AMP SUPERSEAL 1.5 SERIES Connectors

TUB AND SHOWER FAUCET

Installation & Operation Manual for WarmlyYours Towel Warmers

Lifetime Limited Warranty

PRO SERIES II Ceiling Fan Owner's Manual

CEILING FAN OWNER'S MANUAL

569, 570, 571, 572 Series

569, 570, 571, 572 Series

Cable Actuated Sensor Industrial Incremental Encoder Output

FOSC. Fiber Optic System Technology. Fiber Optic Splice Closures (FOSC-400)

ITEM # SAIL STREAM CEILING FAN MODEL #40048

Quick Reference Guide Barrier Strips

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC015 - AC016 - AC018

CEILING FAN OWNER'S MANUAL

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

Retro-DWS Internal Heating Cable System for Non-Pressurized Sewer and Waste Drain Pipes

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

Grab-It & Steam-It. User s Guide. Powerful, Lightweight & Durable Power Broom & Steam Mop. Important!

Ozone + UV Sanitation

Installation & Operation Manual for WarmlyYours Towel Warmers

Lifetime Limited Warranty

Hydraulic Crimping Head, PN 69069

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

CEILING FAN OWNER'S MANUAL

Lifetime Limited Warranty

Transcription:

Cold-Applied Splices GelCap SL Stub splice cover kit with connector for use with street lighting (1000 V) 34 Tyco Electronics GelCap SL splice cover kits provide quick installation, dependable performance, and easy reentry for street lighting connections, but they have many other uses. GelCap SL splice cover kits quickly and con-veniently insulate, seal, and protect stub splice connections up to 1000 volts. PowerGel sealant technology: The GelCap SL splice cover kits feature revolutionary PowerGel sealant which provides an excellent moisture seal over a wide temperature range (-40 C to 105 C). Innovative cap design and material: The specially formulated material provides excellent abrasion resistance, insulation value, and UV resistance. In addition, the cap is clear to allow visual inspection of connector positioning during installation and connector performance during service life. Range taking connector: The special three wire connector is perfect for street light connections. There are two ports that accept wires from #14-2/0 AWG. Use these for the feeder cable. There is a single port that accepts #14-6 AWG. Use this port to power the light. Fast and easy installation: GelCap SL splice cover kits provide the fastest installation. Simply push the cover down over the connection and snap the clamp closed. No extra materials or greases are required. The PowerGel sealant is already in the cap. Easy to reenter: The GelCap SL splice cover kit s cover is easy to reenter because the PowerGel sealant pulls away leaving a clean connection. Reentry is also safer than other methods because no sharp objects or cutting tools are required for removal of the cap. Other common uses for GelCap splice cover kits: Irrigation systems HVAC Outdoor lighting Motor Connections Start saving money by using GelCap splice cover kits rather than the old, unreliable, and time consuming methods. Hole A Hole B Recommended Recommended Kit Wire Range Torque Values Wire Range Torque Values GelCap-SL #14-2/0 AWG 120-180 in-lbs #14-6 AWG 120-150 in-lbs 2/0-3 Hole (2-70 sq. mm) (13.6-20.3 N-m) (2-10 sq. mm) (13.6-17 N-M) Testing Chemical Resistance Ozone Resistance Accelerated Aging UV Resistance Abrasion Resistance Test Conditions ASTM D543, Sulfuric acid, Sodium Hydroxide, Transformer and motor oil ASTM D1149, 120 hours @40 C, 50pphm ASTM D2671 ASTM G53, UVB, 4000 hours, 4 hour on/off cycle 2040 gm wt., 4000 cycles, 5% max thickness loss Ordering Information 1. Selections are based on typical dimensions of low-voltage insulated cables. 2. Kits include UL Listed connectors for use with copper and/or aluminum conductors. 3. Each kit contains a gel filled cap, cap clamp, and connector. 4. Standard Package: 10 kits/box 600V/105 C Tyco Electronics Corporaton Issued 2004-2005 USA: 800-327-6996 Fax: 800.527.8350 Outside US: 919.557.8903 http://energy.tycoelectronics.com

Product Installation Instructions GelCap SL Insulating Splice Kit for 600V Cable LISTED 90UF Insulating Splice Cover 600V/105C Tyco Electronics Corporation Energy Division 8000 Purfoy Road Fuquay-Varina, NC 27526 PII-55194, Rev AA PCN C04258-000 Effective Date: March 15, 2002

The following items should be included in this kit: General Instructions Suggested installation equipment: 1 ea. Gel filled cap 3/8 Hex wrench 1 ea. Clamp 1/4 Hex wrench 1 ea. Connector Cable preparation tools Installation Instructions 1. Product selection Dimensions in inches (mm/metric) Kit Holes A Hole B Wire Range Recommended Wire Range Recommended Torque Values Torque Values GelCap-SL-2/0-3 Hole #14-2/0 AWG 120-180 in-lbs. #14-6 AWG 120-150 in-lbs. (2-70 sq. mm) (13.6-20.3 N-m) (2-10 sq. mm) (13.6-17 N-m) Connector Hole B Holes A 400 2. Remove insulation and clean cables Insulation removal length equals connector insertion depth (A). A 5/8" (16 mm) 1862 3. Make connection Insert conductors into connector and tighten screws according to the chart above. PII-55194, Rev AA 2 PCN C04258-000 Effective Date: March 15, 2002

4. Push sealing cap onto connection A. Install clamp on cap. Verify proper placement of clamp by ensuring the two pins on the bottom edge of the clamp are mated with the holes of the cap as shown in Figure 1a. B. Install cap by holding all wires and pushing the cap over the connection assembly until it goes no further. (Figure 1) Figure 1: Push cap onto Connection Clamp Installation Instructions Cap Figure 1a Pin C. Snap clamp closed. If necessary, use pliers to snap clamp closed. See figure 2. 404 Hole 201a Pressure Point Clamp Cap Apply pressure on closing tabs to close. Pressure Point Ensure the tap wire is not directly between the clamp pressure point Figure 2: Clamp pressure points should fit into opposing grooves of cap and apply pressure between cables. Snap clamp closed. 202 PII-55194, Rev AA 3 PCN C04258-000 Effective Date: March 15, 2002

Installation Instructions 5. Inspect installation Gently pull on cap to be sure it is locked in place. Ensure cap covers connector and bare conductor. There should be no exposed metal. Clamp should be below connector. Ensure tap cable is not caught between pressure points of clamp. Installation is complete. 405 6. Removal Insert screwdriver between closing tabs and twist to open the clamp. Remove cap slowly from connection allowing gel to stay in cap. 406 The Information contained in these installation instructions is for use only by installers trained to make electrical power installations and is intended to describe the correct method of installation for this product. However, Tyco Electronics has no control over the field conditions which influence product installation. It is the user's responsibility to determine the suitability of the installation method in the user's field conditions. Tyco Electronics' only obligations are those in Tyco Electronics' standard Conditions of Sale for this product and in no case will Tyco Electronics be liable for any other incidental, indirect or consequential damages arising from the use or misuse of the products. Raychem and GelCap are trade marks of Tyco Electronics Corporation. PII-55194, Rev AA PCN C04258-000 Effective Date: March 15, 2002 4 2002 Tyco Electronics Corporation Printed USA 3/15/02

1.0 10/ 01/ 03 REV PCR # DATE BY 8000 PURFOY RD. FUQUAY-VARINA, N.C. 27526 TITLE: FOR REFERENCE ONLY SCALE: 1/ 1 DWG. NO. ASSEMBLY REF DIMENSIONS REV. GC1 1.0

Cold-applied motor connection kits Motor Connections Index Main Index GelCap Motor connector kit (1000V) 120 GelCap motor connector kits quickly and conveniently insulates seal, and protect stub splice connections up to 1000 volts. The robust yet compact design was engineered to handle the harsh environment of motor connections. GelCap connector kits are equally well suited to many other connection applications including street light connections. The specially formulated material provides excellent abrasion resistance, insulation value, and UV resistance. In addition, the cap is clear to allow visual inspection of connector positioning during installation and connector performance during service life. Each cap size is designed to fit a wide range of cable sizes. The expandable design keeps the cap as small as possible and allows it to expand only as much as needed to fit on large cable. Gelcap connector kits provide the fastest installation. Simply push the cover down over the connection and snap the clamp closed. No extra materials or greases are required. The PowerGel sealing gel is already in the cap. Common uses for GelCap connector kits Street lights Over wire nuts for sealing Irrigation systems HVAC Outdoor lighting Selection information (dimensions in inches/millimeters) Max. Bolt Max. Lug Catalog Dimensions Dimensions Cap length number Feeder Conductor Size (mm 2 ) Width (A) Length (B) Total Length (C) Barrel Length (D) (nominal) GelCap 1* #16 #10 AWG (1.5 5).375 (10).500 (13) 1.00 (25) 0.5 (13) 2.8 (71) GelCap 2 #8 #2 AWG (8 35).625 (16) 1.00 (25) 2.00 (51) 1.0 (25) 3.5 (89) GelCap 3 #2 #4/0 AWG (35 105).850 (22) 1.30 (33) 3.00 (76) 1.5 (38) 6.0 (152) GelCap 4 250 500 kcmil (125 250) 1.100 (28) 1.85 (47) 5.00 (127) 2.0 (51) 8.0 (203 * For wire sizes #16 #10 the unique design of the GelCap motor connector1 kit saves space by allowing all three phase connections to be installed in one cover. For cold applied in-line splices see GelWrap splice closure, page 28 GILS, page29, or RVS, page30. Product Performance The Tyco Electronics GelCap connector kit meets the following requirements: Testing Chemical Resistance Ozone Resistance Accelerated Aging UV Resistance Abrasion Resistance Test Conditions ASTM D543, Sulfuric acid, Sodium hydroxide, Transformer and motor oil ASTM D1149, 120 hours @40 C, 50pphm ASTM D2671 ASTM G154, UVB, 4000 hours, 4 hour on/off cycle 2040 gm wt., 4000 cycles, 5% max thickness loss B Ordering information 1. Select appropriate catalog number based on the motor feeder cable, motor pigtail leads of the same size or smaller are suitable. GelCap connector kit selections are based on typical dimensions of low-voltage insulated cable. 2. Kits do not contain connectors. 3. Kit contents: GelCap - 1, One gel filled cap, one cap clamp, and one phase separator. Kit is designed for 3 phases in one cap. GelCap -2, 3, 4: three gel filled caps and three cap clamps. 4. Standard package: 5 kits/box 5. Related Product Information: EDR-5334 Test Report C D 1/4" max. 600 V/105 C

Product Installation Instructions GelCap Insulating Splice Cover for 600V Cable GelCap Splice Cover Size 1. LISTED 90UF Insulating Splice Cover 600V/105C Tyco Electronics Corporation Energy Division 8000 Purfoy Road Fuquay-Varina, NC 27526 PII-55152, Rev AC PCN 134042-000 Effective Date: August 28, 2002

Kit Contents General Instructions 1 ea. Gel filled cap 1 ea. Clamp 1 ea. Phase separator Installation Instructions This installation instruction applies only to GelCap 1 sealing caps. A different installation instruction is required for GelCap 2, 3, and 4 sealing caps. 1. Product selection Table 1 - UL Listed Connector / Cap Selection Guide Max. Bolt Dimensions Max. Lug Dimensions Kit Conductor Size Width (A) Length (B) Total Length (C) Barrel Length (D) GelCap-1 # 16 to # 10 AWG.375.500 1.00 0.5 GelCap-2 # 8 to # 2 AWG.625 1.00 2.00 1.0 GelCap-3 # 2 to # 4/0 AWG.850 1.30 3.00 1.5 GelCap-4 250 to 500 mcm 1.100 1.85 5.00 2.0 General Use Guide Check kit selection with cable dimensions in Table 1. If the conductors are not the same size, select kit based on largest conductor. For pin and socket connectors, dimensions must be within dimensional guidelines shown in Table 1. 2. Remove insulation See Table 1 above for maximum bolt (A,B) and lug (C,D) dimensions. Insulation removal length equals connector insertion depth/barrel length (D). B A C D 1/4" Max. 1862 3. Install lugs; make connection Install lugs on cables. Bolts should be inserted through the hole of the smallest lug first. Leads must be parallel for a minimum of 1-1/2" (40mm) beyond the end of the longest lug. 1-1/2" (40mm) Parallel Length 1863 PII-55152, Rev AC 2 PCN 134042-000 Effective Date: August 28, 2002

4. Place connections on phase separator Installation Instructions Phase separator Place each of the phase connections on the phase separator as follows: A. Insert connection in the connection area (Figure 1). B. Rotate cables so they are adjacent to the phase separation wall (Figure 2). C. Pull down so the crotch of each phase connection hangs on the phase separator (Figure 3). Figure 1 101 102 Figure 2 103 Figure 3 PII-55152, Rev AC 3 PCN 134042-000 Effective Date: August 28, 2002

5. Push sealing cap into connection A. Install cap by holding all wires and pushing the cap over the phase separator and connection assembly until it goes no further. Be sure the connections remain in place on the phase separator. Hold cap in place for 5 seconds. (Figure 4) B. Verify proper placement of clamp by ensuring the two pins on the bottom edge of the clamp are mated with the holes of the cap as shown in Figure 4a. C. Snap clamp closed. If necessary, use pliers to snap clamp closed. Figure 4: Push cap onto connection 201 Clamp Installation Instructions Cap Figure 4a Pin Hole 201a Pressure Point Clamp Cap Apply pressure on closing tabs to close. Pressure Point Figure 5: Clamp pressure points should fit into opposing grooves of cap and apply pressure below phase separator. Snap clamp closed. 202 PII-55152, Rev AC 4 PCN 134042-000 Effective Date: August 28, 2002

Installation Instructions 6. Inspect installation Gently pull on cap to be sure it is locked in place. Check to verify that each phase connection is in place on phase separator. Ensure cap covers lugs and bare conductor. There should be no exposed metal. Clamp should be below phase separator. Installation is complete. 301 7. Removal Insert screwdriver between closing tabs and twist to open the clamp. Remove cap slowly from connection allowing gel to stay in cap. 302 The Information contained in these installation instructions is for use only by installers trained to make electrical power installations and is intended to describe the correct method of installation for this product. However, Tyco Electronics has no control over the field conditions which influence product installation. It is the user's responsibility to determine the suitability of the installation method in the user's field conditions. Tyco Electronics' only obligations are those in Tyco Electronics' standard Conditions of Sale for this product and in no case will Tyco Electronics be liable for any other incidental, indirect or consequential damages arising from the use or misuse of the products. Raychem and GelCap are trademarks of Tyco Electronics Corporation. PII-55152, Rev AC PCN 134042-000 Effective Date: August 28, 2002 5 2002 Tyco Electronics Corporation Printed USA 8/28/02

Product Installation Instructions GelCap Insulating Splice Cover for 600V Cable This instruction provides procedure for installation of GelCap splice covers sizes 2, 3, and 4. LISTED 90UF Insulating Splice Cover 600V/105C Energy Division Raychem Tyco Electronics - Energy 8000 Purfoy Road Fuquay-Varina, NC 27526 PII-55148, Rev AD PCN 004180-000 Effective Date: Oct 5, 2006

The following items should be included in this kit: General Instructions 3 Gel filled caps 3 Clamps Installation Instructions 1. Product selection Table 1 - UL Listed Connector / Cap Selection Guide Max. Bolt Dimensions Max. Lug Dimensions Kit Conductor Size Width (A) Length (B) Total Length (C) Barrel Length (D) Tang Length (E) GelCap 1* # 16 to # 10 AWG.375.500 1.00 0.5 GelCap 2 # 8 to # 2 AWG.625 1.00 2.00 1.0 1.0 GelCap 3 # 2 to # 4/0 AWG.850 1.30 3.00 1.5 1.5 GelCap 4 250 to 500 mcm 1.100 1.85 5.00 2.0 3.0 *GelCap 1 insulating splice cover is designed for 3 phases in one cap and requires a different installation instruction. General Use Guide Check kit selection with cable dimensions in Table 1. If the conductors are not the same size, select kit based on larger conductor. For split bolt or pin and socket connectors, dimensions must be within dimensional guidelines shown above. 2. Remove insulation See Table 1 above for maximum bolt (A+B) and lug dimensions (C+D+E). Insulation removal length equals connector insertion depth/barrel length (D). B A E C D 1/4" Max. 1862 3. Install lugs Install lugs on cables. Bolts should be inserted through the tang of the smallest lug first. Leads must be parallel for a minimum of 1-1/2" (40mm) beyond the end of the longest lug. 1-1/2" (40mm) Parallel Length 1863 PII-55148, Rev AD 2 PCN 004180-000 Effective Date: Oct 5, 2006

4. Push cap onto connection A. Before installing cap, ensure the two pins on the bottom edge of the clamp are mated with the holes on the cap as shown in Figure 1a. B. Align cap so pressure points of clamp will align with crotch of cables as shown in Figure 2. C. Install cap by pushing onto connection until it goes no further. Hold cap in place 5 seconds. D. Snap clamp closed. If necessary, use pilers to snap clamp closed. Clamp Figure 1: Push cap onto connection. Pressure Point Installation Instructions Figure 1a Hole Pin Clamp Cap Crotch of Cables Pressure Point Apply pressure on closing tabs to close. Figure 2: Clamp pressure points should fit into opposing grooves of cap and apply pressure in crotch of cables. Snap clamp closed. 5. Inspect installation Gently pull on cap to be sure it is locked in place. Ensure cap covers lugs and bare conductor. There should be no exposed metal. Clamp should be below bolt and nut area. Installation is complete. 6. Removal Insert screwdriver between closing tabs and twist to open the clamp. Remove cap slowly from connection allowing gel to stay in cap. The Information contained in these installation instructions is for use only by installers trained to make electrical power installations and is intended to describe the correct method of installation for this product. However, Tyco Electronics has no control over the field conditions which influence product installation. It is the user's responsibility to determine the suitability of the installation method in the user's field conditions. Tyco Electronics' only obligations are those in Tyco Electronics' standard Conditions of Sale for this product and in no case will Tyco Electronics be liable for any other incidental, indirect or consequential damages arising from the use or misuse of the products. Raychem and GelCap are trade marks of Tyco Electronics Corporation. PII-55148, Rev AD PCN 004180-000 Effective Date: Oct 5, 2006 3 2006 Tyco Electronics Corporation Printed USA 8/5/06

4 3 2 1 1.78 D D 1.05 C C B.50 3.53 1.50 REV PCR # DATE BY CKD 8000 PURFOY RD. FUQUAY-VARINA, N.C. 27526 A REFERENCE ONLY SCALE: 1/1 DWG. NO. 4 3 2 1 TITLE: GEL CAP #2 ASSEMBLY REF DIMENSIONS REV. GC2 1.0 A