Central Station SIA Protocal

Similar documents
Type Report Report Date: 11/12/2015

What s New. Installation Manual. Please see page ii. Version 2.X

TS700. Intruder Alarm Control Panel ENT 0 ESC

RE6100 Series Helix Security and Automation Platform

Contact ID as of 2/2/2015

CONTACT ID REPORT CODES

CDMAEX. CDMA Primary Cellular Alarm Communicator INSTALLATION & USER S GUIDE

Contact ID as of 11/28/2018

4G PRIMARY ALARM COMMUNICATOR INSTALLATION & USER S GUIDE

ADEMCO CONTACT ID REPORTING (revised )

Technical Manuals Online! - Keypad Programming. Basic Programming

LTE30EX. LTE Primary Cellular Alarm Communicator INSTALLATION & USER S GUIDE

ITI Caretaker Basic Commands

4-PGM Expansion Module

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

CARETAKER PLUS: MOST FREQUESNTLY ASKED QUESTIONS. Which sensor programming group should I use for a wireless freeze sensor?

SENTROL ZX300/ZX310. Expandable Security System Control. Installation/ Programming 1

1.1 Features Accessory Devices About This Manual How to Use This Manual

8-zone Expansion Module

Installation Instructions

Property of Monitronics Inc

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Control/Communicator Installation Manual

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

Proudly Designed and Manufactured in New Zealand. By Arrowhead Alarm Products Ltd

Type Report Report Date: 1/21/2015

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

Scantronic Leading the way in security

Fire Command Center. XR2400F User s Guide

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Installation Manual Premier 412/816/832. Issue 10

XRSuper6. User s Guide. Technical Manuals Online! -

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

EMERgency 24 Internal Codes - Alphabetic

Safewatch Pro 3000 System Manual

HILLS Series LCD Code Pad User Manual

2000 Series. Program Entry Guide. Control Panels

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

First Alert 1200C Installer Notes M. Leuck

LYNX Touch Security System

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

System Introduction. 1.1 Specifications S E C T I O N 1

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

NX148-E LCD KEYPAD TABLE OF CONTENTS

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

Silencing an Alarm All/Perimeter and Home/Away Systems. Area Systems. What to do when a trouble tone is sounding

X64 Wireless Training

How to Use Your Sentrol Security System

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

Version 1.03 January-2002 USER S MANUAL

Property of Monitronics Inc

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Concord 4 User Manual

VISTA-100 Commercial Fire & Burglary Partitioned System

XRSuper6. User s Guide

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

First page of this international document resides under separate cover: 20SEaCOV.ps

GEM-P800 Programming Instructions

Series. NX-4-EUR Control Panel. Installation manual

SuperBus Hardwire Output Module (HOM) Document Number: Rev. D March 1999

User s Information Guide R2A

System Introduction. 1.1 Specifications

EVO192 v3.0 Fire and Burglary What s New

SENTROL ZX200/ZX210. Security System Control. Installation/ Programming

Training Manual with Bi-directional Wireless

Simon XT User Manual R-11 and R-11-CN P/N REV B ISS 13JAN11

SENTROL ZX400/ZX410. Security System Control. Programming

LYNX Touch L5210 Series Security System

Technical Manuals Online! - Enter Code Power NO DELAY. Stay. Away. Away A. Stay. Off. Off. Status. ALARM - Both Flashing

Wireless Security System

Easy Series Control Panel ICP-EZM2

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

D1265. User's Guide. Touchscreen Keypad

Digiplex LED Keypads. User s Manual

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

AdvisorOne Quick Operation Guide

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

ELECTRONICS LINE S TECHNICAL SUPPORT DEPARTMENT: (972)

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

Simon XTi Quick Operation Guide

Technical Manuals Online! - K4855V1 3/00 FA560 3 STAY B 1 OFF 2 AWAY 6 C D 5 TEST 9 CHIME # 8 CODE I I I I I I READY ARMED MAX

QUICK USER GUIDE. Alarm Control Panel

Security System. User Guide for the LED Command Center

ADEMCO VISTA-12A ADEMCO VISTA-12E

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

Procedure. for. Installation. of the P/N & P/N Voice Alert Systems. Procedure IP 1 Rev. 1. Date

Tomorrow s technology for today s security needs.

LYNX Touch Security System


Fire Command Keypad. XR5 User s Guide

Transcription:

Sensor name or Type AC Power Failure AT AT AT AT AT AT AT AC Power Restored AR AR AR AR AR AR AR Alarm Cancel OC OC OC Police Alarm Cancelled PH BH PH PH Auto Force Arm CF CF CF CF CF Automatic Phone Test RP RP RP RP RP RP RP Auxiliary Alarm Cancelled Touchpad MH PH MH MH Auxiliary Alarm Panic Touchpad MA PA MA MA PA PA MA Burglary Alarm BA BA BA BA BA BA BA Burglary Alarm Cancel BH BH BH BH Burglary Bypass BB BB BB BB BB BB Burglary Restoral BR BR BR BR BR BR Burglary Supervisory BS BS BS BS BS BS BS Burglary Trouble Restore BJ BJ BJ BJ BJ BJ Burglary Unbypass BU BU BU BU BU BU Burglary: Trouble BT BT BT BT BT BT Bus Module Tamper ET ET ET ET Callback * * Closing Report CL CL CL CL CL CL CL Duress Alarm HA HA HA HA HA HA HA Early to Close CK CK CK Early to Open OK OK OK Emergency Alarm QA QA QA QA QA QA QA Emergency Alarm Cancel QH QH QH QH Emergency Bypass QB QB QB QB QB QB Emergency Restoral QR QR QR QR QR QR Emergency Supervisory QS QS QS QS QS QS QS Emergency Trouble QT QT QT QT QT QT Emergency Trouble Restore QJ QJ QJ QJ QJ QJ Emergency Unbypass QU QU QU QU QU QU Energy Saver <Freeze Limit ZA ZA ZA Energy Saver Alarm is Cancelled ZH ZH ZH Energy Saver Enabled ZT Entering Installer Programming LB LB LB Entering Sensor Test TS TS TS TS Equipment Failure (TIM EEPROM) IA Events Report JL JL JL JL Exit Fault EE Exiting Installer Programming LX LX LX Exiting Sensor Test TE TE TE TE Fail to Close CI CI CI CI CI.5 LifeGard Page 1 of 6

Fail to Open OI OI OI OI OI Fire Alarm FA FA FA FA FA FA FA Fire Alarm Cancel FH FH FH FH FC FC FC Fire Bypass FB FB FB FB FB FB FB Fire Panic Touchpad FA FA FA FA FA FA FA Fire Restoral FR FR FR FR FR FR FR Fire Supervisory FS FS FS FS FS FS FS Fire Trouble FT FT FT FT FT FT FT Fire Trouble Restore FJ FJ FJ FJ Fire Unbypass FU FU FU FU FU FU Force Armed CW CW CW CW CW CW CW Freeze Alarm ZA ZA ZA ZA ZA ZA Freeze Alarm Cancel ZH ZH ZH ZH ZC ZC Freeze Bypass ZB ZB ZB ZB ZB ZB Freeze Restoral ZR ZR ZR ZR ZR ZR Freeze Supervisory ZS ZS ZS ZS ZS ZS Freeze Trouble ZT ZT ZT ZT ZT ZT Freeze Trouble Restore ZJ ZJ ZJ ZJ ZJ ZJ Freeze Unbypass ZU ZU ZU ZU ZU ZU Gas Alarm GA GA GA GA GA GA Gas Alarm Cancel GH GH GH Gas Bypass GB GB GB GB GB Gas Restoral GR GR GR GR GR Gas Supervisory GS GS GS GS GS GS Gas Trouble GT GT GT GT GT GT Gas Trouble Restore GJ GJ GJ Gas Unbypass GU GU GU GU GU GU Latchkey CT CT Late to Close CJ CJ CJ Late to Open OJ OJ OJ Listen In L90 L90 Low Panel Battery YT YT YT YT YT YT YT Low Panel Battery Restored YR YR YR YR YR YR YR Manual Phone Test RX RX RX RX RX RX RX Marginal Two Way Device Com. ET Medical Prescription Missed No Activity NA NA NA NA NA NA No Activity Alarm Cancelled NS NS NS NS NS NS Opening Report OP OP OP OP OP OP OP Panel Back in Service RR RR RR RR Panel Tamper TA TA TA Panel Tamper Restore TR TR Panic Alarm PA PA PA PA PA PA PA Panic Alarm Cancel PH PH PH PH PC PC PC Panic Bypass PB PB PB PB PB PB PB Panic Restoral PR PR PR PR Page 2 of 6

Panic Supervisory PS PS PS PS PS PS PS Panic Trouble PT PT PT PT PT PT PT Panic Trouble Restore PJ PJ PJ PJ PJ PJ PJ Panic Unbypass PU PU PU PU PU PU Phone Failure YC YC Phone Line Back Up [Not Sent] YK YK Phone Line Restore LR LR Phone Trouble LT LT Police Panic Touchpad PA BA PA PA BA BA PA Receiver Jammed XQ XQ XQ XQ XQ XQ XQ Receiver Supervisory XS XS XS Recent Closing CR CR CR CR Smoke Detector Reset FR Tamper Restore Touchpad JP JP JP JP Tamper Touchpad JA JA JA JA Temp. >Freeze Limit +5 ZR ZR ZR Temp. Data not received from ES ZT ZT ZT TIM Lost YC Transmitter Battery Resoral XR XR Transmitter Battery Trouble XT XT XT Two Trip Error XM XM XM Untyped Alarm UA UA UA UA UA UA Untyped Alarm Cancel UH UH UH Untyped Bypass UB UB UB UB UB UB Untyped Restoral UR UR UR UR UR Untyped Supervisory US US US US US Untyped Trouble UT UT UT UT UT Untyped Trouble Restore UJ UJ UJ UJ UJ Untyped Unbypass UU UU UU UU UU Untyped Zone Bypassed UB Untyped Zone Supervisory US Wireless Touchpad LB Restore XR XR Wireless Touchpad Low Battery XT XT XT Wireless Touchpad Supervisory US US US Page 3 of 6

Second Character First Character Sensor Groups 00-01 P P P P P P P 02-03 P P P P P P P 04-07 Q Q Q Q Q Q Q 08-09 B B B B B B B 10-12 B B B B B B B 13 B B B B B B B 14-20 B B B B B B B 21-25 26 F F F F F F F 27-28 29 Z Z Z Z Z Z 32 W W 33 U U U U U 34 G G G G G G 35 B B B 36 U Report Classification Alarm A A A A A A A Bypass B B B B B B B Alarm Cancel H H H H C Trouble Restore J J J J Restoral R R R R R R R Supervisory S S S S S S S Trouble T T T T T T T Unbypass U U U U U U.5.5 LifeGard LifeGard Page 4 of 6

Misc. Zone Classification System 00 00 00 00 00 00 00 Normal Sensors 01-99 01-99 01-99 01-99 01-24 01-24 01-20 User Code 600-699 100-199 600-699 600-699 31-35 31-35 31-36 Bus Device 500-595 200-299 500-595 500-595 -- -- -- TP Aux Panic 597 -- 597 597 25 25 97 TP Police Panic 598 -- 598 598 27 27 98 TP Fire Panic 599 -- 599 599 28 28 99 Premise Phone -- 900 900 900 -- -- -- Remote Access -- 902 902 902 -- -- -- Keyswitch Arming 908 908 908 908 -- -- -- Reboot or CPU Failure 909 909 909 909 -- -- -- Panel Tamper -- -- -- -- 26 26 -- During Phone Conversation -- 901 -- -- -- -- --.5 RF TP Zones -- 300-399 -- -- -- -- -- Misc. Zones 900-999 900-999 900-999 900-999 -- -- -- Duress Code 36 36 37 Master Code 30 30 30 *Audio Call Back Page 5 of 6

Page 6 of 6