Brownell Transformer Breathers

Similar documents
Transformer Breathers

Data Sheet. Humidity control products. Data Pack K Issued February

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

FWC153, FWC304, FWC604 & FWC624

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

Dual Column Dehydrating Breather Manual

fwc152 / fwc303 / fwc603 / fwc623 Wine Coolers Manual for Installation, Use and Maintenance

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

Grant Spira 6-26kW and 9-36kW Wood Pellet Boilers

FWC860 Wine Cooler Installation, Use and Maintenance

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER

5CONSIDERATIONS WHEN SELECTING A DESICCANT BREATHER FOR YOUR EQUIPMENT

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. A Issue F. ITC800 Inlet Chemical Trap. ITD20K Inlet Desiccant Trap

AIR SENTRY DESICCANT BREATHERS

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

MFC501 & MFC701. Manual for installation, use and maintenance. Integrated fridge-freezers. year.

Vacmobile 20/2. Instruction manual OPERATION & SERVICE

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

Assembly Instructions SMH 3 Stage MSA

The Impact of Cold Temperatures on Desiccant Breather Performance

Installation and maintenance instructions

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

Installation, Operating and Servicing Instructions

METRO BASIN MONO MIXER CHR

Traditional Rigid Riser With Eight Inch Rose

DRYAIRE DESICCANT SYSTEM MODEL 6760

Level Electrode NRG NRG Original Installation Instructions English

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Beautifully Traditional

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

FIRE EXTINGUISHER SERVICING & MAINTENANCE INSTRUCTIONS

Mira Reflex Thermostatic Bar Valve

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

SHOT BLAST CABINET USER INSTRUCTIONS. Model No: CSB20B. Part No: GC05/13

(Toll Free); 7am-7pm Pacific Time, Monday-Saturday. Assembly instructions for: DUSTIN S FACE TO FACE GLIDERS WITH XW ROOF

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

===================== LandyAir - Disco 3/4 &RR Sport

Beautifully Traditional

Distinction. D4000 & D4000/EURO Water Still. Assembly and Operating Instructions. 1 Issue 2

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

BUREAU OF METEOROLOGY

TECH REPORT 200: Use of Water Traps and Drying Filter with the FX-5000 Tension System. Document: Water Trap and Drying Filter Tech Report, Rev. 8.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Enzo Concealed Shower Mixing Valve

Technical Data Sheet No. JS-SM-38 DOCUMENT TITLE 3.5KG CARBON DIOXIDE FIRE EXTINGUISHERS

CalMag Heating Pack Installation Instructions

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Chapter 3 Cooling, heating and ventilation systems

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

Condair Esco. Steam humidification system INSTALLATION INSTRUCTIONS EN 1310

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

ASPECT VISION DELIVERED

WG701E. WG701E-M indd :19:20

Alpha CombiMax 350 and 600

Camera Housing Washer Units 5 and 25 Litre

Beautifully Traditional

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. idealvac.com (505) idealvac.com. ITC800 Inlet Chemical Trap

019 ASSEMBLING THE HOTEND

Adjustable Electric Heater

OP44-1 REV 2: Removed depiction of air intake hole in the CB-907A Right Aft Case Baffle.

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

THERMOSTATIC SHOWER CONCEALED VALVE - TWIN WITH DIVERTER & TRIPLE WITH DIVERTER

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Desiccant Breathers: A Front Line Defense in the War on Contamination

ASSEMBLY & OPERATING INSTRUCTIONS

NRG NRG NRG NRG

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Protected with TechCoat finish. For Ceramic Tile Showers Cast iron Threaded for test nipple Extra heavy (.050) strainer DRAIN CONNECTION

Engine Block Heater Service Kits (Tank Type) 30RZ/33RZ/45RZ (CSG 649 Ford Powered) Standby Generator Sets

OES MEDICAL. Draw over Anaesthetic vaporizer User Manual. Copyright OES Medical Ltd

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

JMP Series Plate Mounted Axial Flow Fans

AMBIRAD QUARTZ GLOW INSTANT INFRA-RED HEATERS INSTALLATION AND OPERATING MANUAL

Inta City Shower Mixing Valve CT20010CP

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Installation and maintenance instructions

A-DRY Heatless adsorption compressed air dryers

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

LINEAR HEAT DETECTION SENSOR CABLE ACCESSORIES

Plus Bath Shower Mixing Valve CP and PL30020CP

Humidity Indicators CATALOG 95H. Sustaining Member

General System Layout Sketch

Mounting Instructions Adapter for ventilation duct BWP-143A-SS, Stainless Steel version

Wave. BATH SHOWER MIXER MONOBLOC With Kit Deck Mounted

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Owner s manual for. Venco 87mm & 100mm. (3 1/ 2 & 4 ) De-airing Pugmill

MOUNTING INSTRUCTIONS

Level Electrode NRG Original Installation Instructions English

MBSY110P+ BASIN MONOBLOC WITH CLICK CLACK WASTE

Beautifully Traditional

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

METRO BATH FILLER MOUNTED CHR

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Transcription:

Transformer Moisture Control and Prevention Brownell Transformer Breathers

2 Transformer Breathers The failure or malfunction of many transformers or similar equipments can be directly attributed to the lack of proper control of the level of water vapour entering the equipment. It is essential, therefore, that a very low level of humidity is maintained in the air space in the top of the conservator tank to avoid deterioration of the insulating properties of the cooling medium. Transformer Breathers provide an economic and efficient means of controlling the level of moisture entering the conservator tank during the change in volume of the cooling medium and/or airspace caused by temperature gradients. All our Transformer Breathers are filled with Envirogel, which is a self-indicating silica gel desiccant. This desiccant is orange/yellow in colour when active, but turns green when saturated. Choose a sub-category of products from the Transformer Breathers category: R Series Breathers V,W,X,Y&Z Series Breathers S,T&U Series Breathers Envirogel (Indicating Silica gel) Dark Green = 80% saturation Colour Change Orange to green W W W. A R M S T R O N G E N E R G Y. C O M. A U

Products in R' Series Transformer Breathers. 3 The R Series Transformer Breathers from Brownell Ltd UK. are manufactured from UV stabilised polycarbonate and are available in three different sizes. The clear polycarbonate body allows for clear visibility of the desiccant charge and enables users to check desiccant condition with ease. The unit is mounted from a ¾ female pipe thread connection at the top of the breather. This connection point is also used for filling and emptying the desiccant within the breather. Two-way, low pressure valves are fitted in the base of the breather to ensure that the atmospheric air enters the desiccant when a negative pressure differential occurs within the equipment being protected. R Series Breathers Connection: 3/4" Female Pipe Thread conforming to BS21 and ISO7-1. Desiccant type: Envirogel self indicating beaded silica gel. Part No Size Weight of Overall Length Overall Diameter Desiccant BL/D6586 R 158mm 108mm 0.60 kg BL/D6942/01 R1 260mm 108mm 1.20 kg BL/D6942/02 R2 362mm 108mm 1.90 kg Selection Guide The following data should be used for the basic selection of a transformer breather. In order to assess the size of the breather the air volume above the oil in the conservator tank is the most important factor. The quantity of oil and the transformer rating is of secondary importance. The daily breathing rate is based on the assumption that there are two temperature drops of 8 C per 24 hours. The breathing volume change which occurs during the pump start-up is not taken into consideration.

4 Selection Table Max. Oil Contents Approx.Transformer Rating (MVA) Max. Air Approx. Daily Space Volume Rate Breathing Max. Air Volume Approx. before Recharge Charge Life (Days) Size R 1500 <1.25 230 15 6000 400 R1 3000 3 500 30 12000 400 R2 4750 6 1100 55 20000 400 Installation The breather is supplied with a threaded sealing plug screwed into the top moulding to prevent any water vapour ingress whilst in store. This plug should be removed immediately prior to the unit being fitted to the air vent pipe of the transformer reservoir tank. Fit the breather and tighten using the spanner flats provided at the top of the unit. Maximum torque on threads is 9Nm/80lbfin. NOTE: DO NOT ATTEMPT TO SCREW OR UNSCREW THE BREATHER BY HOLDING THE BODY WITH YOUR HANDS, USE A SPANNER ON THE FLATS PROVIDED. Operation Periodic inspection should be carried out to monitor the condition of the desiccant charge. The breathers are filled with beaded Envirogel desiccant. This material changes colour from orange to green as it becomes saturated with water vapour. When the colour change reaches the indicator line on the desiccant container it should be recharged with fresh desiccant or the complete assembly should be replaced. Maintenance If the breather is not routinely replaced when the desiccant becomes saturated, the only maintenance necessary is to replace the spent desiccant as detailed below. 1. Unscrew the breather from the vent pipe. 2. Remove the perforated cover in the top moulding and empty the spent desiccant from the container. This material may be disposed of in a normal landfill site. 3. Fill the container with active orange desiccant, lightly tap the container to settle the desiccant and top up if necessary. Desiccant refills are available from Brownell. 4. Replace the perforated cover and screw the recharged breather back onto the vent pipe. Desiccant Refills Envirogel refills - Part No. BL/D6331 offers capacities ranging from 0.5 to 50Kg.

5 Products in S,T & U' Transformer Breathers These Transformer Breathers have a removable desiccant container which allows the desiccant to be changed without breaking the breather pipe connection. The desiccant container is clamped between the top and bottom end mouldings by two metal tie rods with threaded wing nuts. By releasing the wing nuts, the desiccant container can be easily removed and refilled as required. The Transformer Breathers are manufactured from UV stabilised polycarbonate. The clear polycarbonate body of the desiccant container allows for clear visibility of the desiccant charge. The unit is mounted from a ¾ female pipe thread connection at the top of the breather. Two-way, low pressure valves are fitted in the base of the breather to ensure that the atmospheric air enters the desiccant when a negative pressure differential occurs within the equipment being protected. S,T&U Series Breathers Connection: 3/4" Female Pipe Thread conforming to BS21 and ISO7-1. Desiccant type: Envirogel self indicating beaded silica gel. Part No Size Dim A Dimn B Weight of Desiccant BL/D1140/01 S 174mm 127mm 0.45 kg BL/D1140/02 T 274mm 127mm 1.20 kg BL/D1140/03 U 474mm 127mm 1.80 kg

Selection Guide The following data should be used for the basic selection of a transformer breather. In order to assess the size of the breather the air volume above the oil in the conservator tank is the most important factor. The quantity of oil and the transformer rating is of secondary importance. The daily breathing rate is based on the assumption that there are two temperature drops of 8 C per 24 hours. The breathing volume change which occurs during the pump start-up is not taken into consideration. 6 Size Max. Oil Contents Approx. Transformer Rating (MVA) Max. Air Space Volume Approx. Daily Breathing Rate Max. Air Volume before Recharge Approx. Charge Life (Days) S 1130 1.5 285 17.5 7100 400 T 2250 3 570 35 14200 400 U 4500 6 1220 70 28400 400 Installation The breather is supplied with a threaded sealing plug screwed into the top moulding to prevent any water vapour ingress whilst in store. This plug should be removed immediately prior to the unit being fitted to the air vent pipe of the transformer reservoir tank. Full installation and maintenance instructions are supplied with each Transformer Breather. Operation Periodic inspection should be carried out to monitor the condition of the desiccant charge. The breathers are filled with beaded Envirogel desiccant. This material changes colour from orange to green as it becomes saturated with water vapour. When the colour change reaches the indicator line on the desiccant container it should be recharged with fresh desiccant. Maintenance The only maintenance necessary to keep the breather in a fully active condition is the replacement of the spent desiccant as detailed below. 1. Loosen the wing nuts on the tie rods until the desiccant container can be removed from between the top and bottom mouldings. 2. Remove the top perforated cover and empty the spent desiccant from the container. This material may be disposed of in a normal landfill site. 3. Fill the container with active orange desiccant, lightly tap the container to settle the desiccant and top up if necessary. Desiccant refills are available from Brownell. 4. Replace the perforated cover and refit the desiccant container between the top and bottom mouldings ensuring that it is fitted between the sealing gaskets. 5. Tighten the wing nuts but be careful not to over tighten as this can distort the mouldings. NOTE: If it is necessary to replace the complete desiccant container instead of recharging the existing unit, ensure that the self-adhesive aluminium foil vapour barriers are removed from the top and bottom of the container before installation. Desiccant Refills

Products in V,W,X,Y & Z' Transformer Breathers 7 This range of Transformer Breathers provides protection against moisture for large capacity tanks. With the larger amounts of desiccant required to maintain protection, the breathers are more robustly constructed. The Transformer Breathers have a removable desiccant container which allows the desiccant to be changed without breaking the breather pipe connection. The desiccant container is clamped between the top and bottom end plates by four metal tie rods with threaded nuts. By releasing the nuts, the desiccant container can be easily removed and refilled as required. The removable desiccant container is fabricated from mild steel which is protected with a phosphate and powder coat finish. The container has a UV stabilised polycarbonate clear window which allows for clear visibility of the desiccant charge. Top and bottom end plates are painted aluminium castings. The unit is connected either by a flange or pipe thread connection. Mounting brackets on the top plate provides additional support for the breather. Two-way, low pressure valves are fitted in the base plate of the breather to ensure that the atmospheric air enters the desiccant when a negative pressure differential occurs within the equipment being protected. V,W,X,Y&Z Series Breathers Mounting flange conforms to BS10 Table D. Alternative pipe connections: Size V, W & X : 3/4" Female Pipe Thread. Size Y & Z : 1 Female Pipe Thread. All threads conform to BS21 and ISO7-1 Desiccant type: Envirogel self indicating beaded silica gel. Part No Size Dia 'A' Dimn 'B' Dimn 'C' Weight of Desiccant BL/D6290/01 V 255mm 375mm 1"B.S.T.D. 5.0 Kg BL/D6290/02 W 255mm 555mm 1"B.S.T.D. 10 Kg BL/D6290/03 X 255mm 735mm 1"B.S.T.D. 14.5 Kg BL/D6290/04 Y 355mm 485mm 1"B.S.T.D. 17.5 Kg BL/D6290/05 Z 355mm 645mm 1"B.S.T.D. 27.3 Kg

8 Selection Guide The following data should be used for the basic selection of a transformer breather. In order to assess the size of the breather the air volume above the oil in the conservator tank is the most important factor. The quantity of oil and the transformer rating is of secondary importance. The daily breathing rate is based on the assumption that there are two temperature drops of 8 C per 24 hours. The breathing volume change which occurs during the pump start-up is not taken into consideration. Double & triple units are available upon request. Size Max. Oil Contents Approx. Transformer Rating (MVA) Max. Air Space Volume Approx. Daily Breathing Rate Max. Air Volume before Recharge Approx. Charge Life (Days) V 11350 9 2400 140 45450 320 W 22700 30 4800 280 90900 320 X 34050 60 7250 420 136500 320 Y 45450 100 9685 570 181800 320 Z 68150 180 14500 840 272700 320 XX 68100 180 14500 840 272700 320 YY 90900 240 19300 1140 363500 320 ZZ 136300 500 29000 1680 545400 320 ZZZ 204450 750 38750 2280 818100 320 Installation The breather is supplied with a sealing plug in the top casting. This plug is either screwed or pressed into position to prevent any water vapour ingress whilst in store. This plug should be removed immediately prior to the unit being fitted to the air vent pipe of the transformer reservoir tank. The units can be connected to the vent pipe either by flange or pipe thread connection. Mounting brackets on top casting provide additional support for the breather. Full installation and maintenance instructions are supplied with each Transformer Breather. Operation Periodic inspection should be carried out to monitor the condition of the desiccant charge. The breathers are filled with beaded Envirogel desiccant. This material changes colour from orange to green as it becomes saturated with water vapour. When the colour change reaches the indicator line on the desiccant container it should be recharged with fresh desiccant. Maintenance The only maintenance necessary to keep the breather in a fully active condition is the replacement of the spent desiccant as detailed below. 1. Loosen the nuts and remove the two tie rods, which are fitted in the slots in the top and bottom castings. Loosen the nuts on the fixed tie rods until the desiccant container can be removed from between the top and bottom castings. 2. Remove the top perforated cover and empty the spent desiccant from the container. This material may be disposed of in a normal landfill site. 3. Fill the container with active orange desiccant, lightly tap the container to settle the desiccant and top up if necessary. Desiccant refills are available from Brownell. 4. Replace the perforated cover and refit the desiccant container between the top and bottom casting ensuring that it is correctly fitted between the sealing gaskets. 5. Refit the two tie rods and tighten all the nuts, being careful not to over tighten.