SuperCDMS SNOLAB: Road to 100 mm Germanium Detectors

Similar documents
EDELWEISS-III dark matter search: first results and future

Detector Configurations for the MAJORANA Demonstrator

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR

The Majorana Demonstrator Update and Detector Technologies

North American Technical Services

GERDA Phase II Detectors and Acceptance Tests

Experimental Particle Physics PHYS6011 Joel Goldstein, RAL

Aging measurements on triple-gem detectors operated with CF 4 based gas mixtures

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current

Modifications and Improvements to the NPDGamma Liquid Hydrogen Target System and Safety

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

MAJORANA An Ultra-Low Background Enriched- Germanium Detector Array for Fundamental Physics Measurements

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

The new generation Teledyne NIR detectors for the SNAP/JDEM mission spectrograph.

Title: Semiconductor detectors with proximity signal

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

Commissioning of the Silicon Drift Detector of the ALICE experiment at the LHC

arxiv: v1 [physics.ins-det] 10 May 2017

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

On-chip optical detectors in Standard CMOS SOI

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Tracking Detectors 2 silicon for HEP

Freiburger Materialforschungszentrum SG Material Characterization & Detector Technology. Albert-Ludwigs-Universität Freiburg

arxiv: v1 [physics.ins-det] 1 Sep 2014

Status of the ENSAR2 JRA PSeGe

Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment

Competency: Critically evaluate the function of the ionisation chamber in the Linear Accelerator and its importance for correct treatment delivery

Highlights of Germanium Detector technology

Pyroelectric crystal based neutron source and neutron detector

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg.

Customized MCPs for Analytical Instruments. An MCP for every application

arxiv:astro-ph/ v1 17 Aug 2000

R&D Fast and lightweight EIC integrated tracking system Barrel MicroMegas & Forward Triple-GEM

Recent Advances in Large Area Micro-channel Plates and LAPPD TM

Diamond Detectors Ltd. Fabrication and Packaging Capabilities. Kevin Oliver

UV - flame detector dual fuel burners for intermittent burner operations

The FEL Facility Optical Diagnostics and FEL Characterization

Remote Helium Cooling Loops for Laboratory Applications

IFIN-HH, Hadron Physics Department infrastructure for ALICE TPC upgrade

Gaseous detectors. 1

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

SYNCHROTRON RADIATION ABSORPTION AND VACUUM ISSUES IN THE IR*

The LHCb Outer Tracker: Production & Ageing studies

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

2008 JINST 3 S The CMS experiment at the CERN LHC THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS.

ESTB Proposal from the Stony Brook University: Test of a RICH-Prototype Based on CsI-GEMs

ENHANCED VISION - INFRARED 1

New Generation of UV, IR and γ - ray sensors with Carbon Nano-Tubes (CNT)

Mechanical Concept of the TESLA Detector

T2SL technology for Mid-IR detectors

IAEA-SM-367/14/01 UTILIZATION OF FLUORESCENT URANIUM X-RAYS AS VERIFICATION TOOL FOR IRRADIATED CANDU FUEL BUNDLES

Measurement system for detection of Radon in building

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Passive Standoff FTIR Detectors as Transducers. Background From radiation to information

3B Heat, Light and Sound

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

arxiv: v2 [physics.ins-det] 9 Feb 2015

Instrumental technique (MCP detectors) - Kamalesh ( )

Germanium Detector Research at MPP

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

Can one cool the MICE magnets and the Hydrogen Absorbers with Small Coolers? Michael A Green Oxford University Physics Oxford OX1 3RH, UK

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: G08B 17/06 ( ) G08B 17/103 (2006.

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

Technical Specification PILATUS 100K Detector System

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

A GEM-based detector for detection and imaging sparks and flames G. Volpe 1 and V. Peskov 2. Abstract

Heat Management Methodology

Single-sided CZT strip detectors

A CONCEPT FOR CANCELLING THE LEAKAGE FIELD INSIDE THE STORED BEAM CHAMBER OF A SEPTUM MAGNET*

ORTEC. Detective-Remote. Multiple Instrument Remote Monitoring and Control Software. The right software, the right solution, the right answer!

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. Status of CMS Commissioning

PoS(ICHEP2012)516. The status of the CMS pixel upgrade detector

Properties of a two stage adiabatic demagnetization refrigerator

Portable Instruments For First Response & In-Situ Analysis of Radiation

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

W.E.T. (Water Extraction Techniques) Lab

Performance of a New Type of Electrical Cooler for HPGe Detector Systems

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Compact Raman spectrometer system for low frequency spectroscopy

GLAST Large Area Telescope: Collaboration Meeting. AntiCoincidence Detector: From Rome 2003 to SLAC September 28-30, 2004

TRULY HAND-HELD gamma-ray detectors with excellent

Texas active target (TexAT) detector part 1: Design and construction progress

Maintenance and Operation for ECAL Monitoring (WBS4.3)

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Substation Monitoring System

Status of the Advanced Virgo detector

Pool boiling heat transfer enhancement on porous surface tube

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Micromegas in a Bulk

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Transcription:

SuperCDMS SNOLAB: Road to 100 mm Germanium Detectors H. Chagani University of Minnesota for the SuperCDMS Collaboration 23 July 2012

The SuperCDMS Soudan Detector: izip interleaved Z-sensitive Ionisation & Phonon detector (izip) 3 φ 1 thick, 600 g Ge crystals Simultaneous measurement of phonon & charge signals Interleaved electrodes so surface events show up on one detector side only 2 Z [mm] 1 0!2!1 0 1 2 X [mm]

The SuperCDMS SNOLAB Experiment izip technology appears to meet requirements for larger target masses Scaling difficult: 340 3 φ 1 crystals for 200 kg mass A number of factors make this expensive: Increased manpower: fabrication and testing are labour intensive Increased heat load: additional wiring to room temperature Increased cold hardware and warm electronics Increasing the size of individual detectors can help alleviate these issues

The Road to 100 mm Germanium Detectors Up to 100 mm diameter detector-grade Ge crystals can be grown Three crystals of thickness 33.3 mm and mass 1.37 kg have been/are being tested: 1 Ionisation test device 2 Spiral electrode device 3 First 100 mm izip design Tests performed with existing CDMS-II 3 cold hardware with minor modifications: CDMS-II tower, side coaxes, cold electronics cards and striplines New extender plug to bridge gap between tower and side coax New detector housing to encase larger diameter crystal Tests utilise new warm electronics designed for SuperCDMS SNOLAB

The 100 mm Ionisation Test Device Ionisation electrodes patterned as 4 concentric rings Crystal volume of 64.3 cm 3 lies under each electrode for comparable responses Electrodes separated by 400 µm wide trenches Each electrode consists of a grid of 2 µm thick wires at pitch of 40 µm Sections of two inner electrodes extend through gaps to bring them closer to the detector edge for readout Uniform grid at ground present on opposite face

Ionisation Measurements Electrodes labelled Q1 from centre to Q4 at edge 60 kev γ-rays from four 241 Am sources used for ionisation measurements Each source collimated (activity 20 Bq) Each source placed above centre of electrode as shown by red dots

Charge Collection Efficiency Mean free path of 60 kev γ-rays in Ge is 1 mm Vary bias and determine change in position of 60 kev peaks Outer channel Q4 used as veto Uncalibrated charge spectra -4.0 V bias 100 mm φ 33.3 mm thick crystal from H. Chagani et al., J. Low Temp. Phys. 167 (2012) 1125 60keV peak in Qsum normalized to unity at 6 V 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 G102 Charge Collection Efficiency 0.4 Q1 0.3 Q2 Q3 0.2 10 5 0 Bias (V) 5 10

Charge Collection Efficiency Mean free path of 60 kev γ-rays in Ge is 1 mm Vary bias and determine change in position of 60 kev peaks Outer channel Q4 used as veto 30 mm φ 10 mm thick crystal from T. A. Shutt Ph.D. thesis, Berkeley (1993) 100 mm φ 33.3 mm thick crystal from H. Chagani et al., J. Low Temp. Phys. 167 (2012) 1125 60keV peak in Qsum normalized to unity at 6 V 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 G102 Charge Collection Efficiency 0.4 Q1 0.3 Q2 Q3 0.2 10 5 0 Bias (V) 5 10 Results consistent with scaling past measurements on 1 cm thick crystals: Bias voltage of 1.7 V required for complete charge collection These crystals have necessary charge collection efficiency to be operated as dark matter detectors

Charge Collection Efficiency Use 356 kev line from external 133 Ba source to measure charge collection efficiency in bulk Three inner electrodes exhibit similar response Charge collection efficiencies measured with 241 Am & 133 Ba sources are consistent

Ionisation Signal Stability Ionisation signal stability increases with bias Similar behaviour seen collecting electrons as that when collecting holes -4.0 V bias -6.0 V bias Short bursts of LED flashes over a period of < 6 s successfully remove charge traps and reset detector to its original state

The Spiral Electrode Device Two electrodes on each crystal face: inner disk and outer ring Grounded ribbon of width 250 µm interleaved with charge ribbons of width 40 µm Inner disk covers 66% of surface area Centres of grounded and charge ribbons lie 1.5 mm apart Top side is mirror of bottom face

Identification of Surface Events One 241 Am source installed facing inner charge channel on Side 2 Mean free path of 60 kev γ-rays in Ge is 1 mm Grounded and charge ribbon centres lie 1.5 mm apart Electrons/holes from 60 kev events mostly show up on Side 2 Charge Spectrum : Side 2 bias = -4.0 V 400 Number of Events 350 300 250 200 150 100 50 0 0 50 100 150 200 250 300 350 400 450 Energy [kev] Figure on right: z-partitioning = (Side1 Side2), radial partioning = 0 is central cylinder axis, (Side1+Side2) timing cut defined as (Time of event) < 150 s from start of data acquisition

Charge Collection Efficiency Sum of Inner & Outer Charge Channels 1.1 Inner Charge Channel Only 1.1 Charge Collection Efficiency 1.05 1 0.95 0.9 0.85 Side 1 Side 2 Charge Collection Efficiency 1.05 1 0.95 0.9 0.85 Side 1 Side 2 0.8-10 -5 0 5 10 Bias [V] 0.8-10 -5 0 5 10 Bias [V] 356 kev line from external 133 Ba source used to measure charge collection efficiency in bulk Curves normalised to unity at 12 V bias Charge collection efficiencies for both sides are reasonably uniform

The First 100 mm izip Two electrodes on each crystal face: inner disk and outer ring 12 phonon channels, six on each side Phonon ribbons of width 260 µm interleaves with charge ribbons of width 50 µm Centres of phonon and charge ribbons lie 1.5 mm apart Phonon channels rotated by 45 degrees about central axis on bottom face H. Chagani SuperCDMS SNOLAB: Road to 100 mm Germanium Detectors

First Phonon Pulses Readout through 3 Device Interface Boards (DIBs), to which CDMS-II side coaxes are attached Transition Edge Sensors (TES) critical temperatures lie between 76 mk & 86 mk No significant difference between critical temperatures on both sides Phonon pulse decay time 0.8 ms, in line with what we expect Side 1 Channel C

First Ionisation Signals Number of Events Charge Spectrum : Side 1 bias = -4.0 V 90 80 70 60 50 40 30 20 10 0 0 50 100 150 200 250 300 350 400 450 Energy [kev] Energy [kev] Charge as a function of Time : Side 1 bias = +4.0 V 450 400 350 300 250 200 150 100 50 0 0 200 400 600 800 1000 1200 1400 1600 1800 Time [s] Cryostat surrounded by new lead-polyethylene shield which should reduce background flux by a factor of 5 at surface testing facility Detector exposed to 133 Ba source for half-an-hour Peaks at 302 kev & 356 kev very clear Peak at 384 kev visible Ionisation signal stable for at least 30 minutes at -4.0 V bias

Conclusions 100 mm diameter Ge crystals have necessary charge collection efficiency to be operated as dark matter detectors izip principles, such as surface event rejection, can be applied to 100 mm diameter crystals The first 100 mm izip looks like a good detector and is currently undergoing detector characterisation tests Several 100 mm izip detectors in the pipeline