Unlocking the Potential of Blood TSCD II. Next-Generation Terumo Sterile Tubing Welder

Similar documents
BLOOD BANK REFRIGERATOR - BR Series

Dräger Bodyguard 1000 Warning Device

Thermo Scientific 1300 Series A2

Tropic 2.0 ultrasonic nebuliser

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

D Moving beyond telemetry INFINITY M300

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

Experience In Motion. DEF Product Support Catalog

Dräger OR Lights Simply good light

Dräger Pac 5500 Single-Gas Detection Device

T1/B1 OPTIONAL ASEPSIS HYGIENIC AIR HANDLING UNITS. Fully washable & free cold bridge design for food and low temperature applications

meets medilab Oil-free compressed air for the medical and laboratory market

Modular Sensing Cable Installation Instructions

This is azbil. A Company Shaping the Future with Automation

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

Figure 1 TWM1000 Electromagnetic Flow Converter. 1. Large, illuminated graphic display with intuitive operation 2. For AC and DC operation

Integrated Process Solutions. Series 49. Thermal Management System

Thermo Scientific MSC-Advantage Class II Biological Safety Cabinets. Good for you, good for the environment

From the World Leader in VRLA Battery Technology

Harrier + Smart Controller & Chemical Management System

WH EN IGH T T C LO SED

CO 2 Incubators: 7401, 7402 & 7403 Series

TT3000 and TT5000 Series

meets medilab Oil-free compressed air for the medical and laboratory market

edwardsvacuum.com VACUUM PUMPS EOSi ROTARY SCREW PUMP

Company Presentation

ReadyKart mobile processing station

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Oxylog VE300 Emergency & Transport Ventilation

Oxylog VE300 Emergency & Transport Ventilation

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

MDS-15. High-throughput Microwave Sample Preparation Workstation. The Transformer of Microwave Digestion

safe and your operations compliant

JCM Products Quick Reference Guide

G3 Electric Lubrication Pump For Series Progressive and Injector-based Systems

Integrated & Profitable Packaging Solutions FILLING CLOSING IN-CONTAINER STERILIZING. jbtc.com/foodtech

Training Gas Detection Level 3 Maintenance and Repair

Dräger Bump Test Station Calibration and Bump Testing

CUTMASTER. Superior Quality Economical Flexibility Increased Productivity Easy To Use. Automated Plasma Cutting Systems

Training Gas Detection Level 2 User and Calibration. Basic Information

Thermo Scientific Revco Value Freezers and Refrigerators. General Purpose Explosion Proof Flammable Material Chromatography

Simple and Versatile

HydroSpeed plate washer for 96- and 384-well formats

Dräger PointGard 2100 Detection of toxic gases and vapours

Intelligent Paint Kitchen

910 Series Single-point heat-tracing control system

G3 Electric Lubrication Pump

Duraplus ABS for Secondary Loop Refrigeration Control Systems

Lab-Quality Results for Point-of-Care Testing

Vernay-QM Series Disposable Pumps

Universal Connectivity Platform

We are needing a global trademark protecting system.

Hemovac Wound Drainage Family. The Time-Tested System for Reliable Wound Drainage and Auto-Transfusion

HYGIENE & SANITATION MOBILE LIVING MADE EASY.

VersaFlow Mag 2000 FL Electromagnetic Flow Sensor Technical Datasheet. Specification. Solution with high-tech ceramics. Highlights.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

HydroSpeed plate washer for 96- and 384-well formats

Connections. Application Note Jeronimo Rd. Irvine, CA February 20, 2008 Document Number AN0108, Rev A.1

BRANSONIC Bransonic Baths

PREFERENCE ICC. A Complete System For Efficient Sterilization

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

Vacuum Interrupters. Outstanding vacuum-related manufacturing techniques of MEIDEN has

Dräger Configuration and Evaluation Software

Automatic Condensate Drains ECO DRAIN Series

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

GETINGE WD15 CLARO 1 GETINGE WD15 CLARO THE CLEAR CHOICE IN WASHER-DISINFECTORS. Always with you

Introducing The Reliance 200 and 250 Glassware Washing Systems.

CO₂ incubators. C CB series

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

Heto PowerDry LL1500 Freeze Dryer

Dräger VVP 1000 System Components

CPS V Cabinet Power System

HYDRIM. Powerful cleaning the first step to effective sterilization. Instrument Washers A HIGHER STANDARD

Tomato Processing: Fruit Processing: Tomato & Fruit Processing System. Paste & Concentrate, Peeled Products

Trellex Dust Control. Screening Media

Henkel Automotive Display Solutions

NaturaLINE The world s first natural refrigerant unit for container refrigeration.

WELD STRONG BREATHE FREE

Quick start guide. BiPAP AVAPS

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

EcoMet 30. Grinder-Polisher Systems. EcoMet 30 Semi-Automatic Single and Twin

CO₂ incubators. C CB series

The future is bright. And clean. And fully automated.

Dräger Polytron 5720 IR Toxic Gas Detection

Pulp & Paper Solution. Pulp & Paper Solution. Instruments and Solution for Pulp & Paper Industry LF3BUSS03-00EN.

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

MicroRAE. Wireless, Portable Four-Gas Detector. Gas Detection

Frigoscandia Equipment GYRoCOMPACT

TT3000 and TT5000 Series

Rotary Screw Vacuum Systems

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

Safety Protection System 4 Security Levels 5. Deskside Shredders 6 Centralized Office Shredders 12 High Capacity Shredders 18

TraceTek TT1000 Modular Sensing Cable

Dry Block Heaters. Dry Block Heaters 2 Block Dry Block Heaters with Lid.

ChargeTime Plus USER GUIDE MODEL: TA-7850

WARM LINE. IV Fluid Warmer. Product Code: J1448. JORGENSEN LABORATORIES PHONE FAX

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

VWR symphony CO 2 INCUBATORS

Transcription:

Unlocking the Potential of Blood TSCD II Next-Generation Terumo Sterile Tubing Welder

1

About Terumo BCT POTENTIAL As a global leader in blood component, therapeutic apheresis and cellular technologies, we believe in the potential of blood to do even more for the world than it does today. This belief inspires our innovation and strengthens our collaboration with customers. By helping you enhance patient care, we unlock the potential of blood to: Make even safer, higher-quality transfusions available to more people Advance blood therapies to help customers bring more treatment options to patients Develop cellular therapies that may fundamentally improve health care Terumo BCT Unlocking the Potential of Blood 2

Consistent, fast and efficient networked sterile docking TSCD II sterile tubing welder helps you improve operational efficiency and bring more value to the hospitals you serve 3

Helping you take command of demand From donor management to collections and processing, the goal of blood centers is to meet customers demand for blood components as efficiently as possible. Blood centers work hard to meet demand. However, because demand can be volatile, they often do so at a high cost. Changes in demand can create a need for costly imports or leave an excess supply with no available export options. Terumo BCT solutions and services work together to help enable blood centers to respond quickly and efficiently to changes in demand. This helps reduce costs and waste, while improving service to your customers and the patients they ultimately serve. 4

Increase flexibility of your collections and lab TSCD II sterile tubing welder The TSCD II device is a user-friendly tubing welder ideal for sterile connecting transfer bags, as well as a wide range of other lab applications. Designed for quality, reliability and flexibility, the TSCD II device creates closed system PVC connections using any combination of wet and dry tubing. Compact, lightweight and equipped with a pop-up handle, the TSCD II device is portable and can be easily moved. Terumo BCT s sterile tubing welders have been used extensively in labs and blood centers around the world for more than two decades. Today, our devices are indispensible for creating quick and safe PVC tubing connections while maintaining a functionally closed system. Applications include, but are not limited to: Component pooling Leukoreduction Collection set modification Component aliquoting Apheresis set modification Quality control sampling Cell washing and freezing 5

6

Connect PVC tubing in any combination of wet and dry tubing 7

The TSCD II device builds on the success of the TSCD Sterile Tubing Welder, adding several key features. new features include: Wet-to-wet welds: the TSCD II device is versatile Automatic wafer replacement: reduces risk of jams Redesigned clamp: heavy-duty, interconnected clamp simplifies operation LCD display: communicates the status of the welding process, provides error alerts, reports when wafer cassette is empty and disposal box is full Detachable shelves: for bag support Larger disposal box: for used wafers creates Strong, consistent welds Quickly connects PVC tubing in any combination of wet and dry including wet-to-wet with strong, smooth welds. All Terumo BCT sterile tubing welders are subject to minimum tensile strength requirements. guides operation An easy-to-read backlit LCD screen clearly displays device status and guides operators through the welding process. maintains closed system The TSCD II uses the same, single-feed wafers as the TSCD. Terumo Corporation s patented wafers heat to 572 F (300 C). This high temperature maintains sterility during cutting and welding but does not allow particulates or chemical residue to form in the tubes. Automates wafer feed Eliminates the need to manually replace wafers and reduces the risk of wafer jams. The information panel alerts operators when the wafer cassette is empty and the wafer disposal box is full. monitors wafer disposal box Wafers are automatically discarded after a single use into a built-in disposal box to avoid cross contamination. An integrated sensor reduces the risk of jams by alerting operators when the disposal box is full and disabling operation until the box is emptied. The wafer disposal box holds 300 used wafers. simplifies operation Durable materials stand up to intensive use while the interconnected clamp design enables fast, one-handed operation. enhances portability This lightweight device includes a built-in handle. 8

System Specifications TSCD II Terumo Sterile Tubing Welder Model Tubing material 3ME-SC203A Polyvinyl Chloride (PVC) Tubing size Wafer Power supply External dimensions width x height x depth Weight Weld cycle Outer Diameter: 03.86 mm 04.60 mm 0.152 in 0.181 in TSCD Wafer, Product Code 1SC*W017v AC 100 V AC 240 V, 3A 50 60 Hz 224 mm x 177 mm x 342 mm 9 in x 7 in x 13 in Approximately 6.5 kg (14.33 lbs) Approximately 1 weld every 14 seconds Blood Bag Type Tubing Wall Thickness: 0.508 mm 0.800 mm 0.019 in 0.031 in Accessories Operating Conditions Ambient temperature Humidity Altitude AC power cable, bag supports, fuses (250V/4.0A), cassette of TSCD wafers and operating instructions The instrument should be allowed to equilibrate at these conditions before use 10 C to 40 C (50 F to 104 F) 10% to 80%, RH non-condensing Up to 3,658 meters maximum (12,000 ft) Storage Conditions Ambient temperature Humidity 10 C to 50 C (14 F to 122 F) 10% to 95%, RH non-condensing TSCD II sterile tubing welder is manufactured and distributed by Terumo BCT, Lakewood, CO, USA. TSCD is a registered trademark of Terumo Corporation, Japan. 9

Take command of demand with the TSCD II. Contact your Terumo BCT representative today. 10

Terumo BCT, Inc. USA 10811 West Collins Ave. Lakewood, Colorado 80215-4440 USA USA Phone: 1.877.339.4228 Phone: +1.303.231.4357 Fax: +1.303.542.5215 Terumo BCT (Asia Pacific) Ltd. Room 3903-3903A, 39/F ACE Tower, Windsor House 311 Gloucester Road Causeway Bay, Hong Kong Phone: +852.2283.0700 Fax: +852.2576.1311 Terumo BCT Japan, Inc. 20-14, 3-chome Higashi Gotanda, Shinagawa-ku Tokyo, 141-0022 Japan Phone: +81.3.6743.7890 Fax: +81.3.6743.9800 Terumo BCT Europe N.V. Europe, Middle East and Africa Ikaroslaan 41 1930 Zaventem Belgium Phone: +32.2.715.05.90 Fax: +32.2.721.07.70 Terumo BCT Latin America La Pampa 1517 12th Floor C1428DZE Buenos Aires Argentina Phone: +54.11.5530.5200 Fax: +54.11.5530.5201 UNLOCKING THE POTENTIAL OF BLOOD TERUMOBCT.COM 2013 Terumo BCT, Inc. / PN 306620784