Summary. Structure Tech Home Inspections Raleigh Avenue South Saint Louis Park, MN Customer New Buyer

Similar documents
Canadian Property Inspections

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Home Inspection Report

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc.

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

Excellent Home Inspection Services, LLC

I. STRUCTURAL SYSTEMS

Axiom Property Inspections

Extra Mile Inspection, Inc.

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

fieldwork report contains the Functional

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

El 0. El 0. El El. El El. El 0 TWO FAMILY HOUSING INSPECTINO CHECKLIST

Inspection Report 123 My Street Midland, GA

CMHC HOME MAINTENANCE CHECKLIST

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

Inspection Report. Eagle Eye Home Inspectors. John R. Dixon 24GI McKinley Court Princeton, NJ

Inspection Report. Mr. and Mrs. New Owners. Property Address: 123 Nowhere St ANYWHERE FL 32025

Inspection Report. Eagle Eye Home Inspectors. John R. Dixon 24GI McKinley Court Princeton, NJ

RW West Consultants. Property Inspection Report

Inside Out Home Inspections

The Ultimate Home Inspection Checklist

Inspection Report. Inspection Date: 1/1/2011. MultiFamily Sample. Property Address: Street Address. City NJ Zip. All In One Home Inspection LLC

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd.

Home Maintenance Schedule

Inspection Report. Jane Doe. Property Address: 123 Anywhere Montgomery AL Central Alabama Property Inspections

Inspection Report. Property Address: XXXX Sondrio Dr Las Vegas NV Skye Canyon Home Inspection Services

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

Canadian Property Inspections

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

Home Inspection Report

Troy's Home Inspection Services LLC

Jeff Brown Inspections

Inspection Summary. Canyon State Property Inspections 3114 South 98th Street Mesa, AZ (480)

Watson Home Inspection Services, LLC.

The Home Inspector Alaska LLC Donna Ranson Certified Inspector Cell:

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

Cascade Inspection Services, LLC

Inspection Report. Prepared For: Joe Smith. Property Address: 1234 Slick Lane. #2 Chicago, IL. Inspectrum Inc.

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

PREPARED FOR: (Name of Client) CONCERNING: (Address of Property) BY: P Home. YOUR HOME CHECK 1305 FM 359, Suite G F

Home Inspection Report Michael Smith

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

Terry Building Inspection report summary with all items addressed or explained in red

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

Inspector FX Field Forms

SUMMARY 1234 Main St.Edmonton AB T5T3E9 Buyer Name 07/05/2018 9:00AM

Home Inspection Report

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

Residential * Commercial * Mobile Homes * New Construction

FAIRA TRANSPARENCY REPORTS. November 21, 2016

74xx K. St. sample actual insp.w/photos, Edina, MN 5543x

McKinney Inspection Company

Tennessee Valley Property Inspections

FAIRA TRANSPARENCY REPORTS S 248th Pl, Des Moines, WA March 12, 2018

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

Home Set-up and Maintenance. Maintenance

Habitability Guidelines

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

Inspector Gadget Homes

Inspection Report. Cheri Maisonneuve. Property Address: 103 Dogleg Dr Moultrie GA. Welcome Home! Premier Home Inspections of Valdosta, LLC

FAIRA TRANSPARENCY REPORTS S 237th St, Kent, WA November 28, 2017

All In One Home Inspections

Bayshore House Inspections LLC

ce Is the Key Seasonal Home Maintenance Inspecting help keep live. help you. person to round: snow or debris. test button, which should then cause the

HOME INSPECTION REPORT

FAIRA TRANSPARENCY REPORTS th Dr NE, Lake Stevens, WA April 4th, 2017

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

Inspection Report. Mr. John Smith. Property Address: Main St Victorville CA Schultz Property Inspections. Wayne Schultz - (760)

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

20/20 Home Inspections. Photo Attachments

FAIRA TRANSPARENCY REPORTS Harbour Pointe Blvd, #301h, Mukilteo, WA 98275

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017

Montgomery County Land Bank PRE SALE INSPECTION REPORT

FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017

Inspection Report. Rob Renfro. Property Address: 1234 Main St. Auburn WA Coastline Home Inspections

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

Inspection Report. Inspection Date: 5/1/2010. Single Family Sample Report. Property Address: Address. City State Zip. All In One Home Inspection LLC

Code Compliance Report

MAISON INSPECTIONS

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

BISHOP HOME INSPECTIONS, LLC. Phone (269) / Fax (269) / Website: bishophomeinspection.

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

HVAC Equipment Access Equipment Location

TABLE OF CONTENTS. Part I Administrative... 1

Doyle Home Inspections

FAIRA TRANSPARENCY REPORTS th Ave NE, Seattle, WA August 23 rd, 2017

Transcription:

Summary Structure Tech Home Inspections 4205 Raleigh Avenue South Saint Louis Park, MN 55416 www.structuretech1.com 612-205-5600 Customer New Address 12345 Super Happy Street Minneapolis MN This Summary Report includes the items that were, in my opinion, the most important items to bring to your attention. This is not by any means a substitute for the full report. Please read the entire report. 5. Electrical General Summary 5.2 Exterior Electrical The clamps at the service entrance conductors weren't properly insulated, which is a shock hazard. If someone touched them, they would get shocked or electrocuted. Have the utility company correct this. 5.5 Interior Electrical (1) There were several ungrounded three prong outlets present, indicated in the photos below. These are potential shock hazards, and can allow equipment that is plugged into these outlets to be damaged. Have the wiring corrected. (2) There was reversed polarity to the north wall outlet in the northwest bedroom. This means that the hot and neutral wires have been wired backwards at some point in between or at the main service panel and the outlet. This is a shock hazard. Have the wiring repaired. 9. Interior General Summary 9.1 Fireplaces (1) There was exhaust gas leaking back into the home at the gas fireplace, and there were high levels of carbon monoxide in the flue gas - over 400 parts per million. This is a safety hazard. Have the gas fireplace repaired before using it. (2) The wood burning fireplace had a gap between the smoke shelf and the first section of clay liner. This area must be tightly sealed to help prevent the passage of heat and smoke into the wood framed wall, which could start a fire.

There were also cracks in the flue liner that should be repaired before the fireplace is used. The smallest cracks can expand under thermal pressure to create a fire hazard. Have the wood burning fireplace repaired by a CSIA Certified Chimney Sweep before using it. 10. Attic General Summary 10.0 Exhaust Fans & Ducts (1) The kitchen exhaust fan was vented into the attic, which causes all of the warm, moist air to discharge into the attic space, rather than to the exterior. This can cause a long list of problems with the attic, including rotted roof sheathing, frost in the attic, grease in the attic, and ice dams. The kitchen exhaust fan needs to have ductwork installed that is airtight, insulated, and continuous to the exterior. Have this corrected. 11. Garage General Summary 11.2 Fire Separation There were voids in the garage / house wall, extending the entire width of the house, that should be repaired, in order to maintain the necessary fire separation between the garage and the living quarters. The wooden hatch cover to the attic area should be sheathed with metal or drywall in order to maintain the proper fire separation between the garage and the living quarters. This is to slow the potential spread of a fire. Have this fixed. Licensed To Reuben Saltzman 12345 Super Happy Street Page 2 of 33

Inspection Report New Property Address: 12345 Super Happy Street Minneapolis MN Structure Tech Home Inspections Reuben Saltzman and Bill Oelrich 4205 Raleigh Avenue South Saint Louis Park, MN 55416 www.structuretech1.com 612-205-5600 12345 Super Happy Street Page 3 of 33

Table of Contents Summary... 1 Cover Page... 3 Table of Contents... 4 Intro Page... 5 1 Roof Covering... 6 2 Chimney... 6 3 Exterior... 6 4 Basement / Foundation / Structure8 5 Electrical... 8 6 Plumbing... 17 7 Heating... 23 8 Cooling... 25 9 Interior... 25 10 Attic... 28 11 Garage... 32 12 Environmental... 33 12345 Super Happy Street Page 4 of 33

Date: 9/21/2015 Time: 09:00 AM Report ID: Property: 12345 Super Happy Street Minneapolis MN Customer: New Real Estate Professional: The service recommendations that we make in this report should be completed by licensed, qualified, competent specialists, who may well identify additional defects or recommend some upgrades that could affect your valuation of the property. This inspection was conducted in accordance with the ASHI Standards of Practice, which can be viewed online at http://www.structuretech1.com/ashi-sop.pdf This report is the exclusive property of Structure Tech Home Inspections and the Client whose name appears within, and its use by any unauthorized persons is prohibited. Style Of Building: Single Family Number of Stories: One Type Of Construction: Wood Frame Home Faces: South Furnished: Yes Occupied: Yes Year Built: 1960 Square Feet: 2188 Weather: Clear and Dry Temperature: 65-70 Degrees Present At Time Of Inspection: s 12345 Super Happy Street Page 5 of 33

1. Roof Covering The inspection of the roof includes the roofing materials, the roof drainage systems, the flashings, skylights, chimneys, and roof penetrations. Items 1.0 Sloped Roof Acceptable Roofing Material: Architectural Shingles Inspection Method: Walked surface 2. Chimney The inspection of the chimney includes the vent and system components. Items 2.0 Chimney Crown The chimney crown was cracked. These cracks will allow water into the chimney and should be sealed to help prevent damage to the chimney. 3. Exterior The inspection of the exterior includes the siding, flashing, trim, all exterior doors, decks, balconies, stoops, steps, porches, and guardrails. It includes eaves, soffits, and fascias that are accessible from the ground level. This also includes vegetation, grading, surface drainage, and retaining walls that are likely to adversely affect the building. This also includes adjacent entryway walkways, patios, and driveways. Items 3.0 Drainage & Grading Acceptable 3.1 Windows Comment There were screens missing from several windows, but there was a large group of screens stored in furnace room. Ask to have the screens installed for the pre-closing walk-through. This allows the opportunity to verify screens were present at all of the windows, that they fit properly, and were all in acceptable condition. 12345 Super Happy Street Page 6 of 33

3.2 Vent Terminals / Intakes There were two abandoned bath or dryer vent terminals at the north side of the house. The damper was open on one which will allow for cold air to come in house. Have both vent terminals properly sealed at the exterior. 3.3 Exterior Faucet(s) The frost-free faucet at the front side of the house was improperly installed; if the faucet doesn't slope downwards towards the spout, the water won't drain out when the faucet is turned off. If the water doesn't drain out, it has the potential to freeze and destroy the faucet, or possibly cause a leak from a burst pipe inside the house. Have this installation repaired. For more info about this specific defect here: http://www.structuretech1.com/2012/01/how-toprevent-outside-faucets-from-freezing/ 3.4 Exterior Faucet(s) There was no backflow prevention device at the front exterior faucet pictured below. These are required to protect the potable (drinking) water supply from contamination. Add a vacuum breaker at the exterior faucet. For more information on this topic, click here: Why do I need a backflow preventer? 12345 Super Happy Street Page 7 of 33

Siding: Wood Lap / Clapboards 4. Basement / Foundation / Structure The inspection of the structural components includes the foundation and framing. Items 4.0 Signs of Moisture Comment There were no visible signs of moisture in the basement. 4.1 Sump System Comment There was no sump system present. 4.2 Limitations Comment The basement was mostly finished. The concealed components in the finished areas could not be inspected, such as the basement floor, foundation walls, floor structure, etc. Wall Structure: Wood Studs Crawl space inspection method: No crawl space present Floor Structure: Conventional wood framing Foundation: Concrete block Ceiling and roof structure: Conventional framing Unfinished basement insulation: Foundation walls: not insulated Rim space: fiberglass batts 5. Electrical The inspection of the electrical system includes the following: the service drop; the service entrance conductors, cables, and raceways; service equipment and main disconnects; service grounding; interior components of service panels and subpanels; conductors; overcurrent protection devices; a representative number of installed lighting fixtures, switches, and receptacles; ground fault circuit interrupters and arc fault circuit interrupters. 12345 Super Happy Street Page 8 of 33

Items 5.0 Main Panel Comment The main panel did not have thirty-six inches of clear space in front of it, which is the minimum required working space. 5.1 Service Grounding & Bonding The main electric service was only grounded to the water distribution piping in the same room as the panel. For added safety, I recommend having this main panel grounded to the water piping coming into the home before the meter, including a ground jumper. 12345 Super Happy Street Page 9 of 33

5.2 Exterior Electrical Unacceptable The clamps at the service entrance conductors weren't properly insulated, which is a shock hazard. If someone touched them, they would get shocked or electrocuted. Have the utility company correct this. 5.3 Exterior Electrical Comment The front yard light did not function. This may be the result of a burned out bulb, the light could be controlled by a photoelectric sensor, or there may be a problem with the wiring. Try replacing the bulb first. 5.4 Unfinished Areas (1) There was an open electrical splice in the attic, which is a potential fire hazard. Splices need to be made inside of junction boxes to contain any arcing or sparking which could occur. Have this repaired by an electrician. 12345 Super Happy Street Page 10 of 33

(2) There was one improperly terminated cable in the attic, which is a potential shock and fire hazard. Remove this cable or have it properly terminated inside a box. (3) There was a bare bulb light in the basement closet, creating a potential fire hazard. Install a light with a protective globe. (4) There was some NM cable (or Romex) that was improperly stapled to the bottom of the floor joists; this size wire should be fed through bore holes in the floor joists, not mounted underneath. 12345 Super Happy Street Page 11 of 33

5.5 Interior Electrical (1) There were several ungrounded three prong outlets present, indicated in the photos below. These are potential shock hazards, and can allow equipment that is plugged into these outlets to be damaged. Have the wiring corrected. North living room wall North living room wall east wall, NE bedroom South wall, NE bedroom 12345 Super Happy Street Page 12 of 33

1st floor bathroom NE bedroom Basement office room (2) There was reversed polarity to the north wall outlet in the northwest bedroom. This means that the hot and neutral wires have been wired backwards at some point in between or at the main service panel and the outlet. This is a shock hazard. Have the wiring repaired. 12345 Super Happy Street Page 13 of 33

(3) The surface mounted non-metallic cable under the kitchen sink should be protected in a metal raceway or something similar to help prevent physical damage. This was not done. (4) The non-metallic cable for the garbage disposer at the kitchen sink should be protected in a flexible metal conduit and secured at the disposer, to help prevent damage to the wire from items being moved under the kitchen sink. Have the wiring to the disposer re-done for safety. 5.6 GFCI Devices (1) The kitchen countertop, basement bathroom, unfinished basement and garage outlets were not GFCI protected. Add GFCI protection for these outlets to lower the risk of a lethal shock. 12345 Super Happy Street Page 14 of 33

north wall kitchen basement bathroom 12345 Super Happy Street Page 15 of 33

furnace room laundry room original garage, north wall (2) The GFCI outlet in the basement office room tripped, but did not lose current. This is not a location that requires GFCI protection, however, the outlet was not grounded, and our recommendation is to correct the wiring. 5.7 Smoke Alarms 12345 Super Happy Street Page 16 of 33

The only smoke alarms present were the ionization type, which may not give occupants enough warning in the event of a smoldering fire. For increased safety, replace all the existing smoke alarms with photoelectric smoke alarms. For more information on this topic, click here: Photoelectric smoke alarms are all you need. 5.8 CO Alarms Acceptable Service Amperage: 100 amps Predominant Branch Circuit Wiring: Non-metallic sheathed cable (Romex) Location of main disconnect(s): Basement Utility room north wall Main panel type: Circuit Breaker Location of subpanel(s): None Note: we do not test the operation of smoke and carbon monoxide alarms. These devices should be tested monthly by the occupants of the home by pressing the built-in test buttons on the devices. AFCI devices are tested by using the internal test buttons on AFCI devices at vacant buildings only. Click the following link for more information on this topic: AFCI devices 6. Plumbing The inspection of the plumbing system includes the following: the water supply and distribution system, including all fixtures and faucets; the drain, waste and vent systems including all fixtures; the water heating equipment and hot water supply system; vent systems, flues, and chimneys; fuel storage and fuel distribution systems; drainage sumps, sump pumps, and related piping. We DO NOT operate water supply / shut-off valves. For the washing machine and dryer, we perform only a cursory test for the basic operation of the appliances. For instance, we'll check to make sure the dryer turns on with normal controls and listen to make sure it sounds like the tumbler is turning, but we do not check the accuracy of the dryer thermostat, moisture sensor, timers, or do any type of testing on similar features. Items 6.0 Water Distribution Piping There was a saddle valve present to supply water to a whole house humidifier, but the humidifier has since been removed. Saddle valves are not approved for use in Minnesota and are prone to leakage. This saddle valve was heavily corroded and should be removed, and the pipe repaired. There was also a saddle valve present for the ice maker; try to avoid operating that valve. 12345 Super Happy Street Page 17 of 33

6.1 Water Heater (1) The temperature and pressure relief valve at the water heater leaked, and should be replaced. If the valve leaks again after replacing it, this would need further evaluation by a plumber to help determine the cause for the leaking. For more information on this topic, click here: Why The Relief Valve at the Water Heater is Leaking (2) The hot water coming out of the faucets was measured at approximately 135 degrees, which can cause scalding very quickly. The temperature of the water shouldn't be higher than 120 degrees at any of the faucets. To reduce the risk of scalding, turn the temperature down at the water heater. Be aware, however, that this will increase the potential for Legionellae Bacteria growth. To minimize the risk of scalding and bacteria growth, have a tempering valve installed. For more info on this topic, click here: Water Heater Temperature. 6.2 Clothes Washer/Dryer The dryer was functional at the time of inspection. The front loading washing machine has a rubber gasket that can build up with mold growth. Keep the door open a crack when not using it to keep the gasket dry. Clean it now. The washing machine leaked at the front door, and should be serviced. 12345 Super Happy Street Page 18 of 33

6.3 Dryer Duct The dryer duct consists of a semi-rigid aluminum material that was improperly spliced using duct tape and clamps at the joint pictured. This material also does not return to its original shape when dented. Dents impede air flow and could potentially lead to a fire from lint accumulation Flexible material should only be used to connect the dryer to the rigid metal duct; never as a substitute for metal ductwork. Have the flexible material replaced with smooth metal to lower the potential for a fire. 6.4 Floor Drains There was a loose cleanout plug at the floor drain, which will allow hazardous, smelly sewer gases to enter the home. Secure the cleanout plug or have it replaced with a tight-fitting plug. For more detailed information on this topic, click here: Floor Drain Basics 12345 Super Happy Street Page 19 of 33

6.5 Laundry Sink (1) There was no backflow prevention device on the threaded laundry faucet, which is required to protect the city's potable (drinking) water supply from potential contamination. Add a vacuum breaker (aka - backflow preventer). For more info on this topic, click here: Cross-Connections at Utility Sinks The sink was dented from below causing a high spot in the middle of the sink. This "ridge" prevents water from completely draining. Repair the dent to allow the sink to drain properly. (2) There was a leak at the laundry sink drain that should be repaired. ponds in circle, line represents ridge 12345 Super Happy Street Page 20 of 33

6.6 Fuel Lines Comment There was an old gas valve installed at the furnace, which tends to stick or leak with age. When this appliance is replaced, the gas valve should also be replaced. 6.7 Bathroom Sinks The mechanical sink stopper in the first floor bathroom did not function and will need to be serviced to work properly. 12345 Super Happy Street Page 21 of 33

6.8 Bath Tub(s) / Shower(s) Comment The bath tub in the basement bathroom was a deck mount type of bath tub, but it was installed right up against the wall. This is an improper installation that will be prone to leakage at the wall. There is no practical repair for this, short of tearing out the tub and starting over. There were signs of historical leakage behind the tub, but the wood was dry at the time of the inspection. To help prevent future leakage at the tub / wall intersections, keep them well sealed with caulk. 6.9 Kitchen Sink The dishwasher drain did not have a proper high loop to prevent water from siphoning back into the dishwasher. This could lead to a cross-connection with the city water supply or a clogged dishwasher drain hose. Raise the dishwasher drain hose to match the diagram below. To read more about this specific issue, click here: high loop at dishwasher drain. 12345 Super Happy Street Page 22 of 33

6.10 Water Softener Comment The photo below shows a hardness test strip, taken from cold water at the laundry sink. Water distribution pipes: Copper Water heater age: Approximately 4-5 years old Drain Waste and Vent Pipes: Copper Main water shut-off valve location: Basement south wall Water heater type: Electric - storage tank Main gas shut-off valve location: Meter at exterior east wall 7. Heating The inspection of the heating system includes any installed heating equipment and their vent systems, flues, and chimneys. Any readily openable access panels are also opened. Items 7.0 Operation / Condition Comment 12345 Super Happy Street Page 23 of 33

The furnace responded properly to the thermostat controls and had a low level of carbon monoxide in the flue gas. Have the furnace serviced and inspected annually. For information about why we recommend annual furnace inspections, click here: Are Annual Furnace Inspections Really Necessary? The furnace was at or near the end of its service life expectancy. 7.1 Furnace Filter Comment The cover was missing to the air filter. Install a tight cover to help prevent air in the basement from being pulled into the return air duct. This can cause excessive air pressure at the upper levels, which can lead to excessive air leakage from the house to the attic, which leads to frost in the attic and can contribute to ice dams. 7.2 Vent Connector & Vent Comment The furnace vent connector lacks the required clearance to combustibles. The double-walled vent connector should be one inch away from the drywall and wood framing. 7.3 Combustion Air 12345 Super Happy Street Page 24 of 33

There was no combustion-air duct in the furnace room. These are essential to support complete combustion, and without them carbon monoxide could be produced and pose a threat to the occupants. Have a combustion air duct installed. For more information on combustion air ducts, click here http://www.structuretech1.com/blog/?p=67 Heating System: Forced Air Age of heating system: Approximately 18-19 years old 8. Cooling The inspection of the air conditioning consists of the central and through-wall equipment (but not window units), as well as the distribution systems. Any readily openable access panels are also opened. Items 8.0 Operation / Condition Acceptable Cooling method: Forced air split system, electric Cooling age: Less than one year old 9. Interior The inspection of the interior includes the following: walls, ceilings, and floors; steps, stairways, and railings; countertops and a representative number of installed cabinets; a representative number of doors and windows. Installed ovens, ranges, surface cooking appliances, microwave ovens, dishwashing machines, and food waste grinders are inspected by using normal operating controls to activate the primary function. Items 9.0 Windows Comment The center and west bedroom windows do not meet today's egress requirements for new windows. The current size requirement for an egress window is that it opens at least 24" high, 20" wide, and has a net clear opening of at least 5.7 square feet. Additionally, the bottom of the window can not be more that 44" from the ground and can not require special tools or knowledge to open. This is not a major concern, as the windows had large enough openings for most people to climb through in the event of an emergency. 12345 Super Happy Street Page 25 of 33

9.1 Fireplaces (1) There was exhaust gas leaking back into the home at the gas fireplace, and there were high levels of carbon monoxide in the flue gas - over 400 parts per million. This is a safety hazard. Have the gas fireplace repaired before using it. (2) The wood burning fireplace had a gap between the smoke shelf and the first section of clay liner. This area must be tightly sealed to help prevent the passage of heat and smoke into the wood framed wall, which could start a fire. There were also cracks in the flue liner that should be repaired before the fireplace is used. The smallest cracks can expand under thermal pressure to create a fire hazard. Have the wood burning fireplace repaired by a CSIA Certified Chimney Sweep before using it. 12345 Super Happy Street Page 26 of 33

(3) The wood burning fireplace hearth extension did not have standard dimensions, which would require it to extend at least twenty inches from the front of the opening, and eight inches on either side, as the fireplace opening was over 6 sf. This is needed to help prevent a spark from landing on the floor and starting a fire. Have this corrected before using the fireplace. (4) There was a white haze on the glass at the gas fireplace. For information on how to clean the glass, click here. 9.2 Kitchen Appliances The range was functional. The range was missing an anti-tip device, which is needed to help prevent the range from accidentally tipping over. This is an important safety device that should be installed. 12345 Super Happy Street Page 27 of 33

9.3 Kitchen Appliances Comment The dishwasher was functional. I ran the dishwasher through a rinse cycle only. The water drained out of the dishwasher and there were no leaks. The garbage disposal was functional. The microwave was functional. The refrigerator was functional. Interior limitations: Occupied Fireplace Description: Wood burning masonry fireplace Masonry fireplace with gas insert 10. Attic The inspection of the attic(s) includes the insulation, ventilation, and vapor retarders where visible. This includes kitchen, bathroom, laundry and similar exhaust systems, and clothes dryer exhaust systems. Items 10.0 Exhaust Fans & Ducts Unacceptable (1) The kitchen exhaust fan was vented into the attic, which causes all of the warm, moist air to discharge into the attic space, rather than to the exterior. This can cause a long list of problems with the attic, including rotted roof sheathing, frost in the attic, grease in the attic, and ice dams. The kitchen exhaust fan needs to have ductwork installed that is airtight, insulated, and continuous to the exterior. Have this corrected. 12345 Super Happy Street Page 28 of 33

(2) There was no insulation on the bath fan exhaust duct. Replace the duct with an insulated duct to reduce heat loss and potential ceiling damage from condensation. 10.1 Attic Insulation (1) Attic insulation consists of fiberglass batts installed on top of a few inches of loose fiberglass. The batts have been somewhat haphazardly installed, leaving large gaps in the insulation all over the attic. These gaps equate to an exponential level of heat loss through the attic space. Because of how difficult it is to properly install fiberglass batts, I recommend removing the batts and having the attic re-insulated with loose-fill insulation. This will help to reduce energy loss and lower the potential for ice dams. For information about the importance of evenly distributed insulation in the attic with no gaps, click here. 12345 Super Happy Street Page 29 of 33

Insulation at the eaves was minimal, which will allow for significant heat loss at the top wall plates. To reduce the heat loss here, you would need to have a different type of insulation installed at this location, such as closed cell foam. You can read more about this by clicking here: Insufficient Insulation at Eaves. (2) There were inadequately insulated recessed lights in the attic. Install insulated boxes over the recessed lights to prevent heat from entering the attic and increasing the potential for ice dams. 12345 Super Happy Street Page 30 of 33

10.2 Air Leaks / Bypasses There were attic air leaks that should be sealed to help prevent conditioned household air from entering the attic space. Attic air leaks allow moisture into the attic which shows up as frost, can reduce the effectiveness of insulation by as much as 70%, and are a major contributor to ice dams. Have the attic bypasses sealed by a qualified insulation contractor. For information about where to find these attic air leaks and how to correct them, download this Guide to Attic Air Sealing. While there are specific issues addressed in this inspection related to home energy and building performance, correcting one issue has the potential to create a new problem if not done properly. Before having any insulation or air sealing repairs / upgrades performed at the home, I recommend you read this Building Envelope Guide from the Minnesota Office of Energy Security, and recommend you have a whole house energy audit performed. This audit should include a blower door test and infrared scan at a minimum, and may also include a radon test. Doing so will help you to prioritize your energy improvement needs, and will help minimize the potential for creating new problems. kitchen hood terminates in attic hole in bath fan duct 12345 Super Happy Street Page 31 of 33

Attic inspection method: Entered attic Attic insulation: Loose fill fiberglass Fiberglass batts Vapor barrier: None present 11. Garage The inspection of the garage includes the garage doors and garage door operators. Items 11.0 Overhead door(s) Acceptable 11.1 Garage door opener(s) The wall button for the garage door opener was less than five feet high, which is the minimum required height to help prevent small children from operating the opener. Raise the opener button for safety. 11.2 Fire Separation There were voids in the garage / house wall, extending the entire width of the house, that should be repaired, in order to maintain the necessary fire separation between the garage and the living quarters. The wooden hatch cover to the attic area should be sheathed with metal or drywall in order to maintain the proper fire separation between the garage and the living quarters. This is to slow the potential spread of a fire. Have this fixed. 12345 Super Happy Street Page 32 of 33

drywall stops short of roof sheathing 12. Environmental Environmental items included in this section are specifically excluded by our standards of practice as well as our inspection agreement, but may be noted here as a courtesy, or as a convenience if additional testing was conducted at the same time as the home inspection. Items 12.0 Radon Comment The EPA protocol average for the radon test was <2.0 pci/l (1.2), which is considered a low test. For more info on the test results, click here: Radon Testing: What the Results Mean. 12.1 Vermin Comment There were mouse traps present under the kitchen sink. These usually indicate rodent problems. 12345 Super Happy Street Page 33 of 33