Smoke ventilation. Complete smoke ventilation solutions for all building types

Similar documents
FlexiSmoke WSC 520 / WSC 540 / WSC 560 Modular smoke ventilation panel 20-60A

Version 4 Controls for smoke and natural ventilation. CompactSmoke WSC 310 / WSC 320 PLUS Smoke control panel 10-20A

Version 3 Controls for smoke and natural ventilation. CompactSmoke WSC 310 / WSC 320 STANDARD Smoke control panel 10-20A

FlexiSmoke WSC 520 / 540 / 560. Utilization examples

Product catalogue

Version 3 Controls for smoke and natural ventilation. WLS xxm Smoke control panel LON MotorLink

WSC 204 (WSC / WSC 204MH 0102 / WSC 204KP 0102 / WSC 204BZ 0102)

THE SMOKE MUST GO. Consulting - Project Planning - Supply - Installation - Service

Uniclass L7535 EPIC L13. CI/SfB (57) X. secontrols.com. Smoke Ventilation, Natural Ventilation and Window Automation

Underfloor Catalogue Heating products that define the market

Uniclass L7535: N3253 EPIC L13:Y42. CI/SfB (57) X (K5) Residential Smoke Ventilation

Electronic controllers. Comfort embellishes everyday life

Smoke Vents. Certified to CE EN Roof Access Systems

INTELLIGENT VENTILATION CONTROLS NATURAL AND HYBRID PLUS SYSTEMS

Schueco Fire and Smoke Protection Systems

INTELLIGENT VENTILATION CONTROLS: NATURAL AND HYBRID SYSTEMS

V3 Intelligent Damper Control and Monitoring System

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

WINDOW AUTOMATION SOLUTIONS NATURAL AND SMOKE VENTILATION SYSTEMS

Fire protection documentation. CFPA-E Guideline No 13:2015 F

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Kædemotorer. Product Overview

THE SMOKE AND ACCESS SPECIALISTS. Compliance without compromise

Actionpac 60/120 (LNS Standard)

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

U C S AND AUTOMATION SYSTEMS

Smoke Vent Control Panel PCB4 V4 Installation Manual

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

NOXSYS A SYSTEM FOR THE HIGHEST LEVEL OF SECURITY

ES 200. Sliding door operator

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

VIII - Advanced capabilities of KNX systems

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

Your specialized partner for intelligent building technology

FIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED

B.E.G. PRESS KIT 2013

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Who are we? LGF SYSMAC a 15 Years Young and Vibrant Company Characterized by

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Performance Specifications LSF LIFT-SMOKE-FREE

TopGas Wall Hung Condensing Gas Boiler

Western Firex. Heat & Smoke Ventilator. EAGLE series Natural Ventilation

Applications for correctional facilities. Greater efficiency and cost-effectiveness with GAMMA building control. Answers for infrastructure.

Actionpac LNS3 Intelligent Damper Control and Monitoring System

Press Presse Press Presse

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

XC10 combined fire detection and extinguishing control

GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Reliably Advanced Extinguishing Control

ECO-MASTER DRYER DRYING CONVEYING DRYING SEED PROCESSING ELECTRONIC SORTING STORAGE TURNKEY SERVICE

K Series - Fire Suppression Systems for the Catering Industry

Kædemotorer. Accessories

SCHÜCO ALUMINIUM DOOR SYSTEM ADS 70

The Social Accountability International (SAI) Fire Safety Checklist

Loadstar AC/DC Systems

Moffitt Firex. Heat & Smoke Ventilator. MoffittCorp.com (800) th Ave S. Suite 130 Jacksonville Beach, FL

BX444-Mc Gas Detector

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

Product Information October (8) Orivent 51 in Itella, Pennala. Orivent 01 in Oriville factory, Orimattila

LAMILUX BUILDING CONTROL SYSTEMS ENERGY EFFICIENCY SAFE COMFORTABLE. Customized Intelligence Serving the customer is our first priority

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS

21-light Remote Annunciator. Owner s Manual

What extinguishes fires without pressure peaks?

SIMPLICITY OR FULL MODULARITY?

SAUTER ecos504/505. The modular room controller for demand-controlled, integral room automation.

Smoke Master SMPA Compact pressurisation system

technical specification smoke venting systems

Mechanical Smoke Extract Shaft Systems

Contents. Glossary

Catalogue. ActionpacEMSStandard. Electro Mechanical Control & Monitoring System.

Gas condensing boiler (wall mounted) TopGas

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

XC10 combined fire detection and extinguishing control

HART XL High Sensitivity Smoke Detection

October 2013 Bespoke Intelligent Damper Control and Monitoring System

VENTILATION = WELL-BEING

HART XL High Sensitivity Smoke Detection

SIMPLICITY FULL MODULARITY?

Specifying the Right Rooflight. T: +44 (0) E:

Automatic Sliding Door Systems

Fire Detection systems. UniVario industrial fire detectors for every job

CLIMATE SEPARATION SOLUTION. SensAir

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Key benefits. Why Condair CP3?

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

16 Zone Voice Evacuation VA & PA Sound System

C-Bus Application Note. Function Rooms and Ballrooms. Overview

Gas-fired unit heaters for indoor installation

Technical Information

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Fire / CO Alarm Interface

AUTOMATIC FIRE SUPPRESSION SYSTEMS

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Remote alarm unit Art. Nr.:

WHAT IS FIRE DISASTER? Fire Disaster is an occurrence or an incident of such magnitude which creates a situation in which the normal life is suddenly

Transcription:

Smoke ventilation Complete smoke ventilation solutions for all building types Passive smoke ventilation utilises natural driving forces for the efficient and rapid exhaust of smoke and heat from burning buildings

Glossary Passive smoke ventilation: smoke ventilation based on thermal buoyancy. This means that the hot smoke is ventilated away through high level openings (smoke vents) in the building. echanical smoke ventilation: smoke ventilation based on forced air movement using mechanical fans to force smoke and heat out of a building, e.g. via the duct system. ASV system: automatic smoke ventilation system whose purpose is to remove smoke and heat from a building. ASV includes smoke vents, smoke panel, automatic and/or manual control points. Alarm System: Fire or Smoke detection system, which is used to activate the installed automatic smoke ventilation system. It is often required that the alarm system provides a direct signal to the rescue service. Smoke vent: smoke ventilation opening located in or near the roof or high level facade to remove hot smoke in conjunction with passive smoke ventilation. EN12101-2: Standard used for type testing and CE certification of smoke vents. To comply with the fire standard EN12101-2 a smoke vent should carry a CE certification which means that a window and actuator have been tested and certified together and purchased as a complete unit. Replacement air: air supplied into the building via low level openings and should be activated simultaneously with the high level smoke vents. Openings for replacement air do not require CE certification. The volume of replacement air should be, as a minimum, equal to the amount of exhausted smoke. Aerodynamic free opening area: The total effective area of the openings which exhaust hot smoke. This area must be shown on the CE certificate on the smoke vent or calculated in line with local legislation or guidance. Smoke zone: is a smoke section a room or part of a room which is partitioned with smoke screens and/or walls. Legislation It is important to note that different countries and governing authorities have differing requirements for smoke ventilation in various building types. These requirements depend on whether the building is a new-build or renovation and apply to product choice, installation and subsequent inspection and testing. Windowaster has comprehensive experience in providing expert advice in the design, installation and servicing of smoke ventilation solutions. We have worked with a wide range of window and facade manufacturers to develop, test and certify solutions that meet the latest requirements laid down in European standard EN 12101-2. 2 Windowaster Solutions for an improved indoor climate

Why choose natural smoke ventilation? The majority of people who die in fires do not lose their lives because of the fire itself, but are suffocated by the smoke. It is therefore vital that the smoke is removed from the building as quickly as possible to allow everyone to escape and the fire brigade to extinguish the fire. By exhausting the smoke it ensures that the building does not overheat and that explosions of smoke gases, which can result in the entire building collapsing, do not occur. With a passive smoke ventilation solution the high level smoke vents (skylights, windows or proprietry smoke vents) will open automatically in conjunction with the low level replacement air openings. This system, when designed and controlled correctly, will ensure that the smoke is exhausted speedily, enabling the occupants to escape and therefore reducing the risk of fatalities. Solution examples 4 5 Smoke and comfort ventilation 5 FlexiSmoke 6 7 CompactSmoke 8 Accessories 9 Checklist 10 Service and maintenance 10 Selected references 11 Safety and a good indoor climate every day Smoke ventilation based on natural forces does not only create safety and security for the users of the building. The openings in the facade and roof can also be used every day to provide a pleasant indoor climate using comfort ventilation. Comfort ventilation is intelligent management of the indoor climate using natural ventilation which is both energy-saving and environmentally friendly. The system measures temperature and air quality in each room and, depending on the weather, opens windows as required to allow precisely the right amount of air into the building. This means that the safety solution is not just an investment in protection in the event of a fire or smoke incident, but it also becomes an active part of providing users with a balanced dayto-day indoor climate that is environmentally friendly. CompactSmoke is compact smoke control panels for smaller areas. They are available in 4-16A and contain one smoke ventilation group. FlexiSmoke is flexible, modular smoke control panels for larger areas. They are available in 20-60A with up to 39 smoke ventilation groups. Windowaster Solutions for an improved indoor climate 3

Solution examples Natural smoke ventilation can be installed in the majority of buildings. Example 1 shows how a simple smoke ventilation solution can be put together for a stairwell and example 2 shows how a more advanced solution can be implemented in a sports hall. Please contact our sales office who will be happy to help with your project see back of this brochure for contact details. Project example 1: Stairwell with combined smoke and comfort ventilation The stairwell comprises a basement and four further floors. The ground floor has an opening to take in replacement air, and the roof has a motorised skylight which is able to exhaust smoke from the stairwell if should it develop. At the very top there is a smoke detector. A keypad and a break glass unit has been installed on the top floor while a primary break glass unit has been installed on the ground floor. A wind and rain sensor has been mounted on the roof. All products are controlled from a smoke control panel located on the top floor. SOKE AND HEAT The following components have been used: 1 x smoke control panel set WSZ 204 6201 consisting of: 1 x CompactSmoke panel WSC 204 1 x smoke detector WSA 300 61 1 x actuator WU 885-1 0750 1 x bracket WAB 836H 1 x bracket WAB 836E 1 x primary break glass unit WSK 320 0002 61 1 x secondary break glass unit WSK 330 0002 61 1 x wind and rain sensor WLA 330 1 x keypad WSK 100 Symbole s: Keypad Wind and rainsensor Actuator Smoke detector REPLACEENT AIR Alarm system Alarm system break glass unit Smoke control panel 4 Windowaster Solutions for an improved indoor climate

Project example 2: Sports hall with smoke and comfort ventilation The sports hall comprises one large hall, an entrance area and a plant room. Each room constitutes an independent zone. Zone 1: Ten motorised skylights have been installed in the roof of the large hall. If smoke develops, these will remove the smoke from the hall. Low level replacement air openings ensure that the smoke is exhausted speedily. Zone 2: The entrance area has two motorised facade windows and a motorised skylight as well as three break glass units, one for each zone. Zone 3: The plant room has two motorised facade windows. Each zone has a break glass unit, smoke detector and manual override keypads. All products are controlled from a modular smoke control panel in the plant room which transmits information to an alarm system. A wind and rain sensor, which has been mounted on the roof over the entrance area, is used to close the windows when using comfort ventilation. The following components have been used: 6 x break glass units WSK 501 1 x actuator WU 885 single actuator 19 x actuators WU 836 single actuator 1 x FlexiSmoke panel WSC 540 4 x keypads WSK 100 6 x smoke detectors WSA 300 1 x wind and rain sensor WLA 330 ZONE 1 Hall ZONE 2 Entrance area ZONE 3 Plant room Alarm system Zo Zone Zone 19 Smoke and comfort ventilation Optimum indoor climate every day The principles behind our smoke and comfort ventilation solutions are the same. This means that a smoke ventilation system based on natural ventilation can be used to ensure a comfortable day-to-day indoor climate. Please contact us for further information about combinations of smoke and comfort ventilation. Our comfort ventilation solutions NV Solo : Our simplest solution for indoor climate control in a single zone/ room. Easy to install easy to operate. NV Comfort : Solution for heat control and natural ventilation in small and medium-sized buildings. The system can be extended to control sun screens, lighting and mechanical ventilation (hybrid ventilation). NV Advance : Our most advanced solution for the complete management of indoor climate in large buildings. The solution is tailored to the building and its surroundings. Windowaster Solutions for an improved indoor climate 5

Why choose FlexiSmoke? easy cabling using single bus Technology in connection with comfort ventilation bus communication via KNX, LON, BACnet or odbus is possible multiple opening speeds enable the actuators to run almost silently when used for comfort ventilation Smoke ventilation based on wind direction Flexible system structure Simple system adaptation in the event of renovation Configuration and troubleshooting with the integrated touch screen without the use of a PC. A PC can be connected without additional modules tested to the most recent standards, EN 12101-10 and pren 12101-9 60A WSC 560 FlexiSmoke 40A WSC 540 flexible, modular panels for smoke and comfort ventilation FlexiSmoke is our range of modular smoke control panels for the control of ±24V DC and otorlink window actuators in large and medium-sized buildings, e.g. shopping centres, schools and sports halls. 20A WSC 520 With the combination of several panels, FlexiSmoke can be used in very large buildings. All groups in the panel have been configured in the same way which means that each group can easily be set for smoke and/or comfort ventilation. A 3½ LCD touch screen means that installation, configuration and maintenance can be managed without the use of a PC. FlexiSmoke gives the possibility of up to three motor speeds depending of the type of motor: ±24V DC standard motor with one speed (H&S) motorlink motor with two speeds (H&S / manually operated) motorlink motor and buscommunication with three speeds (H&S / manually opereted / automatically) 6 Windowaster Solutions for an improved indoor climate

Easy initialisation Easy-to-read 3½ LCD touch screen makes the panel easy to configure, commission and maintain also without the need for a PC. System errors are described on screen to facilitate troubleshooting and initialisation. Ease of cabling The use of simple BUS technology for the break glass units means that the need for cabling in the building is significantly reduced. The bus can be initialised directly from the panel s touch screen. Smoke ventilation based on wind direction The smoke control panel can be set so that opening and closing of windows are determined by wind direction and speed. This means that facades can be utilised efficiently as part of the smoke ventilation without acquisition of additional modules aside from a wind direction sensor. Flexible system structure The modular smoke control panel can be constructed as required. It is easy to extend and reconfigure either by adding modules or by joining several panels. 1 Illustrative example FlexiSmoke can be connected to a number of components so that the controls can be adapted to the specific project. An example is shown here with three zones and component connections where the red lines are motor cables, while the blue lines show the unique bus-communication between the break glass units. otor group 1 otor group 2 otor group 3 otor line 3 otor line 4 otor line 1 otor line 2 Alarm system SOKE ZONE 1 SOKE ZONE 2 SOKE ZONE 3 See symbol description on page 4 For optional extras for the FlexiSmoke range please see page 9. Windowaster Solutions for an improved indoor climate 7

Why choose CompactSmoke? Financially competitive For smaller areas 4-16A A single smoke ventilation and comfort group Control of ±24 VDC actuators Incl. two emergency batteries Can be combined in master/slave connection 16A WSC 316 61 (VdS-No : G505012) 8A WSC 308 4A WSC 304 61 (VdS-No : G502028) CompactSmoke compact panels for smoke and comfort ventilation Our range of compact smoke control panels for the control of ±24V DC actuators is the right choice for small and mediumsized buildings such as stairwells and other single smoke zones. Each smoke control panel contains a single smoke/comfort ventilation group, but several panels can be joined in a master/ slave connection so that they can be used in larger buildings. 4.8A WSC 204 CompactSmoke is available in a range of models from 4 to 16 amps. Illustrative example CompactSmoke can be connected to a number of components so that the controls can be adapted to the specific project. An example is shown here with a single zone where the red lines are motor cables. ZONE 1 See symbol description on page 4 8 Windowaster Solutions for an improved indoor climate

Accessories for FlexiSmoke and CompactSmoke We supply complete smoke ventilation solutions and are able to offer all required modules and accessories. Please contact us if you have any special requirements. Smoke detectors On the occurrence of smoke, the smoke detector sends a signal directly to the smoke control panel and thereby activates the smoke ventilation system. Break glass units Break glass unit are available in several colours with and without audible signal. odules For the CompactSmoke we supply a wide range of modules for special functions as well as for extension and joining of smoke ventilation panels. For the FlexiSmoke we supply actuator modules as well as input-/output modules. Actuators Our actuators are available in a wide range of models and sizes and can in some cases be concealed in the window profile. The product catalogue contains both chain and spindle actuators with a stroke of 150-1000 mm which can be programmed for each window. Batteries 12-volt emergency batteries are available in various sizes and capacities depending on the chosen smoke control panel. Keypads A keypad on the wall enables the user to control the indoor climate manually, e.g. to open/close windows. The keypads can also be linked to other functions such as sun screening and lighting. Sensors Windowaster supplies several types of wind-/rain sensors for use in smoke and comfort ventilation. Furthermore, wind direction measurements make it possible to use the building s facades effectively as part of wind direction dependent smoke ventilation. Accessories Windowaster also supplies various accessories to the system, e.g. lock cylinders and additional keys. Windowaster Solutions for an improved indoor climate 9

Checklist What are the main considerations when choosing the right smoke ventilation solution? This list helps you on your way. You are, of course, always welcome to contact us we are happy to help. What are the statutory solution requirements? Remember to find out about smoke ventilation legislation related to your building type. Please note that the same legislation does not necessarily apply to new-builds and renovation projects. What are the parameters that need to be taken into consideration when choosing a smoke ventilation solution? The configuration of the final solution depends on the size of the building, the number of smoke vents, the window actuator ampage requirements and the number of smoke zones/rooms. How large should the opening area be? The required opening area depends on the size of the building and usage category which can often be found in the fire strategy report. The opening area that can be achieved depends on the size of the vents, the stroke of the actuators and the overall number of openings in the building. The aerodynamic free opening area is shown on the smoke vent s CE certificate. What actuator should you choose for the window used for replacement air? What type of smoke control panel should you choose and how many amps are required? The type of smoke vents (whether they are top-hung, bottom-hung, side-hung, open outwards or inwards, etc.), brand/profile range, frame dimensions, frame weight and pitch of roof for skylights affect the choice of suitable actuator. The choice of smoke control panel depends on the specific requirements of your building. For example, if you require several smoke ventilation groups, you should choose FlexiSmoke, which is a modular panel, or connect several CompactSmoke panels in a master/slave connection. How should the smoke control panel be activated? Activation of the automatic smoke ventilation system (the smoke control panel) can be done with a signal from a separate alarm system, smoke detectors and/or manual break glass units. Are accessories needed, e.g. for comfort ventilation? If the system is to be used in a combination of smoke and comfort ventilation, you may need accessories such as room sensors (temperature, CO 2, humidity), and keypads. Service and maintenance Regular inspection of smoke ventilation systems is a legal requirement. You must also have the system inspected and tested at fixed intervals. Windowaster offer maintenance agreements for both our own and other types of smoke ventilation systems. We inspect the complete system in accordance with the applicable legislation. aintenance of the smoke ventilation system includes checking windows, window actuators and emergency power and checking that triggering and control functions are fully functional. Please contact our service division for further information about how we are able to tailor a service agreement to suit your requirements. 10 Windowaster Solutions for an improved indoor climate

Selected references New Street Square Client: Consulting Engineers: &E Contractor: System : Land Securities Cundall N G Bailey A 730,000 sq ft mixed use scheme to replace a cluster of post-war offices with four contemporary buildings. Smoke ventilation system using cross ventilation, Windowaster supplied compact smoke panels to control over 2,000 actuators installed within the facade windows. West Quay, Newhaven Developer: Architect : Oakdene Homes plc organ Carn Partnership System : A 15 mixed development comprising of 105 luxury flats and 6 commercial units all looking across an existing natural marina. Windowaster supplied actuators for the facade windows and modular smoke panels to provide the life safety smoke ventilation system for each individal floor in the residential blocks. Radisson Blu Hotel, East idlands Airport Contractor : Bowmer & Kirkland Further references can be found at www.windowmaster.com Architect : Leach Rhodes Walker Roof domes: Lareine Engineering System : Windowaster supplied the compact control panels for the smoke ventilation system, controlling the automatic roof domes from Lareine Engineering. Windowaster Solutions for an improved indoor climate 11

Smoke ventilation safety and comfort every day Windowaster have more than 20 years experience of supplying smoke ventilation solutions that use natural ventilation to ensure efficient smoke and heat exhaust in the event of fire. FlexiSmoke and CompactSmoke, our two ranges of smoke control panel, can be combined with state-of-the-art technology and a wide range of window motors in tailored solutions for any kind of building. Windowaster s smoke ventilation solutions can also be combined with comfort ventilation to ensure that the building s users enjoy a comfortable indoor climate every day. Smoke ventilation based on natural ventilation UK +44 (0) 1536 510990 info@windowmaster.co.uk Other markets +45 4567 0300 info@windowmaster.com Windowaster 2012, 2013 Windowaster is a registered trademark used under license by Windowaster Group www.windowmaster.com We reserve the right to make changes.