Smoke is the most deadly part of a fire.

Similar documents
BuyLine /CON. apcdayliter. Fire and Smoke Vents. Smoke is the most deadly part of a fire

Moffitt Firex. Heat & Smoke Ventilator. MoffittCorp.com (800) th Ave S. Suite 130 Jacksonville Beach, FL

Western Firex. Heat & Smoke Ventilator. EAGLE series Natural Ventilation

PART 1 GENERAL 1.01 SUMMARY

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL

ARCHITECTURAL SPECIFICATIONS

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

UNDERSTANDING SAFETY CABINETS

SECTION FIRE EXTINGUISHER CABINETS

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperClear 45-HS (patent pending)

PART 1 GENERAL 1.01 SUMMARY

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS

SECTION AIR DUCT ACCESSORIES

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

Ballast Paver Design & Installation Guide

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

HEAT & SMOKE VENT INSPECTION AND MAINTENANCE PACKET

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

PART 1 GENERAL 1.01 SUMMARY

PART 1 GENERAL 1.01 SUMMARY

SECTION Overhead Coiling Doors

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

ICC CODE CORNER 2012 IFC Code & Commentary

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

SECTION FIRE PUMP AND CONTROLS

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

Fire Performance of Translucent Systems

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

Twin-Agent Fire Fighting/Securing Systems Specifications

Smoke Vents. Certified to CE EN Roof Access Systems

Submittal Data Performance Data Electrical Data

Code Technology Committee Area of Study Balanced Fire Protection Roof Vents

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

Questions related to specific materials, methods, and services will be addressed at the conclusion of the presentation.

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

OUTLINE FOR FIRE PREVENTION ACTIVITY

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

SECTION DUCTWORK

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

SECTION (15833) - HVAC POWER VENTILATORS

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

B. Section Identification for Fire Suppression Piping and Equipment.

Elements Headwall System (P2008A)

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

Flammable Liquid Storage

DIVISION FINNED WATER-TUBE WATER HEATERS

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

SECTION Fire Pumps

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Design & Construction Standards, Revised January

FINNED WATER-TUBE POOL HEATERS

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Pellet Vent INSTALLATION INSTRUCTIONS

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

TRANSLUCENT FIRE RATED SYSTEMS

Revitalize Building Mechanical Systems (4619)

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

RS Chimney Fan for Solid Fuel Applications

Guardrail and Barrier Systems

FIRE SUPPRESSION SPRINKLER SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

RS Chimney Fan for Solid Fuel Applications

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

SECTION COMMERCIAL-KITCHEN HOODS

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

A. Section Masonry Assemblies: Anchor placement in masonry.

Model DDX Deluge Valve

Transcription:

apcdayliter Fire and Explosion Roof Vents and Skylights 2007 07 72 36/CON BuyLine 4795 Smoke is the most deadly part of a fire.

APC Vents are the safest way to protect the building s occupants and firefighters. The National Building Codes demand fire vents for most industrial buildings. Sprinklers alone can t always save lives and property. Fire officials know that smoke is the deadliest part of a fire. That s why Section 910 of the International Fire Code mandates the use of automatic smoke control systems in high-piled storage facilities and in most one-story buildings greater than 50,000 square feet. Sprinklers clearly reduce fatalities and property loss, but their reliability can be questioned. The U.S. Consumer Product Safety Commission (CPSC) statistics suggest that sprinkler systems may not work half the time, due to a variety of reasons. Smoke vents eliminate the need to cut holes in the roof. One of the first things Unventilated building Fire after 1 minute But when sprinklers are used in combination with rooftop vents, fire safety in industrial buildings can be dramatically improved. firefighters do when Unventilated building Fire after 2 minutes they arrive at a fire is cut holes in the roof. APC smoke vents automatically open to vent Rooftop vents improve fire fighting. Fire vents also reduce lateral fire spread by toxic smoke and gases, Unventilated building Fire after 3 minutes preventing mushrooming reduce flashback and heat from igniting other In one-story buildings lower the building s internal fire and smoke spreads materials. APC vents improve temperature. Firemen can get into buildings faster to attack the firebase directly. laterally and rapidly. In minutes smoke and toxic gases fill the entire structure. visibility, saving precious time locating the fire seat and preventing collateral water damage.

Six reasons why reliable, economical APC Fire Vents are the best choice At 180ºF, the Dome begins to melt. From the onset of a fire, heat, smoke and gas rise to the roof structure, increasing the internal temperature. At 180 F, the specially formulated APC Quadri-Dome begins to soften. 1 2 3 APC Dayliter vents work every time thanks to the laws of science. APC Dropout vents rely on gravity and the special heat-sensing property of its dome material. When thermally activated by the rapid heat rise from fire, dome material softens and releases from its retaining frame venting smoke and gas. Works With All Sprinkler Systems Our AFL vent works with any sprinkler system, including ESFR sprinklers. Set to temperatures above sprinkler activation, the AFL will not release until the desired temperature is achieved. Strong Yet Lightweight A typical 4' x 8' APC unit weighs 110 lbs, yet dome material is one of the industry s strongest. APC Quadridome resists hail, industrial debris and errant birds. 4 5 6 Meets All Codes Section 910.2 of the IBC demands that one-story undivided buildings over 50,000 sq. ft. have smoke vents on the roof. FM- and ULapproved APC vents meet IBC and all national codes. No Moving Parts to Fail APC s drop-out design prevents possible lid closures and is unaffected by snow loads. APC vents have no moving parts to corrode, and they do not require inspection or maintenance. Half the Cost of Mechanical Systems and Exhaust Fans APC vents are not only reliable but are extremely cost effective. Easy to install, even in large units, APC vents can offer building owners substantial savings over mechanical vents. APC is the clear choice in smoke and heat vents. NORMAL CONDITION The facts don t lie! Judge for yourself. Mechanical Vents Meets international Building Codes Operation Vent, Heat, Smoke & Gas Works with Sprinklers Moving Parts That Can Fail Standard Fall Protection Pop-Up Fusible Link No DURING A FIRE APC Drop-Out Vents Meets international Building Codes Operation Vent, Heat, Smoke & Gas Works with Sprinklers Moving Parts That Can Fail Standard Fall Protection At 220ºF, the Dome releases allowing flames and smoke to vent. Once the interior temperature under the APC Fire Vent reaches 220 F, the Quadri-Dome releases from its framework dropping to the floor, creating a clear opening to exhaust smoke and heat. Below is a comparison of APC Dayliter and mechanical vents. Drop Out Fusible Dome No Unit Weight (4 x 8 ) 500-700 lbs. Unit Weight (4 x 8 ) 110 lbs.

apc dayliter FM Approved Fire Vents The rapid heat rise from fire causes the AFM s heat sensitive Quadri-Dome glazing to shrink and drop out of the vent opening, automatically creating an unobstructed vent for heat, smoke, and gas. The AFM Dome will reach full open position within five minutes after initial exposure to 500º F. apc dayliter ESFR Approved Fire Vents The AFL features a hinged retaining screen located under the heat-sensitive Quadri-Dome fitted with a fusible link (rated at a temperature of 200º higher than the sprinkler activation). The retaining screen resists the release of the Quadri-Dome until the specified fusible link temperature is achieved. Once temperature is achieved the dome drops out. Meets FM test standard 4430 for smoke and heat vents. APC s Quadri-Dome provides interior with 45% diffused light AFM Quadri-Dome has been tested to withstand 40 lb/ft 2 snow loading AFL is listed as the only approved drop out smoke vent for use with ESFR sprinklers in FM s Loss Prevention Data Sheet 2-2. Units available with 360º F or higher FM-rated fusible link Meets FM standard #4430 Safety cage designed to withstand 250 lb. impact load Four curb styles, including FM-approved curb mounted units for use with any existing curb Standard sizes from 48" x 48" to 72" x 154" Works with all sprinkler systems Single or double domes available in 3 curb styles Standard sizes from 48" x 48" to 72" x 154" MODEL AFM Aluminum retainer frame.078 thick aluminum curb frame.050 aluminum outer wall Dayliter Quadri-Domes white over clear Safety cage.032 thick aluminum inner wall 12" inside curb Model AFM-2D shown 48" X 60" 48" X 72" 48" X 84" 48" X 90" 60" X 101" 72" X 101" 60" X 154" 72" X 154" MODEL AFL.063 aluminum retainer frame.078 curb frame Wood nailer attached at factory Safety structure Dayliter Quadri-Dome Retaining screen Fusible link 12" Model AFL shown 48" X 60" 48" X 72" 48" X 84" 48" X 90" 60" X 101" 72" X 101" 60" X 154" 72" X 154" AFM AFM-2 AFM-D AFM-2D AFM-MB AFM-MB-2 AFM-MB-D AFM-MB-2D JSFV Curb Mounted Curb Mounted JSFV-D Curb Mounted Curb Mounted Add QR for Quick Release Rods or SN for Single Nailer. See page 9 for option information. *Inside curb dimension. Complies with all National Fire Codes including: ICBO 15-7; BOCA; SBCCI; IBC and IFC Section 910. AFL AFL-2 AFL-D AFL-2D AFL-MB AFL-MB-2 AFL-MB-D AFL-MB-2D QR - Quick Release Rods Please specify fusible link temperature. See page 9 for option information. *Inside curb dimension. Complies with all National Fire Codes including: ICBO 15-7; BOCA; SBCCI; IBC and IFC Section 910. 6 7

apc dayliter UL Approved Fire Vents APC s UL Approved AUL vent can be used in any facility where UL Labeled smoke vents and/or manual release operation is required (meets UL Standard 793). The AUL can be used in sprinklered and non-sprinklered buildings. The AUL features quick release rods and a firebrand screen that limits escape of burning embers. apc dayliter APC Fire Vent Product Options APC Dayliter offers a variety of illumination, insulation, and installation options to meet specific project requirements. DOME STYLES U L CLASSIFIED Only UL-listed drop-out gravity vent available. Meets UL standard 793 for Automatically Operated Smoke and Heat Vents. Quick release rods, standard for manual release. Firebrand screen limits escape of burning embers during fire. Double dome unit (full dome insulating overlay) required by UL. Single Dome Economical units available with white or clear domes. White dome offers 50% light transmission/diffusion. Clear dome offers 0% diffusion. White or Clear Available Double Dome Double dome construction creates a condensation barrier and offers higher insulation values than single domes. Double dome has an R value of 0.9. White or Clear Available MODEL Firebrand screen AUL.063 aluminum retainer frame.078 aluminum curb frame Wood nailer attached at factory AUL AUL-2 Dayliter Quadri-Dome Gasket Manual release rods Tube safety structure 400ft. lb. impact load AUL-MB AUL-MB2 12" Aluminum Curb Model AUL shown 48" X 60" 48" X 72" 48" X 84" 48" X 90" 60" X 101" 72" X 101" 60" X 154" 72" X 154" CURB STYLES Single Wall APC s economical prefabricated curb consists of a wood nailer and banded insulation. It allows for easy fastening of roof flashing. Curb for metal roofs available. Call (800) 222-0201 for details. Curb Mounted Units All APC Dayliter Fire Vents, Explosion Vents and Sky-Vue Skylights can be designed to mount on curbs by others. An FM approved curb mounted fire vent is available. To ensure that the units fit, please contact the APC factory for dimensions. SAFETY CAGES Curb Mounted Units APC Safety Cages are available for fire vents, skylights or explosion vents, including other manufacturers. APC offers standard cages as well as OSHA compliant safety cages with 4" x 4" spacing. Double Wall Insulated Double wall aluminum curbs are welded at corners and come with Class A insulation for increased insulating values. Curb for metal roofs available. Call (800) 222-0201 for details. Add QR for Quick Release Rods or SN for Single Nailer. See page 9 for option information. *Inside curb dimension. Complies with all National Fire Codes including: ICBO 15-7; BOCA; SBCCI; IBC and IFC Section 910. 8 9

apc dayliter Sky-Vue Skylights APC s Sky-Vue Skylights are economically priced and available for quick turnaround in standard 4' x 4' and 4' x 8' sizes (custom sizes available). Sky-Vue Skylights lightweight, modular construction features double-wall insulated curbs. Single and double dome options in white or clear acrylic available. Curb-mounted models and optional safety fall guards available. MODEL JDP.063 aluminum retainer frame.078 aluminum curb frame.050 aluminum outer wall with continuous corners Economically priced standard sizes for quick turnaround. Lightweight, modular construction features double wall insulated curb. White and clear acrylic domes available (specify single and double dome option). JSP JDP Optional safety cage fall guards (see page 9). Sky-Vue acrylic domes Dome Gaskets.030 aluminum inner wall JSP-MB JDP-MB JSC Curb Mounted Curb Mounted Curb Mounted Curb Mounted JDC Curb Mounted Curb Mounted Curb Mounted Curb Mounted 12" 1" 4 1/2" Model JDP shown Other sizes available apc dayliter APC Specifications I. General 1.01 Summary A. Furnish all fire vents/explosion & pressure relief vents/skylights, frames, curbs and attachments necessary to complete the work as indicated on the drawings and specified herein. 1.02 Related Sections A. The following sections contain requirements that relate to this section: 1. Division 6 Section Rough Carpentry for wood curbs and nailers. 2. Division 7 Section Roof Accessories for curbs, roof hatches and smoke vents. 3. Division 7 Section Flashing and Sheet Metal for metal flashing for fire vents/explosion & pressure relief vents/skylights. B. Refer to roofing system sections for roofing accessories to be built into this roofing system to accommodate work of this section. 1.03 References A. American Society for Testing and Materials (ASTM) B. The Aluminum Association (AA) C. American Architectural Manufacturers Association (AAMA) D. National Fire Protection Association (NFPA) E. Factory Mutual (FM) F. Underwriters Laboratory (UL) 1.04 Submittals A. General: Submit the following according to the Conditions of Contract and Division 1 Specification Sections. B. Product data for each type of fire vent/explosion & pressure relief vent/skylight specified, including details of construction relative to materials, dimensions of individual components, profiles, finishes, and light transmission values. C. Shop drawings showing fabrication and installation of fire vents/explosion & pressure relief vents/skylights, including plans, elevations, sections, and details of components. 1.05 Quality Assurance A. Materials and work shall conform to the latest edition of reference specifications specified herein and to all applicable codes and requirements of local authorities having jurisdiction. B. Fire Vents: 1. Units shall meet requirements of FM test standard 4430 for heat and smoke vents. 2. Units shall meet UL Test Standard 793 for Automatically Operated Roof Vents for Smoke and Heat. 3. Be in accordance with AAMA requirements for Smoke and Heat Vents. 4. Meet NFPA 204M Standard for Smoke and Heat Venting. C. Explosion Relief Vents 1. Use FM approved release devices. 2. Meet NFPA 68 Design Guidelines for Deflagration Vents and Vent Closures. D. Skylights 1. In accordance with AAMA Voluntary Specification for Skylights/Roof Windows. E. Single Source Responsibility: Obtain fire vents/explosion & pressure relief vents/skylights from one source of a single manufacturer. 1.06 Delivery and Storage A. All fire vents/explosion & pressure relief vents/ skylights, frames, and curbs shall be factory assembled in units and shipped to the job site. B. Deliver to site in original, unopened containers and/or pallets bearing manufacturer s name and label. 1.07 Warranty A. Manufacturer shall warrant that the units provided will be free of defects in materials and workmanship for a period of five (5) years from date of substantial completion. II. Products 2.01 Manufacturers A. APC Dayliter products specified herein and indicated on drawings shall be manufactured by Construction Specialties, Inc., 49 Meeker Ave., Cranford, NJ 908-272-5200, or other manufacturers with prior written approval. 2.02 Materials A. Frames shall be constructed of ASTM B 221 alloy 6063-T5 aluminum, mitered with sufficient seepage ports. Mill finished. B. Fasteners to be corrosion resistant. C. Domes shall be single dome or double dome, as required. D. Dome color shall be white or clear, as required. E. Curbs shall be constructed with a prefabricated aluminum curb, 3003-H14 alloy sheet. Curbs to be 12" high with mounting flange and shall include manufacturer s standard insulation and wood nailer or double wall aluminum with insulation. Mill finished. 2.03 (Please Specify Type) 1. Model AFM: Factory Mutual Approved Fire Vent. Provide APC Dayliter AFM-2D (as shown on page 6) drop out gravity fire vents. Vent shall comply with current Factory Mutual standard for automatic fire vents and shall carry the authorized FM label. Domes shall be of patented Quadri-Dome design. Domes to be white over clear with light transmission to be 45 percent diffusing. Integral curb to be double wall with Class A insulation. Safety structure shall withstand impact loading in excess of 250 ft.lb. Installation, cant, flashing, and roofing materials are not included. 2. Model AFL: Factory Mutual Approved Fusible Link Fire Vent. Provide APC Dayliter AFL (as shown on page 7) drop out gravity fire vents. Vents shall comply with current Factory Mutual standard for automatic fire vents and be listed in FM Property Loss Prevention Data Sheet 2-2 for approval with ESFR sprinklers. Vents shall carry the authorized FM label. Vent to operate with the use of a 360ºF, or higher, rated fusible link. Dome shall be of patented Quadri-Dome design. Dome to be white; light transmission to be 50 percent diffusing. Integral curb to consist of wood nailer and banded insulation. Safety structure shall withstand impact loading in excess of 250 ft.lb. Installation, cant, flashing, and roofing materials are not included. 3. Model AUL: Underwriter Laboratories Listed Fire Vent. Provide APC Dayliter AUL (as shown on page 8) drop out gravity fire vents. Vent shall comply with current Underwriter Laboratory standard for automatic fire vents and shall carry the authorized UL label. Dome shall be of patented Quadri-Dome design. Domes to be white over white; light transmission to be 25 percent diffusing. Wood nailer and rigid insulation shall be secured to curb. Manually-operable quick release rods shall permit removal of domes and frames from curb. Safety structure shall withstand impact loading in excess of 400 ft.lb. Firebrand screen included limiting escape of burning embers during a fire. Installation, cant, flashing, and roofing materials are not included. 4. Model JSFV: Curb Mounted Fire Vents. Provide APC Dayliter FM approved JSFV drop out gravity fire vents. Vent shall comply with current national fire test standards for automatic fire vents. Dome shall be of patented Quadri-Dome design. Safety structure shall withstand impact loading in excess of 250 ft.lb.. Curbs by others. 5. Sky-Vue Domed Skylights. Provide APC Sky- Vue Skylights. Skylights to be single or double dome construction. Domes to be white or clear acrylic. Integral curb to be double wall with insulation. Sky-Vue Skylights are also available without curb for curb mounting. Optional safety structure withstands impact loading in excess of 250 ft.lb. III. Installation 3.01 Installation A. Preparatory work: Standard trade practices are recommended for preparation of structural arrangements for installation of APC vent or skylights. B. Method: Individual APC units are furnished completely assembled, ready for installation on the roof deck and for flashing into the roof system. Tandem arrays are delivered in accordance with drawings and instructions provided. Note: the products shown in this catalog may be covered by one or more of the following patents: 6,161,348 See page 9 for option information. *Inside curb dimension. 10 11

7 Smoke & Heat 13 Explosion Fire Supression Tornado Flood accessing apc technical data photos and specifications has never been easier. just visit:www.apcdayliter.com. APC Product Information Is Also Available In: C/S Specialty Venting Tech Manual Explovent THE C/S GROUP OF COMPANIES: CONSTRUCTION SPECIALTIES, INC. C/S CONSTRUCTION SPECIALTIES COMPANY MANUFACTURING/SALES LOCATIONS U.S.A. Construction Specialties, Inc., Cranford, NJ /Tel:(800)222-0201/Fax:(800)293-4509/info@c-sgroup.com Canada C/S Construction Specialties Company, Mississauga, ON. /Tel:(905)274-3611/Fax:(905)274-6241/canada@c-sgroup.com For assistance with overseas requirements, fax C/S International (908)236-2903. Copyright 2006 Construction Specialties, Inc. Construction Specialties reserves the right to make design changes or to withdraw any design without notice. Printed in U.S.A. Series 07 (800) 222-0201 www.apcdayliter.com