FIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED

Similar documents
Smoke Vents. Certified to CE EN Roof Access Systems

This document is a preview generated by EVS

NFPA-APSEI Fire & Security 2010

Schueco Fire and Smoke Protection Systems

Uniclass L7535: N3253 EPIC L13:Y42. CI/SfB (57) X (K5) Residential Smoke Ventilation

THE SMOKE AND ACCESS SPECIALISTS. Compliance without compromise

WINDOW AUTOMATION SOLUTIONS NATURAL AND SMOKE VENTILATION SYSTEMS

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

mcr PROLIGHT, mcr PROLIGHT PLUS

SMOKE AND HEAT EXHAUST VENTILATION SYSTEMS SAFETY DUE TO APPROVED SMOKE OUTLET DEVICES EN COMPLIANT AND ECONOMICAL

D+H EURO-SHEV: Smoke ventilation according to DIN EN

GV Standard X-Vent Operation and Maintenance Manual

PRODUCT DESCRIPTION. Renovation smoke exhaust fumivent VdS

Smoke Control in Apartment Buildings. Smoke Control

Uniclass L7535 EPIC L13. CI/SfB (57) X. secontrols.com. Smoke Ventilation, Natural Ventilation and Window Automation

Mechanical smoke ventilation systems. CI/SfB 37.4 Xy

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

THE SMOKE MUST GO. Consulting - Project Planning - Supply - Installation - Service

Specifying the Right Rooflight. T: +44 (0) E:

Smoke / Natural Ventilation. simplicity & versatility. Smoke / Natural Ventilator Car Park Smoke Control Fire & Smoke Curtains Control Systems

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

Product Information October (8) Orivent 51 in Itella, Pennala. Orivent 01 in Oriville factory, Orimattila

General Principles of Smoke Control

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

YOUR GUIDE TO UNDERSTANDING CPR

Smoke control and access systems. CI/SfB 37.4 Xy

SMOKE CONTROL - NEW DIRECTIONS

FANERGY Far more than just a fan.

SHEVTEC Extended Travel Distance. System for Chettles Yard, Nottingham

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Performance Specifications LSF LIFT-SMOKE-FREE

FANERGY Far more than just a fan.

TUNNEL FANS STANDARD AND HOT SMOKE

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Protect human life against hazards at refineries and other sensitive. Complete cabin protected against blast, gas, fire and smoke

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

EN54 Part 23 Made Easy CPD PRESENTED BY SIMON ADAMS GENT BY HONEYWELL

Technical Information

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

Who are we? LGF SYSMAC a 15 Years Young and Vibrant Company Characterized by

Western Firex. Heat & Smoke Ventilator. EAGLE series Natural Ventilation

FIRE SAFE NOTICE BOARDS Education Buildings SPECIFYING FIRE RATED NOTICE BOARDS. Issue #1

Construction Products Regulation (CPR)

SELF PRESERVATION SOCIETY By Jim Creak

Colt International Ltd Commissioning and maintenance of smoke control systems CPD Technical Seminar

Technical Bulletin CE marking: from 1st July 2013

BUSINESS PLAN CEN/TC 72 FIRE DETECTION AND FIRE ALARM SYSTEMS EXECUTIVE SUMMARY

Actionpac 60/120 (LNS Standard)

UNIJET CAR PARK VENTILATION SYSTEM

BUSINESS PLAN CEN/TC 191 FIXED FIREFIGHTING SYSTEMS EXECUTIVE SUMMARY

ICC CODE CORNER 2012 IFC Code & Commentary

The Social Accountability International (SAI) Fire Safety Checklist

technical specification smoke venting systems

Emergency Extract Ventilation

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION REQUIREMENTS

Moffitt Firex. Heat & Smoke Ventilator. MoffittCorp.com (800) th Ave S. Suite 130 Jacksonville Beach, FL

Smoke Vent Control Panel PCB4 V4 Installation Manual

Some Important Aspects of Fire Safety Regulations about High Rise Buildings

Approved Document for New Zealand Building Code Warning Systems Clause F7 Third Edition

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

Fire Sprinklers The Ultimate Fire Fighters Eric Skare

Fire and Security Products and Services

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

Safety Manual Section 7 Fire/Life Safety

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Case Study 1 Underground Car Park

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS

Max Fire Box Users Guide

Prescriptive Requirement for Smoke Control

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

F.R.A.M.E. EVENT NETWORKS used in "FRAME".

Fire protection documentation. CFPA-E Guideline No 13:2015 F

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

PRESS RELEASE

- CONSTRUCTION FIRE SAFETY STANDARDS

PRODUCT SPECIFICATION FireMaster Plus

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

F.R.A.M.E. calculation report. This report is generated by the "FRAME for Windows program " The calculation is made for: Airport_building

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

Ceiling Microwave presence/absence detector 12-24V AC/DC

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

This document is a preview generated by EVS

Low Location Lighting

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar absolute) Press (bar g) (kg)


V3 Intelligent Damper Control and Monitoring System

EBMHS (standard & slim-line PSU)

Module 9: Ontario Building Code Fire Fighting Provisions

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Transcription:

COXDOME. FIRE JET SMOKE SYSTEMS FIREJET 165 24V / 48V SMOKE SYSTEMS CE EN12101-2 CERTIFIED DRIVEN BY DAYLIGHT WWW.JET-COX.CO.UK

IN THE CASE OF A FIRE WITHIN A BUILDING MORE THAN 90% OF FATALITIES ARE CAUSED BY SMOKE POISONING The greatest immediate danger to the occupants of a large building in the event of a fire comes from the smoke rather than the heat of the fire. Even a small fire can rapidly fill a large building with smoke to an extent where people escaping the building cannot see to find the escape routes and can be overcome by smoke inhalation. The recognised method of addressing these problems is to provide a smoke ventilation system with automatically operated roof ventilators. Smoke and Heat Exhaust Ventilation Systems (SHEVS) are therefore an essential component of any building s fire protection design concept. In a fire situation, smoke and heat exhaust ventilation systems create and maintain a smoke free layer above the floor by removing smoke. They also serve simultaneously to exhaust hot gases released by a fire in the developing stages. Their value in assisting in the evacuation of people from buildings and other constructions works, reducing fire damage and financial loss by preventing smoke damage, facilitating access for firefighting by improving visibility, reducing roof temperatures and retarding the lateral spread of fire is firmly established- so much so, it has become a legal requirement for all SHEV systems to be classified under CE EN12101-2. 02. COXDOME. FIRE JET SMOKE SYSTEMS

PRINCIPAL OF SMOKE VENTILATION (WITH SHEVS) In principle, high-level outlet vents and low-level inlet vents open automatically in the event of a fire to allow cool air into the building and allow smoke and hot air to flow out. This improves the conditions for occupants to escape and fire-fighters to enter. In the absence of ventilation, smoke fills the room, being drawn back down from the ceiling by convection as temperatures rise, leading to potential and particularly dangerous flashover. 1. SHEVS open immediately 2. Chimney effect aids evacuation 3. Safer and easier to fight WHAT IS EN12101-2 CERTIFICATION? EN Standards are written by CEN, the European standards organisation, on the basis of a mandate from the Commission. Standards detail the performance characteristics required of products to ensure they achieve minimum safety and operational standards. EN12101-2 relates to Natural Smoke & Heat Exhaust Ventilators and has become mandatory, replacing various national regulations, including BS7346 and DIN 18232. EN12101-2 covers the following parameters:- Characteristic Harmonised Standard Explained Reaction to Fire Upstand & Lid 7.5.2.1 Test to determine the Classification of the Upstand and Lid when exposed to fire Resistance to Heat B Class (B 300, 600 C) Annex G Test to check at what temperature the unit will remain operational Snow Load SL Class (SL 0, 125, 250, 500, 1000 N/m²) Annex D-E Maximum snow load class under which the unit will continue to open and stay open Wind Load WL Class (WL 0, 1500, 3000 N/m²) Annex F Maximum wind load class to ensure that when closed the unit can withstand the negative pressure of the class Low Ambient Temperature T Class (T -25, -15, -5, 0 C) Annex D-E Test to check at what minimum internal ambient temperature the unit will remain operational Reliability RE Class (Re 50, 1000) Annex C Test to determine how many times the unit can be opened (165 function) and remain reliable Co-efficient of Discharge Aa-Value Annex H Test to determine the areodynamic free area of the unit 03

Jet Cox FireJet 165 24V/48V Range provides a smoke and heat exhaust ventilation system for all Commercial and Residential applications. Supplied factory assembled and factory tested all products are certified to CE EN12101-2. FireJet rooflights not only help to provide smoke extraction in the event of a fire but they also provide day-to-day controllable ventilation. Available in a wide range of sizes (many of which are held in stock) the Jet Cox FireJet range complies with the latest Building Regulations on Fire Safety and can be integrated into any Building Management System. Linked to a central control panel, complete with a battery backup system in case of mains failure, the control panel can be triggered from either manual override switches local to the ventilator and the ground floor, by dedicated smoke detectors, or by interfacing with a third party smoke detection/fire alarm system. The FireJet Range is available with CLEAR or OBSCURE polycarbonate glazing to enhance the buildings natural daylight or with a fully insulated ALUMINIUM solid cover. Upstands can be specified either 300mm Splayed PVC-u or 300mm/400mm/500mm Splayed Metal. FEATURES FIREJET 165 24V/48V Sizes from 1000mm x 1500mm to 1500mm x 2500mm Opens to 165⁰ Galvanised Steel Mechanism Glazed Polycarbonate Cover or Solid Insulated Aluminium Cover One Mechanism regardless of size Optional Day-to-Day Ventilation Position without additional motor Extremely Low Noise Level Compact 24V/48V DC Motor Unit / Sealed IP54 Rooflight Size / Roof Opening Size (mm) 1000 x 1500 1200 x 1200 1200 x 1500 1200 x 1800 1200 x 2100 1200 x 2400 1200 x 2500 1250 x 1250 1250 x 1500 1500 x 1800 1500 x 2100 TECHNICAL SPECIFICATION CE EN12101-2 Certified 1500 x 2400 1500 x 2500 Certificate 1368-CPD-C-002/2009 (I.F.I Institute, Germany) Aerodynamic Free Area up to Aa2.74m² * Snow Load up to 2400N/m² Wind Load up to 1500N/m² Low Ambient Temperature T(-15⁰) Heat Exposure B300 Reaction to Fire Class E Opening Speed <60secs * Aa-Value in m² (aerodynamic effective smoke exhaust surface) according to DIN EN12102-2 Full technical data sheets are available detailing Geometric Areas, Aerodynamic Values, Snow Loads etc. For further information please contact our offices on 0121 530 4230 or at sales@jet-cox.co.uk WWW.JET-COX.CO.UK. 04

ACCESSORIES Wind Deflectors 24 v / 48v Control Panel with Battery Backup Emergency Push Button Open / Close operation for Ventilation Smoke Detectors Wind & Rain Sensors Safety Fall Grids Safety Anchor Points 48V SYSTEM Vs 24V SYSTEM The FireJet Range can also be specified as a 48V system. This option can provide many advantages to multi-unit applications. Improved Performance Less Voltage Drop between multiply units Increased power in the event of high Snow Loads Cost Reductions Each 48V Control Panel will operate double the number of SHEV units Reduction in Cable cross sectional size Significant reduction in Installation 05. COXDOME. FIRE JET SMOKE SYSTEMS

The Firejet 24V/48V CE EN12101-1 Smoke System is also fully compatible with the Jet Cox VarioNorm Barrel Vault Range. For further details, please contact our offices on 0121 530 4230 or sales@jet-cox.co.uk JET COX LTD CRH House Units 1-3 Prothero Ind Est Bilport Lane Wednesbury West Midlands WS10 0NT Tel: 0121 530 4230 Fax: 0121 530 4231 Email: sales@jet-cox.co.uk www.jet-cox.co.uk Printed April 2015 v1