Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

Similar documents
AIRFLOW SPECIFICATIONS

ALARM FOR SAFETY CABINETS SPECIFICATIONS

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Installation & Calibration Guide

AFA 500 FUME HOOD ALARMS

Model 405 AIRGARD Fume Hood Monitor

FUME HOOD MONITOR ALNOR AIRGARD 335

Fume Hood Operating Display Panel

AirGard. Air Flow Monitors

AirGard 385 Fume Hood Monitor

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

CommStat 4 Controller

FUME HOOD MONITOR ALNOR AIRGARD 200

LABCONCO 1000 GUARDIAN DIGITAL MONITOR Operating and Instruction Manual

S E R M A N U A L. Alarm. Module. Rooster Monitor100

RPM1600 Series Room Pressure Monitors

DMFPM-2R MULTIFUNCTIONAL

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

RS Pro Infrared Temperature Sensor

Premier Hazard STC Instructions

CRITICAL ENVIRONMENT MONITOR ALNOR AIRGARD 350 CEM

Static Pressure Alarm For Hazardous Location Fume Hoods

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Pump-Up Controller MODEL 4062

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Pump-Down Controller MODEL 4052

Door Release Power Supply

HVAC Controls Laboratory. Model EVERWATCH Face Velocity Monitor. Operation and Service Manual. P/N , Revision E October 2002

Critical Environments. Model FHC50/FHM10. Fume Hood Controller/Monitor. Operation and Service Manual. P/N , Revision B October 2010

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

G34 AU1B (External Ultrasonic Sensor) Version 3

METEOROLOGICAL INSTRUMENTS

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

RC-2000 Thermostat Installation Instructions

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

WIRING DIAGRAM AND INSTRUCTIONS

METEOROLOGICAL INSTRUMENTS

Software Version 2.01 LEVEL MONITOR MODEL 220

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

Mark 25 Ultrapure Water Conductivity Analyzer

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

LeakSafe. solutions. WaterSwitch2. Installation Instructions

SC Installation, Operation & Application Guide

AFA1000/1 MK3 Airflow Monitor

Analog Room Pressure Monitor RPC Series

Pioneer-R16 Gas Monitor Operator s Manual

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

FIL-SPL Flow-through heater for central heating USER MANUAL

METEOROLOGICAL INSTRUMENTS

Beacon 800 Gas Monitor Operator s Manual

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Operator s Manual. IP-100 Immersion Probe Cooler

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

WARNING Important Safety Information

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

EVERWATCH FACE VELOCITY MONITOR MODEL 8610

WARNING Important Safety Information

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

SC Installation, Operation & Application Guide

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

Installer Guide. WARNING Important Safety Information. 1 Specifications

MODEL MARINE WIND TRACKER

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

WARNING Important Safety Information

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Owner s Manual RD432-0 Chemical Controller

1 4 DIN Dissolved Oxygen Controller

PORTABLE AIR CONDITIONER

LeakSafe. solutions. WaterSwitch2. Installation Instructions

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

Instructions Manual SHC520X - SHC700X

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

RANGE HOOD INSTALLATION MANUAL

Auto Dialer. Manual E-921APQ E-921GPQ

Computer Room Guard Model VM Manual and Installation Instructions

Alarm Tone Generator Model AG17

Model OEM-2 INSTRUCTIONS FOR USE

Intelligent Electronic Enclosure Thermal Management Systems

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

FCCP 200: Fume-cupboard indicator and monitor

Electro-Sentry. Users Manual

GAS-Mate. Combustible Gas Leak Detector

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

Transcription:

TYPE C STANDARD & NIGHT SETBACK S Specifications and Owner s Manual PLASTEC VENTILATION, INC.

TYPE C STANDARD & NIGHT SETBACK General Description BENEFITS Safety: air flow is maintained at required speed at all sash heights Energy savings: only the lowest required amount of air is exhausted therefore reducing energy bill User comfort: Low air speeds ensure comfortable noise level Ease of installation and maintenance Stable and accurate analogical sensor reading Attractive design: available in choice of LED or digital display RANGE Versions: C LED: Monitors and controls air speed, LED lights C DIGITAL: Monitors and controls air speed, digital read out in meter per second or feet per minute FEATURES Audio and visual alarm 0 to 10V or 4-20mA VAV system to link to inverter 3 Pushbuttons: Fan On/Off, Light On/Off, Mute Automatic pre-purge with inverter 30s purge following fan switch off Alarm disabled when fan switch off Sash High indicator Auxiliary contact for fan make up, etc. OPTIONS Surface Box Mounting: Plastic enclosure to mount the face plate and to avoid profile cutting the service panel. Alarm Relay: A remote alarm can be triggered from a relay on the controller pcb. Battery Back Up: Red LED alarm is still functional up to 12 hours when unit loses power. Custom Resin Stickers: Customizable resin stickers with logo, address, etc. COLORS Plastic fascia is available in: - White (Standard) INTERNATIONAL STANDARDS COMPLIANCE In accordance with: - European laboratory standard EN 14175-2 - Electromagnetic standards EN 61326 : 1997/A1 : 1998/A2 : 2001/A3 : 2003 (Test report RC-05-42060-1) US FCC Part 15 Class B edition 2005 (Test report RC-05-42060-2-A) - European RoHS directive governing disposal and recycling of electronics - French laboratory standard XPX 15203 of Sept. 1996 - CE COMPONENTS Circuit Board: Panel mounted circuit board to be installed vertically or horizontally onto fume cupboard with 2x Ø 2.8 mm / 0.11" screws. IP55 protection ensured by O ring seal. Face plate to be supplied with chemical resistant plastic sticker (horizontal or vertical) with control/push buttons on fascia. Surface box mounting optional. Numerical and Antistatic Sensor: To be installed inside fume hood. Sensor measures air speed variations inside fume hood. Supplied with a 3.5 m / 11.48' (5 m optional) shielded cable with pin connections onto controller circuit board. Power Supply: 115 VAC to 12 VDC power transformer directly into controller circuit board. Comes with a wall plug and cord. Adaptor may be required to fit local power socket. PACKING Supplied in cardboard box which includes controller circuit board, face plate, sensor and power transformer. Surface box mounting optional. 2

TYPE C STANDARD & NIGHT SETBACK Operating Principle When the fume extraction fan is running, it causes negative pressure inside the fume cupboard. If the sash is lowered, the negative pressure become more intense causing air to be drawn through the sash opening at an increased velocity. Conversely, if the sash is raised the negative pressure becomes less intense and air velocity reduces. If an opening is made in the wall of the fume cupboard, air will enter it at a velocity determined by the same negative pressure that is drawing air into the sash opening. By sensing the air velocity through an opening, we can determine its level at the sash opening. PLASTEC AirControl Type C exploits this by the placing of a numerical sensor, or thermal anemometer into a hole in the cupboard and sending the air velocity measurement obtained to a display on the fascia panel. Based on air velocity measured, Plastec AirControl C will send a signal to an inverter to either increase or decrease fan speed. The air velocity level is displayed on the fascia either by LED illumination or digital read-out. An audible alarm will also sound if the air velocity is too low. SENSOR Airflow Monitor www.plastecvent.net 3

TYPE C STANDARD Schematic AirControl C LED & Digital Inverter System 115 VAC /12 VDC Power Supply Controller Sensor Sensor Signal Input Hood Light on/off relay Air Make-up on/off relay Motorized Damper Sash High Alarm Input 0 to 10V or 4-20mA OR Fan on/off relay Make-up Fan Frequency Inverter OUTPUT: 0 to 10V or 4-20mA 230V 3Ph Sash movement = Pressure decrease or increase Air speed monitoring & control! If air speed is low Frequency Inverter 230V 1Ph input Plastec Extraction Fan: Speed increase or decrease 4

TYPE C NIGHT SETBACK Schematic AirControl C Night Setback 115 VAC /12 VDC Power Supply Controller Sensor Hood Light on/off contact Sensor Signal Input Sash High Alarm Input Night Setback relay OUTPUT Sash movement = Pressure decrease or increase Air speed monitoring & control! If airflow is low 5

TYPE C STANDARD Specifications AirControl C LED AirControl C Digital Part Number 819703 819704 1 green LED for normal air speed 1 green LED for normal air speed Display Visual 1 red LED flashing for alarm "HI" for high air speed displayed No digital display 1 red LED flashing for alarm 3 digit display with velocity reading Units N/A meter per second (m/s) / FPM Display Range N/A 0-2.00 m/s / 0-400 FPM Alarm Setpoint Standard: below 0.39m/s / 78 FPM Standard: below 0.39m/s / 78 FPM Alarm Delay Selectable: 15s or 30s Selectable: 15s or 30s Analog Output 0-10V or 4-20mA 0-10V or 4-20mA Alarm Indication 1 red LED flashing & audible buzzer 1 red LED flashing & audible buzzer Alarm Mute Light On/Off Fan On/Off Alarm Relay Yes, optional Yes, optional Battery Back Up Yes, optional Yes, optional Sash High Input Audible and orange flashing LED indicate Audible and orange flashing LED indicate sash position switch has been tripped sash position switch has been tripped Mounting Flush or surface box (option) Flush or surface box (option) Factory pre-calibrated @ 0.5m/s / 100 FPM Factory pre-calibrated @ 0.5m/s / 100 FPM Calibration Recalibration possible Recalibration possible Power Requirement 12VDC (power supply included) 12VDC (power supply included) Orientation Vertical /Horizontal Vertical Monitor Dimensions (metric) Monitor Dimensions (U.S.) Front fascia: 210L x 90W x 10D mm Front fascia: 210L x 90W x 10D mm Surface box: 205L x 85W x 14D mm Surface box: 205L x 85W x 14D mm Front fascia: 8.27"L x 3.54"W x 0.39"D Front fascia: 8.27"L x 3.54"W x 0.39"D Surface box: 8.07"L x 3.35"W x 0.55"D Surface box: 8.07"L x 3.35"W x 0.55"D 56

TYPE C NIGHT SETBACK Specifications AirControl C LED AirControl C Digital Part Number 819703 819704 1 green LED for normal air speed 1 green LED for normal air speed Display Visual 1 red LED flashing for alarm 1 red LED flashing for alarm No digital display 3 digit display with velocity reading Units N/A meter per second (m/s) / FPM Display Range N/A 0-2.00 m/s / 0-400 FPM Alarm Setpoint Standard: below 0.39m/s / 78 FPM Standard: below 0.39m/s / 78 FPM Alarm Delay Selectable: 15s or 30s Selectable: 15s or 30s Analog Output 0-10V 0-10V Alarm Indication 1 red LED flashing & audible buzzer 1 red LED flashing & audible buzzer Alarm Mute Light On/Off Night Setback On/Off Alarm Relay Yes, optional Yes, optional Battery Back Up Yes, optional Yes, optional Sash High Input Audible and orange flashing LED indicate Audible and orange flashing LED indicate sash position switch has been tripped sash position switch has been tripped Mounting Flush or surface box (option) Flush or surface box (option) Factory pre-calibrated @ 0.5m/s / 100 FPM Factory pre-calibrated @ 0.5m/s / 100 FPM Calibration Recalibration possible Recalibration possible Power Requirement 12 VDC (power supply included) 12 VDC (power supply included) Orientation Vertical /Horizontal Vertical Monitor Dimensions (metric) Monitor Dimensions (U.S.) Front fascia: 210L x 90W x 10D mm Front fascia: 210L x 90W x 10D mm Surface box: 205L x 85W x 14D mm Surface box: 205L x 85W x 14D mm Front fascia: 8.27"L x 3.54"W x 0.39"D Front fascia: 8.27"L x 3.54"W x 0.39"D Surface box: 8.07"L x 3.35"W x 0.55"D Surface box: 8.07"L x 3.35"W x 0.55"D 57

TYPE C STANDARD & NIGHT SETBACK Specifications MONITOR & MOUNTING BOX 35 mm / 1.38" 90 mm / 3.54" Mounting Box Face Plate 210 mm / 8.27" Ø 2.8 mm / 0.11" 24 mm / 0.94" PANEL CUTOUT DIMENSION SENSOR 65 mm / 2.56" 17 mm / 0.67" 28 mm / 1.10" Cable L = 3.5m / 137.76 (11.48') 40 mm / 1.57" 7.5 mm / 0.30" NOTE: All dimensions in mm / inches Ø 22 mm / 0.87" 8

TYPE C STANDARD Overall View Front plate/fascia Customizable Resin Sticker Chemical and pressure resistant sticker Digital display. Not applicable on LED version HI displayed: Airflow too high One green LED lit up: Airflow OK Flashing red LED for alarm: air speed too low Sash high LED. Starts flashing when sash position switch has been tripped LED fan on/off indicator If fan on, LED orange Fan on/off push button Alarm Mute push button LED light on/off indicator If light on, LED orange Light on/off push button Calibration LED. Should be off when calibration is completed 79

TYPE C NIGHT SETBACK Overall View Front plate/fascia Customizable Resin Sticker Chemical and pressure resistant sticker Digital display in m/s or fpm HI displayed: Airflow too high One green LED lit up: Airflow OK Flashing red LED for alarm: air speed too low Sash high LED. Starts flashing when sash position switch has been tripped Night Setback on/off indicator. If LED lit up, night setback is on. Alarm cannot sound Alarm Mute on/off push button LED light on/off indicator If light on, LED orange Light on/off push button Calibration LED. Should be off when calibration is completed 10

TYPE C STANDARD & NIGHT SETBACK Contacts & Features Contact Light On/Off Control 220v 3A Alarm Relay 220v 3A (optional) VENT1: Fume fan to inverter run relay VENT2: Make-up fan 220v 3A Power Supply: 115 VAC/12 VDC input Resistance to be cut for night setback use Reset Sensor Connection Sash High Contact 0-10V signal to link to inverter control Auxiliary contact or Night setback contact ON OFF Settings: 1. On: Alarm always active Off: Alarm disabled when fan is off 2. Alarm delay setting: On: 30 seconds Off: 15 seconds Battery back up Rechargeable (optional) 115

TYPE C STANDARD & NIGHT SETBACK INSTALLATION Installation, Calibration & Alarm Test 1) Drill a Ø 23mm / 0.91" hole either in the top or side of the fume cupboard to allow sensor positioning. Make sure sensor is not in a turbulent zone where the pressure can fluctuate but where it can monitor stable changes in pressure. Attention should be paid to dead zones near the top of the fume cupboard. 2) Proceed with wiring as seen on page Contacts & Features. 3) Position and secure monitor to service panel of the fume cupboard with the two self-tapping screws supplied. Do not forget to position O ring seal into the moulded groove in the back of the face plate. CONTROLLER SET UP PROCEDURE All monitors unless indicated otherwise are factory pre-calibrated at 0.5 m/s or 100 FPM. If you need a different sensor calibration and/or displayed speed reading: 1) Make sure that controller is properly linked to inverter and that the ventilation is working. You need an anemometer to do this set up. 2) Push for more than 5 seconds, then release and push simultaneously for Standard or for Night Setback within the following 5 seconds. Buzzer sounds twice, the green LED is on and the red LED is flashing indicating controller is in manual set up mode. 3) Raise the fume cupboard to its test height e.g. 500mm/19.69". 4) Push or to increase or to decrease the fan speed via the inverter until the anemometer is reading required air speed. Every button press increases or decreases the speed of 0.5V producing one beep. The maximum value is 10V, the minimum is 0.3V. For model without digital display (819703), please go directly to step 6. 5) For digital display model (819704), press Reset button at the back of the controller to change the required speed display from 0.3 m/s/59 FPM to 0.7 m/s/138 FPM, using and. The value will be memorized as the set point. 6) Wait for 15 seconds or so for air speed to stabilize. 7) To return to AUTO mode, push again until the buzzer beeps 3 times (about 3 seconds) and the green LED is illuminated: new calibration (above or equal at 0.2 m/s) is accepted. This is automatically done after 7 minutes in manual mode. The buzzer beeps 10 times in case of incorrect calibration. All updated information is stored in an internal memory which saves and holds the data even in case of power cut. 125

TYPE C STANDARD & NIGHT SETBACK Installation, Calibration & Alarm Test VELOCITY TYPE To change Digital readout from/to m/s to FPM: Press simultaneously the following buttons: until buzzer sounds (about 5 seconds). DISPLAY MESSAGES The display will show HI for an airflow superior to 1 m/s / 96 FPM and LO for an airflow inferior to 0.20 m/s / 40 FPM. In case of faulty, improper or absent sensor, the display will show PB. FACTORY DATA RESET Press Reset (at the back of the controller) for 15 seconds. Buzzer sounds 5 times. When using this feature, you restore factory default settings: set point and display at 0.5 m/s / 100 FPM, 7V output to the inverter and all relays and LEDs deactivated. This operation should be imperatively done in Auto mode. TEST MODE Test mode is to confirm that all functions are operational. To access test mode, follow this procedure: 1) Press simultaneously following buttons: for 2 seconds for Standard or for 2 seconds for Night Setback * Buzzer sounds twice 2) Press the 3 buttons alternately. * Buzzer sounds 3 times indicating normal operating mode * Buzzer sounds 10 times if malfunction In case of faulty sensor, the display will show PB. 135

TYPE C STANDARD & NIGHT SETBACK Maintenance, Troubleshooting & Warranty MAINTENANCE Front plate and stickers of airflow monitor may be cleaned with mild soap and water on a damp cloth to remove finger marks, oils and residue. Do not use abrasives. Do not allow liquids to enter the plastic casing. Dry the monitor thoroughly after cleaning. TROUBLESHOOTING PROBLEM No indicators CHECK Power supply may not be plugged into AC supply. Improper alarm setpoint Airflow sensor is factory precalibrated at 0.5 m/s or 100 FPM. Alarm setpoint may not be accurate if sensor is not properly located. Sensor needs to be recalibrated if setpoint is different than 0.5 m/s or 100 FPM. Follow Sensor Recalibration Procedure on page 6. Alarm is too sensitive, buzzer rings often for short periods of time Change alarm delay setting to 15s or 30s if already set to 0. See contact & features section. WARRANTY PLASTEC Ventilation, Inc. warrants its equipment, products and parts, to be free from defects in workmanship and material under normal use and service for one year after delivery to the first user. Product must be returned to point of purchase, with dated bill of sale, within one year of purchase. If factory return is required, please contact distributor first. 145