Important Safeguards (For your safety, please follow the instructions below.) Specification. High Speed Hand Dryer. Warning

Similar documents
Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

TECHNICAL, ENVIRONMENTAL AND MECHANICAL SPECIFICATIONS

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Electric Wall/Ceiling Projection Screen

Manifold Installation Controller MIC-180. Installation and Operation Instructions

INSTALLATION AND OPERATION INSTRUCTIONS FOR

IMPORTANT SAFETY INFORMATION:

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

Installation Instructions

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

High Power Range Hood

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

AMBIANCE LINEAR 40 AMBIANCE LINEAR 60 AMBIANCE LINEAR 100 SAFETY INFORMATION AND OPERATIONS MANUAL

Installation Instructions

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

Installation Instructions

I storm. Circular High Speed Hand Dryer. Model N2 : I storm...,. Patent Pending. Operating Instructions and Parts Manual

Installation Instructions

50 FLAT PANEL BUILD IN ELECTRIC FIREPLACE

GE Monogram. Installation. Instructions. Professional Gas Cooktops 48" Natural Gas Models ZGU48N4GWSS ZGU48N6RWSS ZGU48N6DWSS

Installation Instructions

Installation Instructions

WALL MOUNTED ELECTRIC FIREPLACE HEATER. Model # : Onyx Ivory Mirror OWNER S MANUAL. AC V 60Hz 1500W

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

ELECTRIC FLAT PANEL FIREPLACE HEATER

CEILING FAN OWNER'S MANUAL

IMPORTANT SAFETY INFORMATION:

Installation Instructions

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

CEILING FAN OWNER'S MANUAL

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

Wall Mount Electric Fireplace

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

LIMITED LIFETIME WARRANTY

READ AND SAVE THESE INSTRUCTIONS

CEILING FAN OWNER S MANUAL

Model: AC-108. Instruction Manual

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

Electric OmnipanelII Towel Radiator

Installation/Instruction Manual

Innes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM

Installation Instructions 30 French Door Built-in Wall Ovens

CEILING FAN OWNER'S MANUAL

Installation. Leveling

CEILING FAN OWNER'S MANUAL

INSTALLATION INSTRUCTIONS

CEILING FAN OWNER'S MANUAL

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

Installation Electric Dryers Instructions 01

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Use, Care, and Installation Guide

Installation Instructions

FSA-Series Heavy-Duty Flat panel Emitter Architectural Electric Overhead Infrared Heaters

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

CEILING FAN OWNER S MANUAL

INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

Installation Instructions Dual Fuel Ranges

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

Installation Instructions. Instructions de montage. Instrucciones de instalación HC

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

Installation Instructions

Installation Instructions

Installation. Built-In Electric Cooktop. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Installation Instructions

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

OPERATING AND INSTALLATION MANUAL

Air Conditioner. user installation & manual manual. imagine the possibilities

INSTALLATION INSTRUCTIONS

CEILING FAN OWNER S MANUAL

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

CEILING FAN OWNER'S MANUAL

2 PREPARE THE OPENING

ANYWHERE. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

OPERATING AND INSTALLATION MANUAL

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

MILLA ELECTRIC FIREPLACE

INSTANT HOT WATER DISPENSER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

Installation Instructions

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

WAILEA OWNER S MANUAL

Installation Instructions

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR-DWSH01-S

OPERATING INSTRUCTIONS MANUAL FLE-150 INDUSTRIAL / COMMERCIAL ELECTRIC HEATER (OPERATOR MUST RETAIN FOR FUTURE REFERENCE)

Transcription:

INSTALLATION MANUAL Important Safeguards (For your safety, please follow the instructions below.) In this Instruction Manual, the following symbols are shown for safe and proper use of your automatic faucet and in order to alert you to the possibility of personal injury and damage to your property. The symbols and their meanings are as follows. arning Ignoring these symbols may cause personal injury and/or property damage. *Some models may have different components from the ones illustrated below. Do not Caution Do not disassemble Do not use in humid area Ignoring these symbols may cause severe injury and/or property damage. arning Do not install the unit in the places where corrosive or combustible gas can be present. This may cause product failure or damage. Never attempt to disassemble for repair or modification. This may cause electric shock, fire, injury or failure Do not install outdoors or where it is exposed to water. This may cause current leakage, electric shock, fire, or failure. Important Important Do not! Product Power Rating Power Connection Power Saving Function Decibel Rating Air Speed Dry Time Capacity Ambient temperature Specification HDR100#GY Clean Dry High Speed Hand Dryer 120V AC, 4.25 Amps, 60 Hz, 510 Hardwiring Automatically turns OFF after 60 seconds of use 62 db 224 mph (100 meters/second) 12 seconds 0.20 gal (700 ml) 32-104 F (0-40 C) Size 9-5/8" x 18-1/2" x 6-5/16" eight 10 lbs (4.5kg) arning It is recommended to install a circuit-breaker in the power supply Failure to do this may cause electric shock during overload or short circuit. Caution The chassis assembly must be installed on a smooth and even wall surface which has enough strength. Failure to do this may cause damage or personal injury if it falls down. Notice Do not place anything beneath the unit; leave a clearance of 3-15/16 (100mm). Do not install on uneven wall surface. If air flow is not good, the product may not perform well. 0GU3040 2008.04

* Before Installing 1. Precautions Confirm the rough-in, major dimensions and wiring diagram before installation in order to properly install the hand dryer and electrical wiring. All electrical wiring should be installed in accordance with national/local codes and regulations with an assistance from a certified electrician. Clearance for drain tray, shown in Set-up Drawing, is required for proper air flow into the unit and maintenance of the tray. Set-up Drawing Some models may have different components as illustrated below. 3 HOLE BRACKET DIA. 5/32 (4mm) 7-13/16 (199mm) 3-1/16 (77mm) DIA. MOUNTING HOLES (4) 5/32 (4mm) 6-11/16 (170mm) 6-5/16 (162mm) 9-5/8 Mounting surface should be even and smooth. Confirmation must be made that the wall has enough strength for hand dryer installation and be sure to use all the mounting harware provided to securely install the hand dryer. 9-7/16 (240mm) ELECTRICAL INLET 7/8 (22mm) DIA. HOLE (470mm) (470mm) It is necessary to install circuit breaker for the power supply. 2. Others Pay special attention so that both top cover and sensor surface are not flawed or scratched. Do not place other devices using inverter or infrared sensor near the hand dryer, this may cause malfunction. *Recommended mounting bracket heights from floor are as follow: -Male/Female: 53 (1346 mm) -Children: 47 (1194 mm) -Handicapped: 45 (1143 mm) Meets the American Disabilities Act Guidelines, ANSI A117.1 and CSA B651 requirements when mounted in a recessed wall where the front surface is not more than 4 (102mm) from finished wall and max. height of air blower outlet from finished floor is 47-1/4 (1200mm). (actual placement) (470mm) 10-3/8 (263mm) CLEARANCE FOR DRAIN TRAY AND AIR FLO PATH** 7-1/8 (180mm) 8-7/8 (224mm) 9-5/8 9.5/8 TOP COVER ASSY UNIT* DRAIN TRAY ASSY* DRAIN TRAY 6-5/16 (160mm) 6-5/16 (162mm) 7 (177mm) 4-5/16 (110mm) FINISHED ALL 5/8 (16mm) 7-13/16 (199mm) 9-7/16 (240mm) 3-15/16 (100mm) *Top Cover Assy Unit and Assy are two separate parts. **Clearance is required in order to take off the tray for cleaning and maintenance and have good air flow into the unit. Ø4.5X30 (mm) SCRE POER CABEL (HARDIRING) Ø4.5X30 (mm) SCRE Ø4.5X30 (mm) SCRE 5/8 (16mm) FLOOR

Installation *Some models may have different component as illustrated below. Hand Dryer Unit w/o Top Cover Sensor Platform for Mounting bracket Chassis Assy. <Bottom view> air nozzles Power switch (Connection type) ON POER OFF Filter all surface back of Drain Tray Assy. Assy Drain tray Filter case Filter case <View with cover removed> Accessories Model is subject to change without further notification. Mounting Bracket Screws and vandal resist Hex rench Template Owner s and Installation manual Installation position (φ4.5 30)X7

Installation Procedure STEP 1 1 Use template, mark the wall for locations and install the mounting bracket. Mounting Bracket STEP 1 Caution Mark the wall with template and install the bracket Chassis Assy. must be installed on a rigid and even surface Failure to do this may cause damage or personal injury when it falls. Chassis Assy. 2 Complete the electrical wiring; install the junction box,and connect the power cord using wire nuts. 3 Mount the Chassis and 4 Install the top cover and drain tray junction box location Attach the bracket firmly on the rigid wall with three screws (φ4.5 30) provided. In the case of a tile or concrete wall, please use plastic plug anchors with screws provided. Screw (x3) (φ4.5 30) 3 HOLE BRACKET DIA. 5/32 (4mm) Screw (x4) (φ4.5 30) 7-13/16 (199mm) 9-7/16 (240mm) (actual placement) 3-1/16 (77mm) DIA. MOUNTING HOLES (4) 5/32 (4mm) ELECTRICAL INLET 7/8 (22mm) DIA. HOLE 7-1/8 (180mm) 8-7/8 (224mm) 9-5/8 6-11/16 (170mm) (470mm) 35-3/4 (907mm) Floor surface 45-3/16 (1147mm) *Recommended mounting bracket heights from floor are as follow: -Male/Female: 53 (1346 mm) -Children: 47 (1194 mm) -Handicapped: 45 (1143 mm) 46-3/4 (1186mm) 53 (1346mm) * To be continued on the back

STEP 2 - STEP 4 STEP 2 Complete the electrical wiring STEP 3 Mount the Chassis and Use the special hex wrench provided to remove the 2 screws (φ4 10) from the top cover, then remove the cover. Put the connection point (with wire nuts) into the junction box. To remove the top cover, pull the lower part 1 towards you and pull Hang the Chassis onto the mounting bracket. the upper part 2 upward, then remove it. Insert the Assy. into the bottom of the Chassis, and attach Hang Chassis Assy. mounting platform onto mounting bracket hooks.. the lower part of the Assy. 1 to the Chassis Assy. 2 with 2 Connect the power cord inside the main body case with the power cord screws (Ф4.5 30) provided. out of the wall and use wire nuts (certified electrician to confirm the specific wire nut to use). Vandal resist Screw for (x2) mounting bracket Chassis Chassis mounting platform Chassis mounting bracket hooks mounting bracket (Actual Placement) STEP 4 Install the top cover and drain tray 1 Insert the hook of the top cover into the slot at the upper part of the Chassis, 2 then put the cover down. Then, fasten the cover with two screws (Ф4 10) that were previously taken out. * POER MUST BE IN OFF POSITION DURING INSTALLATION. Connection diagram hook of Slot at the upper part of the Chassis Assy. Chassis Connection point (Actual Placement) Screw for (x2) (φ4 10) Drain tray Connect the cord firmly with a wire nut or equivalent. hen installing the drain tray, slide it completely into its maximum depth. Drain Basin

Function Test 1. Checking after installation iring Diagram Test the product as follow after the installation is complete. First peel off the seal on the filter. (The seal is used to protect the filter from scratches during shipment; it is no longer needed.) Sensor Control Power Switch P6 P5 Bu P4 R P7 P2 Air nozzles Peel off the seal P1-1 Motor P1-2 P3 B 1. Check the main Power Supply Switch. Turn on the main power supply switch on. Power Connector B Power Fuse Power Switch B Motor 2. 3. Check the power switch of the hand dryer Turn the power swtich ON. Check the functionality Place your hand under the outlet nozzles to see if air blows out. G B=BLACK R=RED =HITE Bu=BLUE G=GREEN After trial run After you check the functionality by trial run, give the User Manual (with arranty) to the customer, and explain how to use and maintain the product.