30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

Similar documents
30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

30RBV/30RQV Inverter Air-Cooled Liquid chillers & Reversible Air to Water Heat Pumps PRODUCT SELECTION DATA INSTALLATION, OPERATION AND

30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

Do you want a versatile solution

AQUASNAP JUNIOR 30RHV

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Advance Split

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Water and ground source heat pumps 61WG kw. Heating

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

38RBS Air-Cooled Condensing Units. product selection data. commercial and industrial applications. compact design.

61AF High-Temperature Monobloc Air-to-Water Heat Pumps with Integrated Hydronic Module. Nominal heating capacity kw.

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Air to water Heat Pump System

30RH B Nominal cooling capacity kw Nominal heating capacity kw

30RB /30RQ

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

PRODUCT GUIDE

30RB /30RQ

INTEGRATED HEATING SYSTEMS CATALOGUE

Unit with optional hydronic module 61WG/30WG. Nominal cooling capacity kw Nominal heating capacity kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Air to water Heat Pump System

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

HT V2 HT Split

30RBS /30RQS Air-Cooled Liquid Chillers, Reversible Air-to-Water Heat Pumps. product selection data

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

Neosys Product catalogue

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

30RB A /30RQ

HYDRONIC RESIDENTIAL

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

30XAS Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features and advantages. Very economical operation

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

61WG/30WG/30WGA. Water-Cooled and Condenserless Liquid Chillers Water-Sourced Heat Pumps. product selection data. 30WG optimized for cooling

ELFOEnergy Duct Inverter

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

30XW-PZE/30XWHPZE-A WATER-COOLED SCREW CHILLERS WATER-SOURCED SCREW HEAT PUMPS PRODUCT SELECTION DATA

Galletti Water chillers and heat pumps catalogue

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: 18.8~35.5 kw 30RQ: Nominal cooling

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

PAC BT LOW TEMPERATURE HEAT PUMP

ELFOEnergy Extended Inverter

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module PRODUCT SELECTION DATA. Compact design

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

38RBS Air-Cooled Condensing Units. Nominal cooling capacity: kw. Features. Easy and fast installation

TOSHIBA AIR CONDITIONING

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

ELFOEnergy Extended Inverter

Water-cooled chillers with High Speed Centrifugal Compressors

AR Ductable Air-Cooled Liquid Chillers Ductable Reversible Air-to-Water Heat Pumps

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw

LIQUID CHILLER HEAT PUMP kw 30RB/30RQ - R410A. A Multi-Talented Performer

30RB /30RQ

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

Modular Air Cooled Scroll Chillers

30HXC Nominal cooling capacity kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

High temperature air-to-water heat pumps

30XAS A Air-Cooled Liquid Chillers. Nominal cooling capacity kw 50 Hz. Features and advantages. Very economical operation

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

Product Line Introduction. Karl Zhang Technical support engineer

THE HEAT PUMP CHOICE OF PROFESSIONALS

AQUAHEAT ADVANCE SPLIT

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

Compact and silent Scroll compressors All-season operation

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

EWAD-TZB. Screw inverter chiller. High efficiency chiller for comfort and process cooling

AQUASNAP AIR CONDITIONING MADE SIMPLE 30RA/30RH AQUASNAP LIQUID CHILLERS HEAT PUMPS

SHORAI. hatever you need. Do you want to improve your quality of life?

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant

Transcription:

PRODUCT SELECTION DATA Monobloc inverter Compact, reliable and efficient More than a Heat Pump Reversible Air to Water Heat Pump 0AW CARRIER participates in the ECP programme for LCP/HP Check ongoing validity of certificate: www.eurovent-certification.com www.certiflash.com Original document

0AW Nominal heating capacity 4-1 kw Nominal cooling capacity -16 kw The new reversible AquaSnap PLUS air-to-water heat pumps/chillers with built-in inverter technology were designed for residential and light commercial applications. They offer excellent energy efficiency values, exceptionally quiet operation and meet the most stringent operating temperature demands. The units integrate the latest technologi cal innovations: Non-ozone depleting refrigerant R4A, DC inverter twin-rotary compressors, low-noise fan and microprocessor control. With exceptional energy efficiency values the inverter mini-chillers qualify for local tax reductions and incentive plans in all EU countries. The 0AW units were specifically designed for ease-ofinstallation and service and underline Carrier s reputation for highest product quality and reliability. For added flexibility the AquaSnap PLUS units are available with or without hydraulic module. The AquaSnap PLUS can be used with complementary accessories to suit the installation - 80HMA Comfort modules, 0 or 00 litres domestic hot water tank with or without thermal solar panel connection. The AquaSnap PLUS heat pump systems can be used with a wide choice of Carrier terminal fan coil units - cassettes, low, medium and high-pressure satellite units, console units, underceiling units and high-wall units. Ecodesign is the European Directive that sets mandatory requirements for Energy related Products (ErP) to improve their energy efficiency. Carrier supports initiatives to reduce the environmental impact of its products. Input and output connections to the three-way valve for connection to a domestic hot-water buffer-tank. Provides increased flexibility for any application. Leaving water temperature up to 60 C for radiator and domestic hot water applications. Plug-and-play control for failsafe serviceability. Alarm input to force the unit off for increased safety, and matching with external control systems or safety devices. Output to operate an additional water pump for increased installation flexibility. Advanced technology Electronic system management: several sensors placed in key positions in the refrigerant circuit electronically detect the operational system status. Two microcontrollers receive the input from the sensors, manages them using advanced control algorithms and optimises the refrigerant flow and the functioning of all core components - the compressor, fan motors and the pulse modulation valve. The pulse modulation valve, a bi-flow electronic expansion device, optimises the refrigerant amount in the circuit and the superheat, preventing refrigerant migration back into the compressor. This device further enhances high system performance and reliability. The air management system, consisting of the propeller fan, orifice and air discharge grille guarantees minimised noise levels. New patented fan blade shape and grille profile with low pressure drop Features Wide operating range in both heating and cooling mode offering high performance in a wide temperature range. DC inverter twin-rotary compressors with Pulse Amplitude Modulation (PAM) and Pulse Width Modulation (PWM) for enhanced reliability, low energy consumption and smooth vibration-free operation under all operating conditions. Variable-speed fans with an innovative patented fan blade shape ensure improved air distribution at exceptionally low noise levels Pre-set or customised selection of the appropriate climate curve for stable output capacity to match the heat load. Output to link and integrate the unit with existing heat sources or a back-up heating source (single or dual-energy approach) for increased savings and optimum comfort all year round. Connection and control of an external dehumidifer through the Comfort TM Series programmable thermostat AW-CS1 to monitor and regulate the relative humidity. 2

Advanced performance The AquaSnap PLUS heat pump systems have an extremely high energy efficiency ratio in both cooling and heating mode, ensuring significant energy savings. Large, efficient coils and optimised circuiting ensure that all combinations meet the European tax rebate efficiency targets. Efficiency at part load conditions (seasonal energy efficiency) reaches the highest level in the industry. Year-round comfort - the advanced technology used in the new AquaSnap PLUS heat pump condensing units provides optimised comfort levels for the end users, both in terms of water temperature control and quietness. The desired temperature is quickly reached and effectively maintained without fluctuations. The 0AW offers optimised individual comfort levels - both in winter and in summer. Wide temperature operating range: AquaSnap PLUS heat pumps can operate efficiently in extreme temperature conditions. To suit the requirements of IT applications, the new AquaSnap PLUS can work at low-ambient conditions in cooling mode (down to 0 C and up to 46 C outside temperature). For end user comfort the units also operate down to - C outdoor temperature in heating mode, and in the summer season they produce hot water up to 60 C at up to 0 C outside temperature for domestic hot water applications. Various power cable outlet options: pre-punched holes in the cabinet panels permit cable exit on the side, front or rear. Dealer service tool connection kit includes the software and connections to monitor the operating parameters from a personal computer, giving an easy-to-read display with visual graphs and statistics indicators. All 0AW units are equipped with 1 inch gas MPT water connections. Option for an integrated hydronic module reduces space requirements and simplifies the installation. Only the power and the water supply and return piping need to be connected. Environmental care Non-ozone depleting refrigerant R4A. Chlorine-free refrigerant of the HFC group with zero ozone depletion potential. High-density refrigerant, therefore less refrigerant required. Very efficient - gives an increased energy efficiency ratio (EER). The components of AquaSnap PLUS heat pump systems are free of any hazardous substances. The new packaging ensures high protection during transport and handling and is 0% recyclable. Fast and simple installation and service Easy access to all internal components: simply undo three screws to remove the complete front panel to access the refrigerant piping connections, control box and electrical connections, as well as the compressor and other key parts. Advanced circuit design and component selection has resulted in a compact unit with an exceptionally small footprint that is easy to transport even through narrow doors. Reduced operating weight and a handle on the unit panels to facilitate transport. No additional buffer tank required, simplyfing and speeding up the installation process. bar pressure relief valve as standard. Two or three-litre internal expansion tank. High-temperature refrigerant protection. Water flow switch to ensure that the circuits contain enough water to operate correctly. Condensate drain piping connection to the unit includes a leak-proof pipe rubber joint. Specially shaped anchorage feet ensure correct and safe unit fixing to the foundation. The Comfort TM Series programmable thermostat periodically runs system checks to monitor and assess the unit operating parameters (standard parameters for the H version (AC) are C LWT in heating and 7 C LWT in cooling, and for the X version (CHF) C LWT in heating and 1 C LWT in cooling,). If a problem occurs, troubleshooting fault codes and messages help the service technician to identify the fault.

DC inverter twin-rotary compressor Advanced technology providing maximum energy-efficiency with high capacity available at peak conditions and optimised efficiency at low and mid compressor speeds. The AquaSnap PLUS heat pump DC inverter uses Intelligent Power Drive Unit (IPDU) hybrid inverter technology, combining two electronic management logics: Pulse Amplitude Modulation (PAM) and Pulse Width Modulation (PWM) for optimised compressor operation in all conditions, minimised temperature fluctuations, and providing perfect individual comfort control with significantly reduced energy consumption: PAM: pulse amplitude modulation of the direct current controls the compressor at maximum load conditions (start-up and peak load), increasing the voltage at fixed frequency. The compressor works at high speed to rapidly achieve the desired temperature. PWM: pulse width modulation of the direct current controls the compressor at partial load conditions, adjusting the frequency at fixed voltage. The compressor speed is fine-tuned and the system provides high-level comfort (no temperature fluctuations) at exceptionally efficient working conditions. Superior reliability Exceptional endurance tests Third-party testing and certification - all performances are certified by Eurovent and unit safety is certified by IMQ. All units are tested at various stages on the production line for circuit leakage, electrical compliance, water and refrigerant pressures. End-of-line test of all unit operating parameters. Corrosion resistance test. Accelerated ageing test on critical components and complete assembled units, simulating thousands of hours of continuous operation Packaging crash test to ensure that the units are adequately protected against accidental shocks. Extensive field and site testing. Corrosion-resistant casing Economical operation Compressor frequency is increased continuously up to the maximum level. This ensures that there are no current draw peaks in the start-up phase and safe connection to a singlephase power supply even in large-capacity systems. The maximum operating current of AquaSnap PLUS systems is below 7.2 A (systems up to 4 kw) and below 2 A for larger systems (12 kw). Inverter ramp-up speed makes soft starts unnecessary and ensures immediate maximum power. The two rotary compression cylinders, offset from each other by 180, and the DC brushless motor with the shaft in perfect balance ensure reduced vibration and noise, even at very low operating speeds. This results in an extremely wide range between minimum and maximum capacity with continuous operation, guaranteeing that the system is always optimised and provides maximum comfort at exceptionally high efficiency levels. Twin-rotary cylinders, low vibrations and low load to the shaft ensure highest compressor reliability and a long trouble-free operating life. All DC brushless twin-rotary compressors are equipped with crankcase heaters as standard. A double compressor shield for acoustic insulation further reduces noise levels. Increased energy efficiency at part load The exceptionally high energy efficiency of the AquaSnap PLUS heat pumps is the result of a long qualification and optimisation process. Use of ambient air as primary source of energy in domestic heating applications significantly reduces the overall energy consumption and minimises CO 2 emissions. Night mode operation at reduced compressor speed, resulting in low-noise operation and a significant reduction in energy consumption. Easy-to-set and economical silent mode, reducing the compressor speed. R4A refrigerant is easier to use than other refrigerant blends. 4

GMC board The new GMC controller was specifically developed for the AquaSnap PLUS inverter heat pumps, and incorporates new control algorithms. It features customised or pre-defined climate curves, domestic hot water control, a night-time noise reduction function, a defrost/alarm output signal, an external heat source, a pump block prevention function, freeze protection and compressor operation management. User interfaces The AquaSnap PLUS can use the following user interfaces: the AW-CS1 Comfort TM Series programmable thermostat with easy-to-read LCD screen. It provides enhanced control capability for maximised performance, reliability and indoor comfort and has extended programming features such as weekly scheduling and dehumidifier/ humidifier signals. The sleek contemporary design blends in with any room decor. the AquaSnap PLUS AW-RC1 remote controller dry contacts Comfort TM Series programmable thermostat AW-CS1 Remote controller AW-RC1 Type key 0AW H 006 H D 9 Power supply: 9 = Three-phase + neutral Liquid chilling packages/ heat pumps Air-to-water heat pump H - Standard version Unit options H - With hydronic kit X - Without hydronic kit Nominal size 004 - nominal size 4 kw 006 - nominal size 6 kw 008 - nominal size 8 kw 012 - nominal size 12 kw 01 - nominal size 1 kw Options and accessories Options Description Advantages Use Additional outdoor sensor Additional outdoor sensor AW-RAS01 Better reading of outdoor air temperature 0AW 004-01 Remote controller AW-RC1 remote controller On/off, heating/cooling and ECO mode 0AW 004-01 Programmable thermostat AW-CS1 Comfort TM series programmable thermostat Extensive control features like weekly scheduling 0AW 004-01 80HMA comfort module Domestic hot water tank 0 or 00 l, 1 coil Domestic hot water tank 0 or 00 l, 2 coils sizes with integrated system control, expansion vessel and electric booster heating or boiler backup Complementary heating system 0AW 004-01 Domestic hot water tank 0 or 00 l Storage, 0 l or 00 l of domestic hot water 0AW + 80HMA Domestic hot water tank 0 or 00 l with thermal solar panel connection Note: All 0AWH sizes are compatible with 80HMA comfort module range and domestic hot water tank models. Please refer to 80HMA documentation to get the option codes and the list of complementary accessories. Please consider that 80HMA is necessary to manage water sensor and electric heater integrated into DHW tank. Storage, 0 l or 00 l of domestic hot water 0AW + 80HMA

Physical data 0AW 004 006 008 012 01 12-Ph 1-Ph Cooling H version C1 Nominal capacity kw. 4.7.84.24 1.04. 1.00 Full load performances* C1 EER kw/kw.02.00 2.98 2.96 2.9.00 2.91 C1 Eurovent class cooling B B B B B B B C2 Nominal capacity kw 4.9 7.04 7.84 1.4 16.04 1. 16.00 C2 EER kw/kw 4..70.99.66.8 4.1.81 C2 Eurovent class cooling A B A B A A A Seasonal efficiency* ESEER kw/kw 4.6 4.1 4.1 4.22 4.1 4.4 4.1 Heating H version H1 Nominal capacity kw 4.07.76 7.16 11.86 14.46 12 1 Full load performances* H1 COP kw/kw 4.1 4.28.97.9 4.09 4. 4.2 H1 Eurovent class cooling A A B B A A A H2 Nominal capacity kw.87.76 7.6 12.91 1.96 11. 14. H2 COP kw/kw.26.0.19.0.2..0 H2 Eurovent class cooling A B B B A A A H Nominal capacity kw 4.27.4 7.2.89 12.6 11.4 12.17 H COP kw/kw 2.92 2.77 2.81 2.79.02.12 2.98 Seasonal efficiency** H SCOP kw/kw..7 2.84 2.9.2.47. H Ƞs heat % 18 12 111 11 127 16 10 H Prated kw.28 4.22 4.6 8.68 9.0 8.8 9.7 H Annual energy consumption kwh 1900 271 67 6077 748 497 806 H Energy efficiency class A++ A++ A+ A+ A++ A++ A++ Sound levels Standard unit Sound power level (1) (H) db(a) 62 62 64 67 68 68 68 Sound pressure level at 4m (2) (H) db(a) 42 42 44 47 48 48 48 Sound power level (1) (C1) db(a) 64 64 6 68 69 69 69 Sound pressure level at 4 m (2) (C1) db(a) 44 44 48 49 49 49 Dimensions Length mm 908 908 908 908 908 908 908 Depth mm Height mm 821 821 821 16 16 16 16 Operating weight () Unit without circulator (X version) kg 4 8 66 1 9 11 11 Unit with circulator (H version) kg 7 61 69 4 112 116 116 Compressors DC Inverter Twin-Rotary Refrigerant R4A Circuit charge () kg 1.19 1. 1.81 2..8 2..8 CO 2 eq. 2. 2.8.8.1 7.1.1 7.1 Air heat exchangers Copper tubes and aluminium fins Fans Variable speed blades fan Quantity 1 1 1 2 2 2 2 Water heat exchanger (X version) Water pressure drop (C1) kpa 8 28 28 Water pressure drop (H1) kpa 17 12 14 2 2 Water pressure drop (H2) kpa 16 12 14 29 1 29 1 Min. system water content l 14 21 28 42 49 42 49 Max. water-side operating pressure kpa 00 00 00 00 00 00 00 Hydronic module (H version) Pump Variable speed circulator Expansion tank volume l 2 2 2 Availabale static pressure (C1) kpa 6 6 66 76 66 76 66 Availabale static pressure (H1) kpa 60 60 6 70 8 70 Availabale static pressure (H2) kpa 62 60 72 60 7 8 Min. system water content l 14 21 28 42 49 42 49 Max. water-side operating pressure kpa 00 00 00 00 00 00 00 Water connections with or without hydronic module Diameter inch 1 M 1 M 1 M 1 M 1 M 1 M 1 M Outside tube diameter mm 2.4 M 2.4 M 2.4 M 2.4 M 2.4 M 2.4 M 2.4 M Chassis paint colour Beige * In accordance with standard EN111-:1 ** In accordance with standard EN1482:1, average climate C1 Cooling mode conditions: evaporator water entering/leaving temperature 12 C/7 C, outside air temperature C, evaporator fooling factor 0 m² K/W C2 Cooling mode conditions: evaporator water entering/leaving temperature 2 C/18 C, outside air temperature C, evaporator fooling factor 0 m² K/W H1 Heating mode conditions: Water heat exchanger water entering/leaving temperature 0 C/ C, fouling factor 0 m 2 K/W. Outside air temperature 7 C db/6 C wb, H2 Heating mode conditions: Water heat exchanger water entering/leaving temperature C/ C, fouling factor 0 m 2 K/W. Outside air temperature 7 C db/6 C wb, H Heating mode conditions: Water heat exchanger water entering/leaving temperature 47 C/ C, fouling factor 0 m 2 K/W. Outside air temperature 7 C db/6 C wb, (1) In db ref= -12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-db(a)). Measured in accordance with ISO 9614-1. (2) In db ref µpa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-db(a)). For information, calculated from the sound power level Lw(A). () Weights are guideline only. Refer to the unit nameplate Eurovent certified values 6

Electrical data 0AW 004 006 008 012 01 012-Ph 01-Ph Power supply V-ph-Hz 20-1- 20-1- 20-1- 20-1- 20-1- 0-N- 0-N- Voltage range V 198-264 198-264 198-264 198-264 198-264 76-424 76-424 Full load current A 9 11 14..7 22.6 11.1 11.1 Fuse rating A 16 16 2 2 16 16 Main power cable section mm 2 2. 2. 2. 2. 2. 2. 2. Sound power levels Lw Cooling mode 0AW Octave bands, Hz Sound power levels 12 2 0 00 00 00 8000 004 db 61 68 62 6 1 47 41 db(a) 64 006 db 61 68 6 6 46 db(a) 64 008 db 66 62 6 9 6 1 db(a) 6 012 db 70 6 67 62 8 7 db(a) 68 01 db 70 68 66 64 61 8 db(a) 69 012-Ph db 70 68 66 64 61 8 db(a) 69 01-Ph db 70 68 66 64 61 8 db(a) 69 Heating mode 0AW Octave bands, Hz Sound power levels 12 2 0 00 00 00 8000 004 db 67 62 61 6 47 4 db(a) 62 006 db 62 64 62 48 4 db(a) 62 008 db 66 6 6 7 4 2 db(a) 64 012 db 70 66 66 61 7 4 46 db(a) 67 01 db 72 68 67 6 9 6 db(a) 68 012-Ph db 72 68 67 6 9 6 db(a) 68 01-Ph db 72 68 67 6 9 6 db(a) 68 Operating limits Cooling mode Heating mode Maximum outside temperature 46 C 0 C Maximum leaving water temperature 18 C 60 C Minimum outside temperature 0 C (0AWH 004 + 006: C) - C Minimum leaving water temperature 4 C C Operating range, heating mode Operating range, cooling mode 70 Leaving water temperature, C 60 0-2 - -1 - - 0 1 2 0 Leaving water temperature, C 18 16 14 12 8 6 4 0AWH 006 0AWH 004 Outside air temperature, C 2 0-0 1 2 0 Outside air temperature, C 7

Available static pressure, kpa Available static pressure (units with hydronic module) 0AWH 004H Available static pressure, kpa BB B Pressure High speed drop curves Medium (units speed without Low speed hydronic module) 0AWH 004X Pressure drop, kpa 0 0.0 0.1 0.2 0. 0.4 0. 0 2 1 0 0 0,1 0,2 0, 0,4 0, 0,6 0AWH 006H Available static pressure, kpa 0 0,0 0,1 0,2 0, 0,4 0, 0.0 0.1 0.2 0. 0.4 0. 0.0 0 0.0 0.1 0,.1 0.2 0,2 0.2 0. 0, 0.4 0,4 0. 0. 0, 0.6 0.60,6 A Water flow A rate, l/s Water flow Arate, A l/s 0AWH 012H + 0AWH008H 0AWH012H 01H 0AWH012H - 0AWH01H 60 7 90 9 70 90 0AWH 008H 80 8 0AWH012H + 01H 6 60 70 80 7 9 7 60 70 90 70 8 6 6 80 60 60 7 0 70 2 0 0 6 60 B B2 1 B 0 10 2 2 0 0 0 1 0.0 0.1 0.2 0. 0.4 0. 0.6 0.7 0.0 0 2 0.1 0,1 0.,2 0. 0, 0.4 0,4 0. 0, 0.6 0,60.7 0,7 0.8 0, 0.9 1.0,9 8 0 0 0,1 0,2 0, 0,4 0, 0,6 Water flow A rate, l/s Water flow Arate, A l/s 0.0 0.1 0.2 0. 0.4 0. 0.6 0.7 0.0 0.1 0.2 0. 0.4 0. 0.6 0.7 0.8 0.9 1.0 High speed Medium speed Low speed A A A A 0AWH 008H Pressure drop, kpa B 70 6 60 0 2 1 70 70 60 60 0 2 0 0.00 0.0 0. 0.1 0. 0.2 0.0 0. 0. 0. 0AWH 008X B 7 70 6 60 0 2 1 6 0 1 0AWH004H 004H Water flow rate, l/s A Water flow rate, l/s Pressure drop, kpa Pressure drop, kpa Available static pressure, kpa 7 7 60 70 70 6 6 60 60 B 0 B 2 0 0 2 2 1 1 1 0AWH 006X B 0 2 1 2 0 0 0,1 0,2 0, 0,4 0, 0,6 Water flow rate, l/s 0AWH 012X + 01X B 60 0 0 0AWH006H 006H 0AWH006H 0 0,1 0,2 0, 0,4 0, 0,6 0,7 0,8 0,9 A Water flow rate, l/s 8

Dimensions, mm 0AW 004-008 0AW 012-01 0AW A B C D E F G H L 004 908 821 26 87 6 466 60 006 908 821 26 87 6 466 60 008 908 821 26 87 6 466 60 012 908 16 26 174 6 7 44 69 01 908 16 26 174 6 7 44 69 Clearances, mm 0 0 1 1 1 00 1 00 0 00 00 0 1 00 00 00 00 00 00 00 0 00 00 10 00 0 9

Heating capacities in accordance with EN111-:1 0AWH units Outside air dry-bulb (wet-bulb) temperature, C - (-21) -1 (-16) -7 (-8) LWT Qh COP q Qh COP q Qh COP q C kw kw/kw l/s kw kw/kw l/s kw kw/kw l/s Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom 0AWH004H 1.22 0. 1.22 1.16 1.80 1.16 0.08 2. 0.49 2.67 2.00 2. 1.90 0.112 2. 0.2 2.80 2. 2. 2.0 0.119 0AWH006H.00 0..11 2.06 2. 2.00 0.14. 0.60.26 2.1 2.47 2.21 0.1.44 0.64. 2.1 2.69 2. 0.164 0AWH008H 1.76 0.6 1.76 2.46 2. 2.46 0.084. 0.7.70 2.47 2.64 2.00 0.1.76 0.78 4. 2.6 2.81 2. 0.180 0AWH012H.22 1..22 2.08 2. 2.08 0.14 6.44 1.9 7.28 2.28 2.1 2.26 0.08 6.94 2. 7. 2.2 2.6 2. 0.2 0AWH01H 4. 1.26 4. 1.78 1.84 1.78 0.21 7.42 1.6 8.0 2.6 2.42 2. 0. 7.80 1.76 9. 2. 2.7 2.47 0.82 0AWH012H9 4.01 1.4 4.01 1.9 1.90 1.9 0.14 6.68 1.74 7.2 2.1 2.6 2.1 0.286 7.12 1.88 8.7 2.66 2.74 2. 0. 0AWH01H9 4. 1.6 4. 1.78 1.88 1.78 0.177 7.42 1.76 8. 2. 2.47 2. 0. 8.00 1.90 9.46 2.60 2.62 2. 0.82 0AWH004H 1.18 0. 1.18 1.07 1.7 1.07 0.06 2.28 0.44 2.6 1.8 2. 1.80 0.9 2. 0.49 2.60 2.1 2.8 2.00 0.11 0AWH006H 1.44 0.44 1.44 1.82 2.02 1.82 0.069. 0.9.24 2.1 2.1 2.0 0.1. 0.64. 2. 2.9 2.11 0.16 0AWH008H 1.27 0.7 1.27 2.00 1.96 2.00 0.061. 0.71.60 2.11 2.26 1.6 0.160.8 0.76 4.00 2.2 2. 1.70 0.184 0AWH012H.02 1.2.02 1.96 2.00 1.96 0.144 6.04 1.8 6.82 2. 2.14 2.08 0.288 6.6 2.01 7. 2.19 2.2 2.17 0.17 0AWH01H.00 1.28.00 1.70 1.7 1.70 0.14 7.0 1. 7.98 2.08 2.14 2.06 0.8 7.6 1.76 9. 2. 2.26 2.17 0.82 0AWH012H9.00 1.9.00 1.72 1.74 1.72 0.1 6. 1.7 7.2 1.82 2.16 1.82 0.1.87 1.77 8.72 2.26 2.28 2. 0.281 0AWH01H9.00 1.8.00 1.70 1.7 1.70 0.1 7.0 1.62 8.0 1.80 2.14 1.80 0.191 8.00 1.76 9.44 2.26 2.26 2.1 0.82 0AWH004H 1.17 0. 1.17 1.60 1.80 1.60 0.06 2.44 0.44 2.49 1.78 1.91 1.77 0.117 0AWH006H 1.8 0.6 1.8 1.76 1.9 1.76 0.07.28 0.61. 1.90 2.06 1.8 0.17 0AWH008H 0.8 0.69 0.8 1.88 1.98 1.88 0.09.60 0.74.96 1.86 2.09 1.6 0.172 0AWH012H 2.87 1.69 2.87 1.67 1.69 1.67 0.17 6.7 1.9 7. 1.80 1.8 1.78 0.04 0AWH01H.00 1..00 1.74 1.80 1.74 0.14 7. 1.6 7.94 1.8 1.90 1.74 0.8 0AWH012H9 2.89 1.71 2.89 1.7 1.82 1.7 0.111.79 1.67 6.97 1.86 1.92 1.84 0.277 0AWH01H9.00 1.9.00 1.78 1.80 1.78 0.124 6.49 1.6 7.94 1.88 1.90 1.76 0.1 0AWH004H 60 2.2 0. 2. 1.7 1.87 1.72 0.7 0AWH006H.01 0.6.06 1.69 1.80 1.62 0.144 0AWH008H 1.8 0.6 2.22 1.7 1.8 1. 0.087 0AWH012H 6.12 1.8 6.92 1.6 1.9 1. 0.29 0AWH01H 6.7 1.1 7.7 1.64 1.67 1.61 0.14 0AWH012H9.41 1. 6.7 1.6 1.7 1.2 0.28 0AWH01H9 6.66 1.1 7.4 1.1 1. 1.42 0.18 Outside air dry-bulb (wet-bulb) temperature, C -(-4) 0 (-1) 2 (1) LWT Qh COP q Qh COP q Qh COP q C kw kw/kw l/s kw kw/kw l/s kw kw/kw l/s Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom 0AWH004H 2.80 0.7.1 2.60 2.82 2.80 0.14 2.90 0.61. 2.90.02.00 0.19.2 0.64.60.00.12.1 0.1 0AWH006H.7 0.70.82 2.77 2.97 2.6 0.179.99 0.74 4.06 2.97.18 2.84 0.191 4. 0.78 4.27.07.29 2.94 0.1 0AWH008H 4.6 0.88 4.8 2.81.04 2.8 0.8 4.74 0.96.24 2.94.21 2.4 0.226.12 1.01.2 2.99.27 2.64 0.2 0AWH012H 7.8 2.7 8.8 2.8 2.90 2.8 0.74 8. 2.7 9.61.00.0 2.97 0.6 8.7 2.87.11.11.16.08 0.418 0AWH01H 8.98 1.97.21 2.81 2.88 2.78 0.429 8.99 2.1 11.0.04.12.00 0.464 9. 2. 12.07..28.16 0.487 0AWH012H9 7.68 2.11 9.1 2.82 2.97 2.72 0.67 7.8 2.28 9.92 2.84.11 2.74 0.7 8. 2.62 11.02.17.28.08 0.9 0AWH01H9 8.49 2.1.4 2.7 2.94 2.69 0.6 8.69 2.0 11.1 2.77.08 2.70 0.41 9. 2.6 12...24.07 0.4 0AWH004H 2.70 0.2.0 2. 2. 2.6 0.129 2.80 0..2 2.2 2.68 2. 0.14.00 0.60. 2.64 2.87 2.60 0.14 0AWH006H.76 0.69.80 2.1 2.1 2.21 0.180 4.00 0.72 4.02 2.9 2.9 2.29 0.191 4. 0.79 4.22 2.1 2.78 2. 0.1 0AWH008H 4. 0.87 4.78 2.4 2.1 1.8 0.212 4.81 0.9. 2.42 2. 2.01 0.20.1 0.99.48 2. 2.69 2.11 0.246 0AWH012H 7.4 2.2 8. 2.1 2.4 2.29 0. 8.06 2.44 9.12 2.42 2.46 2. 0.8 8.48 2.74 9.9 2.61 2.67 2.7 0. 0AWH01H 8.98 1.97.21 2.4 2. 2.1 0.429 9.71 2.1 11.0 2.44 2.1 2.42 0.464 9. 2.47 11.4 2.60 2.71 2.6 0.487 0AWH012H9 6.2 1.99 9.44 2.9 2.4 2. 0.298 6.68 2.1 9.8 2.49 2. 2.4 0.19 7. 2.49.9 2.70 2.74 2.8 0.8 0AWH01H9 8. 1.97.48 2.9 2. 2.27 0.1 8.61 2.1 11.04 2.49 2.1 2.7 0.412 9.0 2.47 11.88 2.6 2.71 2.1 0.444 0AWH004H 2.77 0.48 2.8 1.92 2.04 1.89 0.12 2.99 0..0 2.01 2.14 1.98 0.14.1 0.6.21 2.1 2.27 2.11 0.1 0AWH006H.70 0.67.7 2.04 2. 1.97 0.177.97 0.70 4.00 2.14 2.1 2.07 0.19 4.19 0.78 4.19 2.26 2.44 2. 0.2 0AWH008H 4.2 0.84 4.9 1.97 2.19 1.76 0.2 4. 0.91 4.98 2.08 2. 1.8 0.21 4.86 0.96.24 2. 2. 2.00 0.22 0AWH012H 7.44 2.2 8.41 1.98 2.01 1.96 0. 8.2 2. 9.1 2.08 2.11 2.06 0.9 8.66 2.71 9.61 2. 2.2 2.18 0.414 0AWH01H 7.99 1.86 8.4 1.98 2.0 1.86 0.82 8.26 2.02 8.7 2.08 2.1 1.9 0.9 8.97 2.0 9.47 2. 2.2 2.06 0.428 0AWH012H9 6. 1.88 7. 2.00 2.0 1.97 0.04 6.9 2.04 8.02 2. 2.1 2.06 0.0 7.49 2. 8.70 2.28 2.28 2.18 0.8 0AWH01H9 6.90 1.86 8.71 2.01 2.0 1.88 0. 7.6 2.02 8.9 2.11 2.1 1.97 0.61 7.96 2.0.18 2.24 2.2 2.08 0.8 0AWH004H 60 2.6 0.44 2.80 1.90 2.00 1.8 0.122 2.76 0.46.01 1.9 2.09 1.9 0.12 2.91 0.2.18 2.08 2.21 2.06 0.19 0AWH006H.9 0.6.48 1.80 1.9 1.7 0.162.68 0.68.80 1.89 2.02 1.82 0.176.87 0.72 4.01 1.99 2.1 1.92 0.18 0AWH008H 2.06 0.7 2.1 1.68 1.69 1.66 0.098 2.24 0.79 2.72 1.76 1.78 1.74 0.7 2. 0.84 2.86 1.86 1.88 1.8 0.112 0AWH012H 6.91 2.09 7.81 1.67 1.70 1.66 0. 7.49 2.27 8.47 1.7 1.78 1.74 0.8 7.89 2. 8.92 1.8 1.88 1.8 0.77 0AWH01H 6.7 1.71 7.86 1.76 1.79 1.74 0.2 7.04 1.8 8.21 1.8 1.87 1.82 0.6 7.41 2. 9.04 1.9 1.98 1.92 0.4 0AWH012H9.9 1.72 7.8 1.6 1.9 1.4 0.28.97 1.87 7.8 1.60 1.6 1.8 0.28 7.08 2.12 8.62 2.04 2.06 2.00 0.8 0AWH01H9 7.0 1.71 8.27 1.2 1.7 1.46 0.49 7. 1.8 8. 1.6 1.61 1. 0.8 8. 2. 9.67 1.98 2.04 1.9 0.8

Heating capacities in accordance with EN111-:1 0AWH units Outside air dry-bulb (wet-bulb) temperature, C 7 (6) (9) (19) LWT Qh COP q Qh COP q Qh COP q C kw kw/kw l/s kw kw/kw l/s kw kw/kw l/s Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom 0AWH004H 4.07 0.77 4.7 4.1 4..97 0.196 4. 0.8.14 4.47 4. 4.8 0.21.62 1.0 6.49..9. 0.269 0AWH006H.76 1.08 6.14 4.28 4.49.97 0.277 6.2 1.18 6.67 4.6 4.96 4.8 0.02 7.98 1.49 8.42 6.07 6.49.7 0.81 0AWH008H 7.16 1.4 8.00.97 4.17.44 0.44 7.82 1.46 8.69 4.26 4.6.76 0.7 9.87 1.84.97.46.84 4.81 0.472 0AWH012H 11.86.61 1..9.96.86 0.69 12.92.91 14.61 4.0 4.7 4.26 0.617 16.2 4.94 18..6.72.8 0.780 0AWH01H 14.46.18 16.2 4.09 4.17 4.01 0.69 1.74.46 17.47 4.48 4.9 4.42 0.72 19.89 4.7 21.6.87 6.02.80 0.9 0AWH012H9 12.00. 1.00 4.0 4.9 4. 0.7 12.86.70 16.1 4.68 4.7 4.7 0.614 16.14 4.67.24 6.0 6..89 0.771 0AWH01H9 1.00.44 17.41 4. 4.2 4.18 0.717 16.1.7 18.7 4.7 4.69 4. 0.771.24 4.72 2.49.89 6.14.86 0.967 0AWH004H.87 0.70 4..26..1 0.186 4.19 0.78 4.84.9.60. 0.0.17 1.00.97 4.02 4.27.9 0.247 0AWH006H.76 1.06 6.04.0.24 2.91 0.277 6.24 1.14 6.49.18.4.08 0.298 7.70 1.41 8..77 4.07.66 0.68 0AWH008H 7.6 1.2 7.92.19. 2.84 0.4 8.0 1.44 8.7.44.74.08 0.84.02 1.82.7 4.4 4.7.89 0.479 0AWH012H 12.91.47 12.9.0.08.01 0.47 12.1.7 1.92.21.26.18 0.88 1.18 4.60 17.16.80.86.77 0.72 0AWH01H 1.96.07 1.92.2.29.17 0.669 1.0.0 17.12..49.6 0.719 18. 4.07. 4.0 4.14.99 0.886 0AWH012H9 11.. 14....0 0. 11.97.4 1.90..2. 0.72 1.0 4.11 18.92.8 4.18 4.0 0.718 0AWH01H9 14..07 16.2.0.29.21 0.69 1.90.0 18.11..49.1 0.760 18.92 4.07 21. 4.0 4.14.92 0.904 0AWH004H 4. 0.6 4.22 2.71 2.7 2.60 0.196 4.41 0.72 4.2 2.90 2.9 2.84 0.211.41 0.9..44..9 0.28 0AWH006H. 1.02.8 2.8 2.78 2. 0.28.98 1. 6. 2.72 2.9 2.70 0.286 6.87 1. 7.0.2.4.18 0.28 0AWH008H 6.70 1.2 7.46 2.0 2. 2.12 0.2 7.2 1. 8.0 2.87.07 2.68 0.46 9.0 1.68.0.49.7. 0.42 0AWH012H.27.6 11. 2. 2.4 2.48 0.49 11.46.61 12. 2.6 2.68 2.6 0.47 1.8 4.42 14.60.08.1.08 0.662 0AWH01H 11.66 2.78 12. 2.82 2.87 2.6 0.7 12.70 2.98 1.41 2.97.04 2.78 0.607 1.02.66 1.76.2.61.1 0.718 0AWH012H9 11.0 2.81 1.09 2.80 2.90 2.78 0.28 11.88.01 14.2.02.07 2.9 0.68 14.91.69 17.1.6.64. 0.712 0AWH01H9 12.00 2.78 1.26 2.8 2.87 2.6 0.7 1.07 2.98 16.81.02.04 2.80 0.624 1.68.66.02.8.61. 0.749 0AWH004H 60.8 0.61 4.18 2.48 2.70 2. 0.18 4.07 0.68 4.44 2.61 2.90 2.8 0.19 4.94 0.91.44.07..04 0.26 0AWH006H.00 0.9.07 2.2 2.41 2.2 0.29.2 0.99.2 2.7 2. 2.7 0.24 6.07 1.19 6.07 2.79 2.96 2.79 0.29 0AWH008H.04 1.08.70 2.12 2.14 2. 0.1.2 1.1.9 2.26 2.28 2.24 0.1.9 1.41 4.81 2.71 2.74 2.69 0.189 0AWH012H.19.09 11.00 2.09 2.12 2.08 0.487.84.28 11.2 2. 2.2 2. 0.18 11..9 11.60 2.6 2.60 2.6 0. 0AWH01H.0 2.2 11.24 2. 2.2 2. 0.479 11.2 2.9 11.2 2.0 2. 2.0 0.7 11.90.12 11.90 2.48 2.72 2.48 0.68 0AWH012H9.6 2.4 12.9 2.69 2.70 2.6 0.9 11.8 2.62 1.8 2.81 2.87 2.78 0. 14.21.1 16.6.7.42.2 0.679 0AWH01H9 12.80 2.2 14. 2.60 2.68 2.4 0.612 1.69 2.9 1.97 2.7 2.84 2.69 0.64 16.0.12 19.02.29.9.21 0.766 Legend LWT - Leaving Water Temperature, o C Qh - Heating Capacity, kw Nom - Nominal Min - Minimum Max - Maximum COP - Coefficient of Performance q - Condenser water flow rate, l/s Application Data Standard units, refrigerant: R-4A Condenser entering/leaving water temperature difference: K Condenser fluid: water Fouling Factor: 0.m 2 K/W Performance in accordance with EN 111-: 1 11

Cooling capacities in accordance with EN111-:1 0AWH units Outside air Temperature, o C 1 2 LWT Qc EER q Qc EER q Qc EER q o C kw kw/kw l/s kw kw/kw l/s kw kw/kw l/s Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom 0AWH004H 1.29 1.17 1.29 8.1 9.24 8.1 0.062 1.16 1.0 1.16 7.21 8.01 7.21 0.0. 0.9...99. 0.167 0AWH006H 1.14 1.04 1.14 9.6. 9.6 0.04 1.00 0.91 1.00 8.22 9.1 8.22 0.048.16 0.79.16.66 7..66 0.247 0AWH008H 6.16 0.7 7.1 8.68 9.67 8.12 0.294.60 0.2 6.66.71 6.9. 0.268.0 0.47 6.00.97 4.7.8 0.241 0AWH012H 14.66 4.62 16.97.94 8.6 4.81 0.701 11.8 4.26 1.6 4.94.82 4.49 0.6.81.89 12.21.69 4.2.41 0.16 0AWH01H 19.14 4.4.01.1 8.94 4.7 0.914 1. 4.18 1.70 4.69 6.01 4.69 0.72 14.01.82 14.4.8 4.42.6 0.669 0AWH012H9 1.79 4. 19.71.96 8.76 4.42 0.69 11.7 4. 1.86.19.89 4.9 0.4.41.74 14.49.72 4..48 0.497 0AWH01H9 19.14 4.4.01.1 8.94 4.7 0.914 1. 4.18 1.70 4.69 6.01 4.69 0.72 14.01.82 14.4.8 4.42.6 0.669 0AWH004H 7 1.4 1.0 1.4 9..22 9. 0.068 1.28 1.16 1.28 7.90 8.78 7.90 0.061.82 1.0.82.88 6..88 0.182 0AWH006H 1.26 1.1 1.26.14 11.27.14 0.06 1.11 1.01 1.11 8.91 9.90 8.91 0.0.61 0.88.61.88 7.9.88 0.268 0AWH008H 6.86 0.69 7.9 9.01.78 8.47 0.28 6.2 0.6 7.24 6. 7.80.89 0.299.6 0.6 6. 4.2. 4.08 0.269 0AWH012H 1.62.12 1.7 7.64 9.94 6.69 0.61 12.7 4.72 14.7.24 6.81 4.9 0.6 11.47 4.1 1.12.88 4.74.1 0.48 0AWH01H 17.7.02 18.11 7.4.6 7. 0.8 16.01 4.62 16.69.09 7.0 4.87 0.76 14.62 4.22 1.24.8.07.72 0.698 0AWH012H9 12.82 4.92 17.8 8.07.44 6.76 0.61 12.12 4. 16.86.69 7.1 4.77 0.79 11.14 4.14 1.9 4.0 4.97.6 0.2 0AWH01H9 17.7.02 18.11 7.4.6 7. 0.8 16.01 4.62 16.69.09 7.0 4.87 0.76 14.62 4.22 1.24.8.07.72 0.698 0AWH004H 1.47 1. 1.47 8.94 9.9 8.94 0.07 4.29 1.19 4.29 4.6 7.9 4.6 0. 0AWH006H 1.44 1.1 1.44 11.2 12.7 11.2 0.069 1.28 1.16 1.28 9.9 11.0 9.9 0.061 6.29 1.01 6.29 4.19 8.6 4.19 0. 0AWH008H 7.92 0.86 8.91 9.2 12. 8.99 0.78 7.22 0.78 8.12 6.68 9.07 6.4 0. 6.1 0.71 7. 4.61 6.9 4.44 0.11 0AWH012H 12.0.86 1.47.21 11.87 9.1 0.76 1.67.41 1.89.69 8.29 4.7 0.6 12.46 4.94 14.48 4.17.48.6 0.96 0AWH01H 14.72.7 1.2.87 1.22.64 0.70 17.04.29 18.19.69 9.24.14 0.814 1.4 4.82 16.8 4.2 6.0.97 0.742 0AWH012H9 11.7.62 1.01 11.2 12.9.28 0.4 1.2.18 18.6 6.44 9.0.0 0.6 12.2 4.7 16.74 4..9.89 0.84 0AWH01H9 14.72.7 1.2.87 1.22.64 0.70 17.04.29 18.18.69 9.24.14 0.814 1.4 4.82 16.8 4.2 6.0.97 0.742 0AWH004H 1 1.78 1.61 1.78.66 11.8.66 0.08.09 1.44.09.17 8.79.17 0.24 0AWH006H 1.9 1.9 1.9 14.7 14.7 14.7 0.076 1.6 1.42 1.6 11.68 12.97 11.68 0.074 7.41 1.24 7.41 4.72 9.86 4.72 0.4 0AWH008H 9.68 1.14.1. 1.2 9.8 0.462 8.8 1.04 9.9 7.66 11.19 7. 0.422 7.98 0.94 8.66.24 8.04.02 0.81 0AWH012H 7.11 7.11 7.11 1. 1. 1. 0.4 1.2 6.7 18.41 6.44.7 4.98 0.741 14.12.98 16.76 4.66 6.70.90 0.67 0AWH01H 6.9 6.9 6.9 17. 17. 17. 0.1 18.7 6..67 6.70 12.47.9 0.896 17.06.8 18.82 4.9 7.69 4.8 0.81 0AWH012H9 6.79 6.79 6.79 17.1 17.1 17.1 0.24 1.14 6.27.87 7.68 12.22.47 0.72 14.0.71 19.00.28 7. 4.29 0.671 0AWH01H9 6.9 6.9 6.9 17. 17. 17. 0.1 18.7 6..67 6.70 12.47.9 0.896 17.06.8 18.82 4.9 7.69 4.8 0.81 0AWH004H 18 1.96 1.78 1.96 11.70 1.00 11.70 0.094.6 1.9.6.6 9.62.6 0.266 0AWH006H 1.7 1.7 1.7 16.06 16.06 16.06 0.084 1.72 1.7 1.72 12.71 14.1 12.71 0.082 8.08 1.8 8.08.04.8.04 0.86 0AWH008H.7 1.1 11.46.86 16.89.7 0.1 9.80 1..47 8.24 12.46 7.87 0.468 8.86 1.08 9.46.62 9.02.7 0.42 0AWH012H 7.86 7.86 7.86 17.04 17.04 17.04 0.7 16.62 7.26 19.92 6.89 12.2.12 0.794 1.12 6.61 18.12 4.94 7.4 4.04 0.722 0AWH01H 7.6 7.6 7.6.06.06.06 0.6 19.77 7.07 22.16 7.1 14.41.86 0.9 17.98 6.4.16. 8.67 4.62 0.89 0AWH012H9 7.49 7.49 7.49 19.66 19.66 19.66 0.8 16.26 6.9 22.7 8.4 14.12.7 0.777 1.1 6.0.6.7 8. 4. 0.724 0AWH01H9 7.6 7.6 7.6.06.06.06 0.6 19.77 7.07 22.16 7.1 14.41.86 0.9 17.98 6.4.16. 8.67 4.62 0.89 12

Cooling capacities in accordance with EN111-:1 0AWH units Outside air Temperature, o C LWT Qc EER q Qc EER q o C kw kw/kw l/s kw kw/kw l/s Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom 0AWH004H.01 0.80.1 2.70 4.6 2.66 0.144 2.67 0.66 2.81 2.09. 2.00 0.127 0AWH006H 4.28 0.6 4.94 2.78.66 2. 0..78 0.1 4.6 2.11 4.28 1.92 0.18 0AWH008H 4. 0.42.2 2.84.41 2.74 0.21.91 0.6 4.6 2.0 2.44 1.96 0.187 0AWH012H 9.60.46.8 2.78.16 2.6 0.9 8.8 2.9 9.49 2.02 2.1 1.89 0.1 0AWH01H 12.. 12.87 2.7.29 2.68 0.9 9.24 2.90 9. 2. 2.41 2.16 0.441 0AWH012H9 9.60. 1.00 2.79.22 2.6 0.9 8.88 2.84 9. 2.8 2.6 2.12 0.424 0AWH01H9 12.. 12.87 2.7.29 2.68 0.9 9.24 2.90 9. 2. 2.41 2.16 0.441 0AWH004H 7. 0.89..02 4.92 2.84 0.18 2.91 0.7.0 2.2.70 2.16 0.19 0AWH006H 4.7 0.7..00.96 2.66 0.22 4.1 0.9 4.69 2.21 4.47 2.0 0.198 0AWH008H.84 0..80 2.98.8 2.91 0.29 4.7 0.44.06 2.17 2.77 2.09 0.9 0AWH012H.24.8 11.67 2.96.4 2.66 0.487 8.68.26 9.9 2.14 2.48 1.98 0.41 0AWH01H 1.04.7 1. 2.9.67 2.8 0.621 9.82..09 2.0 2.64 2.27 0.469 0AWH012H9..68 1.69.00.9 2.77 0.487 9..1.19 2.6 2.9 2.22 0.446 0AWH01H9 1.00.7 1. 2.91.67 2.8 0.621 9.82..09 2.0 2.64 2.27 0.469 0AWH004H.74 1.0.9.22.46.12 0.179.28 0.87.41 2. 4.06 2. 0.17 0AWH006H. 0.86.92. 6. 2.8 0.2 4.71 0.70.18 2. 4.76 2.24 0.22 0AWH008H.77 0.6 6.2.2 4..1 0.276.04 0..70 2.7.28 2.29 0.241 0AWH012H 11. 4.9 12.88..8 2.81 0. 9.14.7.9 2.1 2.7 2.11 0.47 0AWH01H 1.82 4.29 14.8.16 4.2.04 0.66.70.6 11.04 2..00 2.4 0.11 0AWH012H9 11. 4. 14.72.1 4.1 2.98 0..00.7 11.1 2.84 2.94 2.8 0.478 0AWH01H9 1.82 4.29 14.8.16 4.2.04 0.66.70.6 11.04 2..00 2.4 0.11 0AWH004H 1 4.46 1.26 4.7.74 6.6.9 0.21.88 1.08 4.00 2.82 4.67 2.80 0.186 0AWH006H 6.7 1.07 6.90.42 7.14.16 0.04.64 0.89 6.01 2.60.2 2. 0.27 0AWH008H 7.04 0.84 7.72.66.8.6 0.6 6.17 0.74 6.77 2.70 4.12 2.62 0.29 0AWH012H 12.60.2 14.91.42 4..06 0.602 9.89 4.2 11.69 2.9.1 2.2 0.47 0AWH01H 1.18.18 16.28.6.18.9 0.72 12.16 4. 12.62 2.70.9 2.70 0.81 0AWH012H9 12.60.08 16..84.08.2 0.602 11.12 4.1 12.7.0.2 2.64 0.1 0AWH01H9 1.18.18 16.28.6.18.9 0.72 12.16 4. 12.62 2.70.9 2.70 0.81 0AWH004H 18 4.9 1..22 4. 6.89.86 0.24 4.2 1. 4.6.0.04.0 0. 0AWH006H 7.04 1. 7.49.70 7.8. 0.4 6. 1.00 6. 2.74.4 2.74 0.296 0AWH008H 7.84 0.97 8.44.99 6.24.80 0.7 0.8 0.8 0.8 4.62 4.62 4.62 0.041 0AWH012H 1.4.88 16.12.66 4.9.21 0.6.4 4.99 12. 2.76. 2. 0.494 0AWH01H 16.04.72 17.1.8.7.60 0.764 1.0 4.8 1.7 2.86.94 2.86 0.62 0AWH012H9 1..60 17.48 4.1.6. 0.6 11.80 4.7 1.70.8.86 2.80 0.64 0AWH01H9 16.00.72 17.1.81.7.60 0.764 1.0 4.8 1.7 2.86.94 2.86 0.62 Legend LWT - Leaving Water Temperature, o C Qc - Cooling Capacity, kw Nom - Nominal Min - Minimum Max - Maximum EER - Energy Efficiency Ratio, kw/kw q - Evaporator water flow rate, l/s Application Data Standard units, refrigerant: R-4A Evaporator entering/leaving water temperature difference: K Evaporator fluid: Water Fouling Factor: 0.m 2 K/W Performance in accordance with EN 111-:1 1

Hydronic module The hydronic module reduces the installation time. The unit is factory-equipped with the main hydronic components required for the installation: variable speed circulator, expansion tank and safey valve. Hydronic components The water heat exchanger and the hydronic module are protected against frost down to - C, using pump cycling. The hydronic module is integrated into the unit without increasing its dimensions and saves the space normally used for the water pump. 0AWH - H models 1 7 2 1 7 4 6 6 2 4 8 0AWH - X models 1 1 2 2 4 4 Legend 8 1 Automatic purge valve 2 Water flow switch Pressure relief valve 4 Water temperature sensors Water circulation pump 6 Plug to unblock the pump 7 Expansion tank 8 Water drain cap 14

Suggested hydronic circuit installation 0AWH - H models 1 6 7 9 1 2 4 8 0AWH - X models 1 6 7 9 1 2 4 8 11 Legend 1 Ball valve 2 Water filter ( mesh/inch) Pressure gauge 4 Charge valve Drain valve (located at the lowest water circuit point) 6 Purge valve (located at the highest water circuit point) 7 Three-way valve 8 Domestic hot water tank 9 Terminals (fan coil units, underfloor heating, radiators Water pump 11 Expansion tank 1

Order No.: 1469-,.1. Supersedes order No.: 1469-,.1. Manufacturer reserves the right to change any product specifications without notice. Manufactured by: Carrier, Beroun, Czech Republic. Printed in the European Union.