Datasheet - TVS /B-M20

Similar documents
Datasheet - AZM 161SK-12/12RK-024

Datasheet - AZM ZRK 24 VAC/DC

Datasheet - AZM 161SK-12/12RK-024

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

Datasheet - MZM 100 ST2-1P2PWREM-A

Datasheet - MZM 100 ST-SD2PREM-A

Datasheet - MZM 100 B ST2-SD2PREM-A

SLC 220 E/R RFBS

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

PROTECT SRB 200EXi-1A

Conformity Approvals Rated insulation voltage Ui

Overload relays. General descriptions. Configuration of the front

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

ISIS SAFETY SYSTEM Installation guide

Switches compliant with ATEX directive

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Gas cylinder scale Model GCS-1

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Technical Data. Dimensions

Integrated Solutions Low Voltage Systems

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Operating Manual MS220KA and MSR220KA

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Original operating instructions Safety switch with guard locking AC901S AC902S

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Inductive slot sensor

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Multifunctional Gate Box MGB. More than safety.

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

BKA-EN Fire Damper. Additional operating instructions according to

Technical Data. General specifications. Rated operating distance s n 5 mm

BERNSTEIN Safety Rope Pull Switches SR and SRM

Flameproof Manual Call Points Series MCP

MICRO SWITCH GSX Series

BSK-RPR Fire Damper. Additional operating instructions according to

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

TUNNELS BOXES AND CONNECTORS

Safety Rope Pull Switches SRM, SR. General information on safety rope pull switches

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Technical Data. Dimensions

Operating Manual Distribution box

Power Supply Display Module PSDM. Installation and Operation Manual

One giant leap for safety: AZM400.

FAST RESPONSE TEMPERATURE SENSORS 42.11a

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Sensing light curtain as per DIN 18650/EN 16005

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

Soft Starter Centrifugal Pump Soft Starter Series

ATEX Safety Switches. More than safety.

Scha tschra Hei u g E c sure heater R sista ces chauffa tes Scha e astverwar i ge. Risca dat re a tic de sa Resiste cia ca efact ra 3105 XXX

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

Insulation fault evaluator EDS460-DG

Annubar Flowmeter Series

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Sensing light curtain as per DIN 18650/EN 16005

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

Safety in system: Protection for man and machine Innovations 2016/2017

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

TUNNELS BOXES AND CONNECTORS

TRASCO ATEX Couplings

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Annunciator Unit SACO 16 D1. Product Guide

Remote alarm indicator and test combination MK2430

Stego accessories for cabinets

TEMPERATURE-RESISTANT AND HEATED DIAPHRAGM GAS SAMPLING PUMPS

Machine Guarding and Safety

Annunciator unit. Application

ANNEX GD-CERT-EX-EN SIT

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

PLANET -DIN PAGE 12-2 PAGE 12-6 PAGE 12-5

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Rosemount 752 Fieldbus Remote Indicator

Flameproof Manual Call Points

Manual Power relay SR853

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

High bay LED lighting fixture

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar absolute) Press (bar g) (kg)

Operating Manual MS220DA

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Exp, pressurized systems

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

QTi DALI 1X28/54 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T5 ECG dimmable DALI for FL 16 mm

UL HAZARDOUS LOCATIONS SERVICES

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

Transcription:

Print - Create PDF - Create EXCEL file 21.04.2011-16:21:01h Datasheet - TVS 400-12/B-M20 Safety switch for hinged guards / Hinge safety switch / TVS 400 / TESZ thermoplastic enclosure Double-insulated Good resistance to oil and petroleum spirit 111,5 mm x 92 mm x 36 mm Simple fitting, especially on 40 mm profiles Universal fitting on guards hinged on left or right-hand side Fixing holes for M6 countersunk screws to DIN 965 2 cable entries M 20 x 1.5 (Minor differences between the printed image and the original product may exist!) Ordering details Product type description TVS 400-12/B-M20 Article number 1155809 EAN code 4030661176680 Approval Approval BG USA/CAN CCC Classification Standards EN ISO 13849-1 B10d Opener (NC) 20.000.000 Mission time 20 Years Global Properties Product name TVS 400 Standards EN 60947-5-1, BG-GS-ET-15

Compliance with the Directives (Y/N) Yes Materials - Material of the housings Plastic, glass-fibre reinforced thermoplastic, self-extinguishing - Material of the contacts Silver - Material of the hinge Aluminium Housing coating Weight 265 g Mechanical data Design of electrical connection Screw connection Cable entry M 20 x 1.5 2 Cable section - Min. Cable section 0,5 mm² - Max. Cable section 1 mm² Mechanical life > 1.000.000 operations Switching frequency max. 120/h Positive break angle 4 Positive break force 1 N additional hinge (Y/N) No additional hinge (Y/N) No mounting hinge (Y/N) Yes All indications about the cable section are including the conductor ferrules. Ambient conditions Ambient temperature - Min. environmental temperature - 25 C - Max. environmental temperature + 65 C Protection class IP65 Electrical data Design of control element Switching principle Number of auxiliary contacts Number of safety contacts Rated impulse withstand voltage Uimp Rated insulation voltage Ui Thermal test current Ithe Normally open contact (NO), Opener (NC) Creep circuit element 1 piece 2 piece 2.5 kv 250 V 2.5 A Utilisation category AC-15: 230 V / 2 A, DC-13: 24 V / 1 A Max. fuse rating 2 A gg D-fuse ATEX Explosion protection categories for gases Explosion protected category for dusts Dimensions Dimensions of the sensor - Width of sensor 111.5 mm - Height of sensor 92 mm

- Length of sensor 36 mm The additional hinge including mounting accessories is also available separately, part number Z 400 Plug connection and mounting kits for profile sections of the most common makes on request The opening angle has been set to 10 in factory. Until the limit of the mechanical life has been reached the angle can increase up to 6 under normal wear-out conditions. Diagram Note Diagram positive break NC contact active no active Normally-open contact Normally-closed contact Switch travel diagram Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel Ordering code TVS 400-(1)/(2) (1) 12 1 Normally open contact (NO) / 2 Opener (NC) 03 3 Opener (NC) (2) B with mounting hinge BZ with mounting and additional hinge Documents

Operating instructions and Declaration of conformity (jp) 1 MB, 10.12.2010 http://127.0.0.1/bilddata/drehbar/pdf/tvs400/bedien/jp/mrl_tvs400_jp.pdf Operating instructions and Declaration of conformity (it) 418 kb, 17.02.2011 http://127.0.0.1/bilddata/drehbar/pdf/tvs400/bedien/it/mrl_tvs400_it.pdf Operating instructions and Declaration of conformity (fr) 420 kb, 17.02.2011 http://127.0.0.1/bilddata/drehbar/pdf/tvs400/bedien/fr/mrl_tvs400_fr.pdf Operating instructions and Declaration of conformity (es) 420 kb, 17.02.2011 http://127.0.0.1/bilddata/drehbar/pdf/tvs400/bedien/es/mrl_tvs400_es.pdf Operating instructions and Declaration of conformity (nl) 419 kb, 17.02.2011 http://127.0.0.1/bilddata/drehbar/pdf/tvs400/bedien/nl/mrl_tvs400_nl.pdf Operating instructions and Declaration of conformity (de) 415 kb, 15.02.2011 http://127.0.0.1/bilddata/drehbar/pdf/tvs400/bedien/de/mrl_tvs400_de.pdf Operating instructions and Declaration of conformity (en) 417 kb, 17.02.2011 http://127.0.0.1/bilddata/drehbar/pdf/tvs400/bedien/en/mrl_tvs400_en.pdf BG-test certificate (de) 267 kb, 07.11.2005 http://127.0.0.1/bilddata/drehbar/pdf/tvs400/baumuste/z_tv4p01.pdf CCC certification (en) 577 kb, 12.12.2006 http://127.0.0.1/bilddata/drehbar/pdf/tv335_55/zertifikat/q_349p02.pdf CCC certification (cn) 609 kb, 12.12.2006 http://127.0.0.1/bilddata/drehbar/pdf/tv335_55/zertifikat/q_349p03.pdf Images Dimensional drawing (basic component)

Dimensional drawing (basic component) K.A. Schmersal GmbH, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 21.04.2011-16:21:01h Kasbase 1.4.7 DBI