PILOT SERIES MPT700TS

Similar documents
Microprocessor Based Wye-Delta Reduced Current Type Starting

Soft Start Series MP700 Solid State, Reduced Voltage

Across-the-Line SERIES MP300 Combined Manual and Automatic

Variable Frequency Drive SERIES MP800 VFD

MPT Electric Fire Pump Controller

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Drawing Submittal Package

MPT Electric Fire Pump Controller

Drawing Submittal Package

LMR Electric Fire Pump Controllers Features

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

FDF Foam Pump Controllers Features

Transfer Switch Features

Technical Data Submittal Document

LMR Electric Fire Pump Controllers Features

Fire Pump Controller. For Electric Motor Driven Fire Pumps. Wye Delta Reduced Current Types

FT60 Reduced Voltage - Autotransformer

Customer Connection Terminals Connection terminals for external customer connections, are located at the top of the Power I/O board.

DIESEL Engine Fire Pump Controllers Features

FD30 Full Voltage - Across the Line July 2011

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Transfer Switch Features

Fire Pump Controllers Medium Voltage Controllers

MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS

FT40 Reduced Voltage - Part Winding. Electrically and Mechanically

FT20 Full Voltage - Limited Service. Electrically and Mechanically

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Powerohm Resistors Digital HRG System

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

FTA550 JOCKEY PUMP CONTROLLERS

Guide Specification Model CTG Automatic Transfer Switch

Fire Pump Controllers Foam (Additive) Controllers

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

DIESEL Engine Fire Pump Controllers Features

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

Technical Data Submittal Documents

AS950 REFRIGERATED SAMPLERS

MANUAL FOR MODEL FD4 FIRE PUMP CONTROLLERS

CAREL heatersteam Electric Element Steam Humidifiers

FDJ SERIES Jockey Pump Controllers Features

DGC-1000 DIGITAL GENSET CONTROLLER

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

DGC-500 DIGITAL GENSET CONTROLLER

CONTENTS AUTOMATIC TRANSFER SWITCHES

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

SECTION FIRE PUMP AND CONTROLS

Specification/ Data Sheet

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

SECTION Fire Pumps

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

METRON FIRE PUMP CONTROLS

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

SECTION PACKAGED HEAT TRANSFER SYSTEM

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES

PARAGON Commercial Refrigeration Controls

RELEASE DEVICE CONTROLS

CommStat 4 Controller

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

EATON LMR Plus Electric Fire Pump Controllers

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

EasyTronic III MANUAL SERVICE

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

70E Pressure Booster. Bell & Gossett. Bulletin D-215D. Efficient Operation. Easy to Select and Install. Quick Set-up through EZ Start

NS (A) ECN

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

ACT2-CS Convenience Store Controller

PART GENERAL 1.01 SECTION INCLUDES

Smart thermostat with Humidification/De-humidification control

Two-Channel Gas Controller

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

600-10,000 scfm AES Series. AES Series Energy Saving. Refrigerated Air Dryer ,000 scfm. Front Page

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO:

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Control Relay Modules

COMMERCIAL WASHERS MODELS T-300/350/400/450/600/650/750/900/950/1200/1450 VENDED C-SERIES CONTROL

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Comfort Control 2 HD Thermostat

MODEL B2 INSTALLATION MANUAL

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Safety & Installation Instructions

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

STR-Series Indirect-Fired Air Turnover Units

Emerson Blue Easy Set 1H/1C

TWLC - Tempered Water Logic Controller. The Intelligent Control

Options for Diesel Fire Pump Controllers

Generator Gas Analyzer (GGA)

CONSTANT PRESSURE CONTROLLER

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Transcription:

Metron Fire Pump Controls and Accessories Microprocessor Based Soft Start/Stop Solid State Reduced Voltage NEW PRODUCT PILOT SERIES MPT700TS ONLY 32 WIDE WITH ATS Available in Across-The-Line, Soft Start, Wye-Delta Open & Closed Transition Starting Methods For Select Models, HP and Voltage Ranges Only MPT700TS Soft Start Fire Pump Controllers with Automatic Transfer Switch utilize a solid state motor controller. The motor voltage is raised to an adjustable initial torque value. The motor voltage is gradually increased during the acceleration ramp time, max. of 10 seconds per NFPA 20. After a minimum run time and all starting causes have returned to normal, the controller will initiate a ramp down process by smoothly decelerating the motor at an adjustable rate to a stop. This smooth acceleration/deceleration of the motor reduces surges and water hammer in the sprinkler system. In-rush current can be adjusted as low as 25%. Metron s new patented fire pump controller with integral transfer switch is designed in a single narrow enclosure to reduce the amount of pump room space required. PATENTED DESIGN AND TECHNOLOGY Only the highest quality components, UL Listed or Recognized, are used throughout to assure the best possible reliability. The cabinet is fabricated of heavy 12 gauge reinforced steel, with Type 3R supplied as standard and rated 40 C standard, 50ºC optional. All field wiring and service connections may be made from the front, allowing the controller to be mounted flush against a wall. Metron fire pump controllers conform to the latest requirements of the NFPA 20, UL 218 and FM 1321/1323, and bear the labels of MPT700TS 0218 UL218 FM1321/1323 MEMBERS

Metron Fire Pump Controls and Accessories Touch Screen Features Large 7 color LCD touch screen Simultaneous display on Home screen for 3 phase amperage/voltage, System pressure, Start Pressure, Stop pressure, System status, Alarm status, Transfer switch position, date and Time On-screen Icons for Pilot/Quick Start, System Set Points, User Settings, Data Log, Diagnostics, and others for ease of installation and data log/event history retrieval. Let Metron s Pilot feature guide you through the controllers startup settings. The Pilot feature guides the user automatically step-by-step through the settings required at start up. Searching through multiple menus to locate settings is eliminated. Pilot appears on the touch screen on initial power up, or by pressing the Pilot Icon. View data log/event history in Calendar screen to easily find a specific event by touching the day on the calendar month Multi level password protection Rated 40 C standard, 50 C optional with Type 3R enclosure as standard For added safety a through door USB port is provided to access data logs/event history without opening the controller door. Internal controller temperature monitored and data logged as standard Status LED s on PB board inputs/outputs provide visual indication of on/off status Pressure transducer fault LED System Self Test on power up Serial communication to PC boards reduces number of wire for improved reliability. Single logic control for operation of both the fire pump controller and transfer witch. Monitoring of the PC board inputs/outputs through the touch screen Monitor normal and emergency power sources simultaneously Phase rotation selectable through Pilot feature or Congif Icon Foreign language selectable Modbus communication Protocol via RS785 port Controllers are suitable for use as Service entrance equipment 600 PSI rating provided as standard. Utilizes a manifold block for the pressure transducer and drain solenoid valve that eliminates the need for copper plumbing with Teflon tape, significantly reducing the possibility of water leaks. Standard Features The Microprocessor based logic with real time/date clock capable of running 7+ years without AC power. Includes low battery indicator. The on-board data log memory can store up to 18 months of event history (approx. 112,000 events), and over 10 years of event history with a 2G USB Flash Drive. Data/Event log can store over 10+ years of time and date stamped events. Real time clock is accurate to plus/minus 2 minutes per year over the full temperature range. The event history can be viewed by scrolling on the display or by saving it to a USB flash drive. The event history is recorded as a.csv file and can be easily opened as an Excel file. MTS Automatic Transfer Switch Features The combination fire pump controller/automatic transfer switch is Listed with Underwriters Laboratories to UL 1008, Approved by Factory Mutual, and meets the latest requirements of NFPA 20. The transfer switch is a mechanically held double throw switch with a fast acting drive mechanism. The Metron MTS automatic transfer switch control functions are an integrated into the fire pump controllers main microprocessor control, eliminating the need for a separate transfer switch controller, reducing the number of components and wiring for improved reliability. Continues on next page... MPT700TS 0218 www.hubbell.com/metron/en

Metron Fire Pump Controls and Accessories Functions include transfer, retransfer and generator start adjustable time delays, generator start contacts, 3 phase voltage monitoring and frequency monitoring on Normal and Emergency power sources. Auxiliary Programs The controller includes as standard six (6) discrete auxiliary inputs and six (6) outputs. These auxiliary I/O are in addition to those required by NFPA 20 UL and FM. All auxiliary I/O can be field programmed on the touch screen. Expandable 12 channel I/O board for additional alarms, expandable to 168 I/O. All 48 aux programs can have a custom message. Events and Alarms Event Messages EVENT MESSAGES REMOTE TEST START MANUAL TEST START AUTO TEST START MODBUS TEST START REMOTE START MODBUS START HIGH ZONE CALL TO START DELUGE START PRESSURE TRANSDUCER FAILURE START SUPERVISORY POWER FAILURE START LOW PRESSURE START LOCAL START PUMP RUNNING CRR ENERGIZED/DE- ENERGIZED CSR ENGERGIZED/DE- ENERGIZED LOAD SHED SOFT START ON MANUAL STOP AUTO STOP ACCELERATION TIMER ON REMOTE LOCKOUT REMOTE LOCKOUT CLEARED DUMP VALVE OPENED DUMP VALVE CLOSED DUMP VALVE INSUFFICIENT DISCHARGE SYSTEM REBOOT Each record tracks: Date and Time Pressure Voltage and current for connected source Login state Pressure Internal temperature State of every alarm Which source the transfer switch is connected to. Whether normal/emergency power is available. The I/O state of all PCB's (excluding any add-on boards). Active start conditions. The state of all aux programs (48 aux programs available). Power available Alarm Messages Each alarm occurred or cleared PHASE FAILURE (NORMAL & EMERGENCY) PHASE REVERSAL (NORMAL & EMERGENCY) PHASE OVER/UNDER VOLTAGE (NORMAL & EMERGENCY) PHASE OVER/UNDER FREQUENCY (NORMAL & EMERGENCY) PRESSURE TRANSDUCER FAULT LOW/HIGH PRESSURE FAIL TO START FAIL TO STOP LOCKED ROTOR MOTOR OVERLOAD LOW SUCTION LOW ZONE FAIL TO START LOW ZONE QUIT SUPERVISORY POWER FAILURE GENSET FAIL TO START LOSS OF NORMAL POWER MPT700 -- Model Type *Options are listed on next page. Model Number Designation - xxx -- Horsepower Rating: 5-600 - XXX -- Voltage Rating: 200-480 VAC - B or C -- Example: MPT700-75-480C-H MTS Withstand Rating: B - 22,000 (@575 VAC) 50,000 (200-480 VAC) C - 100,000 (200-480 VAC) X -- *Option Designation(s) MTS -- With Transfer Switch Standard Withstand Ratings VOLTS 200-208 220-240 380-415 460-480 200-208 220-240 380-415 460-480 HP -- RMS SYMMETRICAL 15-150 -- 100kA 15-200 -- 100kA 15-300 -- 100kA 15-400 -- 100kA 200-250 -- 50kA 250-300 -- 50kA 350-350 -- 50kA 500-600 -- 50kA Information required with order: 1) Model Type 2) Motor Horsepower 3) Line Voltage, phase and frequency 4) Options, if any MPT700TS 0218 www.hubbell.com/metron/en

Metron Fire Pump Controls and Accessories Options Option H: Space Heater If the ambient atmosphere is especially damp, a space heater rated at 100 watts may be supplied to reduce moisture in the cabinet. A thermostat is supplied as standard with this option. A humidistat may be substituted if specified. Enclosure Options Type 3R is standard. The following UL Type enclosures are available: Type 4 Type 4X (painted cold roll steel) Type 4X (304 or 316 Stainless Steel) Type 12 Consult factory for additional options. US PATENTS US 7,762,786 B2 Integrated Fire Pump Controller and Automatic Transfer Switch vertical arrangement in a single enclosure. US 8,482,307 B2 Method For Prevention of Untested PC Boards from Being Used In A Fire Pump Control System. Contact Us NORTH & SOUTH AMERICA Hubbell Industrial Controls, Inc. Metron Fire Pump Control Division 4301 Cheyenne Dr., Archdale, NC 27263 Phone: 336-434-2800, Fax: 336-434-2801 salesmail@metroninc.com www.hubbell-icd.com EUROPE Metron Eledyne 18 Autumn Park, Dysart Road Grantham, Lincolnshire, NG31 7DD, United Kingdom Tel:+44 (0) 1476 516120, Fax:+44 (0) 1476 516121 info@metroneledyne.co.uk TAIWAN Hubbell-Taian Co. Ltd. Contact Person: Jimmy Wu Tel: (02)2522 1862 ext.10, Fax: (02)2522 1872 6th Floor, 156-1, Sung Chiang Road, Taipei, Taiwan jwu@hubbell-taian.com.tw CHINA Hubbell-Anmex (Shanghai) Trading Co., Ltd Contact Person: Derek Chen 6H, Zhao-Feng Universe Building, No. 1800, West Zhongshan Rd., Shanghai 200235, China Tel: 86-21-64400151, 64400156, Fax: 86-21-64400152 Mp: 86-13391373007 dchen@hubbell-anmex.com.cn PHILIPPINES Hubbell-Taian Co. Ltd. Philippine Representative Office Contact Person: Wency Villas-Besa Unit 23 Parc House Bldg, #227 EDSA, Greenhills, Mandaluyong City 1556, Philippines Tel: 632-6556460, Fax: 632-6556421 DL WL: 632-8717389 wency@hubbelltaian.com.ph www.hubbell.com/metron/en Hubbell Industrial Controls, Inc. 4301 Cheyenne Dr., Archdale, NC 27263 PH: 336-434-2800 FAX: 336-434-2809 Email: salesmail@metroninc.com MPT700TS 0218 Hubbell Incorporated. All rights reserved. Specifications subject to change without notice. Printed in USA.

4 DIMENSIONS & DATA ELECTRIC FIRE PUMP WITH TRANSFER SWTICH 3 FM APPROVED 2 MPT450TS, MPT700TS 1 16.00 [406.4] TOUCH SCREEN DIGITAL DISPLAY NORMAL SOURCE ISO/CB SWITCHES HANDLE EMERGENCY SOURCE ISO/CB SWITCHES HANDLE B B ALARM HORN USB PORT 71.08 [1805.3] LOCKING DOOR HANDLES EMERGENCY START HANDLE 8.00 [203.2] 2.50 2 HOLES FOR PIPE ENTRANCE TYP. ALL LEGS CONTROLLER MTS 14.00 [355.6] 6.00 [152.4] 52.33 [1329.2] SIDE VIEW FRONT VIEW INLET 1/2" NPT FEMALE WATER CONNECTIONS 1.50 [38.1] * SEE DETAIL "A" RECOMMENDED CONDUIT ENTRANCE (BOTTOM ONLY) 6.88 [174.8] 10.10 [256.5] 6.88 [174.8] 16.00 [406.4] OUTLET DETAIL A PLUMBING MOUNTING HOLES 8.74 [221.9] 3.40 [86.3] A 15.54 [394.7] 32.18 [817.4] 20.24 [514.1] 11.00 [279.4] 5.90 [149.9] A VOLTAGES 200V 208V 230-240V 380-415V 440-480V HORSEPOWERS MPT450TS MPT700TS 25-60 - 25-75 75 30-75 75 50-125 125 60-150 - ENCLOSURE TYPES TYPE 3R CRS (STD) SHOWN TYPE 4 CRS TYPE 4X CRS TYPE 304 SS (PAINTED) TYPE 304 SS UNPAINTED TYPE 316 SS PAINTED TYPE 316 SS UNPAINTED BOTTOM VIEW SELECTION TABLE (CHOOSE FROM TABLES ON LEFT) A NOTES: ENCLOSURE MADE FROM 16GA. STEEL WITH RED POLYESTER POWDER FINISH. ENTER CABLE(S) FROM TOP OR BOTTOM (PREFERRED) PROTECT INTERNAL EQUIPMENT FROM DRILLING CHIPS DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE. ALWAYS CONSULT FACTORY TO CONFIRM CURRENT INFORMATION. TYPE 3R SHOWN. ALL DIMENSIONS IN INCHES. ALL DMENSIONS ARE SAME FOR 3R, 12, 4 AND 4X ENCLOSURE TYPES. POWER AVAILABLE AND PUMP RUNNING LIGHTS ARE STANDARD 4 3 DATE: CONTROLLER WITH MTS (METRON TRANSFER SWITCH) 1/2017 G:\DWG\DEPARTMENT_1\FirePump-Electric_Controller\MPT Submittal Info\MPT Inventor Drawings\MPTD33980.idw CONTROLLER TYPE HP VOLTAGE ENCLOSURE TYPE MPT450 MPT700 DRAWN BY: METRON Division of - Hubbell ICD, Inc. 4301 Cheyenne Drive Archdale, N.C. 27263 2 S. JUDD RATING: REV. N/A DRAWING NO. MPTD33980 1