AQUACIAT. Inverter Heat pump USE RANGE GRAND INVERTER

Similar documents
High temperature air-to-water heat pumps

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

DYNACIAT POWER. High energy efficiency Compact and quiet

High temperature air-to-water heat pumps

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

Compact and silent Scroll compressors All-season operation

DYNACIAT ILG. Use. Description. Heat pumps

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Aquaciat Free cooling

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

AQUACIAT2 HYBRID. Natural GAS condensation boiler Self-adjusting electronic control. Use. Range. Heat pumps and gas boilers

CLIMACIAT AIR COMPACT

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Precision air handling cabinets Ciatronic MICRO/EXPAIR

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Advance Split

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Vertical self-contained air conditioner

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE


HT V2 HT Split

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

Centrifugal air heaters hot water or electrical supply

Process glycol chillers

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Air Cooled Chillers & Heat Pumps WinPACK HE-A

Roof top SPACE RPC 450Z R407C M011

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Galletti Water chillers and heat pumps catalogue

Conditioning your ambient, maximising your comfort.

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Neosys Product catalogue

H4T R410A. refrigerant

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

HYDRONIC RESIDENTIAL

1

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

Water chillers water/water type SIGMA Technical information manual

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

SyScroll 40 to 75 Air NEW

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

PRODUCT GUIDE

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Application guide NEOSYS kw. Air cooled liquid chiller Heat pump NEOSYS-AGU-0610-E

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only.

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Aquaflair TRAC-TRAF-TRAH

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

Blue Box Epsilon Echos +

Roof top SPACE RPC 315Z R407C MA00

Precision air-handling cabinets. CIATRONIC System Ultimate precision air-conditioning NA C

Transcription:

High energy efficiency with the R410A Compact and silent Scroll compressors Inverter technology High performance brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 40 to 80 kw Heating capacity: 45 to 90 kw Cooling and heating Hydraulic module Heat recovery ENVIRNMENTALLY HFC R410A PRTECTIN DE FRIENDLY L'ENVIRNNEMENT USE The IVDC series packaged water chillers or heaters are medium-capacity units specifically designed for heating and air conditioning applications in ffices, Healthcare, Administrations, Shopping Centres and the Residential sector. These standard packaged units are designed for outdoor installation and require no special protection against adverse weather conditions. To operate in HEATING or CLING mode, they use the outdoor air as the only external source; this permits the evacuation of heat in summer or the supply of thermal energy for heating in winter. Connected to an underfloor heating or cooling system, fan coil units or an air handling unit, the reversible GRAND INVERTER IVDC series is an extremely easy way to heat and air condition buildings. Each unit is delivered fully assembled, wired (control and power), charged with refrigerant and factory tested. Simply make the necessary electrical and hydraulic connections, and your unit is ready to operate. RANGE IVDC series Reversible Air/Water modules with hydraulic system (circulation pump). AIR CNDITINING - HEATING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 09.639 A 1

DESCRIPTIN Inverter The IVDC series is supplied as standard with the following components: - air-source condenser with axial fan motor inverter and variable speed inverter, - high efficiency brazed-plate heat exchangers, - chilled water or hot water capacity control, - control, automatic operation and startup box:. Electrical supply: Three-phase 50 Hz - 400 V (+6%/-10%) + Earth. Control circuit: Single-phase 50 Hz - 230 V (transformers fitted on unit as standard), - casing for outdoor installation. Complies with European directives (CE): - Machinery directive (98/37/EC) - EMC directive (2004/108 EC) - Pressure equipment directive (97/23/EC, category 2) - Low voltage (2006/95/EC) Compliance with standards - EN 60204, EN 378-2 (NFC 15-100, France) STANDARD AND PTINAL EQUIPMENT Power supply: 400 V, 3-Phase, 50 Hz, without neutral, with transformer Coil protection screen Resilient mounts Main disconnect switch Water flow regulator Phase monitor (reversal, loss, over- and undervoltage) Soft start Variable-speed condenser fan Connection frame/duct (XTRAFAN) Sleeve + connection duct/duct (XTRAFAN) 800 micron water filter All-season operation (-20 C) Remote control Additional voltage-free contacts board LNWRKS Protocol MULTICNNECT multiple unit management Partial heat recovery - desuperheater Frost protection BLYGLD coated coil Polyurethane coated coil fins Hydraulic control kit (manifold, control & shut-off valve) Hydraulic hoses Double pump / 200 300 15 kw electric auxiliary heater kit 150 15-30 - 45-60 kw electric auxiliary heater module kit / 200 300 External auxiliary heating management (4-stage) IVDC : Supplied as standard : ption Note: Some technical options not listed above may be added on special request (please contact us). 4 AIR CNDITINING - HEATING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 09.639 A

TECHNICAL DATA - REVERSIBLE HEAT PUMPS IVDC 150 V 200 V 300 V Cooling capacity 1 kw 36.9 47.4 Power input kw 13.7 18 Energy efficiency rating (EER) 2 2.69 2.63 Seasonal energy efficiency rating (ESEER) 3.97 3.87 Lw/Lp 3 (HP high performance version) db(a) 78.5/46.5 75.9/43.9 Underway Lw/Lp 3 (high temperature [HT] version) db(a) 86.3/54.3 86.3/54.3 Heating output 1 kw 41.1 53.5 Absorbed power kw 13.8 16.7 CP/CP performances 2 2.98 3.20 Compressor Inverter hermetic SCRLL Start-up mode Direct using Soft Starter Number 1 Power control % Variable from 33 to 100% Refrigerant oil type Polyester PE 160 SZ il capacity l 3 3.3 6.7 No. of refrigerant circuits 1 Refrigerant (GWP) kw eq. C2 R410A (1720) Refrigerant load kg 12 17 Underway Electrical supply ph/hz/v Three-phase 50 Hz 400 V (+6%/-10%) + Earth Machine protection rating IP 44 Control circuit voltage ph/hz/v Single-phase 50 Hz 230 V (+6%/-10%) - transformer fitted Evaporator Brazed plate exchanger(s) Water capacity l 3.11 7.71 8.6 Chilled water outlet temp. (min./max.) C -10 / +15 Hot water outlet temp. (min./max.) C +30 / +55 Minimum water flow rate m 3 /h 5.1 6.9 10.4 Maximum water flow rate m 3 /h 13.1 17.6 24.5 Water connections 1 1/2 M 2 M 2 M Max. pressure, water end bar IVDC 4 bar Air-cooled condenser Finned heat exchanger Fan mm 800 HP High Performance Version- No. x motor capacity no. x kw 1 x 1.143 1 x 1.066 1 x 2.153 HP High Performance Version - Air flow rate m 3 /h 15,500 16,100 24,000 HP High Performance Version - Rotational speed rpm 690 690 1049 HT High Temperature Version- No. x motor capacity no. x kw 1 x 2.443 1 x 2.443 1 x 2.553 HT High Temperature Version - Air flow rate m 3 /h 23,000 23,500 26,000 HT High Temperature version - Rotational speed rpm 985 985 1110 Min. water volume (IVDC) l 74 96 144 Expansion vessel C l 6 12 12 Maximum capacity of system in litres 4 Pure water Maximum capacity of system in litres 4 Glycol/water mix max. water 36 C 5 550 1100 max. water 46 C 5 325 650 max. water 36 C 5 390 780 max. water 46 C 5 230 460 Standard pump Qty. 45 40 41 Height (excluding mounts) mm 1423 1773 1773 Length (IVDC) mm 1995 Depth mm 1055 Weight (empty) kg 450 620 750 Storage temperature C +50 C ➀ HP High Performance version capacities based on: a/ CLING: +12 C/+7 C and condenser air inlet temperature of +35 C at nominal air flow b/ HEATING: hot water outlet at +45 C and external air at +7 C DB, 86% RH (EN 14511 and EURVENT conditions) ➁ Gross EER/CP values ➂ verall sound power level (Lw) overall sound pressure level (Lp) measured at 10 metres in a free field, as per IS 3744 4 System capacity depending on expansion vessel fitted on unit 5 Water temperatures given are those which can be reached when the machine is off AIR CNDITINING - HEATING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 09.639 A 5

DIMENSINS Inverter IVDC model 150 135 50 974 x 957 (int) connection sleeve (option) Connection frame (option) 2070 819 1055 1995 148 4 removable lifting lugs 20.5 holes 1157 E 192 120 x 4 1423 Xtrafan 120 1321 6 5 2 1 Wooden handling blocks, to be removed after fitting C D B D A 548 1045 1145 527 840 1984 Leave a space of 1 metre around the unit for maintenance utdoor air discharge utdoor air intake 5: G 1/2 male hot water inlet 6: G 1/2 male hot water outlet 1: G 1 1/2 male chilled water inlet 2: G 1 1/2 male chilled water outlet E: Electrical supply ( 80) Position of mounts Anti-vibration mounts Weight (kg) A B C D empty in operation IVDC 150 300 1147 300 P25 50 x 120 450 454 24 AIR CNDITINING - HEATING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 09.639 A

DIMENSINS Inverter IVDC models 200 to 300 819 1055 135 50 974 x 957 (int) connection sleeve (option) Connection frame (option) 2070 1995 113 203 423 120 x 3 1773 Xtrafan 1671 5 6 1 2 4 removable lifting lugs 20.5 holes C E B E 1145 D A 120 548 Wooden handling blocks, to be removed after fitting 1044 527 900 1988 Leave a space of 1 metre around the unit for maintenance utdoor air discharge utdoor air intake 5: G1 male hot water inlet 6: G1 male hot water outlet 1: G 2 male chilled water inlet 2: G 2 male chilled water outlet E: Electrical supply ( 80) Position of mounts Anti-vibration mounts Weight (kg) A B C D E empty in operation 200 100 1188 350 P25 50 x 200 P25 50 x 150 620 625 IVDC 300 100 1088 400 P25 50 x 200 P25 50 x 200 750 755 AIR CNDITINING - HEATING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 09.639 A 25

EXAMPLES F HYDRAULIC CNNECTIN DIAGRAMS Chilled water - hot water hydraulic circuit pe c a psl s m e r p p s v3v b FS vr rb FS r t v Hot water circuit during partial recovery (desuperheater) Energy recovery Direct domestic hot water production s m e a 50 C 60 C v3v 55 C 52 C DHW loop FS ds 50 C min. v3v Cold water Chilled water - hot water circuit Desuperheater option Aquaciat : air-to-water reversible unit psl : zero pump water pressure switch 3wv : three-way valve 2wv : two-way valve e : expansion vessel v : retaining valve g : gauge a : water top-up b : mixer tank sv : shut-off valve cv s cp t rb FS ds sv : control valve : safety valve : circulation pump : temperature sensor pocket : backup heater : water flow regulator : desuperheater : solenoid valve General comments: p : air vents at pipe high points d : drain nozzles at pipe low points N.B.: these circuit diagrams are provided for information only and must not be construed as detailed execution diagrams. 26 AIR CNDITINING - HEATING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 09.639 A

FIXING F FRAMES T GRUND IVDC The chassis may be affixed to the ground. (mounts with bolts NT supplied by CIAT). (The hardness is defined by the unit's weight and centre of gravity). Electrical box side Finned coil side Top view of chassis Hydraulic module side (version H) 150 V 200 V 300 V L1 316 L2 316 L3 1984 1987 L4 1045 1044 Installation recommendations Water quality criteria to be respected Important: it is essential that an 800 micron water filter be placed on the unit's water inlet during installation. The quality of the water used has a direct impact on the correct operation of the unit and its service life. This is particularly true if the water used clogs or corrodes components or promotes the growth of algae or microorganisms. The water must be tested to determine whether it is suitable for the unit and whether chemical treatment will suffice to make it of acceptable quality and if a water softening/demineralising system should be installed. The results of the analysis must confirm whether the site's water is compatible with the various materials used on the CIAT unit's circuit: - 99.9% copper tubes brazed with copper and silver, - threaded bronze couplings or flat steel flanges, depending on the unit model, - plate heat exchangers and connections made of AISI 316/ DIN 1.4401 stainless steel brazed with copper and silver. N.B.: The guarantee shall be void if these instructions are not followed. Lifting and handling The utmost safety precautions must be taken when lifting and handling the unit. Always follow the lifting diagram on the unit and in the installation, operation, commissioning and maintenance manual. Before attempting to lift the unit, make sure the path leading to its intended location is free from obstacles. Always keep the unit vertical when moving it. Never tip it or lie it on its side. The standard version of the is designed for outdoor installation. Precautions should be taken to protect it from freezing temperatures. Special attention should be paid to ensure sufficient free space (including at the top) to allow maintenance. The unit must be placed on a perfectly level, fireproof surface strong enough to support it once charged. Noise pollution from auxiliary equipment such as pumps should be studied thoroughly. Potential noise transmission routes should be studied, with assistance from an acoustical engineer if necessary, before installing the unit. Flexible couplings must be placed over pipes (available as options). Reversible units installed in areas of snowfall or heavy frost should be raised approx. 300 mm off the floor or ground. n reversible units, the steam and defrosted water must be properly evacuated during defrosting cycles. Installation in a machine room Installation in a machine room, if required, gives rise to special technical precautions, such as: - the draining of defrosted water, including during periods of very low outdoor temperatures, - the management of water vapour created at the fan discharge during defrosting - ground which can support the weight of the unit and which must be perfectly watertight and capable of collecting and draining the defrosted water, including during freezing periods, - the weight of an air discharge sleeve must not be supported by the roof of the unit, under any circumstances. According to the regulations in force where the installation is taking place, installation within a machine room may have to comply with certain ventilation rules for fresh air to ensure there is no risk of discomfort or any hazard in the event of a refrigerant leak. Choosing a location for the unit AIR CNDITINING - HEATING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 09.639 A 27

Assembly of separately supplied accessories: A number of optional accessories may be delivered separately and installed on the unit at its location. Always follow the instructions in the installation, operation, commissioning and maintenance manual Electrical connections: Always follow the instructions in the installation, operation, commissioning and maintenance manual. All information concerning electrical connections is stated on the wiring diagrams provided with the unit. Always follow this information. Electrical connections must be made in accordance with best current practices and applicable standards and regulations. Electrical connections to be made on site:. unit's electrical supply,. outdoor operation authorisation (optional). information feedback (option) It should be noted that the unit's electrical system is not protected against lightning strikes. Therefore components to protect against transient voltage surges must be installed on the system and inside the electrical supply unit. Pipe connections: Always follow the instructions in the installation, operation, commissioning and maintenance manual. All pipes must be correctly aligned and slope toward the system's drain valve. Pipes must be installed to allow sufficient access to the panels and fitted with heat insulation. Pipe mountings and clamps must be separate to avoid vibrations and placing pressure on the unit. Water shut-off and control valves must be fitted when the unit is installed. - Pipe connections to be made on site:. system water supply with pressure-reducing valve,. evaporator, condenser and drain, - The following are a few examples of accessories essential to any hydraulic system and which must also be installed:. thermostatically controlled valve on the condenser water outlet to regulate the flow of cooling water (heat pump in HEATING mode).. water expansion vessel,. drain nozzles at pipe low points,. exchanger shut-off valves equipped with filters,. air vents at pipe high points,. check the system's water capacity (install a buffer water tank if necessary),. flexible couplings on exchanger inlets and outlets,. manual water flow rate control valves,. thermometers on each water inlet and outlet to allow all the necessary checks during start-up and maintenance. N.B.: - Pressure in the water circuits below 4 bar. - Place the expansion vessel before the pump. - Do not place any valves on the expansion vessel. - Make sure the water circulation pumps are placed directly at the exchanger inlets. - Make sure the pressure of the water drawn in by the circulation pumps is greater than or equal to the required minimum NPSH, particularly if the water circuits are open. - Test the water quality in accordance with the relevant technical requirements. - Take the necessary precautions to protect the unit and hydraulic system from freezing temperatures (eg. allow for the possibility of draining the unit). If glycol is added to prevent freezing, check its type and concentration before commissioning. - Before making any final hydraulic connections, flush the pipes with clean water to remove any debris. Commissioning units must be commissioned by CIAT or a CIAT-approved contractor. IMPRTANT: Following commissioning and every time the compressor has been switched off for a prolonged period (except during operating cycles), the unit must be switched on for 12 hours before start-up to ensure the compressor oil is correctly preheated. Always follow the instructions in the installation, operation, commissioning and maintenance manual. Partial list of precommissioning checks: - Correct positioning of unit, - Power supply protections, - Phases and direction of rotation, - Wiring connections on unit, - Direction of water flow in unit, - Cleanliness of water circuit, - Adjusting water flow rate to specified value, - Pressure in the refrigeration circuit, - Direction of rotation of compressors, - Water pressure drops and flow rates, - perating readings. Maintenance operations Specific preventive maintenance operations must be regularly carried out on the unit by CIAT-approved firms. The operating parameters are read and noted on a "CHECK LIST" form to be returned to CIAT. It is essential to comply with the Instructions, Installation, peration, Commissioning and Maintenance Manual. You must take out a maintenance contract with a CIATapproved refrigeration equipment specialist. Such a contract is required even during the warranty period. 28 AIR CNDITINING - HEATING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 09.639 A

CNNECT CNTRL USER-FRIENDLY INTERFACE CNSLE - Multilingual LCD display (2 lines of 20 characters) - Display of pressure and temperature values- Management of the pumps - Communication Voltage-free contacts available: Inputs: - Control of automatic operation - Selection of setpoints 1/2 - Selection of heating/cooling utputs: - Fault signalling contact RS-485 UTPUT AS STANDARD pen Modbus / Jbus protocol (standard) LonWorks protocol (option) RELAY BARD (PTIN) Available outputs: - Water flow fault - Anti-freeze fault - Pump fault - Fan fault - High and low pressure fault - Compressor safety fault - Discharge temperature fault - Compressor running status REMTE-CNTRL UNIT (PTIN) 150 to 300 peration and design same as display console MULTICNNECT MULTI-UNIT MANAGEMENT (PTIN) Main functions available: - Management of up to 8 units on a single water loop - Management in CLING mode (chilled water unit) or in HEATING mode (heat pump) - Management of the chilled water or hot water network pumps - Centralised management of a backup unit - Unit bypass - System time programming - Energy storage mode management - Fault management on each unit - Unit runtime balancing - Integrated Modbus GTC link for obtaining information on unit operation and faults This document is non-contractual.as part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification. Head office Avenue Jean Falconnier - B.P. 14 01350 - Culoz - France Tel.: +33 (0)4 79 42 42 42 - Fax: +33 (0)4 79 42 42 10 info@ciat.fr - www.ciat.com CIAT Service Tel.: +33 (0)4 79 42 42 90 - Fax: +33 (0)4 79 42 42 13 Compagnie Industrielle d Applications Thermiques - S.A. with a registered capital of 26 728 480 - R.C.S. Bourg-en-Bresse B 545 620 114 AIR CNDITINING - HEATING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 09.639 A 29