The Saddle Vent. & Ventilation Kits. Confined Space Entry Do it Right The First Time. Leading The Safety Industry Since 1984

Similar documents
& Ventilation Kits. Confined Space Entry Do it Right The First Time. Leading The Safety Industry Since 1984

SVF-8DC. Manual No. BLWR007 Rev. 3 February 2014

OPERATING MANUAL 12 AXIAL FANS

SVB-E8EXP SVB-A8 SVB-G8 SVB-G8P SVB-E8-2. Manual No. BLWR001 Rev. 7 April 2013

SAFETY PRODUCTS CATALOG

Explosion Proof Ventilation Fan Redirects Stale Air From Hazardous Location Areas

EURAMCO SAFETY S CERTIFIED PRODUCT MARK OF EXCELLENCE

Confined Space Ventilation equipment

, A Product Catalog

NHR-25 Feed Hopper with Agitator

Manufacturer of RAMFAN Portable Ventilators. Fire Rescue Portable Ventilation Solutions for Smoke Removal

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

General Purpose Ventilation Fan - Venturi-Style Blower PSIG

CLIMATE CONTROL PRODUCT GUIDE

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Ultrasonic Point Level Switches

ELECTRONIC FIREPLACE DAMPER

ELECTRONIC FIREPLACE DAMPER

TOYOTA FJ-40 DIRECTIONS

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

fans & heaters SIMPLE, ROBUST AND RELIABLE

SUBMITTAL SCHEDULE & DATA

Ventilators COPPUS CONTACT INFORMATION

TECHNICAL SPECIFICATIONS

MARTIN Insertable Dust Collector

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

IS Series Pressure Sensing Switches

*RENTAL* Explosion Proof Portacool Portable Evaporative Cooler - C1D1 - Water Mist Cooler - 30" OD

DuPont Formacel Z-2. Safety and Handling of DuPont Formacel Z-2: Thermoplastic* Foam Extrusion Applications FOAM EXPANSION AGENT TECHNICAL INFORMATION

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

CONFINED SPACE VENTILATION

1.1 SECTION INCLUDES.1 Materials and installation for aboveground oil storage tanks..2 Section Waste Management and Disposal.

HDLV 55-Gallon Powder Drum Unloader

MODEL: SSAT-2L/6L SK

WFDE Series Waterflow Detector

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

TECHNICAL SPECIFICATIONS

Ultrasonic Switches. Features & Benefits

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

I storm. Circular High Speed Hand Dryer. Model N2 : I storm...,. Patent Pending. Operating Instructions and Parts Manual

TECH REPORT 200: Use of Water Traps and Drying Filter with the FX-5000 Tension System. Document: Water Trap and Drying Filter Tech Report, Rev. 8.

MODEL CDB8 INSTALLATION INSTRUCTIONS

Gerber Innovations M Series Laser. Site Preparation & Installation Manual

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Product Dimensions Page 1 of 7. DA Downdraft Ventilation Hood

U - SMOKE EJECTOR SERIES & ACCESSORIES

OWNER S MANUAL #DC2000Y #DC2000YCF 2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2000Y Global Rd.

IN020 Rev F Page 1 of 8

COPPUS Portable Ventilators

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

OWNER S MANUAL #DC2000B #DC2000BCF

3500 CFM TECHNICAL SPECIFICATIONS MIDWEST VACUPAC BIN VENT AND CONVEYOR TRANSFER POINT DUST CONTROL SYSTEM SERIES MBV 43 F MBV 43 C MBV 37 C MBV 54 F

V * V V V V V-25L-230* V * V *

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Installation Instructions

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

FG7T (C and L Series)

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

DURANGO 12V Heater HF

SAFETY CABINETS & CANS WHEN SAFETY COUNTS

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Explosion Proof Hazardous Location Roof Top A/C Units

Brasch Hazardous Location Unit Heaters

Nexus FS Filtration Installation Guide. September 19, 2011

MODEL NUMBER NOMENCLATURE

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

General Design Practices in Reducing Risk in Grain Handling Facilities

TECHNICAL SPECIFICATIONS

Description. Applications

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

PWC 7000 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model Copyright 2012 Vertex Water Products

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

Technologies for all vacuum F-Series Radial and pressure applications

Safety and Installation Instructions Model 1700

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

EHH SERIES DRAW THROUGH FAN COILS CFM

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

Modular Multi-position Air Handler

Table 1. Serie of Digital Room Thermostats.

IN065 Rev C Page 1 of 8

TECHNICAL SPECIFICATIONS

an ISO 9001:2008 Registered Company ShortPac HEAT/COOL (05000-QUX-A/05000-VUX-A)

Click Here To View Item at

Parts and Instruction Manual EX12 Carpet Extractor

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

C6097A,B Pressure Switches

Electrostatic Hazard Control in Process Industry using Multi Channel Earth Monitor

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

Model 144H. Product Data Sheet , Rev DB February Content

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Transcription:

The Saddle Vent & Ventilation Kits Confined Space Entry Do it Right The First Time The Saddle Vent The Tank Saddle Vent The Conductive Saddle Vent Leading The Safety Industry Since 1984 www.airsystems.com

The Original Saddle Vent Approved for use in Non-Hazardous Environments The Saddle Vent was developed by Air Systems and has been in use around the world for over 25 years to make it easier and safer for workers to enter and exit a confined space. The Saddle Vent takes up only 3 inches in a manhole opening and functions as a fresh air conduit to the workers in the confined space. With the Saddle Vent System in place, continuous ventilation is supplied to the workers by eliminating the need to remove the air duct each time a worker needs to enter or exit a confined space, increasing safety and productivity. The Saddle Vent allows unrestricted entry and exit and improves ambient light in a confined space opening Saddle Vent is the Registered Trademark of Industrial Saddle Vent Model: 8" 12" Length: 43.5 51" Width: 14.5 21" Depth: 3.5 5.5" Top O.D.: 8 12" Bottom O.D.: 8 12" Flow Loss: Less than 1% Construction: Polyethylene Temperature Rating: +220 F Melt Temp. -158 F Brittleness Temp. Universal Mount SV-UM Industrial Saddle Vent SV-189 8 Industrial Saddle Vent - orange SV-18912-O 12 Industrial Saddle Vent - orange SV-90 90 elbow - orange. Fits 8 Saddle Vent SV-UM Universal Saddle Vent mounting bracket - steel Standard Ducting SVH-3 8 Diameter duct, 3 foot - yellow SVH-6 8 Diameter duct, 6 foot - yellow SVH-15 8 Diameter duct, 15 foot - yellow SVH-25 8 Diameter duct, 25 foot - yellow SVH-1215 12 Diameter duct, 15 foot - yellow SVH-1225 12 Diameter duct, 25 foot - yellow 90 Elbow SV-90 Standard Ducting

The Conductive Saddle Vent System Saddle Vent Safety Improvements The original Saddle Vent was constructed of standard polyethylene which carries the potential of static electricity build-up on its surface. Static electricity is a source of ignition for fire and explosions. Air Systems developed and patented an improved Saddle Vent System to safely remove potential static electricity charges from the ventilation system. The conductive Saddle Vent System is unique in the fact that it can be field tested for conductivity to ensure static charges are being safely removed from the longest piece of duct to the electric ground on the explosion-proof fan or blower. Approved for use in Hazardous Environments The fully conductive Saddle Vent removes static electricity from the entire ventilation system when installed properly. The Conductive Saddle Vent System is supplied with all of our explosion-proof & pneumatic ventilation kits or it can be purchased separately to upgrade your current ventilation procedures. Patents: The Conductive 8 Saddle Vent SV-189CND 8 Conductive Saddle Vent - black SV-18912-B 12 Conductive Saddle Vent - black SV-90CND Conductive 90 elbow - black. Fits 8 Saddle Vent SV-UM Universal Saddle Vent mounting bracket - steel For Hazardous Locations 8 Conductive Ducting Conductive Ducting With Ground Wires Attached to Each End of Wire Helix SVH-CND86 8 Diameter conductive duct, 6 foot - black SVH-CND815 8 Diameter conductive duct, 15 foot - black SVH-CND825 8 Diameter conductive duct,, 25 foot - black SVHCND1215 12 Diameter conductive duct,, 15 foot - black SVHCND1225 12 Diameter conductive duct, 25 foot - black For Hazardous Locations United States Patents #6,843,274 #7,467,645 #7,992,593 B2 Canadian Patents #2,561,299 #2,436,809 China Patent ZL200480017833.3 Hong Kong Patent HK1094023 European Patents #1491695 Australian Patent 2004 202394 Saddle Vent is the Registered Trademark of Equipment Designed for Hazardous Locations For Use In Hazardous Locations 90 Conductive Elbow SV-90CND Conductive Saddle Vent For work in hazardous locations, read and follow recommended work procedures found in ANSI/API 2015 and 2016 prior to entering a tank or confined space. Conductive Ducting Model: 8" 12" Length: 43.5 51" Width: 14.5 21" Depth: 3.5 5.5" Top O.D.: 8 12" Bottom O.D.: 8 12" Flow Loss: Less than 1% Construction: Polyethylene Temperature Rating: +220 F Melt Temp. -158 F Brittleness Temp.

8 Saddle Vent Ventilation Kits Centrifugal Economy Centrifugal Electric Blower Kit SVB-E8CUP SVB-E8EC blower, 8 Saddle Vent, 90 elbow, 15 foot & 6 foot duct, duct canister & universal mount SV-CUP Saddle Vent Kit Only 8 Saddle Vent and elbow, 6 and 15 foot duct, duct canister, and universal mount Centrifugal Standard Centrifugal Electric Blower Kit SVB-E8SCUP SVB-E8 blower, 8 Saddle Vent, 90 elbow, 15 foot duct, 6 foot duct, duct canister & universal mount 2 Speed Centrifugal Electric Blower Kit SVB-E82CUP SVB-E8-2 blower, 8 Saddle Vent, 90 elbow, 15 foot duct, 6 foot duct, duct canister & universal mount Gasoline Centrifugal Blower Kit SVB-G8CUP SVB-G8 blower, Industrial Saddle Vent, 90 elbow, 15 foot & 6 foot duct, duct canister & universal mount Kits also available with Honda Engine (SVB-G8-H) Steel Axial Steel Axial Saddle Vent Ventilation Kits SVF-8ACUP SVF-8DCUP SVF-8AC fan, 8 Saddle Vent, 90 elbow, 15 foot duct, 6 foot duct, duct canister & universal mount SVF-8DC fan, 8 Saddle Vent, 90 elbow, 15 foot duct, 6 foot duct, duct canister & universal mount Inline Axial 10 In-Line Axial Standard Electric Fan Kit SVB-10ECUP SVF-10E fan, 8 Saddle Vent, 90 elbow, 15 foot duct, 6 foot duct, duct canister & universal mount Axial Economy Axial Ventilation Kits CVF8A15KIT CVF-8AC axial fan, 8 Saddle Vent, 90 elbow, 15 foot duct,6 foot duct, duct canister & universal mount CVF8A25KIT CVF-8AC axial fan, 8 Saddle Vent, 90 elbow, 25 foot duct, 6 foot duct, duct canister & universal mount CVF8D15KIT CVF-8DC axial fan, 8 Saddle Vent, 90 elbow, 15 foot duct,6 foot duct, duct canister & universal mount CVF8D25KIT CVF-8DC axial fan, 8 Saddle Vent, 90 elbow, 25 foot duct,6 foot duct, duct canister & universal mount International Fans with 220 VAC, 50 Hz available. Contact Customer Service for details

8 Conductive Saddle Vent Ventilation Kits For Hazardous Locations Centrifugal Explosion-Proof Centrifugal Electric Blower Kit SVB-E8XCUP SVB-E8EXP blower, conductive 8 Saddle Vent and 90 elbow, 6 and 15 foot conductive duct, duct canister, and universal mount Plug Not Included - See Full Line Catalog for ordering information Equipment Designed for Hazardous Locations For Use In Hazardous Locations Conductive Saddle Vent Kit Only SV-CUPCND Conductive 8 Saddle Vent and 90 elbow, 6 and 15 foot conductive duct, duct canister, and universal mount Pneumatic Pneumatic Centrifugal Blower Kit SVB-A8CUP SVB-A8 blower, conductive 8 Saddle Vent and 90 elbow, 6 and 15 foot conductive duct, duct canister, and universal mount Intrinsically Safe Operation Inline Axial 10 In-Line Axial Explosion-Proof Fan Kit SVF10EXCUP SVF-10EXP fan, conductive 8 Saddle Vent and 90 elbow, 6 and 15 foot conductive duct, duct canister, and universal mount Plug Not Included - See Full Line Catalog for ordering information Axial Equipment Designed for Hazardous Locations For Use In Hazardous Locations Conductive Economy Saddle Vent Ventilation Kits CVFEX15KIT CVF-8EXP Fan, conductive 8 Saddle Vent and 90 elbow, 6 and 15 foot conductive duct, duct canister, and universal mount CVFEX25KIT Includes CVF-8EXP Fan, conductive 8 Saddle Vent and 90 elbow, 6 and 25 foot conductive duct, duct canister, and universal mount Plug Not Included - See Full Line Catalog for ordering information International Fans with 220 VAC, 50 Hz available. Contact Customer Service for details

12 Saddle Vent The 12 Industrial Saddle Vent SV-18912-O The 12 Industrial Saddle Vent - orange SV-UM Universal Saddle Vent mounting bracket - steel The Saddle Vent allows unrestricted entry and exit and improves ambient light in a confined space opening The 12 Saddle Vent Length: 51.5 Width: 21.0 Depth: 4.0 Weight: 11 lbs. Top Opening: 12 O.D. Bottom Opening: 12 O.D. Construction: Polyethylene Temperature Rating: +250 F Melt Temp. - 158 F Brittleness Temp. SV-18912-O International Fans with 220 VAC, 50 Hz available. Contact Customer Service for details 12 Axial Canister Fans for Non-Hazardous Locations CVF12CAN15 CVF-12AC Axial Fan with 15 (4.6 m) duct canister CVF12CAN25 CVF-12AC Axial Fan with 25 (7.6 m) duct canister SVH-1215 SVH-1225 12 Standard Ducting 12 Diameter, 15 foot length - yellow 12 Diameter, 25 foot length - yellow 12 Conductive Ducting Conductive Ducting With Ground Wires Attached to Each End of Wire Helix SVHCND1215 12 Diameter, 15 foot length - black SVHCND1225 12 Diameter, 25 foot length - black

The Saddle Vent for Special Applications Saddlator Pneumatic Powered Saddle Vent Blower The Saddlator provides positive or negative pressure ventilation for confined space entry operations in large work areas or tanks and is ideal for hazardous environments. Specifications Conductive Saddle Vent with Venturi blower installed 90 o bolt-on conductive elbow, SV90-29, supplied Air operated with no moving parts ½ Industrial Interchange plug Static ground lug installed Delivers 2000-3000 cfm on pressures from 50-100 psi Equipment Designed for Hazardous Locations For Use In Hazardous locations Air Flow Pneumatic Powered Saddle Vent Blower SV189-29 Saddlator with elbow, positive pressure flow SV189-29-N Saddlator with elbow, negative pressure flow SV90-29 90 bolt-on elbow to fit Saddlator SV189T-29 Tank Saddlator, with elbow, positive pressure flow H-50-5 ½ compressor connect hose 50 foot H-50-12 ¾ compressor connect hose 50 foot SV189-29 Tank Saddle Vent The Tank Saddle Vent is designed for ship and tank applications and fits small round and oval entry ports 20 and smaller. SV-189T SV-90T Tank Saddle Vent Tank Saddle Vent - grey 90 elbow to fit Tank Saddle Vent - grey The Tank Saddle Vent is approved for use on all U.S. Navy vessels Fire Retardant Designed to fit 18 W x 20 L oval shipboard hatch openings SV-189T

How to Use The Saddle Vent The Saddle Vent Ventilation System Typical Saddle Vent Setup Procedure 5 ft. minimum set-back required Blower or Fan Manhole Opening Select a blower or fan based on environmental conditions and the size of the confined space. For information or guidance in selecting the proper set-up, please contact Customer Service STEP 1 - Install 6 ft. duct on blower or fan STEP 2 - Install 90 elbow on top of Saddle Vent STEP 3 - Install duct on bottom of Saddle Vent STEP 4 - Install universal mount on Saddle Vent and set in place with manhole lid for support STEP 5 - Install duct from blower to 90 elbow STEP 6 - Turn on blower or fan Warning: For ventilation in hazardous locations, see warning below or call Customer Service for assistance. Warning: For hazardous locations, follow ANSI / API 2015 and 2016 procedures WARNING: HAzARDOUS LOCATION OPERATIONS Use a certified explosion-proof blower or fan, conductive ducting and the conductive Saddle Vent system. Attach all grounding wires and assure a complete circuit to the blower in order to remove static charges. The Conductive Saddle Vent System Set Up Procedure Step 1) Select an electric explosion-proof or pneumatic 8 blower with an installed metal grounding lug. Pic. 1 Step 2) Read and follow recommended work procedures found in ANSI/API 2015 and 2016 prior to entering a tank or confined space. Step 3) Use only conductive 8 ducting supplied with a continuous metal helix and a static ground wire connected to the helix. The ground wire is connected to the metal ground lug on the blower (See Pic. 1). Pic. 2 Step 4) Attach the conductive elbow to the top of the black Conductive Saddle Vent (see Pic. 2) and attach the ground wire from the duct to the elbow. If no elbow is used, an alternate ground lug is provided on the top of the Conductive Saddle Vent. Pic. 3 Step 5) Attach conductive duct to the base of the Conductive Saddle Vent and attach the ground wire to the Conductive Saddle Vent. Step 6) Test the ventilation set-up for conductivity prior to starting ventilation. Use a volt/ohm meter set to read ohms in thousands. Attach a lead from the meter to the farthest end of the duct s grounding wire and the other lead touching the ground lug on the blower. A reading less than 500K ohms will assure a good ground is achieved to allow any static charges to flow toward the grounded source (See Pic. 3). Pneumatic blowers should have a ground wire run from the blower to a grounded source. Step 7) The ventilation system is now ready for use. Place the duct and Conductive Saddle Vent system in the manhole and secure with the universal mount. Follow the Typical Saddle Vent set-up procedure found in your blower s instruction manual. For work in hazardous locations, read and follow recommended work procedures found in ANSI/API 2015 and 2016 prior to entering a tank or confined space. Copyright 2012-2018, Inc. CATSV REV. 3