Model DAC12004RC. Please read this manual carefully before use and keep it for future reference.

Similar documents
Dimplex Air Conditioner DAC 12000R

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

PORTABLE AIR CONDITIONER WITH HEATER ... WA-9061 H" 9,000 BTU WA H" 10,000BTU

Instruction Manual. Model: EPA 16 Portable Airconditioner

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

P O R T A B L E Air Conditioner

AC-12200E Portable Air Conditioner

Certified to CSA STD. C22.2 No.117

Portable Air Conditioner

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

15,000 BTU Portable Air Conditioner

PORTABLE AIR CONDITIONER

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

PORTABLE AIR CONDITIONER

Portable Air Conditioner USER MANUAL

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

MODEL: DC10RCDH / DC12RCDH

ODE20: 20 LITRE DEHUIMIDIFIER

Welcome. Important Safeguards. Please read the Manual carefully before operating the machine ELECTRICAL CONNECTIONS:

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

Reverse Cycle Portable Air Conditioner with Dehumidifier

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

MOBILE AIR CONDITIONER. User Manual PC15/20/26-BCB

Table of contents. Installing the charcoal filter 18 Cleaning the prefilter 18 Long term storage 18 Troubleshooting 19 Limited warranty 22

Portable Air Conditioner. Instruction Manual

WHYNTER PORTABLE AIR CONDITIONER

CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS...

ENGLISH INSTRUCTION MANUAL PLM 9KE-410 /12KE-410 /15KE-410 PLUS HEATER VERSIONS

PC20-AMFII / PC40-AMF USER MANUAL

Portable Air Conditioner

ACCESSORIES INCLUDED

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

USER MANUAL TPS-M5/M55/M555

Portable Air Conditioner User Manual

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

OWNER S MANUAL. Portable Refrigerated Air Conditioner. CP12CW2 (English) (CP12CW2)

Progress plus Instruction manual

Instruction Manual. Portable Air Conditioner

Arctic EVAPORATIVE COOLER USER MANUAL

WHYNTER ECO-FRIENDLY 12,000 BTU PORTABLE AIR CONDITIONER

Table of Contents. Notice: Any maintenance should be returned to the dealer or factory! Attention: Please read this instruction carefully before use.

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

Dehumidifier. User Manual

WHYNTER ECO-FRIENDLY 12,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

Dehumidifier Owner s Manual Read and save these instructions before use

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

Please read and keep manual to ensure safe and effective use of this Appliance HOUSEHOLD USE ONLY

WHYNTER ECO-FRIENDLY 12,000 BTU PORTABLE AIR CONDITIONER

Dehumidifier. Instruction Manual. Model DH-320/A

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

30-pint Dehumidifier User Guide

IMPORTANT SAFETY INSTRUCTIONS

Trotec PAC FT 2600 Portable air conditioner

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

I N S T R U C T I O N S

WHYNTER 11,000 BTU DUAL HOSE PORTABLE AIR CONDITIONER

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Dehumidifier. SD-46 SD-46W: with Warm Air SD-46U: with UV Light SD-46UW: with UV Light and Warm Air. Instruction

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

AIR CONDITIONING UNIT

COMPRESSOR DIGITAL DEHUMIDIFIER

IG9813 USER MANUAL. 12 Litre Dehumidifier White. Batch code:

22L Oven (Black) Instructions for Use

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

12L Dehumidifier Model: HG00923

Portable Air-conditioner

Local Air Conditioner

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

ARTICA. 8000Btu. Room Air Conditioners Portable Range

POLOCOOL USER MANUAL. 10,000 BTU (2.9kW) 12,000 BTU (3.5kW) PORTABLE REFRIGERATED AIR CONDITIONER. For JULY 2017

Radiant Heater. Instruction Manual QH-200 N13275

Portable Air-conditioner Use and Care Manual

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER'S MANUAL Read and save these instructions before use.

General Care and Safety Guide

OPERATING INSTRUCTIONS

Operating Instructions

Instruction Manual Item No.: V~, 60Hz

Moveable Air-conditioner User s Manual

POLOCOOL USER MANUAL. For. PC-53AP/C 19,000 BTU(5.5kW) PC-44BP/C 15,000 BTU(4.4kW) PORTABLE REFRIGERATED AIR CONDITIONER

READ AND SAVE THESE INSTRUCTIONS

Dual-Hose Portable Air Conditioner User Manual

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Thank you for buying this refrigerator-freezer. To ensure that you get the best

PORTABLE AIR CONDITIONER (LOCAL)

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

51AKB / 51 AKC OWNER S MANUAL

Portable Air Conditioner User Manual Read and save these instructions before use

Portable Room Air Conditioner and Heat Pump

PORTABLE AIR CONDITIONER

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

EVAPORATIVE AIR COOLER SERVICE MANUAL

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

Portable Air Conditioner

Transcription:

Model DAC12004RC Please read this manual carefully before use and keep it for future reference.

CONTENTS. Page Introduction........................................................ 1 Features........................................................... 2 Specification........................................................ 2 Important Safeguards................................................. 3 Energy Saving Tips................................................... 3 Parts............................................................. 4 Accessories........................................................ 5 Installation......................................................... 6 Operation......................................................... 9 Drainage......................................................... 11 Maintenance....................................................... 12 Trouble Shooting Guide.............................................. 13 Warranty......................................................... 14 Introduction. Thank you for choosing a Dimplex portable reverse cycle air conditioner. This manual contains information, regulations and warnings which are of fundamental importance if the appliance is to be installed correctly and the highest performance, in the safest possible conditions is to be obtained.we suggest that you read the manual carefully before installing or starting up the appliance. These new Dimplex appliances represent the most highly developed portable air conditioning units available today. 1

FEATURES The air-conditioning unit is of the mono tube type, transportable (on wheels) with air/air operating system for domestic use and has 3 functions. Ventilate/Fan. Cool. Heat. The ventilation mode "moves" the air allowing for its recycling much like a fan. The cooling mode, a refrigerating circuit (compressor), cools the room by transferring the heat from inside to outside though the air exhaust hose.while cooling, the airconditioning unit also dehumidifies the room air. Reverse cycle operation transforms your air conditioner into a room heater. Specifications. DAC12004RC Cooling Capacity Heating Capacity Power consumption Cooling Power consumption Heating Air Volume (max setting) Humidity removal capacity Net weight Power supply Compressor Refrigerant Fan Speed 2 Timer Thermostat Dimension (WxDxH) 12000BTU/hr 3024 Kcal/hp 3529 watts 12500 BTU/hr 3150 Kcal/hp 3676 watts 850 Watts 960 Watts 520m/h 31L/day 31kg 230-240V/50Hz Rotary R22-490 gms 1-8 hours 18-32 C Cooling Only 400 x 390 x 750 mm Test Conditions Cooling Temperature 27 C Humidity 60% Heating Temperature 20 C Humidity 60% 2

IMPORTANT SAFEGUARDS. The air conditioning unit must always be stored and transported upright, otherwise you may cause irreparable damage to the compressor; in case of doubt we suggest you wait for at least 24 hours before you start the air-conditioning unit. Avoid restarting the air conditioning unit unless 4 minutes have passed since its turned off or the compressor may get damaged. Never use the mains plug as a switch to start and turn off the air conditioning unit. Use the provided ON/OFF switch located on the control panel. Always place the portable air conditioner on a stable surface. Connect the portable air conditioner to a correct wall socket. Mount the exhaust hose on the portable air conditioner. If the supply cord is damaged, it must be replaced by an approved service representative or a similar qualified person in order to avoid a hazard. The appliance is not intended for use by young children or infirm persons without supervision. Young children or infirm persons should be supervised to ensure that they do not play with the appliance. ENERGY SAVING TIPS. Do not cover or restrict the airflow from the Outlet or Inlet grills. The minimum distance from furniture and walls should be 50cm. Keep blinds and/or draperies on any windows, closed during the sunniest part of the day. Keep the filter clean. Under normal conditions, the filters should be cleaned approximately every 30 days. Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the indoor air quality. Set the fan speed switch to high cool and the thermostat to the coolest position for the initial start-up, then set the Fan switch to low cool and lower the thermostat to a comfortable setting. Set the fan speed switch to high heat and the thermostat to the hottest position for the initial start-up.when the room has stabilized, set the Fan switch to low heat and adjust the thermostat to a comfortable setting. 3

Please read the instructions carefully and save them in a safe place for future reference. 5 6 1 7 2 3 8 10 9 4 Know your Air Conditioner. 1. Control panel 2. Air outlet 3. Handle 4. Castor 5. Air filter 6. Air inlet 7. Exhaust air outlet 8. Cord storage 9. Water stopper (rubber plug inside) 10. Water inlet draw 4

ACCESSORIES. 1. Adaptor - for insertion over hose and into back of the air conditioner 2. Exhaust hose 3. Foam strip - for filling the open window space and with hole for connection to exhaust hose 4. Foam strip - for filling the open window space 5. Round window connector 6. Cap for round window connector 7. Carbon Filter 8. Drain hose 9. Water tray 1 5 2 3 6 4 8 9 7 5

INSTALLATION Positioning of the unit This unit is a PORTABLE AIR CONDITIONER. It can be moved from room to room, so the cooling or heating can follow you anywhere.the installation is easy, beneath a window or wall. Foam Please refer to either of the following ways strips 1. Using the foam strips Connect the supplied foam strips with the exhaust pipe, allowing the hot or cold air to flow to the outside. Should the foam strip(s) be too large, cut off the extra part to fit the window. Minimum distance from the wall should be 50cm. Adaptor 50cm 2. Using the round window connectors. Make a hole (diameter 130mm) in the wall/glass to fit the supplied round window connector. Fit the hose directly to the round window connector. When the hole is not in use. Use the cap for the round window connector to cover the hole. Round window connector 50cm 6

Mounting of the exhaust pipe 1. The supplied exhaust hose can be extended from 50cm to 150cm for mounting. It is recommended that you use the hose in the shortest possible length. 2. Take care to prevent any bow or bend in the middle of the exhaust hose, as this will trap hot exhaust air, which will radiate into the room and cause this unit to shut itself off due to overheating. WARNING! The length of the exhaust pipe is specially designed according to the specification of this product. Do not replace or extend it with your own private hose as this could cause the unit to malfunction AND VOIDS YOUR WARRANTY Installation of the Carbon Filter. 1. Remove the filter frame from the unit. 2. Separate the filter fixer from the filter frame. 3. Remove the active carbon filter from the plastic bag. 4. Insert the active carbon filter into the filter frame. 5. Fix the filter by reassembling the fixer onto the filter frame. 6. Side the filter frame back into the unit. 1 6 2 3 4 5 7

Adding Water. An added feature of these models. Humidity absorbed from the air condenses at the Evaporator, turns into water and is collected in the internal tank.when enough water is collected it is pumped up and over the condenser, assisting the cooling of the refrigerated gas, increasing the COOLING CAPACITY. Some of this recycled water is evaporated at condenser and expelled from the machine as water vapour though the exhaust hose. To utilise the full potential of your air conditioner from initial start up, we recommend that 800 mls of water be added to the internal water tank via the small draw located at the rear bottom left side of the machine. Normally an adequate quantity of water is collected to keep the recycling process operating. During very humid conditions the collection of water may over take the evaporation rate and the internal tank may become full. The maximum water level in the tank is controlled by a float and micro switch, when the preset level is exceeded the indicator above the Power Switch will light and the compressor will shut off automatically, the fan motor will stay on circulating the air. At this time, you must empty the water tank as described Drainage page 11. During low humidity it maybe necessary to add move water to the internal tank If there is any doubt regards the quantity of water in the tank we suggest that you drain the tank and start again adding the 800 mls. Note! No need to add water when used in the heating function. 8

OPERATION. 1. Power indicator 2. Fan operating indicator 3. Cooling operating indicator 4. FULL WATER indicator 5. Heating Operation Indicator. 6. Thermostat. 7. Selection switch. Fan Only, 6 8. Low fan Cool, High fan Cool, 9. Low Fan Heat, High Fan Heat. 10. Timer (1-8 hours) as well as ON/OFF switch. 7 1 2 3 4 5 8 Turning ON/OFF Set TIMER to ON for continuous operation (the unit will operate as long as it is not turned off). Power indicator comes on. To turn off the unit, turn the TIMER to OFF position. Set Timer Set the TIMER to the desired operating time (1 to 8 hours). When the set time has been reached, the machine will shut off automatically. Setting Cooling, Heating and Fan only Mode Turn the selector switch knob to the required setting. Fan, Lo Fan Cool, High Fan Cool, Low Fan Heat, High Fan Heat. Setting the Temperature Turn the THERMOSTAT knob to regulate the temperature you desired. Cooling intensity is increased by clockwise direction. Heating is increased by anti clockwise direction. HIGH HEAT LOW HEAT COOLING SPEED HIGH COOL THERMOSTAT FAN LOW COOL HEATING 9

Regulating air flow direction Push the lever up or down to direct the air flow direction. NOTICE! To prolong the compressor s life, the compressor will only work 3 minutes after you switch the unit on or re-switch on. The cooling system will switch off if the ambient temperature is lower than the set one. The ventilation however, keeps working on the set level. If the ambient temperature rises above the selected level, the cooling will return to work. 10

DRAINAGE. During the process of cooling, water will be generated from the air and collected in the water tank inside the unit.when the tank is full, the compressor will stop and the Full Water indicator on the control panel will come on to remind you to empty the water tank. During this time the fan will continue to operate circulating the air.the water tank should be emptied as follows: 1. Turn off the unit. 2. Position the supplied plastic water tray, flat on the floor, under the drain hole. 3. Remove the water stopper and the rubber plug. Empty the condensed water from the air conditioner. Water stopper 4. When the water tray is almost full, replace the rubber plug to stop the flow of water, empty the water tray. 5. Repeat step 2, 3, 4, till all the condensed water is emptied. 6. After all condensed water is drained, replace the rubber plug and water stopper. The FULL WATER indicator should be off now. ATTENTION! 1. All condensed water must be drained prior to relocation or storage. Rubber plug Water tray Continuous Drainage. In very humid conditions to avoid the unit from continually shutting down when the water tank is full the unit can also be continuously drained if a convenient drainage position is available. Important! The water is only gravity drained therefore the tube must lay lower and drain at a lower level than the outlet tube at the rear of the air conditioner. Before operating the air conditioner, remove the water stopper, take out the rubber plug and connect a PVC tube 12mm diameter. Note! It maybe necessary to drain more frequently when used in the Heating function. 11

MAINTENANCE. Always unplug the unit from the mains before beginning the cleaning. Cleaning the housing Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions.these all could possibly damage the cabinet. Cleaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water (no hotter than 40 C). Dry thoroughly before replacing. NOTICE! Never operate the unit without the filters. End of season storage Unplug the unit. Drain the condensed water COMPLETELY (Please refer to drainage clause). Clean or change the filter. Turn on the unit in ventilation mode for a couple of hours, so the inside can dry out completely. It is recommended that the unit be put back into the original carton for storage and do not stack heavy objects on top of the unit. Cord Power cord storage When the unit is not in use, please store the power cord as per illustration opposite. 12

TROUBLE SHOOTING GUIDE. If the product is treated in the right manner, you should encounter no problems. In case of difficulties, please check the following points before consulting the maintenance service. Product does not work No cool air Weak ventilation performance The unit is noisy Check whether the product is plugged in. Has three minutes passed after switching on the unit, check whether the water tray is full. The room temperature should be in the operation range of 18 C-32 C Cooling Mode Is the set temp higher than the room temp. Add water as described on page 8. Check if the exhaust hose blocked or kinked. Check if the filter is dusty. Check that the unit is setting on a level surface. After long usage, the product should be cleaned by a professional maintenance service centre. 13