technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

Similar documents
technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems Indoor Units FBQ-C7VEB

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Air Conditioners. Technical Data FBQ-C

technical data air conditioning systems Indoor Units FCQ-C8VEB

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

TABLE OF CONTENTS RMXS-E8V1B

Air Conditioners. Technical Data FTXS-G

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Air conditioners, heating & cooling for shops,restaurants and offices

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Daikin air conditioners for shops, restaurant and offices

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

TABLE OF CONTENTS ERSQ-AAY1

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

Air conditioners, heating & cooling for the retailmarket and offices

EEDEN technical data ERHQ AA. Altherma. Altherma

SiE Service Manual. Split System Air Conditioners SkyAir R-407C Super Inverter 70 D Series. [Applied Models] SkyAir : Inverter Heat Pump

Daikin air conditioners for your home, shops, restaurants and offices

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

Air Conditioners Technical Data

technical data air conditioning systems RZQ B8W1B Split Sky Air

Air Conditioning Technical Data RZASG-MV1

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioning Technical Data RZAG-MV1

AIR CONDITIONERS, HEATING & COOLING for your home

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

Air Conditioning. Technical Data EEDEN AZQS-BV1

w w w. d a i k i n. e u ATXS-E

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

EEDEN technical data ERHQ AA

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioners Heating & Cooling

Air Conditioners. Technical Data RZQG-L

Daikin air conditioners for your home

4-WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices

TABLE OF CONTENTS ERHQ BAV3

Daikin air conditioners for your home

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

for your home FLXS-B Flexi type unit air to air heat pumps

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Digital Inverter 4 series 8 & 10HP

Air Conditioner SVC MANUAL(Exploded View)

Daikin air conditioners for your home

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

DESIGN & TECHNICAL MANUAL

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

DESIGN & TECHNICAL MANUAL

Daikin air conditioners for shops, restaurants and offices

technical data air conditioning systems RZQ C7Y1B Split Sky Air

for small rooms in multi application

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

Air Conditioners Technical Data

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Remote control infrared ARC433B76 ARC433A8 ARC433B69

for the retail market, hotels, restaurants and offices

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

Concealed ceiling units

DESIGN & TECHNICAL MANUAL

Daikin Air Conditioning. Daikin air conditioners for shops, restaurants and offices. CEILING SUSPENDED UNIT. UK Price List Attached

Air Conditioners Heating & Cooling

EEDEN technical data EKRTR. Altherma. Altherma

PRELIMINARY. w w w. d a i k i n e u r o p e. c o m FDQ-B

EDUS F4. FXMQ-PBVJU Ceiling Mounted Duct Type

Air Conditioners Technical Data

Fully Flat Cassette Design & Genius in one

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz

Air Conditioning Technical Data AZAS-MY1

EDUS Heat Pump - D-Series

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

DESIGN & TECHNICAL MANUAL

Air Conditioners Technical Data

RK/XS - RK/X. Outdoor units with R-410A. Pair application - inverter controlled

Air Conditioners Technical Data

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

Transcription:

technical data FHYP-B Ceiling Suspended Unit air conditioning systems Split Sky Air

Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Specifications are subject to change without prior notice. Zandvoordestraat 300 B - 8400 Ostend Belgium Internet: http://www.daikineurope.com EEDE03-/2 03/2003 Prepared in Belgium by Goekint Graphics

Ceiling Suspended Unit R-407C FHYP35-25BV TABLE OF CONTENTS FHYP-B Features... 2 2 Specifications... 3 Nominal capacity, capacity steps and nominal input Technical specifications 3 Dimensional drawings... 9 4 Piping diagrams... 5 Wiring diagrams... 2 6 Sound level... 3 Sound level data Sound pressure spectrum 7 Air flow patterns... 5 8 Accessories... 23 Standard accessories Optional accessories 9 Control systems... 25 0 Safety device settings... 26 Installation... 26 * For capacity tables, please refer to part II: outdoor units Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV Features + Leaves maximum floor and wall space for furniture, decoration and fittings + Very compact casing (only 960 mm width) + Extremely quiet in operation both indoors and outdoors + Automatic air flow director ensures uniform air flow and temperature distribution + Air flow distribution for ceilling heights up to 3.8m without loss of capacity + The outdoor unit can easily be mounted on a roof, a terrace or placed against an outside wall. + For equal distribution in larger rooms, up to 3 indoor units can be connected to outdoor. They are operated from remote control + These indoor units can also be connected to the new sky air super inverter RZP-D. + The wired remote control has a programmable timer + Centralised control of several units can be achieved via 3 wired controls centralised remote control unified ON/OFF control schedule timer 3 r 8 q x 6 Optional Optional 6 ( ) 4 2 steps 35 25 2 Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 2 Specifications NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FHYP35BV FHYP45BV FHYP60BV NOMINAL INPUT Cooling kw - - 0.5 Heating kw - - - 2 For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYP35BV FHYP45BV FHYP60BV OUTDOOR UNITS - - - CAPACITY (3) Cooling kw NOMINAL INPUT Cooling kw EER Twin/triple/double twin application only: RP-L7/B7 ENERGY LABEL ANNUAL ENERGY CONSUMPTION Cooling Cooling kw/h For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYP35BV FHYP45BV FHYP60BV OUTDOOR UNITS - - - CAPACITY (3) Cooling kw Heating kw NOMINAL INPUT Cooling kw EER COP ENERGY LABEL ANNUAL ENERGY CONSUMPTION Heating Cooling Heating Cooling kw kw/h Twin/triple/double twin application only: RYP-L7 For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYP35BV FHYP45BV FHYP60BV OUTDOOR UNITS - - - CAPACITY (3) Cooling kw Heating kw NOMINAL INPUT Cooling kw EER COP ENERGY LABEL ANNUAL ENERGY CONSUMPTION Heating Cooling Heating Cooling kw kw/h Twin/triple/double twin application only: RYEP-L7 For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYP45BV FHYP60BV OUTDOOR UNITS - - CAPACITY (3) Cooling min. nom. max. kw Heating min. nom. max. kw NOMINAL INPUT Cooling min. nom. max. kw Heating min. nom. max. kw EER COP ENERGY LABEL ANNUAL ENERGY CONSUMPTION Cooling Heating Cooling kw/h Twin application only: RZP-D Split - Sky Air Indoor Units 3

Ceiling Suspended Unit R-407C FHYP35-25BV 2 Specifications 2 NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FHYP7BV FHYP00BV FHYP25BV NOMINAL INPUT Cooling kw 0.7 0.35 0.44 Heating kw - - - For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYP7BV FHYP00BV FHYP25BV OUTDOOR UNITS RP7L7V/W-RP7B7T RP00L7V/W-RP00B7T RP25L7W-RP25B7T CAPACITY (3) Cooling kw 7.00 0.00 2.20/2.50 NOMINAL INPUT Cooling kw 2.68/2.62/2.6 3.75/3.72/3.62 4.53/4.69 EER 2.65/2.7/2.72 2.67/2.69/2.76 2.69/2.67 ENERGY LABEL Cooling D/D/D D/D/D D/D ANNUAL ENERGY CONSUMPTION Cooling kw/h,340/,30/,305,875/,860/,80 2,265/2,345 Note: FHYP35-45-60BV: Twin/triple/double twin application only For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYP7BV FHYP00BV FHYP25BV OUTDOOR UNITS RYP7L7V/W RYP00L7V/W RYP25L7W CAPACITY (3) Cooling kw 7.0 0.00 2.20 Heating kw 8.00.20 4.00 NOMINAL INPUT Cooling kw 2.70/2.65 3.68/3.56 4.46 Heating kw 2.85/2.80 3.90/3.85 4.99 EER 2.63/2.68 2.72/2.74 2.74 COP 2.8/2.86 2.82/2.86 2.8 ENERGY LABEL Cooling D/D D/D D Heating D/D D/D D ANNUAL ENERGY CONSUMPTION Cooling kw/h,350/,325,840/,825 2,230 Note: FHYP35-45-60BV: Twin/triple/double twin application only For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYP7BV FHYP00BV FHYP25BV OUTDOOR UNITS RYEP7L7V/W RYEP00L7V/W RYEP25L7W CAPACITY (3) Cooling kw 7.0 0.00 2.20 Heating kw 8.00.00 4.00 NOMINAL INPUT Cooling kw 2.72/2.65 3.78/3.79 4.46 Heating kw 3.00/2.85 3.9/3.9 4.99 EER 2.6/2.68 2.65/2.64 2.74 COP 2.67/2.8 2.8/2.8 2.8 ENERGY LABEL Cooling D/D D/D D Heating E/D D/D D ANNUAL ENERGY CONSUMPTION Cooling kw/h,360/,325,890/,895 2,230 Note: FHYP35-45-60BV: Twin/triple/double twin application only For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYP7BV FHYP00BV FHYP25BV OUTDOOR UNITS RZP7DV RZP00DV RZP25DV CAPACITY (3) Cooling min. nom. max. kw 3.29 7.2 7.99 5.00 9.99.4 5.94 2.49 4.32 Heating min. nom. max. kw 3.48 8.02 9.00 5.63.20 2.8 6.00 4.0 6.20 NOMINAL INPUT Cooling min. nom. max. kw 0.6 2.2 2.70 0.90 3.00 3.60.08 3.60 4.68 Heating min. nom. max. kw 0.65 2.49 2.96.6 3.50 4.27.2 4.52 5.40 EER 3.22 3.33 3.47 COP 3.22 3.20 3.0 ENERGY LABEL Cooling A A A Heating C D D ANNUAL ENERGY CONSUMPTION Cooling kw/h,05,500,800 Note: FHYP45-60BV: Twin application only 4 Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 2 Specifications TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FHYP35BV FHYP45BV FHYP60BV DIMENSIONS Unit H mm 95 W mm 960,60 D mm 680 WEIGHT Unit kg 23 24 26 COLOUR Decoration panel White SOUND LEVEL Sound pressure high db(a) 37/37 38/38 (cooling/heating) () low db(a) 32/32 33/33 Sound power high db(a) 53/53 54/54 (cooling/heating) (2) low db(a) 48/48 49/49 FAN Air flow rate (cooling/heating) high m 3 /min 3/3 6/6 low m 3 /min 0/0 3/3 Speed steps 2 steps Type Sirocco fan Qty x motor output W x 62 HEAT EXCHANGER Type Cross fin coil (Multi louver fins and N-HiX tubes) Rows x stages x fin pitch mm 2 x 2 x.75 3 x 2 x.75 Face area m 2 0.82 0.233 PIPING CONNECTIONS liquid flare mm φ6.4 φ9.5 gas flare mm φ2.7 φ5.9 φ5.90 drain I.D. mm φ25 drain O.D. mm φ32 INSULATION MATERIAL Heat insulation Both liquid and gas pipes Sound absorbing insulation Flame and heat resistant foamed polyethylene, regular foamed polyethylene and foamed PU 2 For outdoor units only: Pair application See chapters RP-L7/B7, RYP-L7, RYEP-L7, RZP-D Split - Sky Air Indoor Units 5

Ceiling Suspended Unit R-407C FHYP35-25BV 2 Specifications 2 TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FHYP7BV FHYP00BV FHYP25BV DIMENSIONS Unit H mm 95 W mm,60,400,590 D mm 680 WEIGHT Unit kg 27 32 35 COLOUR Decoration panel White SOUND LEVEL Sound pressure high db(a) 39/39 42/42 44/44 (cooling/heating) () low db(a) 35/35 37/37 39/39 Sound power high db(a) 55/55 58/58 60/60 (cooling/heating) (2) low db(a) 5/5 53/53 55/55 FAN Air flow rate high m 3 /min 7/7 24/24 30/30 (cooling/heating) low m 3 /min 4/4 20/20 25/25 Speed steps 2 steps Type Sirocco fan Qty x motor output W x 62 x 30 HEAT EXCHANGER Type Cross fin coil (Multi louver fins and N-HiX tubes) Rows x stages x fin pitch mm 3 x 2 x.75 Face area m 2 0.233 0.293 0.34 PIPING CONNECTIONS liquid flare mm φ9.5 gas flare mm φ5.90 φ9.0 drain I.D. mm φ25 drain O.D. mm φ32 INSULATION MATERIAL Heat insulation Both liquid and gas pipes Sound absorbing insulation Flame and heat resistant foamed polyethylene, regular foamed polyethylene and foamed PU For outdoor units only: Pair application See chapters RP-L7/B7, RYP-L7, RYEP-L7, RZP-D 6 Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 2 Specifications ELECTRICAL SPECIFICATIONS For indoor units only: FHYP35BV FHYP45BV FHYP60BV CURRENT Nominal running current cooling/heating A See chapters RP-L7/B7, RYP-L7/B7, RYEP-L7, RZP-D Maximum running current cooling/heating A See chapters RP-L7/B7, RYP-L7/B7, RYEP-L7, RZP-D 2 For combination indoor units + outdoor units: FHYP35BV FHYP45BV FHYP60BV - - - CURRENT Nominal running current cooling A Maximum running current cooling A Twin/triple/double twin application only: RP-L7/B7 Starting current cooling A For combination indoor units + outdoor units: FHYP35BV FHYP45BV FHYP60BV - - - CURRENT Nominal running current cooling/heating A Maximum running current cooling/heating A Twin/triple/double twin application only: RYP-L7 Starting current cooling/heating A For combination indoor units + outdoor units: FHYP35BV FHYP45BV FHYP60BV - - - CURRENT Nominal running current cooling/heating A Maximum running current cooling/heating A Twin/triple/double twin application only: RYEP-L7 Starting current cooling/heating A For combination indoor units + outdoor units: FHYP45BV FHYP60BV - - CURRENT Nominal running current cooling/heating A Maximum running current cooling/heating A Twin application only: RZP-D Starting current cooling/heating A For indoor units only: FHYP35BV FHYP45BV FHYP60BV POWER SUPPLY V V V NOMINAL DISTRIBUTION Phase SYSTEM VOLTAGE Frequency Hz 50 50 50 Voltage V 230 230 230 NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Nominal heating capacities are based on: indoor temperature: 20 CDB * outdoor temperature: 7 CDB/6 CWB * refrigerant piping length: 7.5m * level difference 0m. 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 The sound pressure level is measured at.5m distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 6 of this chapter. 5 The sound power level is an absolute value indicating the power which a sound source generates. 6 Energy label: scale from A (most efficient) to G (less efficient). 7 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions). Split - Sky Air Indoor Units 7

Ceiling Suspended Unit R-407C FHYP35-25BV 2 Specifications 2 ELECTRICAL SPECIFICATIONS For indoor units only: FHYP7BV FHYP00BV FHYP25BV CURRENT Nominal running current cooling/heating A See chapters RP-L7/B7, RYP-L7, RYEP-L7, RZP-D Maximum running current cooling/heating A See chapters RP-L7/B7, RYP-L7, RYEP-L7, RZP-D For combination indoor units + outdoor units: FHYP7BV FHYP00BV FHYP25BV RP7L7V/W-RP7B7T RP00L7V/W-RP00B7T RP25L7W-RP25B7T CURRENT Nominal running current cooling A Maximum running current cooling A See chapter RP-L7/B7 Starting current cooling A Note: FHYP35-45-60BV: Twin/triple/double twin application only For combination indoor units + outdoor units: FHYP7BV FHYP00BV FHYP25BV RYP7L7V/W RYP00L7V/W RYP25L7W CURRENT Nominal running current cooling/heating A Maximum running current cooling/heating A See chapter RYP-L7 Starting current cooling/heating A Note: FHYP35-45-60BV: Twin/triple/double twin application only For combination indoor units + outdoor units: FHYP35BV FHYP45BV FHYP60BV RYEP7L7V/W RYEP00L7V/W RYEP25L7W CURRENT Nominal running current cooling/heating A Maximum running current cooling/heating A See chapter RYEP-L7 Starting current cooling/heating A Note: FHYP35-45-60BV: Twin/triple/double twin application only For combination indoor units + outdoor units: FHYP7BV FHYP00BV FHYP25BV RZP7DV RZP00DV RZP25DV CURRENT Nominal running current cooling/heating A Maximum running current cooling/heating A See chapter RZP-D Starting current cooling/heating A Note: FHYP45-60BV: Twin application only For indoor units only: FHYP7BV FHYP00BV FHYP25BV POWER SUPPLY V V V NOMINAL DISTRIBUTION Phase SYSTEM VOLTAGE Frequency Hz 50 50 50 Voltage V 230 230 230 3D028492 NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Nominal heating capacities are based on: indoor temperature: 20 CDB * outdoor temperature: 7 CDB/6 CWB * refrigerant piping length: 7.5m * level difference 0m. 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 The sound pressure level is measured at.5m distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 6 of this chapter. 5 The sound power level is an absolute value indicating the power which a sound source generates. 6 Energy label: scale from A (most efficient) to G (less efficient). 7 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions). 8 Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 3 Dimensional drawings FHYP35 45BV 3 (Hanging position) Position slit hole for taking out in piping back (View from the front) (Required space) (Required space) Hanging bolt (Hanging position) Position: hole of wall for taking out in piping back (View from the front) For height installation 780 From the floor side 2500 or more Obstacle Note:. Location of unit s name plate: bottom of fan housing inside the suction grille. 2. In case of using infrared remote control, this position will be a signal receiver. Refer to the drawing of infrared remote control in detail. 3. The remote control code is the standard (about 3m outside the machine) attached. (0.5 mm 2 x 2 Wicks x O.D. J5.4) (It is not attached in VRV.) 300or more (Required space) Floor side 30 or more (Service space) Drain pipe connection VP20 (For left piping) View from the front 30 or more (Service space) Brand name plate (Note 2) Air discharge grille 2 Air suction grille 3 Air filter 4 Gas pipe connection J2.7 flare 5 Liquid pipe connection J6.4 flare 6 Drain pipe connection VP20 7 Earth terminal (inside the electric components box) M4 8 Suspension bracket 9 Backward piping and wiring connection opening lid 0 Upward piping and wiring connection opening lid Right side pipe connection - slit hole 2 Left back drain pipe connection - slit hole 3 Right side drain pipe connection - slit hole 4 Right side drain piping connection hole- slit hole 5 Hole of wall for taking out in piping back J00 6 Upward drain pipe connection J60 7 Upward gas pipe connection J36 8 Upward liquid pipe connection J26 3D027536C FHYP60 7BV (Hanging position) Position slit hole for taking out in piping back (View from the front) (Required space) (Required space) Hanging bolt (Hanging position) Position: hole of wall for taking out in piping back (View from the front) For height installation 780 From the floor side 2500 or more Obstacle Note:. Location of unit s name plate: bottom of fan housing inside the suction grille. 2. In case of using infrared remote control, this position will be a signal receiver. Refer to the drawing of infrared remote control in detail. 3. The remote control code is the standard (about 3m outside the machine) attached. (0.5 mm 2 x 2 Wicks x O.D. J5.4) (It is not attached in VRV.) 300 or more (Required space) Floor side 30 or more 30or more (Service space) (Service space) View from the front Brand name plate (Note 2) Drain pipe connection VP20 (For left piping) Air discharge grille 2 Air suction grille 3 Air filter 4 Gas pipe connection J5.9 flare 5 Liquid pipe connection J9.5 flare 6 Drain pipe connection VP20 7 Earth terminal (inside the electric components box) M4 8 Suspension bracket 9 Backward piping and wiring connection opening lid 0 Upward piping and wiring connection opening lid Right side pipe connection - slit hole 2 Left back drain pipe connection - slit hole 3 Right side drain pipe connection - slit hole 4 Right side drain piping connection hole- slit hole 5 Hole of wall for taking out in piping back J00 6 Upward drain pipe connection J60 7 Upward gas pipe connection J36 8 Upward liquid pipe connection J26 3D027538B Split - Sky Air Indoor Units 9

Ceiling Suspended Unit R-407C FHYP35-25BV 3 Dimensional drawings 3 FHYP00BV (Hanging position) Position slit hole for taking out in piping back (View from the front) (Required space) (Required space) Hanging bolt (Hanging position) Position: hole of wall for taking out in piping back (View from the front) For height installation 780 From the floor side 2500 or more Obstacle Note:. Location of unit s name plate: bottom of fan housing inside the suction grille. 2. In case of using infrared remote control, this position will be a signal receiver. Refer to the drawing of infrared remote control in detail. 3. The remote control code is the standard (about 3m outside the machine) attached. (0.5 mm 2 x 2 Wicks x O.D. J5.4) (It is not attached in VRV.) 300 or more (Required space) Floor side 30 or more (Service space) Drain pipe connection VP20 (For left piping) View from the front 30 or more (Service space) Brand name plate (Note 2) Air discharge grille 2 Air suction grille 3 Air filter 4 Gas pipe connection J9. flare 5 Liquid pipe connection J9.5 flare 6 Drain pipe connection VP20 7 Earth terminal (inside the electric components box) M4 8 Suspension bracket 9 Backward piping and wiring connection opening lid 0 Upward piping and wiring connection opening lid Right side pipe connection - slit hole 2 Left back drain pipe connection - slit hole 3 Right side drain pipe connection - slit hole 4 Right side drain piping connection hole- slit hole 5 Hole of wall for taking out in piping back J00 6 Upward drain pipe connection J60 7 Upward gas pipe connection J36 8 Upward liquid pipe connection J26 3D027539B FHYP25BV (Hanging position) Position slit hole for taking out in piping back (View from the front) (Required space) (Required space) Hanging bolt (Hanging position) Position: hole of wall for taking out in piping back (View from the front) For height installation 780 From the floor side 2500 or more Obstacle 300or more Note:. Location of unit s name plate: bottom of fan housing inside the suction grille. 2. In case of using infrared remote control, this position will be a signal receiver. Refer to the drawing of infrared remote control in detail. 3. The remote control code is the standard (about 3m outside the machine) attached. (0.5 mm 2 x 2 Wicks x O.D. J5.4) (It is not attached in VRV.) (Required space) Floor side 30 or more 30or more (Service space) Drain pipe connection VP20 (For left piping) View from the front (Service space) Brand name plate (Note 2) Air discharge grille 2 Air suction grille 3 Air filter 4 Gas pipe connection J9. flare 5 Liquid pipe connection J9.5 flare 6 Drain pipe connection VP20 7 Earth terminal (inside the electric components box) M4 8 Suspension bracket 9 Backward piping and wiring connection opening lid 0 Upward piping and wiring connection opening lid Right side pipe connection - slit hole 2 Left back drain pipe connection - slit hole 3 Right side drain pipe connection - slit hole 4 Right side drain piping connection hole- slit hole 5 Hole of wall for taking out in piping back J00 6 Upward drain pipe connection J60 7 Upward gas pipe connection J36 8 Upward liquid pipe connection J26 3D027540 0 Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 4 Piping diagrams FHYP35 25B 4 Indoor heat exchanger Refrigerant pipe connection port diameters Model A B FHYP35-45BV 6.4 2.7 FHYP60-7BV 9.5 5.9 FHYP00-25BV 9.5 9. Field piping Field piping To outdoor unit Indoor unit O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe 4D024085A Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 5 Wiring diagrams 5 FHYP35 25BV In case of simultaneous operation system. Wired remote control Notes Indoor unit (master) Indoor unit (slave) To outdoor unit. D : Terminal F, H : Connector b : Protective earth (screw) 2. B : Field wiring 3. In case using central remote control, connect it to the unit in accordance with the attached instruction manual. 4. X24A is connected when the infrared remote control kit is being used. 5. Remote controller model varies according to the combination system, confirm technical materials and catalogs, etc. before connecting. 6. Symbols show as follows Red:red, Blk:black, Ylw:yellow, Org:orange, Gry:gray, Prp:purple, Blu:blue 7. Confirm the method of setting the selector switch (SS, SS2) by installation manual and engeneering materials, etc. To outdoor unit Infrared remote controller Note) 4 Receiver / display unit Note) 6 Note) 4 Note) 6 -RED, 2-WHITE, 3-BLACK 33A Limit switch (swing flap) AP Printed circuit board CR Capacitor (MF) HAP Light emitting diode (service monitor green) HBP Light emitting diode (service monitor green) MA Motor (swing flap) MF Motor (indoor fan) QF Thermo switch (MF embedded) RT Thermistor (air) R2T Thermistor (coil) RyA Magnetic relay (MA) RyP Magnetic relay (MP) SS Selector switch (emergency) TR Transformer XM Terminal strip X2M Terminal strip? Signal receiver circuit. Signal transmission circuit = Phase control circuit Wired remote control RT Thermistor (air) SS Selector switch (main/sub) Infrared remote control Receiver / display unit A3P Printed circuit board A4P Printed circuit board BS Push button (on/off) HP Light emitting diode (service monitor red) H2P Light emitting diode (service monitor green) H3P Light emitting diode (service monitor red) H4P Light emitting diode (service monitor orange) SS Selector switch (main/sub) SS2 Selector switch (wireless address set) Connector for optional parts X5A Connector (float switch) X25A Connector (drain pump) X30A Connector (interface adapter for sky air series) X33A Connector (adapter for wiring) X35A Connector (group control adapter) X40A Connector ON/OFF input from outside Switch box 3D027503-2 Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 6 Sound level 6- Sound level data Model H (cooling/heating) 230V 50Hz L (cooling/heating) Sound pressure level Measuring location Sound power level (H) (cooling/heating) FHYP35B 37/37 32/32 53/53 FHYP45B 38/38 33/33 54/54 FHYP60B 38/38 33/33 54/54 FHYP7B 39/39 35/35 Microphone 55/55 FHYP00B 42/42 37/37 58/58 FHYP25B 44/44 39/39 60/60 6 6-6-2 Sound pressure spectrum Cooling only FHYP35BV FHYP45BV Octave band sound pressure level Octave band sound pressure level H L H L approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D028280A Octave band center frequency (Hz) 4D02828A Octave band center frequency (Hz) FHYP60BV Octave band sound pressure level H NOTES Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. 3 Sound levels are valid at nominal operation conditions. L approximate threshold hearing for continuous noise 4D028282 Octave band center frequency (Hz) Split - Sky Air Indoor Units 3

Ceiling Suspended Unit R-407C FHYP35-25BV 6 Sound level 6 6-2 6-2 Sound pressure spectrum Heat pump FHYP7BV FHYP00BV Octave band sound pressure level Octave band sound pressure level H H L L approximate threshold hearing for continuous approximate threshold hearing for continuous noise noise 4D028355 Octave band center frequency (Hz) 4D028283 Octave band center frequency (Hz) FHYP25BV Octave band sound pressure level H NOTES Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. 3 Sound levels are valid at nominal operation conditions. L approximate threshold hearing for continuous noise 4D028284 Octave band center frequency (Hz) 4 Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 7 Air flow patterns FHYP35-45BV Cooling - air velocity distribution 7 Air flow direction: horizontal FHYP35-45BV Cooling - air temperature distribution Air flow direction: horizontal 4D028550 Split - Sky Air Indoor Units 5

Ceiling Suspended Unit R-407C FHYP35-25BV 7 Air flow patterns 7 FHYP35-45BV Heating - air velocity distribution Air flow direction: 45 (downward) FHYP35-45BV Heating - air temperature distribution Air flow direction: 45 (downward) 4D028554 6 Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 7 Air flow patterns FHYP60-7BV Cooling - air velocity distribution 7 Air flow direction: horizontal FHYP60-7BV Cooling - air temperature distribution Air flow direction: horizontal 4D02855 Split - Sky Air Indoor Units 7

Ceiling Suspended Unit R-407C FHYP35-25BV 7 Air flow patterns 7 FHYP60-7BV Heating - air velocity distribution Air flow direction: 45 (downward) FHYP60-7BV Heating - air temperature distribution Air flow direction: 45 (downward) 4D028555 8 Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 7 Air flow patterns FHYP00BV Cooling - air velocity distribution 7 Air flow direction: horizontal FHYP00BV Cooling - air temperature distribution Air flow direction: horizontal 4D028552 Split - Sky Air Indoor Units 9

Ceiling Suspended Unit R-407C FHYP35-25BV 7 Air flow patterns 7 FHYP00BV Heating - air velocity distribution Air flow direction: 45 (downward) FHYP00BV Heating - air temperature distribution Air flow direction: 45 (downward) 4D028556 20 Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 7 Air flow patterns FHYP25BV Cooling - air velocity distribution 7 Air flow direction: horizontal FHYP25BV Cooling - air temperature distribution Air flow direction: horizontal 4D028553 Split - Sky Air Indoor Units 2

Ceiling Suspended Unit R-407C FHYP35-25BV 7 Air flow patterns 7 FHYP25BV Heating - air velocity distribution Air flow direction: 45 (downward) FHYP25BV Heating - air temperature distribution Air flow direction: 45 (downward) 4D028557 22 Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 8 Accessories 8- Standard accessories FHYP-B Name j Drain hose j2 Clamp j3 Washer for hanging bracket j4 Clamp j5 Washer fixing plate 8 8- Quantity pc. pc. 8 pcs. 6 pcs. pc. Shape Name Insulation for fitting Sealing pad Quantity of each pc. (Other) + Installation manual Shape j8 For gas pipe j8 Large + Operation manual j7 For liquid pipe j7 Small 8-2 Optional accessories Name of option Remark FHYP-BV 35 45 60 7 00 25 Replacement long-life filter KAFJ50D56 KAFJ50D80 KAFJ50D2 KAFJ50D60 Drain up kit KDU50B50VE KDU50B7VE KDU50B25VE L-type piping kit (for upward direction) For FHY KHFJ5F50 KHFJ5F80 KHFJ5F60 For FH KHFJ5F50 KHFJ5F60 Remote control Wired type BRCD57 Infrared type For FHY BRC7E63W For FH BRC7E66 Central remote control DCS302B5 Unified ON/OFF control DCS30B5 Schedule timer DST30B5 Adapter for wiring KRPB54 Wiring adapter (hour meter) EKRPB2 Wiring adapter for electrical appendices z KRP4A52 Interface adapter for Sky Air series DTA02A52 Installation box for adapter PCB KRPC93 Remote ON/OFF, forced OFF EKRORO 3D028285A Note *: Installation box for adapter PCB (KRPC93) is necessary. Split - Sky Air Indoor Units 23

Ceiling Suspended Unit R-407C FHYP35-25BV 8 Accessories 8 8-2 8-2 Optional accessories Specifications EKRORO Wire specifications Connector (White) connect to indoor PCB (X40A) White connect to on/off switch AWG24 0.22mm 2 White Operating method ON* Switch Unit Input Remote control Standard setting: forced off Alternative setting: on/off OFF ON OFF ON OFF ON OFF * Input ON = closed contact. Forced off Input on stops operation + disables control Input off enables control On/off operation Input off on: starts operation, remote control is still enabled. Input on off: stops operation, remote control is still enabled. Selection of FORCED OFF and ON/OFF operation Setting Mode NO First code NO Second code NO Forced off 2 (22) 0 On/off operation 02 4TW2394-24 Split - Sky Air Indoor Units

Ceiling Suspended Unit R-407C FHYP35-25BV 9 Control systems 9- Wired remote control BRCD57 9 9-5 x 0 (Round end slit) 6.5 x 9 (Round end slit) Cover closed 5 x 7 (Round end slit) HoleJ5 Cover open 3TW2365-2 Split - Sky Air Indoor Units 25

Ceiling Suspended Unit R-407C FHYP35-25BV 0 Safety device settings 0 FHYP-BV Model Safety devices 35 50 60 7 00 25 Fuse Fan motor thermal fuse ( C) Fan motor thermal protector ( C) OFF: 30±5 ON: 83±20 OFF: 30±5 ON: 83±20 OFF: 30±5 ON: 83±20 OFF: 30±5 ON: 83±20 OFF: 30±5 ON: 83±20 OFF: 30±5 ON: 83±20 3D0066F Installation Names and functions of parts ja Indoor unit jb Outdoor unit jc Infrared remote control jd Inlet air je Discharged air jf Air outlet jg Blade (at air outlet) jh Refrigerant piping, connection electric wire ji Drain pipe j Air inlet The built-in air filter removes dust and dirt. jk Ground wire Wire to ground from the outdoor unit to prevent electrical shocks. 26 Split - Sky Air Indoor Units