HV to HE Conversion Kit Installation

Similar documents
ESP. Variable Speed Heat Pump. Installation and Operation. 3 Ton ESP Ton ESP-60

LV Installation Manual

LV Installation Manual

R Series Cooling Manual

JH Series Installation

Parts List * October 2013

Mini Duct Heating and Air Conditioning Indoor Air Quality Systems. July Featuring: Also Including: Lo-Velocity Systems JH Fancoils

HE-B Series Commissioning Report & User Guide

Commercial Applications

Featuring: Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems

R Series Cooling Modules

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

AirPurification System

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F*FP LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0209

Z24 Wireless Zone Controller Professional Installation Guide

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

E1 Electrical Fundamentals. # 4 - Symbols and Wiring Diagrams

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F6FP018** - 060** TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0409

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS

Installation Instructions HEAT COOL FAN POWER

INSTALLATION INSTRUCTION

INSTALLATION MANUAL MODULAR VARIABLE SPEED AIR HANDLERS MODELS: MV LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

Premier 2-Zone Controller model Installer Guide

How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables.

Installation Guide ProR221J, ProR212J, ProR321J and ProR312J

R Series Cooling Modules

Installation. Table of Contents. 1. Description/ Application. Form I-CAUA-CC (04-15) Obsoletes Form I-CAUA-CC (Version C.1)

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION AND OPERATION INSTRUCTIONS 303, 304, 305, CRH, CRQ, CFA SERIES 2250 WATT MODELS

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

REPLACEMENT PARTS MANUAL

Installation Instructions

LOW VOLTAGE CONTROL CIRCUIT WIRING

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

ONX908FCT-4B/220V/RC FAN COIL THERMOSTAT

5.0 AIR HANDLER Comfort Control 2 System INTERFACE BOARD

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

HRV Vertical Unit Ventilators

INSTALLATION MANUAL SINGLE PACKAGE HEAT PUMP/ELECTRIC

NAH Series. NAH Series Hydronic Air Handler Installation Manual. Air Handler. Installation Information. Water Piping Connections

5.0 AIR HANDLER EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM INTERFACE BOARD

Installation Guide.

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

AG Series Electric Heaters

Safety & Installation Instructions

MERIT SERIES Up Flow / Horizontal

ECAH SERIES ECM AIR HANDLER

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

AIR HANDLER R-410A Refrigerant 2-5 Tons. Submittal Data English Language/IP Units SD1008HN 07/15

Commercial Thermostat

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION ECM AIR HANDLERS MODELS: AHV SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

MERIT Series R-410A - Upflow / Horizontal

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

RE9X Series Downflow, Upflow Electric Furnaces

USERS INFORMATION MANUAL

Wiring Diagrams. 9AB4-12 Air-Cooled Remote Condenser INDEX OPERATING SEQUENCE ACCESSORIES LEGEND AND NOTES FOR FIG. 1-6

MERIT Series R-410A - Upflow / Horizontal

XE99 SERIES FAN-COIL THERMOSTATS 2-PIPE & 4-PIPE FAN-COIL CONTROL FEATURES APPLICATION PRODUCT SPECIFICATION SHEET

RCM Refrigerant Module

Envision Air Handler Specification Catalog

INSTALLATION/OPERATING INSTRUCTIONS SEQUENCING PANELS

Installation Instructions

SmartZone TM System Manual

Your safety and the safety of others are very important.

INSTALLATION MANUAL MODELS: E30 SERIES SAVE THIS MANUAL FOR FUTURE REFERENCE

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

GLAS. Installation Instructions

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

1F98EZ-1421, Easy Install

Installation Instructions

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

Technical. Catalogue. NA Version PDWL AECM. LSTAT Series Hydronic EC Ducted Fan Coil

SPECIFICATION CATALOG

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

TECHNICAL GUIDE MODELS: GM9T-UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

TECHNICAL GUIDE. Echelon MODELS: FC9M*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW MODULATING FURNACES

5 Series 500A11 Installation Manual

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

Installation Instructions

T4360G, T6360D, T6360E Line Voltage Thermostat

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

HI-VELOCITY SYSTEMS

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

INSTALLATION INSTRUCTIONS

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

WIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873

TSTAT0101SC Recommended (order separately)

TECHNICAL GUIDE. Echelon MODELS: FC9T GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Transcription:

Small Duct Heating, ooling and Indoor Air Quality Systems www.hi-velocity.com TM HV to HE onversion Kit Installation Manufactured By Module HK - HV to HE onversion Kit Installation 032410

Motor and Blower Preparation Module HK HV to HE onversion (2/10) This document will show you step by step instructions on converting a HV fancoil with a multi-speed motor to the HE style with a variable speed motor. The HE ontrol Board is programmed with multiple speeds and air flows controlled by the thermostat and dip set ranges for each style of blower. The ontrol Board converts the supplied single phase power of 100v-240v and converts the power to 3 phase motor and sends 3 phase power to the motor. The Heavy Duty 3 Phase Motor provides years of reliable service, as the heavy duty construction and power limiting function of the EP controller minimizes motor stress and wear. The new inverter drive technology offered by the EP Motor and ontroller reduces power consumption by up to 70%, with an average overall yearly reduction of 50% over standard PS motors. oise related to excess power input is eliminated. Part Part umber HE-50 onversion Kit 20160100050 HE-70 onversion Kit 20160100070 HE-100 onversion Kit 20160100100 HV to HE onversion Kit Each kit will include the following: EP 3/4 hp Motor c/w Motor Mounting Bracket Electrical Box c/w ontrol Board, ircuit Board and Transformer HE enter Plate (50, 70 or 100 Size) HE Blower (50, 70, 100 Size) (1 1/2") (1 1/2 ) (1 1/4") ot Used Mounting Bolt Assembly 1 1/4" HE-50/52 HE-70 HE-100 HE-50 1/2 HE-52 7/8" HE-70 2" Middle OTE: Bracket bolt and wire to line up (center) HE-70&100 HE-50: Just below the silver rim, line up bolt and wire as shown HE-70: 2 from flat part of the silver rim HE-100: Middle of the motor housing enter blower wheel in the blower cabinet and tighten the set screw on blower to motor, be sure to use thread lock glue on set screw Wire as shown here (bottom/side) OTE: This manual applies to the HV single sided access units manufactured from 2002-2008 with the blower mounted on the center plate. For older units with the blower mounted on the fan coil cabinet, simply remove the controls, center plate blower and blower/motor, and install conversion kit as per shown in this manual. Module HK - HV to HE onversion Kit Installation (2/10) -2-1995-2009 Energy Saving Products td.

Module HK HV to HE onversion (3/10) 1. Shut off electric power to the unit. HV Fan oil Preparation 2. Make note of the pump timer setting. abel all wires before disconnecting when servicing controls. Wiring errors can cause improper and dangerous operation. 3. Disconnect electrical power from the circuit board. 4. Disconnect motor connection and all thermostat wires, condensing unit, freeze stat, circulator, zone valve etc. It is not necessary to remove wires completely from the fan coil, it may be necessary to bring the wires into the new HE Electrical box before sliding the electrical box into place. 5. Remove existing HV ircuit Board Electrical box. 6. Remove mounted motor and blower. 7. arefully remove center plate trying not to damage the insulation lining in the unit. Depending on the clearance on the outside of the fan coil, it may be easier to cut the screws from inside, depending on the clearances around the unit. Remove Screws 5 6 7 Module HK - HV to HE onversion Kit Installation (3/10) -3-1995-2009 Energy Saving Products td.

Module HK HV to HE onversion (4/10) HE omponent Installation 8. Bend down the HV ontrol Box mounting metal tabs flat if located in fan coil. 9.Install new center plate, careful not to damage the insulation lining in the unit. 10. Replace screws. Depending on the clearance on the outside of the fan coil, it may be easier to replace the screws from the inside to out. 11. Install EP mounted motor and blower. 12. Install EP Electrical box and connect motor. (See next page) 12 Replace Screws 10 8 11 9 Module HK - HV to HE onversion Kit Installation (4/10) -4-1995-2009 Energy Saving Products td.

HE Electrical Box Installation Module HK HV to HE onversion (5/10) 13. Slide ontrol Box into fan coil allow the metal flange to clip onto the fan coil cabinet while the other side simply rests on the Fan oil cabinet. 14. Bring motor wires into control box, insert wires into plastic clip and insert plastic clip to protect the motor wires. Reconnect motor to the control board. 13 15. onnect motor ground to the electric board box. 15 14 16. Reconnect all thermostat wires, condensing unit, freeze stat, circulator, zone valve etc. hange pump timer setting and dip switch settings for the new board assembly. Reconnect electrical power to the board. 17. Replace door covers on fan coil and replace wiring sticker on the door. Write down on provided sticker the Model and Serial umber of the fan coil and stick to the bottom of old control box. Return to supplier. Module HK - HV to HE onversion Kit Installation (5/10) -5-1995-2009 Energy Saving Products td.

Module HK HV to HE onversion (6/10) Wiring 1 Stage stage ooling cooling 1 Stage 1 stage Heating heating 24v 1 stage Stage ooling cooling 2 Stage 2 stage Heating heating Heatpump heatpump DESER DESER Y 24v Y O/B R SAMPE AUXIIARY REAY WIRIG OPTIS FOR HEATIG (W1 OR W2) R Z1 - HEATIG MODE 24V OUTPUT (W2 Y) ATI-IE TRO AD X2 - WIRES TO ATI-IE TRO, DESIG UIT Y AD SIGA FROM H1 AD TO OMPETE SIGA Z1 - HEATIG MODE 24V OUTPUT (W2 Y) ATI-IE TRO AD X2 - WIRES TO ATI-IE TRO, DESIG UIT Y AD SIGA FROM H1 AD TO OMPETE SIGA DRY TATS REAY WIRIG 24 VA REAY WIRIG 115 VA REAY WIRIG SAMPE AUXIIARY REAY WIRIG OPTIS FOR HEATIG (1 STAGE - W2 Y) Z1 H1 X2 AUXIIARY REAY (HEATIG) AD - HEATIG MODE AUXIIARY TAT W1 AD W2 Y Z1 H1 X2 AUXIIARY REAY (HEATIG) AD - HEATIG MODE AUXIIARY TAT W1 AD W2 Y DRY TAT TO BOIER EXTERA SPDT REAY 24 VA OI DRY TATS AD 115 VA REAY WIRIG T T X2 H1 Z1 115v IRUATOR W1 W2 G R Y2 Y1 D O/B W1 W2 G R Y2 Y1 D O/B SAMPE AUXIIARY REAY WIRIG OPTIS FOR HEATIG (W1 OR W2) W G R Y THERMOSTAT E W2 G R Y O/B THERMOSTAT Z1 H1 X2 DRY TAT TO BOIER T T EXTERA SPDT REAY 24 VA OI 115 V TO IRUATOR 1 Stage stage ooling cooling 2 Stage 2 stage Heating heating 24v Z1 - HEATIG MODE 24V OUTPUT (W2 Y) ATI-IE TRO DESER Y AD X2 - WIRES TO ATI-IE TRO, DESIG UIT Y AD SIGA FROM H1 AD TO OMPETE SIGA 2 stage 2 Stage cooling ooling 3 Stage stage Heating heating Heatpump DESER heatpump 24v Z1 - HEATIG MODE 24V OUTPUT (W2 Y) ATI-IE TRO Y2 Y1 O/B R Y2 WIRE TO ATI-IE TRO TO ITERRUPT THE DESERS Y2 SIGA G W1 W2 R Y2 Y1 D O/B DRY TATS AD 115 VA REAY WIRIG Z1 H1 X2 AUXIIARY REAY (HEATIG) W1 W2 G R Y2 Y1 D O/B E W1 W2 G R Y THERMOSTAT AD - HEATIG MODE AUXIIARY TAT W1 AD W2 Y Z1 H1 X2 AUXIIARY REAY (HEATIG) W1 W2 G R Y2 Y1 D O/B E W3 G R Y2 Y1 O/B THERMOSTAT AD - HEATIG MODE AUXIIARY TAT W1 AD W2 Y FOR SIGE STAGE OPERATI USE W2 & Y2 TERMIAS R - 24VA OUTPUT W1 - FIRST STAGE HEAT W2 - SED STAGE HEAT (OR SIGE STAGE) Y1 - FIRST STAGE OOIG Y2 - SED STAGE OOIG (OR SIGE STAGE) - 24 VA OMM G - THERMOSTAT FA SWITH D - DEHUMIDIFIATI O/B - HEATPUMP REVERSIG VAVE - EUTRA - IE VOTAGE - AUXIIARY ORMAY OPE - AUXIIARY ORMAY OSED - AUXIIARY OMM - FREEZE STAT X2 - FREEZE STAT H1 - DESIG UIT 24V OUTPUT (Y) - 24 VA OMM Z1 - HEATIG MODE 24V OUTPUT - 24 VA OMM Energy Saving Products 12615-124 Street, Edmonton, AB T5-08 ESP315.07 Module HK - HV to HE onversion Kit Installation (6/10) -6-1995-2009 Energy Saving Products td.

HE Fan oil - 24V Wiring ontrols Module HK HV to HE onversion (7/10) W1 W2 G R Y2 Y1 W1 input to 1st (low stage) heat calls. Active when R is applied. Activates 1st stage heat fan and Auxiliary Relay. (W1 operates at 60% of W2 Fan Speed) W2 input to 2nd (high/primary stage) heat calls. Active when R is applied. Activates 2nd stage heat fan, Auxiliary Relay and 24V to Z1 (W2 operates at 200 FM per ton (94 /s), refer to dip setting) 24V supply common G input for thermostat fan switch. Active when R is applied (G operates at 50% of Y2 Fan Speed) 24V supply Y2 input to 2nd (high/primary stage) cooling or heat pump call. Active when R is applied. Activates 2 stage cooling fan speed, activates with 24V for freeze stat and condenser connections (Y2 operates at 250 FM per ton (118 /s), refer to dip setting) Y1 input to 1st (low stage) cooling or heat pump calls. Active when R is applied. Activates 1 stage cooling fan speed. (Y1 operates at 60% of Y2 Fan Speed) D 24V input required from dehumidistat switch activates blower system to 200 FM per ton (94 /s) from dip setting. Y2 must be activated from thermostat. (D operates at 200 FM per ton (94 /s), refer to dip setting) O/B Blind contact for condenser heat pump from thermostat X2 H1 Z1 24V Signal with calls from Y2, powers Freeze Stat Freeze Stat connection return signal 24V Signal to Y on ondenser ommon for ondensing Unit 24V supply on W2 call ommon *ote: to X2 recommended to be wired to Freeze Stat (Anti-Ice ontrol) If Freeze Stat is not used, a jumper between to X2 must be installed to complete the H1-24V Signal to Y on ondenser (i.e. hilled Water Systems) Module HK - HV to HE onversion Kit Installation (7/10) -7- v.03 1995-2009 Energy Saving Products td.

Module HK HV to HE onversion (8/10) EP ircuit Board Pin Settings and Air Flow Data (Standard) Model: HE-50 Model: HE-50 # Outlets 12 16 20 24 Model: HE-50 # Outlets 16 20 24 ooling: 1.5 Ton Mode Airflow in FM ooling: 2.0 Ton Mode Airflow in FM Heating: 32 MBH Hi ooling (Y2) 375 410 415 420 Heating: 40 MBH Hi ooling (Y2) 490 505 520 ESH: 5-10 kw o ooling (Y1) 225 245 250 255 ESH: 5-15 kw o ooling (Y1) 295 305 315 Dehumid (D) 300 300 260 280 Dehumid (D) 410 415 420 Hi Heating (W2) 340 355 340 360 Hi Heating (W2) 460 470 480 1 2 3 4 5 6 7 8 o Heating (W1) 275 280 260 270 1 2 3 4 5 6 7 8 o Heating (W1) 355 340 300 Pin Setting 0001-0100 onstant (G) 185 215 250 265 Pin Setting 0011-0100 onstant (G) 260 255 295 Model: HE-70 Model: HE-70 # Outlets 20 24 28 32 Model: HE-70 # Outlets 24 28 32 ooling: 2.5 Ton Mode Airflow in FM ooling: 3.0 Ton Mode Airflow in FM Heating: 51 MBH Hi ooling (Y2) 620 650 660 670 Heating: 58 MBH Hi ooling (Y2) 755 770 770 ESH: 5-18 kw o ooling (Y1) 375 390 400 405 ESH: 5-18 kw o ooling (Y1) 455 465 465 Dehumid (D) 510 525 530 520 Dehumid (D) 600 610 605 Hi Heating (W2) 570 600 610 605 Hi Heating (W2) 680 695 690 1 2 3 4 5 6 7 8 o Heating (W1) 445 460 460 440 1 2 3 4 5 6 7 8 o Heating (W1) 540 545 540 Pin Setting 0101-0100 onstant (G) 310 350 370 370 Pin Setting 0110-0100 onstant (G) 370 385 380 Model: HE-100 Model: HE-100 # Outlets 28 32 36 Model: HE-100 # Outlets 32 36 40 ooling: 3.5 Ton Mode Airflow in FM ooling: 4 Ton Mode Airflow in FM Heating: 72 MBH Hi ooling (Y2) 885 895 920 Heating: 80 MBH Hi ooling (Y2) 1000 1030 1030 ESH: 5-18 kw o ooling (Y1) 535 540 555 ESH: 5-20 kw o ooling (Y1) 600 620 620 Dehumid (D) 700 700 710 Dehumid (D) 800 820 800 Hi Heating (W2) 795 815 830 Hi Heating (W2) 905 930 915 1 2 3 4 5 6 7 8 o Heating (W1) 625 625 625 1 2 3 4 5 6 7 8 o Heating (W1) 720 735 710 Pin Setting 1000-0100 onstant (G) 520 440 465 Pin Setting 1010-0100 onstant (G) 495 505 490 Model: HE-100 # Outlets 36 40 44 48 ooling: 5.0 Ton Mode Airflow in FM Heating: 94 MBH Hi ooling (Y2) 1255 1250 1260 1260 ESH: 5-23 kw o ooling (Y1) 755 750 760 760 Dehumid (D) 1010 1005 1005 1000 Hi Heating (W2) 1120 1120 1120 1115 1 2 3 4 5 6 7 8 o Heating (W1) 920 900 900 890 Pin Setting 1100-0100 onstant (G) 670 635 635 625 Minimum of eight 2 (51mm) outlets per ton of cooling (HE Duct = Minimum four outlets per ton) ESH = Electrical Strip Heaters, minimum of 7 outlets per 5kW is required Black indicates dip switch position: OFF Module HK - HV to HE onversion Kit Installation (8/10) -8-1995-2009 Energy Saving Products td.

The extended pin settings show how to increase or decrease the required FM on the Hi-Velocity-HE fan coil for fine tuning. The chart illustrates the FM difference achieved changing pins 6, 7, and 8. Only these three pins are modified to increase or decrease the FM based upon the selected tonnage of pins 1 through 4. 1400 EP Dip Ranges & Extended Air Flow Adjustments EP Dip Ranges Module HK HV to HE onversion (9/10) 1300 1200 1100 FM output 1000 900 800 700 600 1.5 tons / 5.3 kw 2 tons / 7.0 kw 2.5 tons / 8.8 kw 3 tons / 10.6 kw 3.5 tons / 12.3 kw 4 tons / 14.1 kw 5 tons / 17.6 kw 500 400 300 200 0 1 2 3 4 5 6 dip setting Extended Air Flow Adjustments The extended pin setting applies to all HE fancoils and can be used to lower or raise FM output. Only PI s 6,7,8 are changed in order to modify the FM output Pin Setting Result 1. Decrease 6 7 8 2. 6 7 8 3. Ideal (default) 6 7 8 4. 5. 6 7 8 6 7 8 Black indicates DIP switch position Module HK - HV to HE onversion Kit Installation (9/10) -9- Increase 1995-2009 Energy Saving Products td.

Energy Saving Products td., established in 1983, manufactures the Hi-Velocity Systems TM product line for residential, commercial and multi-family markets. Our facilities house Administration, Sales, Design, Manufacturing, as well as Research & Development complete with an in-house test lab. Energy Saving Products prides itself on ustomer Service and provides design services and contractor support. For all of your Heating, ooling and Indoor Air Quality needs, the Hi-Velocity System is the right choice for you! Small Duct Heating, ooling and IAQ Systems Build Smart, Breathe Easy Hi-Velocity HE Fan oils, Green Technology HARDI Phone: 780-453-2093 Fax: 780-453-1932 Toll Free: 1-888-652-2219 www.hi velocity.com