FIRElux Emergency Lighting

Similar documents
APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

savings in installations savings in energy expenses saving the environment Green Life Cycle Emergency Light System

EMERGENCY LIGHTING SYSTEM

The EN54 Part 2 & 4 Fire System

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Intelligent 2 & 4 Loop Fire Alarm Control Panels

World Class Leaders in Fire Detection Since FIREscape. PRODUCTCATALOGUE Emergency Lighting Solutions

ZXSe Range Data Sheet

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Intelligent Single Loop Fire Alarm Control Panel

Solution F2. Fire Alarm Control Panels one step ahead.

A Guide To BS Understanding the selection, spacing and siting of detectors

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Microtherm Heat Stress WBGT

Fire and Smoke Control Systems

Wireless Fire & Security Solutions. Fire Product Showcase

FC700A Fire detection control unit

SI120 Guarto Easy I. Alarm system. Fire & Security Products

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System

Intelligent addressable fire alarm control panel

Addressable and Conventional Fire Protection

The EN54 Part 2, 4 and 13 Fire System

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

IFD-E Flame Detector User Manual

Sita200plus. 200detectors. Single loop analogue addressable System

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

DS7400Xi Addressable Control/ Communicator

IFD-E Flame Detector User Manual

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

NETWORK FIRE ALARM CONTROL PANEL. Features

Touchpoint Pro Flexible Gas Control System

Memcom Emergency Telephone

Advanced FireAlarm Panel 1-4Loop

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

Product Data Sheet. Remote Terminals. Features:

30.45 Electric Release PDRP-2001

FEC400 Series. Installation Manual

FireNET Plus Wiring Instructions

Intelligent Addressable Fire Alarm System

Installation Manual Premier 412/816/832. Issue 10

IQ8Control C Fire Alarm Panel

SMS GSM Alarm Messenger

Monitoring Solutions

Reliably Advanced Extinguishing Control

REPEATER FS5200R INSTRUCTION MANUAL

Saxon Range 1-8 Zone Convertional Control Panels

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

Danfoss gas detection units

Touch Screen 1 loop Addressable Fire Alarm Panel

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

CODESEC FIRE ALARM SYSTEMS. security technologies

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

METOS Compact SMS. The smooth change of a product. Gottfried Pessl

SOUNDER CONTROL MODULE SCM-AS4

ZITON RADIO LOOP MODULE

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Analogue Addressable Fire Panels FP1500. Manual for Installation, Configuration and Commissioning

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

Why Hart XL Aspirating Smoke Detection?

SALES SUPPORT DOCUMENT

Intelligent Security & Fire Ltd

PERMACONN PM1030 Includes DI300. Installation Manual

INTELLIGENT FIRE ALARM CONTROL PANEL

Excel-EN Conventional Fire Control Panel

IC60 Sintony 60 Intrusion Control Panel

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

SC-F3G User Manual 1.0

Wireless Fire & Security Solutions. Fire Product Showcase

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Sentient. Downloader Manual D4854

Solution F1. Fire Control Panels the new generation

Specification for On-Line UPS Battery Monitoring and Data Management System

DGC-1000 DIGITAL GENSET CONTROLLER

user manual Document No , Revision 03 November 2015

Multiview Monitor / Controller

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

Installation Manual. Premier 24. Issue 3

Danfoss gas detection units

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Different types of Fire Alarm System

Networked Access Control Panel. Installation Guide

Intrunet SPC series advanced security for a connected world

Installation Manual. Premier 640. Issue 1

Power Supply Display Module PSDM. Installation and Operation Manual

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj

Transcription:

ABC a FIRElux Emergency Lighting

Safety In All Enviroments FIRElux is a completely new emergency lighting system. The rapid development of LED technology has made it possible to implement emergency lighting systems utilising analogue system technology. Hochiki, using the world-proven ESP protocol, have combined the best of centralised and decentralised emergency lighting systems with their state-of the art fire detection technology simplifying cable-planning, loop technology and connections. FIRElux is based on an addressable emergency lighting control panel with battery back-up, addressable, self-contained luminaires and signage with traditional low-voltage cabling. FIRElux also offers the installer new solutions to the installation of luminaires, connections and service. The conventional methods of grouping luminaires in exit signs and route light groups have been surpassed. The addressability of the components makes it possible to locally control the fire areas and group control panels. For example the route lights and exit signs of a specific area can be progrgammed to remain on in alarm/fault situations. Advantages of the FIRElux System Simplified system planning Battery back-up contained in each luminaire/sign Will operate on loop length of between 500m to 1000m 127 addressable luminaires/signs per individual (dedicated) loop Inexpensive cabling costs - a dedicated lighting loop does not have to be fire-rated Easy installation, luminaires/signs fit onto standard Hochiki sensor mounting base - YBN-R/3 Easy service and maintenance Automatic testing System alarm data can be transmitted direct to a service company by transfer units Cost-effective system in implementation and maintenance

Products FIRElux-1 Emergency Lighting Control Panel FIRElux-2 Addressable Emergency Lighting Control Panel In normal situations the FIRElux-1 control panel supplies an operating voltage to the addressable luminaires/signs. In case of power failure the luminaires switch to internal batteries. Any failure in the luminaire is shown at the control panel. Luminaires: 60 pcs addressable route lights and exit signs Supply voltage: 29 VAC (150 VA) Nominal voltage: 12 VDC I/O outputs: 1 relay output Size (w x h x d): 270 x 350 x 84 mm The control panel FIRElux-2 has two addressable loops. Each loop can run 127 luminaires/signs. In normal conditions the FIRElux-2 supplies an operating voltage to the luminaires/signs whilst also monitoring the lighting system. All monitoring data is stored locally in the control panel memory and can be read using the LCD screen on the FIRElux-KP keypad. Luminaires: 254 addressable exit signs and route lights Supply voltage: 29 VAC (150 VA) Nominal voltage: 12 VDC Internal batteries: 7.2 Ah I/O outputs: 1 relay output and 7 digital outputs Modem connection: RS-232 Keypad connection: RS-485/9600 baud Transaction memory: 500 transactions Size (w x h x d): 295 x 475 x100 mm Designed for use with the FIRElux-2 control panel (max 8 pcs in the system) provides a small graphic display for system information. Nominal voltage: 12 VDC Display: graphic display 128 x 64 pixels Display viewing area: 60.0 x 32.5 mm Size: (w x h x d): 147 x 144 x 29 mm Intended for use with FIRElux-2 control panel FIRElux-KP Keypad Loop-controlled 230 V/500 W control panel, which provides power for the Addressable Firelux system. Switchmode power supply Terminal block connections for outputs, max. 2.5 mm 2 Outputs: 6 pcs, 2A glass tube fuses Batteries: 2 pcs 42 Ah / 1h safety time Control of emergency lights for each group as option FIRElux-PSU 230V Control Panel

System Structure FIRElux brings new technology with new opportunities and solutions for emergency exit lighting. The core of the FIRElux emergency lighting system is the addressable FIRElux-2 control panel. Altogether 254 exit signs and route lights can be connected to the two addressable loops. Both exit signs and route lights utilise LED (Light Emitting Diode) technology, which guarantees around 10 years lifetime (for exit sign usage). The unique Flex-it hinge system in the exit signs allows both wall and ceiling mounting utilising the standard Hochiki sensor mounting base, YBN-R/3. The equipment is controlled by the FIRElux-KP keypad which features an LCD graphic display. The keypad display can show the address and location text of the device in alarm or fault. Maintenance In the EN50172 standard regarding emergency lighting systems special attention has been paid to the operational condition of the system. The system has to be tested regularly - at least once a month. The control panel of the FIRElux system continuously controls and tests the condition of the system automatically. Fault/alarm data remains in the control panel memory and can be shown on the keypad display. Cabling Cabling of the FIRElux system is easily and quickly achieved using traditional cable. The system can be wired either as a loop or as a spur. Exit lights can be connected in parallel without grouping. FIRElux allows the connection of the cabling to luminaire bases before installing the light units.

GSM Remote control of the FIRElux-2 emergency lighting system is possible utilising the GSM alarm transfer unit. Fault data is easily transmitted to end user or service company GSM numbers. Each GSM number can be stored in an alarm ring so that each responsible person can be contacted in turn if any others are unavailable. Control Station FIRElux emergency lighting system alarm and fault data, can be linked to a graphics software package located in a control centre. The software depicts the plan view of the building indicating both alarms and faults states. By using the FIRElux INSTALL program it is possible to monitor the emergency lighting system from a central point.

FIRElux-20 Addressable Exit Sign FIRElux-40 Addressable Exit Sign LED-based addressable exit sign with flexible Flex-it hinge solution. Address unit and battery are located in the hinge cup. Colour: white Material: fire resistant ABS plastic Fire class: UL94 V-O Viewing distance: 20m Models: 20L (left), 20R (right), 20L/R (double-sided), 20D (down), 20D/D (double-sided) Operating time: 1 h/3 h Enclosure class: IP44 Size (w x d x d): 204 x 133 x 32mm Total depth (wallmounting) 71.3mm Total height (ceiling mounting) 191.5mm (+ 10mm base YBN R/3) LED-based addressable exit sign with flexible Flex-it hinge solution. Address unit and battery are located in the hinge cup. Colour: white Material: fire resistant ABS plastic Fire class: UL94 V-O Viewing distance: 40 m Models: 40L (left), 40R (right), 40L/R (double-sided), 40D (down), 40D/D (double-sided) Operating time: 1 h / 3 h Enclosure class: IP44 Size (w x h x d): 350 x 253 x 32 mm Total depth (wallmounting) 70.1 mm Total height (ceiling mounting) 336.4mm (+ 10mm base YBN R/3) FIRElux-ER Addressable Luminaire LED-based addressable luminaire. Address unit and battery are located in the luminaire cup. Colour: white Material: fire resistant ABS plastic Fire class: UL94 V-O Operating time: 1 h/3 h Enclosure class: IP 44 Size (Ø x h): 99.7 x 38mm (+ 10mm base YBN R/3) FIRElux-SL Addressable Step Luminaire LED-based addressable step luminaire. Material: fire resistant ABS plastic Colour: white Fire class: UL94 V-O Operating time: 1 h/3 h Enclosure class: IP44 Size (w x h x d): 80 x 80 x 12mm Surface-mounted emergency lighting start button. Size (w x h x d): 88 x 88 x 52mm FIRElux-SB Start Button

YBN-R/3 Luminaire Base A universal base for exit signs and route lights with connection points for loop cabling. The base does not include electronics or battery. Colour: white Material: fire resistant ABS plastic Fire class: UL94 V-O Contacts: stainless steel Enclosure class: IP44 Size (Ø x h): 100 x 10mm The FIRElux-10 I/O unit is powered directly from the emergency lighting loop and allows start buttons and phase monitors to be connected to the system. 4 inputs Size (w x h x d): 100 x 110 x 35mm FIRElux-10 I/O Unit FIRElux-GSM Alarm Transfer Unit GSM-based duplex alarm transfer/control unit with number identification to block outsider use. The unit includes power source and GSM antenna. Alarm messages and call numbers programmable as sms 3 inputs (digital and analog alarm) 3 outputs (relay output NO, 24 V/10 A) Size (w x h x d): 100 x 75 x 25 mm FIRElux-DMC-8 Modem Communicator A modem communicator which transfers fault/alarm data to security and service companies via chosen telephone network. SIA format Communicator with serial traffic connection to NEPTO-254 control panel 8 inputs Size (w x h x d): 170 x 95 x 20 mm FIRElux alarm and fault data can be linked to the graphics software which displays the building system in plan view showing alarm and fault locations. Compatible with Win2000, XP, NT Shows alarm/fault data in plan view directly on building layout Includes program protective module FIRElux Graphics Software 7 A voltage monitoring and protection unit. Auxiliary supply voltage 190 to 260 Vd.c. Various rated voltages, user adjustable Delay time 0.1 to 10sec, user adjustable Size (w x h x d): 35 x 90 x 58 FIRElux-PM Local Fuse Failure Monitor

HOCHIKI EUROPE (UK) LIMITED Grosvenor Road, Gillingham Business Park, Gillingham, Kent, England ME8 0SA Telephone: +44 (0)1634 260133 Facsimile: +44 (0)1634 260132 e-mail (Non UK): export@hochikieurope.com www.hochikieurope.com Quality System Certificate No. 164 Assessed to ISO9001 Environmental Management System Certificate No. EMS 286 Assessed to ISO 14001 : 1996 Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by Hochiki Europe (UK) Ltd. to be a complete and up-to-date description. AP113/ISS1/MAY09