CLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN 04.13.2017 1
MONTICELLO INTERIOR FINISHES PAINT MOULDING WALLS ACCENT DOORS DOOR TRIM/STAIRS LAMINATE RESTROOM CERAMIC WALL TILE LAMINATE SOLID SURFACE TOILET PARTITION RESTROOM FLOOR TILE RUBBER BASE VINYL COMPOSITION TILE LAMINATE ACOUSTICAL WALL PANELS CLASSROOM/ADMINISTRATION CARPET TILE ENTRANCE CARPET CORRIDOR VINYL TILE ACCENT ACCENT RUBBER STAIR TREAD & RISER 2
MONTICELLO FLOOR FINISH PLAN LOWER LEVEL 3
MONTICELLO FLOOR FINISH PLAN FIRST FLOOR 4
MONTICELLO FLOOR FINISH PLAN SECOND FLOOR 5
MONTICELLO NEW ACOUSTICAL CEILING MAIN ENTRANCE NEW LIGHT FIXTURE NEW LIGHT FIXTURES NEW INTERIOR SIGNAGE NEW PAINT ON BRICK NEW PAINT ON STAIR STRINGER & RAILING NEW RUBBER STAIR TREADS & RISERS SECURED VESTIBULE NEW ENTRANCE SECURITY OFFICE NEW ENTRANCE WALK-OFF CARPET PLAN EXISTING PROPOSED DESIGN 6
MONTICELLO ADMINISTRATION RECEPTION NEW ACOUSTICAL CEILING NEW LIGHT FIXTURES NEW SIGNAGE NEW RECEPTION DESK EXISTING NEW CARPET PLAN PROPOSED DESIGN 7
MONTICELLO STUDENT DINING NEW ACOUSTICAL CEILING NEW INTERIOR SIGNAGE NEW LIGHT FIXTURES NEW PAINT ON BRICK NEW VINYL TILE EXISTING LIGHT FIXTURE PLAN ACOUSTICAL WALL PANELS ACRYLIC SIGN T I G E R S PROPOSED WALL GRAPHIC PAINTED WALL GRAPHICS 8
MONTICELLO TYPICAL CLASSROOM FINISHES & EQUIPMENT HVAC NEW CARPET TILE NEW CO2 SENSOR INTERLOCKED WITH VAV SHUT OFF BOX P1 NEW ACOUSTICAL CEILING TILE NEW MARKER BOARD FOR PROJECTOR NEW WALL THERMOSTAT INTERLOCKED WITH INDIVIDUAL CLASSROOM WSHP NEW PAINT ON WALLS NEW VAV SHUT OFF BOX (ABOVE CEILING FOR NEUTRAL OA FROM THE DOAS) CLASSROOM 106 M-AC-1 TECHNOLOGY NEW WALL MOUNTED SHORT THROW PROJECTOR NEW WIRELESS ACCESS POINT NEW SUPPLY DIFFUSERS & RETURN GRILLES DUCTED TO/FROM THE INDIVIDUAL CLASSROOM WSHP NEW EXHAUST GRILLE BACK TO DOAS DT DT NEW CEILING MOUNTED PAGING SPEAKERS NEW PAGING CALL BUTTON POWER A2 8'-0" NEW CLOCK NEW VOICE/DATA FACEPLATES NEW A/V FACEPLATE FOR HOOK UPS TO PROJECTOR NEW GENERAL PURPOSE DUPLEX RECEPTACLES (4) NEW DUPLEX RECEPTACLE FOR PROJECTOR (1) NEW QUAD RECEPTACLE AT TEACHER LOCATION (1) DS LIGHTING NEW 2 X4 RECESSED LED FIXTURES FIRE ALARM NEW FIRE ALARM SPEAKER STROBE NEW TECHNOLOGY OCCUPANCY SENSORS NEW LOW VOLTAGE DIMMER SWITCH WITH TWO ZONES ALTERNATES REFLECTED CEILING PLAN ZONE A CONTROLS TEACHING WALL ZONE B CONTROLS REST OF LIGHTING NEW DAYLIGHT SENSOR BY THE WINDOWS ENERGY CODE REQUIREMENT FOR AUTOMATIC DAY LIGHTING CONTROL NEW TELEPHONE HANDSET NEW SOUND REINFORCEMENT SYSTEM INCLUDES SPEAKERS, AMPLIFIER MICROPHONES NEW QUAD RECEPTACLE FOR SOUND REINFORCEMENT LOCATED AT TEACHER DESK 9
MONTICELLO TYPICAL CLASSROOM ALL EXISTING VISUAL DISPLAY BOARDS ON THE PROJECTOR WALL WILL BE REMOVED. A NEW 8 FEET WIDE MARKER BOARD WILL BE PROVIDED TO PROJECT UPON. THE RENDERING ILLUSTRATES NEW FINISHES AND EQUIPMENT. THE FURNITURE IS NOT IN CONTRACT. THE EXISTING VISUAL DISPLAY BOARDS ARE NOT SHOWN. PLAN PROPOSED DESIGN 10
INTERIOR FINISHES PAINT MOULDING WALLS ACCENT DOORS DOOR TRIM/STAIRS LAMINATE RESTROOM CERAMIC WALL TILE LAMINATE SOLID SURFACE TOILET PARTITION RESTROOM FLOOR TILE RUBBER BASE VINYL COMPOSITION TILE LAMINATE ACOUSTICAL WALL PANELS CLASSROOM/ADMINISTRATION CARPET TILE ENTRANCE CARPET CORRIDOR VINYL TILE ACCENT ACCENT RUBBER STAIR TREAD & RISER 11
FLOOR FINISH PLAN LOWER LEVEL 12
FLOOR FINISH PLAN FIRST FLOOR AREA A 13
FLOOR FINISH PLAN FIRST FLOOR AREA B & C 14
FLOOR FINISH PLAN SECOND FLOOR AREA A 15
FLOOR FINISH PLAN SECOND FLOOR AREA B 16
MAIN ENTRANCE NEW ACOUSTICAL CEILING NEW LIGHT FIXTURES NEW INTERIOR SIGNAGE BEFORE NEW DISPLAY CASE NEW VINYL TILE PLAN EXISTING PROPOSED 17
ADMINISTRATION RECEPTION NEW WALL PAINT (WALLPAPER REMOVED) NEW ACOUSTICAL CEILING NEW LIGHT FIXTURES NEW SIGNAGE NEW RECEPTION DESK NEW CARPET EXISTING PLAN PROPOSED 18
STUDENT DINING NEW ACOUSTICAL CEILING NEW INTERIOR SIGNAGE NEW LIGHT FIXTURES NEW PAINT ON BRICK NEW VINYL TILE EXISTING PLAN PROPOSED PAINTED WALL GRAPHICS 19
TYPICAL CLASSROOM FINISHES & EQUIPMENT HVAC A2 11'-0" NEW CARPET TILE NEW ACOUSTICAL CEILING TILE NEW MARKER BOARD FOR PROJECTOR NEW CO2 SENSOR INTERLOCKED WITH VAV SHUT OFF BOX NEW WALL THERMOSTAT INTERLOCKED WITH INDIVIDUAL CLASSROOM WSHP NEW PAINT ON WALLS NEW VAV SHUT OFF BOX (ABOVE CEILING FOR NEUTRAL OA FROM THE DOAS) TECHNOLOGY NEW WALL MOUNTED SHORT THROW PROJECTOR NEW WIRELESS ACCESS POINT NEW SUPPLY DIFFUSERS & RETURN GRILLES DUCTED TO/FROM THE INDIVIDUAL CLASSROOM WSHP NEW EXHAUST GRILLE BACK TO DOAS NEW CEILING MOUNTED PAGING SPEAKERS CLASSROOM 109 M-AC-1 A2 9'-0" NEW PAGING CALL BUTTON NEW CLOCK NEW VOICE/DATA FACEPLATES NEW A/V FACEPLATE FOR HOOK UPS TO PROJECTOR POWER NEW GENERAL PURPOSE DUPLEX RECEPTACLES (4) NEW DUPLEX RECEPTACLE FOR PROJECTOR (1) NEW QUAD RECEPTACLE AT TEACHER LOCATION (1) P1 LIGHTING NEW 2 X4 RECESSED LED FIXTURES FIRE ALARM NEW FIRE ALARM SPEAKER STROBE NEW TECHNOLOGY OCCUPANCY SENSORS REFLECTED CEILING PLAN NEW LOW VOLTAGE DIMMER SWITCH WITH TWO ZONES ZONE A CONTROLS TEACHING WALL ZONE B CONTROLS REST OF LIGHTING NEW DAYLIGHT SENSOR BY THE WINDOWS ENERGY CODE REQUIREMENT FOR AUTOMATIC DAY LIGHTING CONTROL ALTERNATES NEW TELEPHONE HANDSET NEW SOUND REINFORCEMENT SYSTEM INCLUDES SPEAKERS, AMPLIFIER MICROPHONES NEW QUAD RECEPTACLE FOR SOUND REINFORCEMENT LOCATED AT TEACHER DESK 20
TYPICAL CLASSROOM ALL EXISTING VISUAL DISPLAY BOARDS ON THE PROJECTOR WALL WILL BE REMOVED. A NEW 8 FEET WIDE MARKER BOARD WILL BE PROVIDED TO PROJECT UPON. THE RENDERING ILLUSTRATES NEW FINISHES AND EQUIPMENT. THE FURNITURE IS NOT IN CONTRACT. THE EXISTING VISUAL DISPLAY BOARDS ARE NOT SHOWN. PLAN PROPOSED DESIGN 21