PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

Similar documents
Fire Alarm Cables. Features: Countdown. New Labeling System on box. Color Coded Boxes. Zone and Room Markings

Fire Alarm/Life Safety Cable 6

Honeywell Cable & Custom Electronics

Security & Control Cables

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Genesis. Series Low Voltage Cable. Honeywell Cable Catalog

SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM HARDWARE FIBER OPTIC SPECIAL APPLICATION CATALOG, VOL.

Home Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems.

NewGeneration Cables. BELDENCable TM

electronic wire pocket-picker edition 7/06 Low voltage electronic wire specialists

WIRE & CABLE. Wire & Cable... Wire Accessories...

Alarm & Security SOLUTIONS. Access Control Video Surveillance Fire Alarm Life Safety

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

WIRE & CABLE. Wire & Cable... Wire Accessories...

Fire Alarm Systems ARTICLE. Introduction to Article 760 Fire Alarm Systems. Part I. General

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Genesis Series Cable THE POWER OF CHOICE. Cables for Silent Knight

Addressable NAC Output Module D327A

Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety

Quick Reference Applications Guide

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

Multi-Core Fire Resistant Cable

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

Category 5 Premise Wire

Second Revision No. 601 NFPA [ Section No [Excluding

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure

IDP-Zone-6 Six Zone Interface Module

Flexible Power Cable DLO

Brand Portable Power Cord & Control Cable Solutions

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Sound and Paging Systems

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

Fire alarm system specification for multiple tenant retail buildings

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Print Specification. Publication. Instructions. Specific requirements. General requirements

SIGA-CC1 Single Input Signal Module Installation Sheet

Honeywell Cable. We ve got a cable for that!

SECTION INTRUSION DETECTION A. SCOPE OF WORK FOR DESIGNER AND CONSULTANTS

MMF Six Zone Interface Module

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

5. Identification products.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE

Belden Infinity C-TC+ Cables for Extreme Flexing

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Installation Guide. Tracer ZN523 Zone Controller BAS-SVN003-E4

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

SAS Security and Alarm Safety Cables

BELDEN LOW VOLTAGE COPPER CABLE PLENUM RATED

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

(800) 292- omnicable.com CABLE ACCESSORIES GUIDE

Caledonian Flame Retardant Coaxial Cables

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Thermal Devices, Inc. Mount Airy, Maryland USA Heating Cable. Cut to Length in Field

Belden. Intrusion Detection. Intrusion Detection. Multiconductor Shielded Plenum/Alarm Cable

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

CZ-6A Six Zone Interface Module

Comtran Cable. Hub-LINK Cables for Transit Applications

SP-1000X. Panic Device Power Controller Installation Guide. Rev

GE Total Lighting Control

DOOR MONITORING/DURESS SYSTEM

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016)

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Keywords: VEWFD; Smoke detection; Smoke production; In-situ testing.

Fire Alarm Cables WEST PENN WIRE

HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher

SECTION FIRE ALARM

SC-6 Six Supervised Control Module

System Accessories, LCD Annunciators

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

FreezGard. Self-regulating crankcase heater. Product Overview

CATEGORY 6A FTP RJ45 SOLUTION

SolderSleeve Shield Terminators

MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Texas Based UL Alarm System Monitoring. Alarm System Monitoring Up to 128 zones $34.95 per month 25.00% $26.22

F1202 TRACE HEATING. Road & Ramp

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

NEC 2017 Changes and Their Effect Upon the ICT Industry

Booster Power Supply Manual

Transcription:

PVC Stranded and Solid Conductors Listed as Misc. Wire PAIRED UNJACKETED Burglar alarm systems wiring; to sensors, control. BURGLAR ALARM 1. CONDUCTOR: Stranded copper conductors (1/c tinned + 1/c bare) typical. (7-wire construction). 2. INSULATION: Polyvinyl chloride (PVC). 3. COLOR CODE: Available: White, Brown or Clear. 4. STANDARDS: Listed misc. wires. 5. TEMPERATURE: 80 C 6. VOLTAGE: 300 Volts Insulation Nominal Anixter Paired Conductors Thickness O.D. Number AWG Strand No. IN IN 320-187-2202 22 7 x 30 1.025.160 320-187-2002 20 10 x 30 1.025.170 320-187-1902 19 Solid 1.025.170 320-187-1802 18 16 x 30 1.025.190 320-187-1602 16 19 x 29 1.025.205 Anixter Inc. 1999 10-1

PVC/PVC Stranded Conductors Burglar alarm cables. BURGLAR ALARM MULTI CONDUCTOR JACKETED 1. CONDUCTOR: Stranded bare copper. 2. INSULATION: Polyvinyl chloride (PVC). 3. OVERALL JACKET: Polyvinyl chloride (PVC). 4. TEMPERATURE: 60 C 5. VOLTAGE: 300 Volts Insulation Overall Jacket Nominal Anixter Conductor Size Thickness Thickness O.D. Number AWG Strand No. IN IN IN 314-010-2202 22 7 x 30 2.009.020.145 314-010-2203 22 7 x 30 3.009.020.145 314-010-2204 22 7 x 30 4.009.025.166 314-010-2206 22 7 x 30 6.009.025.185 314-010-2208 22 7 x 30 8.009.025.209 314-010-2210 22 7 x 30 10.009.028.231 314-010-2212 22 7 x 30 12.009.030.251 314-010-2004 20 7 x 28 4.010.025.190 314-010-1802 18 16 x 30 2.015.025.206 314-010-1803 18 16 x 30 3.015.025.220 314-010-1804 18 16 x 30 4.015.025.238 10-2 Anixter Inc. 1999

FIRE ALARM PVC Solid Conductor FPL, FPLR, FPLP, UL Listed PARALLEL (ZIP CORD) For use in power limited fire and burglar alarms and smoke detectors and security systems. 1. CONDUCTOR: Stranded bare copper. 2. INSULATION: Polyvinyl chloride (PVC) or PVC alloy. 3. STANDARDS: NEC FPL, FPLR or FPLP, UL listed. 4. TEMPERATURE: 20 C to 60 C, dry locations. Conductor Insulation Nominal Size Thickness O.D. Approximate Anixter Insulation Weight Lbs. Number AWG Rating Type IN IN 1000 Ft. 9C180206-03 18 FPL Red PVC.032.104 x.204 21 9C160206-03 16 FPL Red PVC.032.115 x.225 28 9C140206-03 14 FPL Red PVC.032.128 x.256 39 145788 18 FPLR Red PVC.032.104 x.204 21 145787 18 FPLP Red FRPVC.032.104 x.204 21 145782 16 FPLP Red FRPVC.032.115 x.225 28 Anixter Inc. 1999 10-3

PVC Solid Conductor FPLR, FPLP, UL Listed FIRE ALARM NONSHIELDED PLENUM AND NONPLENUM For use in power limited fire and burglar alarms and smoke detectors and security systems. FIRE ALARM 1. CONDUCTOR: Solid bare copper. 2. INSULATION: Polyvinyl chloride (PVC) or PVC or FRPVC alloy, red PVC or PVC alloy jacket. 3. OVERALL JACKET: PVC or FRPVC. 4. STANDARDS: NEC FPLR or FPLP, UL listed. 5. TEMPERATURE: 75 C Shielded also available Overall Conductor Number Insulation Jacket Nominal Approx. SIze of Insulation Thickness Thickness O.D. Wt. Lbs. Anixter Number AWG Conductors Rating Type IN IN IN 1000 Ft. FA-1202C-1-1N-XX 12 2 FPLR FRPVC.013.015.247 59.3 FA-1202C-1-2N-XX 12 2 FPLP PVC.011.015.239 60.6 FA-1402C-1-1N-XX 14 2 FPLR FRPVC.013.015.213 38.6 FA-1402C-1-2N-XX 14 2 FPLP PVC.011.015.205 39 FA-1403C-1-1N-XX 14 3 FPLR FRPVC.013.015.251 71.9 FA-1403C-1-2N-XX 14 3 FPLP PVC.011.015.241 74.4 FA-1602C-1-1N-XX 16 2 FPLR FRPVC.010.015.174 25.3 FA-1602C-1-2N-XX 16 2 FPLP PVC.010.015.174 27.5 FA-1604C-1-1N-XX 16 4 FPLR FRPVC.010.015.204 46.6 FA-1604C-1-2N-XX 16 4 FPLP PVC.010.015.204 48.1 FA-1802C-1-1N-XX 18 2 FPLR FRPVC.010.015.151 17.4 FA-1802C-1-2N-XX 18 2 FPLP PVC.010.015.151 18.2 FA-1804C-1-1N-XX 18 4 FPLR FRPVC.010.015.176 30.4 FA-1804C-1-2N-XX 18 4 FPLP PVC.010.015.176 31.6 FA-1806C-1N-XX 18 6 FPLR FRPVC.010.015.211 44.6 FA-1806C-2N-XX 18 6 FPLP PVC.010.015.211 46.2 FA-1808C-1N-XX 18 8 FPLR FRPVC.010.015.230 57.8 FA-1808C-2N-XX 18 8 FPLP PVC.010.015.230 59.8 FA-2204C-1N-XX 22 4 FPLR FRPVC.010.015.141 16.5 FA-2204C-2N-XX 22 4 FPLP PVC.009.015.136 15.8 10-4 Anixter Inc. 1999

FIRE ALARM PVC Solid Conductor FPL, UL Listed LOW CAPACITANCE (SHIELDED) For use in power limited fire and burglar alarms and smoke detectors and security systems. 1. CONDUCTOR: Solid bare copper. 2. INSULATION: Polyvinyl chloride (PVC), red PVC jacket. 3. OVERALL JACKET: Polyvinyl chloride (PVC). 4. COLOR CODE: Red, Black, Yellow, Blue. 5. SHIELD: Aluminum/Mylar with tinned copper drain wire. 6. STANDARDS: NEC FPL, UL listed. 7. CAPACITANCE: 25 30 pf/ft. 8. TEMPERATURE: 20 C to 60 C, dry locations. Overall Conductor Insulation Jacket Nominal Size Number Thickness Thickness O.D. Approx. Anixter of Insulation Wt. Lbs. Number AWG Conductors Rating Type IN IN IN 1000 Ft. 158367 18 2 FPL PVC.015.020.203 26 158356 18 3 FPL PVC.015.020.214 33 158354 18 4 FPL PVC.015.020.232 40 158346 16 2 FPL PVC.017.020.233 35 158366 14 2 FPL PVC.020.025.279 50 10-6 Anixter Inc. 1999

LOW VOLTAGE-SECURITY/ALARM PLENUM PVC Bare Copper Conductor UL Listed, UL NEC Type, CMP, CLZP For use in Broadcast, Sound/Audio applications as well as Intercom/P.A and Power Limited Controls. 1. CONDUCTOR: Bare Copper. 2. INSULATION: FRPVC. 3. OVERALL JACKET: FRPVC. 4. STANDARDS: UL Type CMP or CL2P, CMP: 22 16 AWG, CL2P: 14 12 AWG, NEC Article(s) 800, 725 5. TEMPERATURE: 75 C. Shielded also available FIRE ALARM Overall Conductor Number Insulation Jacket Nominal Approx. SIze of No. of Thickness Thickness O.D. Wt. Lbs. Anixter Number AWG Conductors Strands Rating IN IN IN 1000 Ft. AL-1202C-2-2N-01 12 2 19 CL2P.011.015.273 68.6 AL-1402C-2-2N-XX 14 2 19 CL2P.011.015.229 53.7 AL-1403C-2-2N-XX 14 3 19 CL2P.011.015.253 68.0 AL-1602C-2-2N-XX 16 2 19 CMP.009.015.185 33.4 AL-1603C-2-CN-XX 16 3 19 CMP.009.015.197 45.5 AL-1604C-2-2N-XX 16 4 19 CMP.009.015.215 55.3 AL-1802C-1-2N-XX 18 2 Solid CMP.009.015.153 21.8 AL-1802C-2-2N-XX 18 2 7 CMP.009.015.155 23.7 AL-1803C-2-2N-XX 18 3 7 CMP.009.015.175 29.9 AL-1804C-2-2N-XX 18 4 7 CMP.009.015.192 37.4 AL-1805C-2-2N-XX 18 5 7 CMP.009.015.211 45.5 AL-1806C-2-2N-XX 18 6 7 CMP.009.015.230 60.0 AL-1808C-2-2N-XX 18 8 7 CMP.009.015.252 64.4 AL-1809C-2-2N-XX 18 9 7 CMP.009.015.273 72.8 AL-2202C-2-2N-XX 22 2 7 CMP.009.015.131 16.5 Anixter Inc. 1999 10-7

LOW VOLTAGE-SECURITY/ALARM NONPLENUM PVC Bare Copper Conductor UL NEC Type, CMR, CL3R For use in Broadcast, Sound/Audio applications as well as Intercom/P.A and Power Limited Controls. 1. CONDUCTOR: Bare copper. 2. INSULATION: PVC. 3. OVERALL JACKET: PVC. 4. STANDARDS: UL NEC Type CMR or CL3R, CMR: 22 16 AWG, CLR: 14 12 AWG, NEC Article(s) 800, 725 5. TEMPERATURE: 75 C. Shielded also available FIRE ALARM Overall Conductor Number Insulation Jacket Nominal Approx. SIze of No. of Thickness Thickness O.D. Wt. Lbs. Anixter Number AWG Conductors Strands Rating IN IN IN 1000 Ft. AL-1202C-2-1N-XX 12 2 19 CL3R.014.015.270 68.0 AL-1203C-2-1N-XX 12 3 19 CL3R.014.015.284 82.6 AL-1402C-2-1N-XX 14 2 19 CL3R.014.015.238 40.2 AL-1403C-2-1N-XX 14 3 19 CL3R.014.015.249 58.1 AL-1404C-2-1N-XX 16 4 19 CL3R.014.015.276 74.6 AL-1602C-2-1N-XX 16 2 19 CMR.010.015.186 32.9 AL-1603C-2-1N-XX 16 4 19 CMR.010.015.193 35.7 AL-1604C-2-1N-XX 16 4 19 CMR.010.015.217 58.0 AL-1802C-1-1N-XX 18 2 Solid CMR.010.015.155 17.1 AL-1802C-2-1N-XX 18 2 7 CMR.010.015.165 17.1 AL-1803C-2-1N-XX 18 2 7 CMR.010.015.171 25.4 AL-1804C-2-1N-XX 18 4 7 CMR.010.015.188 32.3 AL-1805C-2-1N-XX 18 5 7 CMR.010.015.207 40.8 AL-1806C-2-1N-XX 18 6 7 CMR.010.015.226 52.7 AL-1808C-2-1N-XX 18 8 7 CMR.010.015.269 61.2 AL-2202C-2-1N-XX 22 2 7 CMR.010.015.130 11.5 10-8 Anixter Inc. 1999

HVAC ECHELON LONWORKS Interface cables for LonWorks chip. Anixter Conductor Size Number of Number AWG Pairs Shielding Usage 9D220150 22 1 Nonshielded Nonplenum 9F220154 22 1 Shielded Nonplenum 9D220250 22 2 Nonshielded Nonplenum 9F220254 22 2 Shielded Nonplenum 9H2201504 22 1 Nonshielded Plenum 9J2201544 22 1 Shielded Plenum 9H2202504 22 2 Nonshielded Plenum 9J2202544 22 2 Shielded Plenum Building control cables. HONEYWELL *K3600, AK3700 and AK3900 series cables are available upon request. Building control, alarm and sensor cables. JOHNSON CONTROLS *All riser and plenum rated fire alarm cables. *Metasys sensor and relay, N1 and N2 Bus cables. Anixter Inc. 1999 10-9

THERMOSTAT Low Voltage Solid Copper Multi Conductor PT, PBT, PJT For use with thermostatic controls in connection with heating and air-conditioning installations. Type PJT may also be used for bell and annunciator systems. 1. CONDUCTOR: Solid copper, color-coded thermoplastic insulation, conductors twisted. 2. OVERALL JACKET: Overall no jacket, or braid waxed jacket, or plastic jacket, as applicable. PT PLASTIC INSULATION NO OVERALL JACKET Conductor Size Nominal O.D. Approximate Anixter Number Weight Lbs. Number AWG of Conductors IN 1000 Ft. 6T-1802T 18 2.140 14 6T-1803T 18 3.145 21 6T-1804T 18 4.165 27 6T-1805T 18 5.185 33 6T-1806T 18 6.205 43 6T-1807T 18 7.205 49 6T-1808T 18 8.230 55 PTB PLASTIC INSULATION BRAID WAXED JACKET Conductor Size Nominal O.D. Approximate Anixter Number Weight Lbs. Number AWG of Conductors IN 1000 Ft. 6T-1802B 18 2.180 18 6T-1803B 18 3.195 24 6T-1804B 18 4.215 33 6T-1805B 18 5.235 40 6T-1806B 18 6.260 47 6T-1807B 18 7.260 56 6T-1808B 18 8.270 63 PJT PLASTIC INSULATION PLASTIC JACKET Approximate Conductor Size Nominal O.D. Anixter Number Weight Lbs. Number AWG of Conductors IN 1000 Ft. 6T-1802J 18 2.170 20 6T-1803J 18 3.175 28 6T-1804J 18 4.205 36 6T-1805J 18 5.225 42 6T-1806J 18 6.225 50 6T-1807J 18 7.240 56 6T-1808J 18 8.265 65 10-10 Anixter Inc. 1999