Certificate of Compliance

Similar documents
Certificate of Compliance

File E Vol. 1 Sec. 93 Page 1 Issued: and Report Revised:

Certificate of Compliance

CERTIFICATE. No. P Order No Page 1/2

Laptop Computer (OLPC)

Switching power supply. Additional Information on page 2 Input rating: Vac, 50-60Hz, 2.5A Output rating: 24Vdc, 8.33A max., 200W max.

EU Declaration of Conformity

CB TEST CERTIFICATE. Personal Computer. Acer Computer (Shanghai) Limited 3F, No. 168 Xizang Medium Road Huangpu District, Shanghai CHINA

Power Supply, Built-In DC/DC. XP POWER L L C SUITE E DYER RD SANTA ANA, CA United States

DC/DC Converter. ERICSSON AB FAROGATAN 6 STOCKHOLM, SE Sweden. ERICSSON AB FAROGATAN 6 STOCKHOLM, SE Sweden

Independent controlgears

Component Switching Power Supply. XP POWER L L C Suite E DYER RD Santa Ana, CA USA

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

Power Supply for building-in TH-10280, THAILAND. See page 2. 0 Additional Information on page 2

DIN Rail Power Supply. Refer to page 2. [8] Additional Information on page 2. Input: Vac; 12 A; 50-60Hz Output: 24 V de; 40 A

Amendment to Test Report

CERTIFICATE. No. P Order No Page 1/2

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

UL TEST REPORT AND PROCEDURE

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

EU Declaration of Conformity

Test Report issued under the responsibility of:

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

ERTIFICATE. No. P This Nemko Certificate replaces the Certificate issued 27 March 2003 due to an error in the Factory listing.

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

File E Project 97SC January 21, 1998 REPORT

Provläsningsexemplar / Preview TECHNICAL REPORT. Part 3-1: Conformity verification report for IEC :2001 General requirements

LED CONVERTER. Korea, Republic of SOLUM CO., LTD. Korea, Republic of. Additional information on page 2 OLU750P701U1U; OLU750P701U1A

File E90165 Vol. 2 Index Page 1 Issued: Revised: Construction United States Type Canadian Type Section

Certificate of Compliance

UL TEST REPORT AND PROCEDURE

Certificate of Compliance

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

Certificate of Compliance

UL TEST REPORT AND PROCEDURE

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

ISO INTERNATIONAL STANDARD

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

Certificate of Compliance

ENEC NO2187. Nemko hereby grants the following manufacturer as licensee the right to affix this ENEC mark on the product(s) specified below.

Certificate of Compliance

Regulatory Compliance Training for Non-Safety Engineers

Certificate of Compliance

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

EU Declaration of Conformity

Certification Supplement Manual

ISO INTERNATIONAL STANDARD. Footwear Test methods for accessories: Touch and close fasteners Peel strength before and after repeated closing

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

RAILWAY APPLICATIONS - ELECTROTECHNICAL EQUIPMENT FOR ROLLING STOCK PART 5: ELECTROTECHNICAL COMPONENTS RULES FOR HV FUSES (IEC :2003)

Certification Supplement Manual

ISO 7458 INTERNATIONAL STANDARD. Glass containers Internal pressure resistance Test methods

Certification Supplement Manual

English version. Precast concrete products - Full-scale testing requirements in standards on precast concrete products

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Flex resistance

International Product Compliance and Certifications. Product Safety Consulting, Inc.

AS/NZS IEC :2013

This document is a preview generated by EVS

AS/NZS :2016

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

CONVENTIONS CONCERNING ELECTRIC AND MAGNETIC CIRCUITS (IEC 60375:2003) IRISH STANDARD I.S. EN 60375:2003. Price Code

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

PETROLEUM AND NATURAL GAS

PHOTOVOLTAIC DEVICES -- PART 2:

IECEE OPERATIONAL DOCUMENT

Provläsningsexemplar / Preview TECHNICAL REPORT

Consumer Products Services Germany GmbH Türkheim Germany

This document is a preview generated by EVS

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Dean King Dean King November 16, 2012

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

ISO 505 INTERNATIONAL STANDARD. Conveyor belts Method for the determination of the tear propagation resistance of textile conveyor belts

ISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

SECONDARY CELLS AND BATTERIES

LED CONVERTER. Korea, Republic of SOLUM CO., LTD. Korea, Republic of. Additional information on page 2 OLU700P142U1A; OLU700P142U1U

ISO/TS TECHNICAL SPECIFICATION

ISO 2411 INTERNATIONAL STANDARD. Rubber- or plastics-coated fabrics Determination of coating adhesion

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Clothing for protection against infectious agents Test method for resistance to dry microbial penetration

ALARM SYSTEMS - INTRUSION AND

ILNAS-EN ISO :2005

UL TEST REPORT AND PROCEDURE

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Welding Acceptance inspection of electron beam welding machines Part 4: Measurement of welding speed

HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY PART 2-13: PARTICULAR REQUIREMENTS FOR DEEP FAT FRYERS, FRYING PANS AND SIMILAR

Test Report Iec En Household And Similar

ISO INTERNATIONAL STANDARD. Footwear Test methods for whole shoe Washability in a domestic washing machine

ISO INTERNATIONAL STANDARD. Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies

ISO INTERNATIONAL STANDARD. Acoustics Measurement of sound pressure level from service equipment in buildings Engineering method

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Tensile strength and elongation

EU Declaration of Conformity

EN ISO Welding coordination Tasks and responsibilities. Schweißaufsicht Aufgaben und Verantwortung (ISO 14731:2006)

ISO/TS TECHNICAL SPECIFICATION. Geotechnical investigation and testing Laboratory testing of soil Part 10: Direct shear tests

ELECTRICAL AND INSTRUMENTATION LOOP CHECK (IEC 62382:2006 (EQV)) IRISH STANDARD I.S. EN 62382:2007. Price Code

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Tensile strength and elongation

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Plastics piping systems for hot and cold water installations Crosslinked polyethylene (PE-X) Part 1: General

ISO INTERNATIONAL STANDARD. Geosynthetics Determination of friction characteristics Part 2: Inclined plane test

Transcription:

Certificate of Compliance Certificate: 70048036 Master Contract: 170351 Project: 70048036 Date Issued: 2015-09-29 Issued to: Bel Fuse Inc. 206 Van Vorst St Jersey City, New Jersey 07302 USA Attention: Editha S. Vergara The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Juan-Carlos Olivera Juan-Carlos Olivera, MSc. PRODUCTS CLASS 5311 11 - POWER SUPPLIES - Component Type (CSA 60950-1-07-2nd Ed) CLASS 5311 91 - POWER SUPPLIES - Component Type (UL 60950-1-2nd Ed) - Certified to U.S. Stds For details related to rating, size, configuration, etc. reference should be made to the CSA Certification Record or the descriptive report. AC/DC Switching Power Supply Unit, Models FXC6000-32, FXC6000-32-S, FXC6000-48, FXC6000-48-S, FXC7000-48, FXC7000-48-S, FXC7000-S303, FXP6000-32, FXP6000-32-S, FXP6000-48, FXP6000-48-S, FXP7000-48, FXP7000-48-S, FXP6000-S105, FXP6000-S108. Note: All models may be followed by suffix G, XXX, XXXG, SXXX, SXXXG where X can be any numbers or (custom configurations), denoting non-safety-critical options. DQD 507 Rev. 2012-05-22 Page 1

Certificate: 70048036 Project: 70048036 Master Contract: 170351 Date Issued: 2015-09-29 Electrical Ratings: Input Output (DC) Model V A/φ Hz V A FXP6000-48, FXP6000-48-S, FXC6000-48, FXC6000-48-S 200-240/380-480 3φ 25/13 50-60 48 125 FXP7000-48, FXP7000-48-S, FXC7000-48, FXC7000-48-S, 200-240/380-480 3φ 25/13 50-60 48 145 FXP6000-S108 FXP6000-32, FXP6000-32-S, FXC6000-32, FXC6000-32-S 200-240/380-480 3φ 25/13 50-60 32 175 FXP6000-S105 380-480 3φ 18 50-60 32 172 FXC7000-S303 200-240/380-480 3φ 25/13 50-60 53 110 APPLICABLE REQUIREMENTS CAN/CSA-C22.2 No 60950-1-07, +Am.1:2011 +Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014 Information Technology Equipment - Safety - Part 1: General Requirements CONDITIONS OF ACCEPTABILITY When installed in the end-use equipment, consideration shall be given to the following: 1. This component has been judged on the basis of the required spacings in the Standard for Safety of Information Technology Equipment, Including Electrical Business Equipment, CAN/CSA C22.2, No. 60950-1-07, Second Edition, + Am1 + Am2/ UL 60950-1-2014, Sub-Clause 2.10, which would cover the component itself if submitted for Listing. 2. The output circuit is SELV and hazardous energy level. 3. The terminals and connectors have not been evaluated for field wiring. Maximum size input wiring to terminal block for Model FXC6000-S105 is No. 10 AWG. 4. The power supply shall be properly bonded to the main protective earthing termination in the end product. 5. Magnetic devices (e.g., transformer, inductor) employ an Unlisted Component (OBJY3), Electrical Insulation System. See Report for designated Class. 6. The equipment has been evaluated for use in a Pollution Degree 2 environment. 7. A suitable Electrical and Fire enclosure shall be provided. DQD 507 Rev. 2012-05-22 Page 2

Certificate: 70048036 Project: 70048036 Master Contract: 170351 Date Issued: 2015-09-29 8. The measured leakage current exceeds 3.5 ma, protective earth connection is essential before connecting to supply. A label with similar wording shall be affixed adjacent to the equipment AC Mains Supply connection: WARNING: HIGH LEAKAGE CURRENT EARTH CONNECTION ESSENTIAL BEFORE CONNECTING SUPPLY. ATTENTION: HAUTE FUITE À LA TERRE CONNEXION ACTUELLE INDISPENSABLE AVANT DE CONNECTER L'ALIMENTATION 9. The connectors have not been evaluated for connection under load conditions (hot swappable). If the unit will be used in this manner, additional connector testing will be necessary. 10. The products were tested on a 30 A branch circuit. If used on a branch circuit greater than this, additional testing may be necessary. DQD 507 Rev. 2012-05-22 Page 3

Supplement to Certificate of Compliance Certificate: 70048036 Master Contract: 170351 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Project Date Description Product Certification History 70048036 2015-09-29 AC/DC Switching Power Supply Unit, ModelsFXC6000-32, FXC6000-32-S, FXC6000-48, FXC6000-48-S, FXC7000-48, FXC7000-48-S, FXC7000- S303, FXP6000-32, FXP6000-32-S, FXP6000-48, FXP6000-48-S, FXP7000-48, FXP7000-48-S, FXP6000-S105, FXP6000-S108. (C/US) (transferred from 173688-2264228 and upgraded to include Am2). DQD 507 Rev. 2012-05-22 Page 1

CERTIFICATE No. P15220573 Order No. 294984 Page 1 of 2 Product AC/DC Switching Power Supply Applicant Manufacturer Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA Factory (2) See page 2 Ratings 200-240 / 380-480 V~, 3-PE, 3W+PE, 25 / 13 A,50-60 Hz Trade mark Model / Type Ref. Principal characteristics A sample of the product was tested and found to be in conformity with Validity Additional information FXC6000-32, FXC6000-32-S, FXC6000-48, FXC6000-48-S, FXC7000-48, FXC7000-48-S, FXC7000-S303, FXP6000-32, FXP6000-32-S, FXP6000-48, FXP6000-48-S, FXP7000-48, FXP7000-48-S, FXP6000-S108 The models may be followed by suffix G, XXX, XXXG, SXXX, SXXXG where X can be any numbers or customer configurations, denoting non-safety critical options OFF EN 60950-1:2006;A11;A1;A12;A2 This certificate documents conformity with the standards shown, and also applies as license for use of Nemkos name and certification mark. The certificate and license is valid as long as the applicable conditions are complied with, and provided that any changes to the product are notified to Nemko for acceptance prior to implementation. New standards or amendments to the standards may imply that the product design must be updated and/or that re-testing and re-certification is necessary. Additional model(s) (1) See page 2 Compliance with requirements regarding building-in, protection against electric shock and Electromagnetic Compatibility (EMC) must be checked when the equipment is built-in a completed product or forms a part of a complete system. Date of issue 09-12-2015 Juan Z. Kleppenes Certification Department Nemko AS Gaustadalléen 30, P.O. Box 73 Blindern, 0314 Oslo, Norway TEL +47 22 96 03 30 FAX +47 22 96 05 50 EMAIL info@nemko.com ENTERPRISE NUMBER NO974404532 nemko.com

CERTIFICATE No. P15220573 Order No. 294984 Page 2 of 2 Additional model(s) Product AC/DC Switching Power Supply Pos. No 1 Model / Type Ref. FXP6000-S105 Trade mark (if different from page 1) Rating 380-480 V, 3-Ph, 3W+PE, 18 A, 50-60 Hz Principal characteristics The may be followed by suffix G, XXX, XXXG, SXXX, SXXXG where X can be any numbers or customer configurations, denoting non-safety critical options Factories BPS Asia Pacific Electronics (Shenzhen) Co., Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park, Guangming District Shenzhen 518108 China Bel Power Solutions, s.r.o. Areal ZTS 924 Dubnica nad Vahom 01841 Slovakia Date of issue 09-12-2015 Juan Z. Kleppenes Certification Department Nemko AS Gaustadalléen 30, P.O. Box 73 Blindern, 0314 Oslo, Norway TEL +47 22 96 03 30 FAX +47 22 96 05 50 EMAIL info@nemko.com ENTERPRISE NUMBER NO974404532 nemko.com

Ref. Certif. No. NO89760 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI DACCEPTATION MUTUELLE DE CERTIFICATS DESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE CERTIFICAT D'ESSAI OC Product Produit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l'usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la deuxième page Ratings and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) AC/DC Switching Power Supply Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA Additional information on page 2 380-480 V, 3-Ph, 3W+PE, 18 A, 50-60 Hz Type of Manufacturer s Testing Laboratories used Type de programme du laboratoire d essais constructeur Model / Type Ref. Ref. De type FXP6000-S105 Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire, peuvent être indiqués sur la deuxième page A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport dessais numéro de référence qui constitue partie de ce Certificat The model may be followed by suffix G, XXX, XXXG, SXXX, SXXXG where X can be any numbers or customer configurations, denoting non-safety critical options Additional information on page 2 IEC 60950-1(ed.2);am1;am2 294984 This CB Test Certificate is issued by the National Certification Body Ce Certificat dessai OC est établi par l'organisme National de Certification Gaustadalléen 30 NO-0373 Oslo, Norway Date: 09-12-2015 Signature: Juan Z. Kleppenes Certification Department Issued 2007-04 1/2

Ref. Certif. No. NO89760 BPS Asia Pacific Electronics (Shenzhen) Co., Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park, Guangming District Shenzhen 518108 China Bel Power Solutions, s.r.o. Areal ZTS 924 Dubnica nad Vahom 01841 Slovakia Gaustadalléen 30 NO-0373 Oslo, Norway Date: 09-12-2015 Signature: Juan Z. Kleppenes Certification Department Issued 2007-04 2/2

Ref. Certif. No. NO89761 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI DACCEPTATION MUTUELLE DE CERTIFICATS DESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE CERTIFICAT D'ESSAI OC Product Produit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l'usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la deuxième page Ratings and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) AC/DC Switching Power Supply Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA Additional information on page 2 200-240 / 380-480 V~, 3-PE, 3W+PE, 25 / 13 A,50-60 Hz Type of Manufacturer s Testing Laboratories used Type de programme du laboratoire d essais constructeur Model / Type Ref. Ref. De type FXC6000-32, FXC6000-32-S, FXC6000-48, FXC6000-48-S, FXC7000-48, FXC7000-48-S, FXC7000-S303, FXP6000-32, FXP6000-32-S, FXP6000-48, FXP6000-48-S, FXP7000-48, FXP7000-48-S, FXP6000- S108 Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire, peuvent être indiqués sur la deuxième page A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport dessais numéro de référence qui constitue partie de ce Certificat The models may be followed by suffix G, XXX, XXXG, SXXX, SXXXG where X can be any numbers or customer configurations, denoting nonsafety critical options Additional information on page 2 IEC 60950-1(ed.2);am1;am2 294984 This CB Test Certificate is issued by the National Certification Body Ce Certificat dessai OC est établi par l'organisme National de Certification Gaustadalléen 30 NO-0373 Oslo, Norway Date: 09-12-2015 Signature: Juan Z. Kleppenes Certification Department Issued 2007-04 1/2

Ref. Certif. No. NO89761 BPS Asia Pacific Electronics (Shenzhen) Co., Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park, Guangming District Shenzhen 518108 China Bel Power Solutions, s.r.o. Areal ZTS 924 Dubnica nad Vahom 01841 Slovakia Gaustadalléen 30 NO-0373 Oslo, Norway Date: 09-12-2015 Signature: Juan Z. Kleppenes Certification Department Issued 2007-04 2/2

Test Report issued under the responsibility of www.nemko.com IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 294984 Date of issue... : 08 December 2015 Total number of pages... 53 Applicant s name... : Bel Fuse Inc. Address... : 206 Van Vorst St., Jersey City, NJ 07302, USA Test specification: Standard... : IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013 Test procedure... : CB-Scheme Non-standard test method... : N/A Test Report Form No.... : IEC60950_1F Test Report Form(s) Originator... : SGS Fimko Ltd Master TRF... : Dated 2014-02 Copyright 2014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report. This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.

Page 2 of 54 Report No 294984 Test item description... : AC/DC Switching Power Supply Trade Mark... : Manufacturer... : Same as Applicant Model/Type reference...: FXC6000-32, FXC6000-32-S, FXC6000-48, FXC6000-48-S, FXC7000-48, FXC7000-48-S, FXC7000-S303 FXP6000-32, FXP6000-32-S, FXP6000-48, FXP6000-48-S, FXP7000-48, FXP7000-48-S, FXP6000-S108, FXP6000-S105 (All models may be followed by suffix G, XXX, XXXG, SXXX, SXXXG where X can be any numbers or (custom configurations), denoting non-safety-critical options) Ratings...: All except below: 200-240 / 380-480 V~, 3-PE, 3W+PE, 25 / 13 A, 50-60 Hz FXP6000-S105: 380-480 V, 3-Ph, 3W+PE, 18 A, 50-60 Hz Testing procedure and testing location: CB Testing Laboratory: Nemko USA Inc. Testing location/ address... : 2210 Faraday Ave. Suite 150, Carlsbad, CA 92008, USA Associated CB Testing Laboratory: Testing location/ address... : Tested by (name + signature)... : Efrain Gonzalez Approved by (+ signature)... : Jeff Busch Report History: Original report List of Attachments (including a total number of pages in each attachment): Attachment 1: European Group Differences and National Deviations... 83 pages Documented deviations contain individual national documents for several European countries that are included in the European Group Deviations. The European Group Difference: EN60950:2006/A11:2009/A:2010/A12:2011/A2:2013 are considered Normative. The individual national documents (Denmark, Finland, Germany, Ireland, Norway, Spain, Sweden, Switzerland and United Kingdom) are considered informative and included at the manufacturer s request. Attachment 2: Miscellaneous Documentation, e.g. Photos, PWB Layout, Schematic etc.... 53 pages (Not for publication Engineering use only) TRF No. IEC60950_1F

Page 3 of 54 Report No 294984 Summary of testing General Power supply All comments relate to all models, unless specifically stated. The equipment is an enclosed, Class I switch mode power supply with universal AC input and single DC voltage outputs for building-in. This report covers multiple models and all comments / tests apply to all models unless otherwise indicated. Testing was conducted on Interchangeable models as indicated. 1.5, 3.2.5; Power supply cord set. A power supply cord set is not provided with the power supply. A power supply cord set, complying with the national regulations of the country in which the product is to be sold, shall be provided with the end-use equipment. 1.7.2; Safety instructions. Instructions and equipment markings related to safety are to be provided in a language, which is acceptable in the country in which the equipment is to be sold. English language verified. 1.7.2.4; IT power distribution systems. The equipment complies with the requirements for connection to the Norwegian IT power systems. The following information should be given (but is not required) in the installation instruction: This product is also designed for IT power system with Phase to Phase voltage 230V. 2.7.4; Number and location of protective devices. In Norway, IT power distribution system is used. Equipment with a single protective device is accepted in Norway. Other countries may have additional requirements. 2.7.6; Warning to service personnel. After operation of the protective device, the equipment is still under voltage if it is connected to an IT-power system. A warning is required for service personnel. Norway does not require this warning. 5.2: Electric Strength test Increased test voltages for Basic insulation applied to the equipment, based on measured working voltages. TRF No. IEC60950_1F

Page 4 of 54 Report No 294984 Summary of testing: 1) Input Test... 1.6.2 2) Durability Test... 1.17.11 3) Capacitance Discharge Test... 2.1.1.7 4) SELV Reliability Test... 2.2 5) Protective Bonding Test... 2.6.3.4 6) Humidity Test... 2.9.2 7) Working Voltage Measurement... 2.10.2 8) Hazardous Voltage Measurement... 2.10.2 9) Heating Test... 4.5.1 10) Touch Current Test... 5.1 11) Electric Strength Test... 5.2.2 12) Component Failure Test... 5.3 13) Abnormal Operation Test... 5.3 14) PS Output Overload and Short Test... 5.3 Testing location: See page 2 Summary of compliance with National Differences: List of countries addressed Austria (AT), Australia (AU), Canada (CA), China (CH), Denmark (DK), Finland (FI), Germany (DE), Ireland (IE), Israel (IS), Korea (KR), Norway (NO), Slovenia (SI), Spain (ES), Sweden (SE), Switzerland (CH), United Kingdom (GB), United States of America (US) The product fulfils the requirements of : EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 TRF No. IEC60950_1F

Page 5 of 54 Report No 294984 Copy of marking plate: The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective Certification Bodies that own these marks. calibration Measurement uncertainty Evaluation of result All instruments used in the tests given in this test report are calibrated and traceable to national or international standards. Further information about traceability will be given on request. Measurement uncertainties are calculated for all instruments and instrument set-ups given in this report. Calculation are based in the principles given in the standard EZ-4/02 (Dec.1999), IEC Guide 155:2007, Nemko routine L227 and other relevant internal Nemko-procedures. Further information about measurement uncertainties will be given on request. If not explicitly stated otherwise in the standard, the test is passed if the measured value is equal to or below (above) the limit line, regardless of the measurement uncertainty. If the measured value is above (below) the limit line, the test is not passed-ref IEC Guide 115:2007, and Nemko routine L220. The instrumentation accuracy is within limits agreed by IECEE-CTL (ref. Nemko routine L227) TRF No. IEC60950_1F

Page 6 of 54 Report No 294984 Test item particulars: Equipment mobility... : [] movable [] hand-held [] transportable [] stationary [ X ] for building-in [] direct plug-in Connection to the mains... : [] pluggable equipment [] type A [ X ] type B [] permanent connection [] detachable power supply cord [] non-detachable power supply cord [] not directly connected to the mains Operating condition... : [ X ] continuous [] rated operating / resting time: Access location... : [] operator accessible [] restricted access location Over voltage category (OVC)... : [] OVC I [ X ] OVC II [] OVC III [] OVC IV [] other: Mains supply tolerance (%) or absolute mains supply values... : -10% / +10% Tested for IT power systems... : [ X ] Yes (Norway only) [] No IT testing, phase-phase voltage (V)... : 230 V Class of equipment... : [ X ] Class I [] Class II [] Class III [] Not classified Considered current rating of protective device as part of the building installation (A)... : 30 A Pollution degree (PD)... : [] PD 1 [ X ] PD 2 [] PD 3 IP protection class... : IPX0 Altitude during operation (m)... : 2000 m Altitude of test laboratory (m)... : 38 m Mass of equipment (kg)... : 13 Kg Temperature, Ambient ( C)...: 50 C Possible test case verdicts: - test case does not apply to the test object...: N/A - test object does meet the requirement... : P (Pass) - test object does not meet the requirement...: F (Fail) Testing... : Date of receipt of test item... : September 2015 Date (s) of performance of tests... : October 2015 General remarks: "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. TRF No. IEC60950_1F

Page 7 of 54 Report No 294984 Manufacturer s Declaration per sub-clause 6.2.5 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided. : Yes Not applicable When differences exist; they shall be identified in the General product information section. Name and address of factory (ies)... : Bel Power Solutions s.r.o. ArealZTS Dubnica n.vahom c.924 01841 Dubnica nad Vahom SLOVAKIA BPS Asia Pacific Electronics (Shenzhen) Co.,Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park Guangming District 518108 Shenzhen PEOPLE'S REPUBLIC OF CHINA General product information: This test report is based on a TUV SUD test report Ref. No. SI1200012138-000 with appended CB cert Ref. No. DE 3-59814. This test report includes addition evaluation of the power supply to the requirements of IT power systems and an engineering evaluation of the Leakage at the output of the PSU. For continuity, data from the original TUV report is included in this report, along with the additional evaluation referenced. The subject models are component type, switching power supplies for building-in. Provided with metal enclosure, fan, input and output connectors. The output is floating with respect to chassis and can be used as a positive or negative polarity supply. The output is considered SELV and at hazardous energy level. Model Differences: Model FXC7000-48 is similar to model FXC6000-48 except for the maximum output power, input/output current ratings, fan and fuses ratings (input and OHB-1/OHB2). FXP6000-32 and FXC6000-32 are similar to model FXP6000-S105 except for the maximum output power, input/output current ratings and model FXP6000-32 is panel mounted. Model FXC7000-S303 is exactly the same as FXC7000-48 except for the output rating and values of some SELV resistors. Models with -S are exactly the same as models without -S except for the cover of the Voltage Select Jumper Connectors. TRF No. IEC60950_1F

Page 8 of 54 Report No 294984 Additional Electrical Ratings: Model Input (3-Phase) Output Vac A Hz Vdc A FXC6000-32, FXC6000-32-S FXP6000-32, FXP6000-32-S FXC6000-48, FXC6000-48-S FXP6000-48, FXP6000-48-S 200-240 / 380-480 25 / 13 50-60 32 175 200-240 / 380-480 25 / 13 50-60 32 175 200-240 / 380-480 25 / 13 50-60 48 125 200-240 / 380-480 25 / 13 50-60 48 125 FXP6000-S105 380-480 18 50-60 32 172 FXP6000-S108 200-240 / 380-480 25 / 13 50-60 48 145 FXC7000-48, FXC7000-48-S FXP7000-48, FXP7000-48-S 200-240 / 380-480 25 / 13 50-60 48 145 200-240 / 380-480 25 / 13 50-60 48 145 FXC7000-S303 200-240 / 380-480 25 / 13 50-60 53 110 Note: All models may be followed by suffix G, XXX, XXXG, SXXX, SXXXG where X can be any numbers or custom configurations, denoting non-safety-critical options. CONDITIONS OF ACCEPTABILITY: When installed in the end use equipment, the following are among the consideration to be made: 1) A suitable fire enclosure at end use. 2) A reliable ground (Protective Earth) connection at end use. 3) Maximum operating ambient of 50 C Abbreviations used in the report: - normal conditions... N.C. - single fault conditions... S.F.C - functional insulation... OP - basic insulation... BI - double insulation... DI - supplementary insulation... SI - between parts of opposite polarity... BOP - reinforced insulation... RI Indicate used abbreviations (if any):... None TRF No. IEC60950_1F