FEEDWATER TANK WITH DEAERATOR DATASHEET. Capacity 1000 to lt Operating Pressure 0,5 bar

Similar documents
Condensate Recovery and Return System SDR A

.005 ATMOSPHERIC DEAERATOR

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

DEAERATORS .005 ATMOSPHERIC DEAERATOR

Product overview. the optimum components for every application

BuildingName The Description of the Project P DOCUMENTS

.03 ATMOSPHERIC DEAERATOR

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

BOILER HOUSE PRODUCTS GMS

GESTRA. Product Overview. The optimum components for every application

Silhouette. Feedwater Heater. Boiler Feedwater

GESTRA. Product Overview. The optimum components for every application

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Open System Condensate receiver tank of cylindrical. design type SDR A with highpressure

Technical Specification

Condensate Recovery and Return System SDR A

Deaerator. Specifications

Electrode Boilers Model CEJS Steam

Flash Condensing De-aerator Heads Installation and Maintenance Instructions

Water Fuel + Air for combustion Blowdown

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

Centrifugal Blowdown Separators and Tanks

Technical Specification

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

Diocese of Cleveland Facilities Services Corporation

Deaerators for Industrial Applications

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

100 years of boiler technology leadership.

SECTION HEATING BOILER FEEDWATER EQUIPMENT

Technical Specification

STEAM VALVE SUPPLY & SYSTEM DESIGN

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

Technical Specification

FUEL-FIRED VERTICAL TUBELESS BOILERS

Adca Training. Part 2

CRU-S Series Stainless Steel Condensate Recovery Unit

Technical Specification

Boiler Basics. Design and operation

Protective Chemistry for Steam Boiler Wet Layup posted to DPS client area on:

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

Fuel-Fired Vertical Tubeless Boilers

Technical Specification

ADAC. Advanced Deaerator Control

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h

SECTION BOILER PLANT MECHANICAL EQUIPMENT

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology

Raffaello From serial number Group

Document Code: 1 (15) Issuing date: Status:

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

MX RANGE PACKAGED STEAM BOILERS

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

Jenroll EXPress Optimized evaporation capacity for integrated finishing lines

Clean Steam Generators

Removal of Non-condensable Gases and Air Is Critical In A Steam System

Series 300 VTB. Installation Instructions

SECTION DOMESTIC WATER HEATERS

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Element D Services Heating, Ventilating, and Air Conditioning

Top performance when the going gets tough

Custom Design TYPE CS

Rental Boiler Specifications (Nebraska Boiler)

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

GRUNDFOS IndustrY ENGINEERING MANUAL. Industrial Boilers

Boiler Mountings. Engr. Omar Sadath, Maritme Lecturer & Trainer, Bangladesh

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

WELCOME TO THE AWT REGIONAL TRAINING PROGRAM

Water Safety Shut-Off Valve HON 790. Product information. serving the gas industry worldwide

Aldrich Blowdown Separators & Cooling Manifolds

Information on selection of an economizer, and resulting payback due to changes in inlet water temperature.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Company History. The Deaerating Principle. Undeaerated Water Non-Condensibles (Vented) Steam Deaerated Water

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

OPERATING AND MAINTENANCE MANUAL FOR VERTICAL IMMERSION HEATED STEAM BOILERS. Technical Control Systems Limited MODELS "VIHS"

TYPE.005 DA-2C. Deaerating Boiler Feed Pumps. SHIPCO Deaerators can save you money!!! BULLETIN 149 Revised 8/09

Efficient Steam System Design

Derox - Cold and Hot Water Deaeration Improve your beer quality with the Derox Deaerator

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Installation, Operation, and Maintenance. For. Stickle Series AIV Spray-Tray Type Deaerating Feedwater Heaters. Introduction

SCHNEIDER-KESSEL BERLIN

HCLEARFIRE. High-efficiency, modular steam boiler HP

Math & Physics. Complete combustion requires an Air-FuelRatio of 14.7 to 1 for combustion.

3.1 Deaerator Systems

Solution builder. in energy management.

Water treatment made easy! Evaporators for the treatment of industrial wastewater.

Instruction Manual STR MODEL RESISTO-FLO ELECTRIC BOILER

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL

Presented by Moises Rodriguez Cleaver Brooks Sales & Service, Inc.

Water Treatment Improves Your Bottom Line DAVE PICOU WATER CARE SERVICES DIVISION JOHN SCHULTZ TEXTILE CARE DIVISON

SAMPLE SPECIFICATIONS

Transcription:

DATASHEET FEEDWATER TANK WITH DEAERATOR Capacity 1000 to 20000 lt Operating Pressure 0,5 bar Steam boiler feedwater tank with stainless steel Deaerator Oxygen Removal - Water Preheating and Storage DSEN001-01

Feedwater tank with deaerator (with optional equipment shown) Page 2

Features at a glance Horizontal feedwater tank, of welded construction with domed ends Tank made of carbon steel (S235JRG2) Stainless steel deaerator Pressure controlled process Condensate makeup water mixture preheating Undissolved gases vent Automatic operation Perforated baffle type counter flow deaerator Precise pressure control Sample cooler (optional) for water analysis Easy maintenance and inspection via manholes and access platforms Reputable and worldwide accepted safety equipment Wide selection of optional extras High degree of automation and integration into SCADA systems through available PLC units Range Series Description Volume lt Operating pressure bar DEA Steam boiler Feedwater Tank with stainless steel Deaerator 1000 20000 0,5 Page 3

Equipment - Connections C1. Safety valve C2. Vacuum breaker C3. Safety probe C4. Condensate inlet C5. Pressure gauge C6. Operation pressure transmitter C7. Vent C8. Makeup water inlet group C9. Heating steam inlet group C10. Overflow C11. Blowdown valve C12. Feedwater valve C13. Level indicator, level control C14. Temperature gauge C15. Chemical injection C16. Electrical panel C17. Feedwater pumps C18. Feedwater pump filter C19. Feedwater pump inlet valve C20. Pressure gauge C21. Feedwater pump check valve C22. Feedwater pump outlet valve C23. Sample cooler N1. Spare connection N2. Spare connection N3. Manhole N4. Working platform N5. Lifting lug E1. Feedwater tank E2. Base frame E3. Deaerator Type 1000 2000 3000 5000 7500 10000 13000 16000 20000 Connection Steam inlet group (C9) DN 25 25 32 32 40 50 65 65 80 Water inlet group (C8) DN 25 25 25 32 32 40 40 50 50 Feedwater stop valve (C12) DN 50 50 65 65 80 80 100 100 125 Condensate inlet (C4) DN 65 80 80 100 100 125 150 150 200 Safety valve (C1) DN 32 40 40 50 50 65 80 80 100 Blowdown valve (C11) DN 40 40 50 50 50 50 50 65 65 Overflow (C10) DN 20 20 25 25 25 25 32 50 50 Vent (C7) DN 20 20 20 20 20 20 20 20 20 Page 4

Dimensions Type 1000 2000 3000 5000 7500 10000 13000 16000 20000 General Dimensions Length (L1) mm 1900 2400 2400 2900 3400 4400 4400 4400 4900 Width (W1) mm 1250 1500 1700 1900 2100 2150 2350 2550 2700 Height (H1) mm 2850 3100 3500 3700 3900 3950 4150 4550 4700 Tank Base Width (W2) mm 750 1000 1200 1400 1600 1450 1650 1650 1800 Tank Base Length (L2) mm 1200 1700 1700 2100 2600 3500 3500 3500 4000 Total Height (H2) mm 4850 5100 5500 5700 5900 5950 6150 6550 6700 Base Frame Base frame Width (W3) mm 1650 1900 2100 2300 2500 2550 2750 2950 3100 Base frame Length (L3) mm 1300 1800 1800 2200 2700 3600 3600 3600 4100 Total Height (H3) mm 2000 2000 2000 2000 2000 2000 2000 2000 2000 Transport Weight 1 ( without equipment ) kg 990 1250 1580 1960 2410 3660 4230 4810 6540 1 Transport weight may differ from the indicated Page 5

Designation Type selection Series Size (Tank Capacity in lt) DEA - 5000 1000 2000 3000 5000 DEA 7500 10000 13000 16000 20000 Standard delivery - Thermal deaerator manufactured according to AD 2000 with CE mark complying to PED, with all necessary flanged connections, working platform with ladder, strong insulation with aluminum cladding, lifting lugs - Water level indicator - Pressure gauge - Control panel - Automatic water level control - 1 st water Low level alarm - 2 nd water Low level alarm - Temperature gauge - Vacuum breaker - Pump stop valve - Safety valve - Blow down valve - Steam inlet group - Water inlet group - Operation pressure transmitter Optional Extras PROODOS INDUSTRIAL BOILERS offers a wide range of optional equipment for the Thermal Deaerators. Find below the available options - Feed water pumps - Sample cooler - Base frame For more details and specifications please contact your Local Agent. Page 6

Minimum water characteristics For long lasting deaerator operation PROODOS recommends that water level characteristics are according to EN 12953-11 and should always be followed and maintained throughout operation. Always consult a water specialist for professional advice. Warranty All PROODOS thermal deaerators are granted with a 18 months FoB factory warranty, in which period all pressure parts found defected (in workmanship or materials) will be repaired free of charge. Note that the steam boiler should be operated, maintained and serviced according to Operator s Manual of Operation. Warranty does not cover damages caused by bad water conditions, rust, improper use, or electrical faults. Certain exclusions apply PROODOS INDUSTRIAL BOILERS LTD Kalohori Industrial Area PO BOX 1054, 57009 Thessaloniki, Greece Telephone +30.2310.751.257 Fax +30.2310.751.257 Email info@proodosboilers.com Web www.proodosboilers.com Page 7