CABLES FOR ALARM AND SAFETY SYSTEMS

Similar documents
Caledonian Flame Retardant Coaxial Cables

Multi-Core Fire Resistant Cable

PRODUCT CATALOGUE Norröna

Caledonian Fire resistant Coaxial Cables

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

NewGeneration Cables. BELDENCable TM

SAS Security and Alarm Safety Cables

Caledonian fire Resistant signal & Data cables

Compact Module. Category 6A FTP Cabling System 1.1

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Cables and cabling solutions for residential buildings: safety, comfort and environmental-friendliness

CATEGORY 6A FTP RJ45 SOLUTION

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Catalogue Telecommunication Cables INTRODUCCIÓN

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Cables and cabling solutions for public and office buildings: safety, comfort and environmental-friendliness

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

The Quality Connection. BETAflam Fire Resistant Safety Cables

FIRE RESISTANT CABLES

Shipboard & Offshore Cables

High Performance LSZH Fire Resistant Cable

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Sensor and transducer cables

Fire Alarm/Life Safety Cable 6

Telecommunication Cables

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

TYPE APPROVAL CERTIFICATE

Havells Fire Survival Cables

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

fire resistant cables

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Catalogue. Instrumentation & Control Cables

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Heat Sensor Cable Alarm Units DT650L / DT950L

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION

WIRE & CABLE. Wire & Cable... Wire Accessories...

WIRE & CABLE. Wire & Cable... Wire Accessories...

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

SPECIAL ELECTRICAL AND OPTICAL CABLES

Tether and Umbilical Cables for Remotely Operated Vehicles

ADVANCED 247 Link Walk, Eastfield, Scarborough, YO11 3LR. 24 Hour Line:

BS /1000V XLPE Insulation LSZH Sheath Cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Techno Machines India

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

HELKAMA. Optical Fibre Cables

Wire and Cable The Industry Standard for Rugged, Reliable Performance

Traction Cable Radox 3 GKW

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Catalogue Power Cables

Photovoltaic Cables EN H1Z2Z2-K

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Belden Infinity C-TC+ Cables for Extreme Flexing

Lloyd s Register Type Approval System Test Specification Number 3

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Introduction.

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

(Notices) EUROPEAN COMMISSION

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

Tether and Umbilical Cables for Remotely Operated Vehicles

Üntel is ready for CPR

DNVGL-CP-0401 Edition February 2016

Firecel Safety Cables

Security & Control Cables

THE TRUE FIRE SURVIVAL CABLE

Comtran Cable. Hub-LINK Cables for Transit Applications

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Honeywell Cable & Custom Electronics

DNVGL-CP-0399 Edition March 2016

Flexible Power Cable DLO

Using technology to safeguard your people and your property

Fire Resistant Cables

Quick Reference Applications Guide

Working in Partnership with our Customers.

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Section 5: Medium Voltage Joints - up to 42kV

Construction Method, Material Selection, Fire Prevention & Building Security System For Project 9a : Board 4 ; For Project 9b : Part 4

IEC NORMAS PUBLICADAS. As normas ISO/IEC já estão relacionadas em normas ISO Publicadas

Alarm & Security SOLUTIONS. Access Control Video Surveillance Fire Alarm Life Safety

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

SAFE, FAST PROFESSIONAL WIRING SOLUTIONS STANDARDISED & INDIVIDUAL COMPLEX SMART SOLUTIONS. 25 years: You name it. We have it. DANNEWITZ GmbH & Co

Transcription:

CABLES FOR ALARM AND SAFETY SYSTEMS

2

IT S ALL ABOUT RELIABILITY. It is always important to choose high quality cables, especially when it comes to alarms and safety systems. Even small and seemingly insignificant details can make a big difference in terms of ease of handling, functionality and service life. We have the cables you are looking for We offer the widest range of cables on the market for every kind of installation. The cables we supply carry signals and power supplies. For extra peace of mind concerning fire protection, our cables are available in versions meeting specified fire safety requirements in installations. Halogen free for greater safety We have decided only to include halogen free cables in this brochure. There is a clear trend in that direction, and there is no longer any reason for not choosing halogen free cables. Halogen free cables offer many advantages in particular, they make it easier to escape the building in the event of fire, generating substantial savings in the long run. 100 years of experience thrown in At Nexans we research, develop and manufacture cables for the whole world. For different environments and climates. And we ve been doing it for more than a hundred years. So when you choose our cables, they come with a whole lot more our dedication and all the experience and expertise we ve built up over the decades. 3

PRODUCT SEGMENTS VIDEO SURVEILLANCE (CCTV) Locally installed CCTV (closed circuit TV) systems are increasingly being used as a crime prevention tool. FIRE ALARMS Detector networks often occupy large volumes so cables must be easy to install. Nexans cables are easy to strip and are optimised to simplify installation in pipes. Choose from simple, non twisted pair cables for small conventional systems and twisted pair cables for larger addressable systems. The cables used in fire alarm detector networks should normally have a red sheath. If the cables are required to keep working during a fire, you should use Nexans Alsecure (see page 12 Performance during a fire ). 4

PERFORMANCE DURING A FIRE There is a separate fire class for cables that are required to maintain sircuit integrity during a fire. These cables all have unique insulation material that is not damaged like normal cables. This category can include power supply cables as well as signal cables. They should also be flame retardant low fire hazard cables in other words they must not give off any toxic or corrosive gases, and only small amounts of smoke, if there is a fire. The Nexans cables for these applications are called Alsecure. The unique insulation (INFIT ) makes the cables easy to install while ensuring they still work during a fire. ACCESS PROTECTION Burglar alarms usually have a system of control units and sensors. Indoor and outdoor entry systems contain card readers, central units and computers. The cables used for intruder protection and entry control are signal cables with varying flexibility, shielding and cores. Alternatively, combination cables can be used with separate cores carrying the power supply. Nexans wide range makes it easy to choose the right cables for the various components. 5

VIDEO SURVEILLANCE (CCTV) CCTV (Closed Circuit TeleVision) is a locally installed video surveillance system. A CCTV system consists of cameras, monitors, transmission elements (cables), control systems and storage systems. Our range of halogen free cables for CCTV includes 75 ohm coaxial cable. The S/FTP Category 6A cable together with the IP67 outlet box offers a safe and robust solution for solutions for IP network cameras outdoor and in harsh environments. RG 59 LSZH Coaxial cable for video surveillance. The impedance of the cable: 75 ohm. RG 59 LSZH 0235704 6,1 mm Bobbin/100 RG 59 LSZH 0235708 6,1 mm Bobbin/500 6

S/FTP Category 6A LSZH + PE LANmark Industry outlet IP67 The LANmark Industry outlet enables the installation of data outlets in exposed areas as well as outdoor solutions. The IP67 level of protection is maintained both when the outlet is unused and when the appropriate IP67 patchcords are connected. Includes 2 screened category 6 or category 6A connectors. Category 6A, 500 MHz Screened data cable. The 4 pairs are individually foiled and covered with a common braid. Due to the outer sheath of PE the cable is appropriate for outdoor installation as well as in exposed areas. It can be installed indoors when the PE sheet is removed. The cable fulfills cat 6A performance according to EN 50288, IEC 61156 and TIA 568-B Category 6A 4x2x0,5 0233347 8,6 mm B/500 Cable STK no. IP67 outer with RJ45 cat.6 shielded Snap-in connector, black. 7280048 7

8

YOU OFTEN WON T KNOW WHETHER YOU CHOSE THE RIGHT CABLE UNTIL AFTER A FIRE. People always talk about fire protection but it is important to know what this actually means in practical terms, and to be certain which flame spread rating you need to use. For cables, you also need to distinguish between flame spread, fire hazard properties and fire resistance. Cables that prevent flame spread Cables running through building levels and walls are a great way for fires to spread. So the most important requirement when establishing fire protection is to use cables with properties that prevent the spread of fire. This is why there are general flame spread classes, and these must always be defined. Our cables have clearly marked flame spread classes that are informative and easy to understand. Halogen free saving lives and money Smoke and gases from burning cables often cause the biggest problems for people and equipment. These problems can be reduced if halogen free cables are used. The smoke from halogen free cables during a fire is much thinner and does not corrode metals. This makes it easier to clear smoke from rooms, potentially saving lives. That is why our cables for alarms and safety systems are halogen free. Still working during a fire The most critical cables must also be fire resistant. This means they must be guaranteed to work even during a fire. This is made possible by special insulation material, which is merely altered rather than destroyed by fire. The cable keeps its shape, the conductors are kept separate and the cable continues to work. These cables are needed for the fire alarm system itself, but also for the safety lighting guiding people out of the building, for the smoke extraction fans and for the lifts. Our range includes fire resistant cables for power supply and for communication. 9

FIRE ALARMS Nexans has a full range of cables for fire alarm systems The right cable for the right use Cables for fire alarms are available with either red or grey sheaths depending on the regulations, aesthetic requirements, etc. In larger addressable systems, twisted pair cable should be used, KLM-LSZH 2x1.0 mm. If shielded cable is required, Nexans supplies the KLMA LSZH. If the cables are required to keep working during a fire, fire resistant Alsecure cables are used. KLM Easy LSZH 2x1,0 Halogen free, pair-twisted signal cable. The cable construction is as specified in SS 424 16 54 (EQQYB). KLM Easy LSZH 2x1,0 0233358 5,7 mm Bobbin/500 KLM Easy LSZH 2x1,0 0235713 5,7 mm Bobbin/100 Installation The cables for fire alarms are intended for permanent indoor installation. KLM LSZH Halogen free signal cable. The cable construction is, where applicable, as specified in SFS 2751. KLM LSZH 2x0,8 0233362 4,0 mm Coil/150 KLM LSZH 2x0,8 0233360 4,0 mm Bobbin/600 KLM LSZH 4x0,8 0233368 5,0 mm Coil/150 KLM LSZH 4x0,8 0233364 5,0 mm Bobbin/600 KLMA LSZH Halogen free, pair-twisted signal cable. The cable construction is as specified in SFS 2751. KLMA LSZH 2x0,8 0233370 5,0 mm Coil/150 KLMA LSZH 2x0,8 0233369 5,0 mm Bobbin/600 KLMA LSZH 4x0,8 0233378 5,5 mm Coil/150 KLMA LSZH 4x0,8 0233374 5,5 mm Bobbin/600 10

11

PERFORMANCE DURING A FIRE Fire resistant cables are recommended for use in installations that must maintain circuit integrity during a fire. Using these cables in important alarm, control, signal and power supply systems means you can guarantee they will not be taken down, even if the fire reaches the cables themselves. No gases, little smoke As well as continuing to work during and after a fire, Nexans fire resistant cables are halogen free so they do not release any toxic or corrosive gases, and only small amounts of smoke, if there is a fire. Studies show that this can save lives and money. Installation Examples of systems that must maintain circuit integrity during a fire include signal and safety systems guiding people out of the building. Other examples are smoke extraction fans and lifts. Fire alarm cables, too, if they pass through areas that are not monitored by detectors, are required to maintain circuit integrity during a fire. ALSECURE PLUS 0,6/1kV, FRHF Fire resistant power cable with round or sector shaped, stranded, soldered copper conductor and concentric shielding. For permanent installation in all areas. Fire performance according to IEC 60331, IEC 60332-3. Alsecure Plus 1 kv 2 x 1,5/1,5 0638502 11,9 mm Drum/500 Alsecure Plus 1 kv 3 x 1,5/1,5 0638503 12,5 mm Drum/500 Alsecure Plus 1 kv 4 x 1,5/1,5 0638504 15,2 mm Drum/500 Alsecure Plus 1 kv 2 x 2,5/2,5 0638506 14,7 mm Drum/500 Alsecure Plus 1 kv 3 x 2,5/2,5 0638507 15,2 mm Drum/500 Alsecure Plus 1 kv 4 x 2,5/2,5 0638508 16,4 mm Drum/500 Alsecure Plus 1 kv 4 x 6/6 0638510 18,1 mm Drum/500 Alsecure Plus 1 kv 4 x 10/10 0638511 22,0 mm Drum/500 Alsecure Plus 1 kv 4 x 16/16 0638512 24,2 mm Drum/500 Alsecure Plus 1 kv 4 x 25/16 0638513 26,0 mm Drum/500 Alsecure Plus 1 kv 4 x 35/16 0638514 30,0 mm Drum/500 Alsecure Plus 1 kv 4 x 50/25 0638516 35,0 mm Drum/500 Alsecure Plus 1 kv 4 x 70/35 0638517 36,0 mm Drum/500 Alsecure Plus 1 kv 4 x 95/50 0638518 41,0 mm Drum/500 Alsecure Plus 1 kv 4 x 120/70 0638519 42,2 mm Drum/500 Alsecure Plus 1 kv 4 x 150/70 0638520 49,0 mm Drum/500 Alsecure Plus 1 kv 4 x 185/95 0638521 52,0 mm Drum/500 Alsecure Plus 1 kv 4 x 240/120 0638522 60,0 mm Drum/500 ALSECURE PREMIUM Fire resistant, twisted pair, fire alarm cables for permanent installation indoors or in pipes. Fire performance according to IEC60331, IEC 60332-3. Alsecure Premium 2 x 1,0 mm 0235747 6,2 mm Bobbin/500 Alsecure Premium 10 x 2 x 1,0 mm 0235748 17,0 mm Drum/500 12

ALSECURE PREMIUM 300/500V Fire resistant, halogen free control cables with round, solid copper conductors. This cable is designed for permanent installation on cable ladders, directly on walls or in pipes or ducting. Applications include emergency lighting, fire alarm systems and control systems. Fire performance according to IEC60331, IEC 60332-3. Alsecure Premium 3G1,5 0603470 8,0 mm Drum/500 Alsecure Premium 3G2,5 0603471 10,0 mm Drum/500 Alsecure Premium 4G1,5 0603472 9,5 mm Drum/500 Alsecure Premium 5G1,5 0603473 10,0 mm Drum/500 Alsecure Premium 5G2,5 0603474 12,0 mm Drum/500 13

ACCESS PROTECTION Our cables for intruder alarms and entry systems come in a range of types. We have shielded as well as unshielded twisted pair cables up to hundred pairs. We also offer flexible single wire cables with 4 to 12 cores. Combination cables are also available for entry systems cables with twisted pair signal elements and power supply elements (max 100 V). Fire performance according to CPR cluss Dca-s2,d2,a2. EQQXB Easy TM (halogen free EKKX) Pair-twisted communication cable with halogen free, flame retardant insulation and sheath. An important feature of the cable is that both insulation and sheath are easy to peel. You can even peel the insulation with your nail. Cable Nexans no. Outer diam. Length EQQXB Easy TM 1 x 4 x 0,5 mm 17112041 3,5 mm Bobbin/100 FQQXB Flexible signal and alarm cables for intruder alarms and access control systems. Cable Nexans no. Outer diam. Length FQQXB 4 x 0,22 mm 2 17527141 3,7 mm Bobbin/100 FQQXB 4 x 0,22 mm 2 17527171 3,7 mm Bobbin/500 FQQXB 6 x 0,22 mm 2 17527241 4,2 mm Bobbin/100 FQQXB 6 x 0,22 mm 2 17527271 4,2 mm Bobbin/500 FQQXB 8 x 0,22 mm 2 17527341 4,7 mm Bobbin/100 FQQXB 8 x 0,22 mm 2 17527371 4,7 mm Bobbin/500 FQQXB 12 x 0,22 mm 2 17527441 5,4 mm Bobbin/100 FQQXB 12 x 0,22 mm 2 17527471 5,4 mm Bobbin/500 EQQXB Easy TM 1 x 4 x 0,5 mm 17112071 3,5 mm Bobbin/500 EQQXB Easy TM 2 x 2 x 0,5 mm 17112241 4,3 mm Bobbin/100 EQQXB Easy TM 2 x 2 x 0,5 mm 17112271 4,3 mm Bobbin/500 EQQXB Easy TM 4 x 2 x 0,5 mm 17112441 5,5 mm Bobbin/100 EQQXB Easy TM 4 x 2 x 0,5 mm 17112471 5,5 mm Bobbin/500 EQQXB Easy TM 6 x 2 x 0,5 mm 17112641 6,0 mm Bobbin/100 EQQXB Easy TM 6 x 2 x 0,5 mm 17112671 6,0 mm Bobbin/500 EQQXB Easy TM 10 x 2 x 0,5 mm 17112941 7,3 mm Bobbin/100 EQQXB Easy TM 10 x 2 x 0,5 mm 17112971 7,3 mm Bobbin/500 EQQXB Easy TM 20 x 2 x 0,5 mm 17113098 9,8 mm Bobbin/500 EQQXB Easy TM 30 x 2 x 0,5 mm 17113198 11,7 mm Bobbin/500 EQQXB Easy TM 50 x 2 x 0,5 mm 17113398 14,4 mm Bobbin/500 EQQXB Easy TM 100 x 2 x 0,5 mm 17113598 19,5 mm Bobbin/500 MHS LSZH Pair-twisted, shielded communication cable with halogen free, flame retardant sheath. The cable construction is, where applicable, as specified in SFS 5739. MHS LSZH 1x4x0,5 0233380 5,0 Coil/100 MHS LSZH 1x4x0,5 0233379 5,0 Drum/1000 MHS LSZH 3x2x0,5 0233382 6,0 Coil/200 MHS LSZH 3x2x0,5 0233381 6,0 Drum/1000 MHS LSZH 5x2x0,5 0233384 6,5 Coil/150 MHS LSZH 5x2x0,5 0233383 6,5 Drum/1000 MHS LSZH 10x2x0,5 0233386 8,5 Coil/100 MHS LSZH 10x2x0,5 0233385 8,5 Drum/1000 14

FLQQBR Combined power supply and signal cables for intruder alarms and entry systems. The twisted pair signal element is unshielded. Cable Nexans no. Outer diam. Length FLQQBR 2 x 1,5 + 2 x 2 x 0,5 mm 2 17030698 8,5 mm Drum/500 FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm 2 17030141 6,5 mm Bobbin/100 FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm 2 17030171 6,5 mm Bobbin/500 FLQQBR 2 x 1,0 + 2 x 2 x 0,22 mm 2 17030271 7,5 mm Bobbin/500 FLAQQBR Combined power supply and signal cables for intruder alarms and entry systems. The twisted pair signal element is unshielded. Cable Nexans no. Outer diam. Length FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm 2 17037141 6,5 mm Bobbin/100 FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm 2 17037171 6,5 mm Bobbin/500 FLAQQBR 2 x 1,0 + 2 x 2 x 0,22 mm 2 17037298 8,0 mm Drum/500 FLAQQBR 4 x 1,0 + 2 x 2 x 0,22 mm 2 17037698 8,7 mm Drum/500 FLAQQLY Combined power supply and signal cable for intruder alarms and entry systems. The pairs for signalling have a common screen of aluminium/polyesterfoil. The cable has a protective PE sheath covering the inner sheat of halogen free flame retardant plastic compound and is intended for fixed installations both indoor and outdoor. Cabel Nexans no. Outer diam. Length FLAQQLY 2 x 1,0 + 2 x 2 x 0,22 mm 2 17039298 9,0 mm Drum/500 15

NEXANS SWEDEN AB KABELGATAN 1 514 81 GRIMSÅS 0325-800 00 www.nexans.se @nexanssweden CABLES FOR ALARM- AND SAFETY SYSTEMS 2018 16