FANERGY Far more than just a fan.

Similar documents
FANERGY Far more than just a fan.

RLS2000, RLS1000 LED Lighting Systems

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Direct-Drive Gas Power Blowers

Easy-to-read controller with large rheostat knob and start/stop switch. Explosion proof motor

RLS2000, RLS1000 LED Lighting Systems

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Additional Materials: Instructor s PowerPoint, Question Files

DIRECT-DRIVE GAS POWERED BLOWERS SPECIAL OPERATIONS BLOWERS

TYPHOON. New Ventilation Systems from RENZ :33

Manufacturer of RAMFAN Portable Ventilators. Fire Rescue Portable Ventilation Solutions for Smoke Removal

IMPORTANCE of FIREGROUND VENTILATION PRACTICES and DYNAMICS IN FIREFIGHTING (PART I)

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

Hot water super class HDS 12/18 4S *AU

MASTER COURSE OUTLINE

With combustion engine HD 801 B. Equipment: Trigger gun Extended highpressure. Technical data

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

POLY extinguishing systems. The high-performance, unique, and versatile extinguishing system for initial, effective fire fighting.

ONE SEVEN FAST. EFFECTIVE. SAFE. ENVIRONMENTALLY FRIENDLY

TUNNEL FANS STANDARD AND HOT SMOKE

Based on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Edition

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

OPERATING INSTRUCTIONS

EASTERN ARIZONA COLLEGE Fire Department Operations I

Topic: Mechanical Ventilation Refresher Reference #: DG Level of Instruction: In service personnel Time Required: 3 hours

Smoke Management in High-Rise Structures

- CONSTRUCTION FIRE SAFETY STANDARDS

PATTERNS OF FIREFIGHTER FIREGROUND INJURIES

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

NEW. Thermotank Quadroline. living full of energy. The new generation of plastic storage tanks. Energy systems

Hazardous Goods Warehouse. VOSSCHEMIE GmbH. Preventive Fire Protection. Case study

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

PRODUCT CATALOGUE V1.5

- CONSTRUCTION FIRE SAFETY STANDARDS

DCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS

5 Key Stages to Risk Assessment

U.S. Firefighter Disorientation Study Prepared by William R. Mora, Captain San Antonio Fire Department San Antonio, Texas.

Chapter 3 FF II Fire Department Communications

INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

AIRPORT FIRE FIGHTER ID#: STANDARD:

Washer Extractors TWE 10-15

A Design So Smart It's Simple. AIR CONDITIONERS & HEAT PUMPS RUUD. We Thought of Everything... And Then Some.

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

VARIO CARBON TECHNOLOGIE AG VARIO VARIOCARBON CARBON HIGH - PERFORMANCE FIREFIGHTING SYSTEMS

ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

With combustion engine HD 728 B Cage. Equipment: Trigger gun Extended highpressure. Technical data

PLUS SIZE EXTINGUISHERS CEASEFIRE PLUS

Cold water compact class HD 5/15 C

Condensation drying for industry and trade

Xpert HD Xpert HD 7140, ,

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin

Rapid Intervention Team

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

Ground-engaging telehandler

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES

Essentials of Fire Fighting 6 th Edition Firefighter I

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

ULTRA HIGH PRESSURE FIRE SUPPRESSION SYSTEMS Product Catalog HMAFIRE.COM FIRE

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Westbury Fire Department: Hose Company 2 Drill 7/24/14 Thinking Beyond the Obvious or the Norm

SKILL VERIFICATION BOOK FIREFIGHTER I MODULE II FIRE PROTECTION BUREAU. Assigned to: Name:

All NIGHTBRIGHT photoluminescent signs are non-electric, non-toxic and nonradioactive.

Where There's Smoke. Warrant Article 4 - New Fire Station

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

All rights reserved! P/N REV 01 P1

HD 5/12 C + Mobility. Accessory storage

Full-size Classic Hot Water Pressure Washers. Powerful, user-friendly and fuel-efficient

Hot water compact class HDS 5/12 C *AU

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

The Professional Choice

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

Solid biofuel solutions

Technical Information

4 Storage cabinets SCALA

automatic FiReFighTing SYSTeMS in PainT booths

USER MANUAL KGNVCTBVAA

Tunnel. Neumarkt. Stationary Fire Protection Case Study

Safety training Monitor-based workstation Topics:

PRODUCT CATALOGUE V1.3

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

HD 7/11-4 Cage Classic

Waste Recycling. Korn Recycling GmbH. Stationary Fire Protection Case Study

I. It shall be the responsibility of the department officers to implement this operating guideline.

WARNING VILPRA WOOD WOOD HEATER MANUAL. Marketing: SpaDealers. Korsnäs FINLAND +358 (0)

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

San Joaquin County Office of Education Career & Technical Education Fire Fighter Technology CBEDS#: 5833

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

Industrial Ventilation Equipment

NFPA Fire Fighter I (Including Entry Level Fire Fighter) Task Book

HDS 6/14 C. Large tilting aid. eco!efficiency mode. Economical and environmentally friendly even during longer periods

High-Pressure Water Mist systems for the protection of shopping centres in historical city centres

MACHINES ACR SERIES ACR RAMMER

These reasons speak for the pumps from Wacker Neuson. Pump expertise in detail. Overview of all pumps.

Transcription:

FANERGY Far more than just a fan. Protects emergency crews. Saves lives.

2 Rosenbauer FANERGY

FANERGY Rosenbauer The crucial difference New All In One Airflow Technology Powerful Pull-out fan unit Largest tilt adjustment, from -20 to + 20 Simple operating concept with flexible set-up distance from 2 to 7 m High performance fans in two sizes: 16" and 22" Modern design Can also be used for producing water mist and expansion foam 3

Rosenbauer FANERGY The first choice for firefighting. Essential for the safety of emergency crews. More safety for SCBA crews The fan, as an integral part of operational tactics in firefighting, supports emergency crews so that they can perform an inside fire attack as quickly and risk-free as possible. In certain situations, the fan is the only thing that makes an inside fire attack possible. Better visibility enables SCBA crews to operate more quickly on scene. This leads to many advantages essential for the safety of emergency crews: Shorter operating times Faster detection of missing persons Sense of safety for emergency crews (elimination of panic due to zero-vision) Better and faster orientation Reduced risk of scalding from steam A fan as the first unit on scene Thick smoke, poor visibility and high temperatures: often, there are difficult conditions that SCBA crews have to master when first attacking a fire in a burning building. The FANERGY high-performance fan can provide enormous relief in precisely these types of operations. As the first instrument in fire fighting, it is set up in front of the air intake and activated to bring great advantages and increased safety for emergency crews: Improved visibility through fast smoke extraction Smoke control in escape/rescue routes Reduction of temperatures in the burning object Minimisation of the risk of flashover Immediate supply of fresh air for emergency crews and persons trapped in smoke Increased chance of saving fire victims Rapid smoke extraction means the SCBA crew has easier and faster access to the fire zone. The temperature in a burning building can be reduced as well as the risk of flashover and backdraft of flue gases. Furthermore, for injured or missing persons trapped in the smoke, the immediate supply of fresh air can be a lifesaving measure. In short: risk for the emergency crews can be significantly reduced by the use of a FANERGY highperformance fan, and the chances of rescuing people in smoke-filled buildings increases substantially. 4

FANERGY Rosenbauer FANERGY high performance fans provide important preparatory work in firefighting operations. Less damage to property Tactical ventilation is not only crucial for the safety of emergency crews and missing persons, but damage to burning objects can also be drastically reduced. Rapid smoke extraction lowers temperatures in the building, allowing emergency crews to fight the fire faster and in a more targeted fashion. The resulting advantages are obvious: Reduced damage to buildings through faster firefighting Lower water damage due to more selective dispensing of extinguishing agent Minimised risk of collapse of the burning object by rapidly lowering the temperature Lower costs for fire damage repairs 5

Rosenbauer FANERGY The All In One Airflow Technology. More power and more volume. 6 Fan impeller and fan control unit The core piece of the All In One Airflow Technology is the fan unit. Another new feature is the patented fan control unit, which ensures a focused and powerful airflow. This creates a uniform, powerful airflow with an optimized flow pattern. Turbulence and air helices are minimized. This is made possible by the special design of the fan impeller, fan control unit, and the special aerodynamically shaped grille. The new fan unit also ensures an even better drafting performance and thus a better air supply.

FANERGY Rosenbauer Improved performance thanks to the optimised flow pattern The All In One Airflow Technology from Rosenbauer is a completely new concept in ventilation technology. The special design of the fan unit results in an optimized air flow pattern. With this new technology, other concepts such as overpressure and turbo ventilation are combined into one piece of technology. Tactical ventilation of any kind is possible with the new All In One Airflow Technology. The result: air is delivered into buildings in a targeted way with more pressure and more volume. Smoke is evacuated quicker from the object which is on fire, visibility is immediately better and the temperatures are reduced more quickly. Initial attack position (+20 ) +20-20 Basement outflow (-20 ) Maximum tilt angle of -20 to +20 The fan unit can be swivelled at the push of a button and without any accessories from -20 up to +20. The stepless adjustment takes place quickly and easily thanks to a maintenance-free gas strut. This is a considerable advantage during operation due to shorter set-up times. The generous inclination angle ensures more flexibility and efficiency when using the fan. The inclination angle of +20 is optimal for overcoming obstacles. The negative angular position of -20 larger than any other fan on the market is ideally suited to ventilate down stairs, to basement areas and through light shafts. More efficient ventilation with the pull-out fan unit When unfolding the handle, the fan unit automatically lifts out. In this way, the fan is immediately in an angular position of 20. For the majority of operations, this is the ideal setting. It makes it easier to overcome obstacles in the access area of the building (e.g. stairs, platforms). In combination with the new All In One Airflow, the pull-put fan unit also ensures that the airflow reaches the object with maximum efficiency. 7

Rosenbauer FANERGY Operation is easier and safer than ever before. 1 2 3 Lift from the vehicle Fold handle bar upwards Nozzle automatically sw Flexible installation distance of 2 to 7 m The use of a fan protects emergency crews and can save the lives of persons subjected to smoke. The key to successful ventilation is proper use. Thanks to the new All In One Airflow Technology, all existing fan technologies are combined into one, and using it is easier than ever before. The fan can be placed at a flexible distance of 2 to 7 m in front of the air intake. For maximum air flow, a set up distance of approx. 2 m is recommended. 545 mm Smallest dimensions 545 mm 490 mm During the development of the completely new FANERGY series, the engineers at Rosenbauer were mindful to design powerful and multi-functional devices that are also compact. The result is the smallest fan in the 16" category when folded. Its minimal footprint leaves space in the vehicle for more equipment. 8

FANERGY Rosenbauer One operating concept for everything. Proper use in operation. 4 5 ivels into the attack position of +20 Position FANERGY at a distance of 2 to 7 m Power-up the FANERGY Safe option: LED light package The integrated LED light package is unique and ensures more safety for operations in the dark. The built-in LEDs are arranged centrally behind the fan unit to illuminate in the direction of the air opening and thus serve as an orientation aid for the SCBA crew. On the rear side of the fan, two LED elements ensure good visibility of the device, essential for safe operations in the dark. The LED light package is optional for all models. 9

Rosenbauer FANERGY A redevelopment with many refinements. Components and accessories. Pull-out fan unit When unfolding the handle, the fan unit is lifted out from the transport position and put into the initial attack position of +20. Inclination angle from -20 to +20. Centrally integrated water spray unit For the generation of water mist and expansion foam. Integrated air control with guard Provides a powerful and effective airflow. The fan is available in two sizes: with a fan unit of 16" or 22". Robust body The body is made of high quality plastic, has a powdered aluminium frame, stainless steel components and convinces with its durability. For the new FANERGY, rust and corrosion are not an issue. Chocks For stopping air inlets and outlets and/or doors, windows, elevators and shafts. Two chocks of non-slip silicone are included in the delivery. The fan provides receptacle options for up to 4 wedges. 10

FANERGY Rosenbauer Cushioned handle Secure and easy opening and closing of the handle through the built-in damping system. Exhaust adapter For dissipating the engine exhaust gases using a standard DIN-exhaust hose. Included in scope of delivery. LED light package For illumination of the controls and the working area of the fan. Two drive variants The new FANERGY can optionally be driven by combustion engine (B&S or Honda) or an electric motor. Fold-out stabiliser Cushions against backlash and ensures that the fan is stable and secure in its operating location. The FANERGY can even be positioned on uneven, sloping or soft terrain by means of the fold-old stabiliser. Transport wheels The wide transport wheels can handle any surface and are maintenance-free. Storage compartment for foam net The foam net is stowed directly on the device and is instantly accessible. It requires no additional storage space, which saves space in the vehicle and reduces the set-up time. 11

Rosenbauer FANERGY Water mist and foam use. New details and innovative ideas. Multi-purpose use With regard to operational tactics, two further characteristics of the FANERGY fan are interesting: water mist as well as expansion foam can be produced. The mobile high-performance fan is equipped with a central water spray unit. Due to the high throw range of the water mist, buildings, gas cylinders, hazardous goods containers, batteries, etc. can be cooled and protected from a safe distance. Effective suppression of dangerous gases and steam is also possible using the water mist. In addition, the fan performs a valuable service as an expansion foam generator. Central water spray unit Through the central placement of the water spray unit in the centre of the nozzle, the water mist can be applied with more air power than ever before. Thanks to the optimised air power of the FANERGY, a throw range of up to 20 m can be achieved. The flow rate at 7 bar is approx. 200 l. The handling is understandably fast and easy: no extra accessories, no adapters, and used in combination with the usual equipment of the fire department. The fire hose can be connected directly to the fan via a Storz C-connection, via which the FANERGY is supplied with water, thus discharging a water mist. Throw ranges of up to 20 m possible Central water spray unit 12

FANERGY Rosenbauer With air tube for foaming cellars and underground facilities. Foam net stowed in a small compartment Pull the foam net over the fan The fan as a foam generator The fan can even produce expansion foam when used in conjunction with the foam net. The net is stored in a small compartment directly below the housing of the fan, which allows it to be carried along at all times. It is simply pulled over the ventilator intake and fixed with a handle. Expansion foam can be produced by using a supplemental standard Z2 proportioner. The expansion foam can be introduced to firefighting by air hoses in basement areas or underground facilities. Alternatively, the fan can be used on turntable ladders to convey foam to roofs or sources of fire above ground. 13

Rosenbauer FANERGY Two drive variants. Combustion engine The powerful version. The FANERGY high performance fan with combustion engine is the most powerful and lightest model. It is available in two different sizes with 16" and 22" diameters. Two 1-cylinder engines are available: from Briggs & Stratton or from Honda. Technical data V22 V16 Propulsion engine B&S 1-cylinder 4.8 kw (6.5 hp) or Honda 1-cylinder GX200 4.8 kw (6.5 hp) Air outlet diameter approx. 22"/560 mm approx. 16"/410 mm Air flow rate approx. 36,100 m³/h approx. 23,900 m 3 /h Effective air flow rate approx. > 65,000 m³/h approx. > 50,000 m 3 /h Dimensions (W x H x D) 636 x 695 x 490 mm 545 x 545 x 490 mm Weight (filled with oil, empty fuel tank) approx. 46 kg approx. 41 kg Fuel/tank capacity Running time with one tankful Lead-free gasoline >91 octane/approx. 3 l approx. 110 min. at full capacity 14

FANERGY Rosenbauer Electric motor The universal, quiet and environmentally friendly alternative FANERGY high performance fans with electric motors have a number of strengths: they are quiet, environmentally friendly, and exhaust-free. The power is steplessly adjustable from 0 100 %. Its value is shown on a convenient display which is also visible in the dark. The integrated starting current limiter ensures that the drive functions smoothly with a 5 kva power generator. FANERGY models with electric motors can also be connected to any 230 V household socket using the shock-resistant plug. Interior setup is possible without reservation. The greatest advantage of the electric fan is that it can operate in any orientation, and its airflow can be used vertically and horizontally. For example, the fan can be placed facing a basement or sewer opening. This makes it universally applicable and flexible in terms of positioning. Technical data E22 E16 E16 COMPACT E16Ex* Explosion protection Ex II 3G C T3 Propulsion engine 230 V, 2,2 kw continuously adjustable 400 V / 1,85 kw Air outlet diameter approx. 22"/560 mm approx. 16"/410 mm approx. 16"/410 mm approx. 16"/410 mm Air flow rate approx. 31,000 m³/h approx. 14,900 m 3 /h approx. 14,900 m 3 /h approx. 14,900 m 3 /h Effective air flow rate approx. > 61,000 m³/h approx. > 30,000 m 3 /h approx. > 30,000 m 3 /h approx. > 30,000 m 3 /h Dimensions (W x H x D) 636 x 695 x 490 mm 545 x 545 x 490 mm 489 x 613 x 448 mm 569 x 630 x 460 mm Weight approx. 50 kg approx. 45 kg approx. 40 kg approx. 47 kg *All models in the NEW FANERGY 2016 product range except the E16Ex variant 15

FANERGY High performance fans Order data for the FANERGY with combustion engine FANERGY V22 with B&S engine FANERGY V22 with Honda engine FANERGY V16 with B&S engine FANERGY V16 with Honda engine Standard design 513030 513031 513020 513021 with water spray unit 513032 513033 513022 513023 with light package 513034 513035 513024 513025 with water spray unit and light package 513036 513037 513026 513027 Ordering data for FANERGY with electric motor FANERGY E22 with E-motor FANERGY E16 with E-motor FANERGY E16 COMPACT with E-motor FANERGY E16Ex* with E-motor Standard design 513050 513040 513070 51195001 with water spray unit 513051 513041 513071 - with light package 513052 513042 - - with water spray unit and light package 513053 513043 - - *All models in the NEW FANERGY 2016 product range except the E16Ex variant Ordering information options / accessories 513010 Water spray unit for FANERGY 16" 513011 Water spray unit for FANERGY 22" 512026 Foam net for FANERGY 16" 512016 Foam net for FANERGY 22" 703500 Z2 proportioner 703810 Dip tube, approx. 1.5 m length 201105 SYNTHETIC SPECIAL handline, approx. 5 m length 705110 Multi-application foam compound, 20 l can 51181501 PE air tube with belt for FANERGY 16", length approx. 20 m 51191001 PE air tube with belt for FANERGY 22", length approx. 20 m 512061 Rigid air tube with belt for FANERGY 16", length approx. 3 m 512060 Rigid air tube with belt for FANERGY 22", length approx. 3 m 075715 Service hour meter and revolution counter 654400 Exhaust gas hose for all V models 601031 Forcible entry tool 513020E08 Chocks FANERGY E16Ex www.rosenbauer.com Follow us on FANERGY E16 COMPACT VI0563/FANERGY_EN_2017_10_149772 Text and images non-binding. The images may depict special editions that are only available at an additional charge. Subject to change due to technical advances.