The most affordable codeless arming and disarming available with a slim new look!

Similar documents
734N Wiegand Interface Module

734 Weigand Interface Module INSTALLATION AND PROGRAMMING GUIDE

1134 Wireless Wiegand Module INSTALLATION AND PROGRAMMING GUIDE

734N Wiegand Interface Modules INSTALLATION AND PROGRAMMING GUIDE

XRSuper6. User s Guide

One panel offers everything you want built-in

clear touch security with style

5-inch, full-color display. Easy-to-use carousel menu. Interactive shield for quick arming status. All/Perimeter, Home/Sleep/ Away or six Areas

XR500/XR100. User s Guide

INSTALLATION GUIDE XTLN-WIFI PANEL

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

Silencing an Alarm All/Perimeter or Home/Sleep/Away System What to do when a trouble tone is sounding

XT30/XT50 U S E R G U I D E

Silencing an Alarm All/Perimeter or Home/Sleep/Away System What to do when a trouble tone is sounding

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

XRSuper6. User s Guide

Integrated Security Solutions

XR100/XR500 USER GUIDE

XTLC PANEL INSTALLATION GUIDE

Silencing an Alarm All/Perimeter, Home/Sleep/Away, or Home/Sleep/Away with Guest System

OJD ITB No Attachment E Duress Alarm Equipment Specifications

Integrated Security Solutions

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

780 Keypad Demonstrator Module

DS7400Xi Addressable Control/ Communicator

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

Silencing an Alarm All/Perimeter, Home/Sleep/Away, or Home/Sleep/Away with Guest System

What to do when a trouble tone is sounding

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Silencing an Alarm All/Perimeter and Home/Away Systems. Area Systems. What to do when a trouble tone is sounding

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

SYSTEM USER GUIDE X R S E R I E S C O N T R O L P A N E L

XTL/XTLN/XTLN-WiFi USER GUIDE

SENTROL ZX400/ZX410. Security System Control. Programming

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

Destiny Destiny Owners Manual

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Independent Zone Control (I.Z.C.)

XTL Series USER GUIDE

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

Fire Command Keypad. XR5 User s Guide

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

ELT-KLED EliteSuite LED Keypad Installation Manual

Silencing an Alarm All/Perimeter Home/Away Systems Area Systems

SECTION INTRUSION DETECTION

System User Guide. XR Series Control Panel

ARCHITECTURAL DOOR HARDWARE KEY PADS & CARD READERS CATALOG

Security Command User s Guide for XR500 Command Processor Panels Table of Contents

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

Installation Instructions

Digiplex LED Keypads User s Manual

XR10 Command Processor Panel Programming Guide

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Fire Command Center. XR2400F User s Guide

Addressable Fire Alarm Control Panel

RE6100 Series Helix Security and Automation Platform

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

D720 and D1255 Command Centers

Version 1.03 January-2002 USER S MANUAL

1126 Series Ceiling Mount PIR Motion Detector

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

EVO192 v3.0 Fire and Burglary What s New

WHY dmp? SIGNIFICANT FEATURES/BENEFITS

D1255RB/D1256RB/D1257RB

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

Summit 3208GLD USER MANUAL. Electronics Line

Condominium Security Management System

Installation Instructions

XR10/XR20 Command Processor Panels Installation Guide

2000 Series. Program Entry Guide. Control Panels

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

/14 Rev. A LYNX Touch L5210 Series

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Contents. Glossary

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

icontrol OpenHome Converge Panel Interface Module Installation Guide Congratulations on purchasing your Panel Interface module.

Model 17A00 Expansion Enclosure

Control/Communicator Installation Manual

2200 and 2200L ALARM CONTROL SYSTEMS

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

User's Manual 5120XM N8031 6/96

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Installation Guide. XRSuper6 / XR20 / XR40

HARDWIRED CONTROL PANELS

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

T W E N T Y E I G H T E E N

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

Transcription:

The most affordable codeless arming and disarming available with a slim new look! 7000 Series Thinline LCD Keypads offer high- quality, cost-effective security control in a stylish, sleek new design. Visual and audible alarm notification Silence alarm while system remains armed Optional integrated proximity reader Four optional on-board fully programmable zones Retrofit to any DMP panel ENHANCED OPTIONS 7063 and 7073 keypad proximity readers accept DMP 1300 Series proximity credentials. THINLINE LCD KEYPADS 7060 / 7063 / 7070 / 7073 FEATURES Attractive Thinline keypad housing available in several colors Large, 32-character, Liquid Crystal Display (LCD) Custom 16-character home or business name Keypad and logo backlighting turns Red in alarm conditions User-adjustable brightness, tone, and volume controls Built-in diagnostics for ease of service Simple harness connection to 4-wire keypad bus Connect devices directly to keypad zones View system events/user activity through keypad display AC power and Armed LED Suitable for access, burglary, and fire applications Distinct fire, burglary, zone monitor, and prewarn tones Displays time of day, armed zones, and armed areas Optional backboxes for conduit or wall-mount applications Unique silence feature allows the user to silence alarm bells and still keep the system armed Compatible with all DMP panels 26 Customer Service 800.367.4850 x225

THINLINE SERIES VERSATILE SUPERVISED AND UNSUPERVISED OPERATION When programmed for supervised operation, the keypad occupies its own unique device address on the keypad data bus. Unsupervised operation allows you to install an unlimited number of keypads set to the same device address. Increasing the number of keypads allows maximum system operating flexibility. USER-FRIENDLY MENU FUNCTIONS The User Menu allows you to quickly browse through menu options. Disarming and Arming functions are fast and easy. Any function allowed by the user authority level is simply accessed through the keypad, such as silencing alarms, resetting sensors, or displaying events. 2-BUTTON PANIC KEYS The top row of keys can be used as 2-button panic keys. The user simply presses and holds two of the keys simultaneously to send either a panic, non-medical emergency, or fire report to the Central Station. HIGH TRAFFIC AREA PROTECTION The user presents a proximity credential or enters a user code to access any function. This protection level allows you to install the keypad in high-traffic public areas without danger of unauthorized access. END-USER CONTROL Each of the Thinline Series keypads provides a simple User Options menu for adjusting brightness, speaker tone, and volume. VALUABLE VISUAL ALARM INDICATOR In a normal state, both the keypad and logo backlighting remain Green. However, during an alarm state, the keypad and logo turn Red. The change in color allows persons on-site to instantly recognize an alarm condition. Red Backlighting DISTINCT SOUND PATTERNS The keypads also provide distinct sound patterns for fire, burglary, zone monitor, and prewarn that can help users identify the event occurring on their system. RETROFIT ANY EXISTING DMP SYSTEM Retrofitting is quick and easy. Thinline keypads have the same footprint as existing DMP keypads and mount in currently installed backboxes. Thinline Series keypads require no special modules or panel upgrades. You can provide a new look and greater functionality to an existing system at just a fraction of the cost of all new equipment. MULTIPLE-KEYPAD SAVINGS Install multiple keypads on the same wire run. Compatibility and cost savings make the Thinline Series an asset in every installation. OPTIONS The Thinline Series keypads also provide Keypad Options and Keypad Diagnostics menus available only to system installers and service technicians. Enter Keypad Options to set the keypad address and change the default keypad message. Test the keypad operation at any time without disabling the system. The diagnostics program tests the LCD segments and backlighting, each of the 16 keyboard keys, and the four zones on the 7070 and 7073 keypads. Panic Key Labels Green Backlighting fax 800.743.5724 dmp.com 27

UNIVERSAL PROGRAMMING TOOL System installation and programming can be achieved without carrying around or purchasing expensive external programmers since panel and add-on module programming is integrated into DMP Keypads. Individually program panels, an icom Network Alarm Router, icomsl Network Alarm Communicator, and other programmable add-on modules directly from the keypad. 7070/7073 FOUR EXPANSION ZONES Zone expansion is available right on the keypad where you need it the most. The four expansion zones on the 7070 and 7073 models are fully programmable Class B protection zones that can be used for a variety of fire, burglary, and access control applications. ZONE TYPE SELECTION Keypad zones can be programmed using the same zone types available on the panel. Select supervised, unsupervised, night, fire, panic, exit, and emergency operation depending on the user requirements. ZONE DEVICE CHOICES Connect PIRs, door and window contacts, pull stations, sprinkler tamper switches, and silent panic buttons. Plan the installation to afford the best coverage while eliminating potential problems associated with multiple wire runs. 7063/7073 CODELESS ARMING AND DISARMING The innovative 7063 and 7073 Thinline keypads contain an on-board DMP proximity reader that allows users to simply present their proximity credentials to the keypad to gain access to a protected area. 7073 SOFT-SHUNT MOMENTARY BYPASS To provide an entry and exit window on systems with 24-hour perimeter protection, DMP offers the Soft-Shunt feature. Soft- Shunt allows the user enough time to enter or exit the area. If the door remains open when the timer expires, a zone open/short is sent to the panel for the keypad Zone 2. REQUEST-TO-EXIT (REX) To enable easy user exit from an area, connect a motion sensing or mechanical device to Zone 3 on the keypad. As the user trips the zone, the keypad activates the door strike allowing the user to exit the area without presenting a card or entering a user code. PRIVATE LABELING DMP offers dealers the option to present their company logo on the 7000 Series keypads. The logo displays on the rubber logo insert and replaces the DMP logo. The backlighted logo glows Green during normal operation and turns Red in an alarm state. Place Your Logo Here KEYPAD MODEL FEATURES Model 2-Button Panic Red in Alarm 4-Zones Internal Prox Reader Wiegand Input Internal Form C Door Strike Relay 7060 X X 7063 X X X 7070 X X X 7073 X X X X X 28 Customer Service 800.367.4850 x225

THINLINE SERIES KEYPAD ACCESSORIES Backboxes 695/696 4 Square Mounting Box Keypad Wiring Harness 300 4-wire harness 300-5 5-wire harness 300-12 12-wire harness 300-512 12-wire harness, 5 ft. long HID Proximity Credentials 1306 Prox Patch 1306PW Prox Patch 1326 ProxCard II Card 1346 ProxKey II Access Device 1351 ProxPass 1386 ISOProx II Card External Proximity Readers PP-6005B ProxPoint Plus Proximity Reader MP-5365 MiniProx Proximity Reader PR-5455 ProxPro II Proximity Reader MX-5375 MaxiProx Proximity Reader TL-5395 ThinLine II Proximity Reader KEYPAD ORDERING INFORMATION The Thinline Series keypads are available in White, Ivory or Black to compliment any decor. Select from the following options: 7060-W 7063-W 7070-W 7073-W White 7060-I 7063-I 7070-I 7073-I Ivory 7060-B 7063-B 7070-B 7073-B Black SPECIFICATIONS Operating Voltage 12 VDC Dimensions 7 W x 5.25 H x 0.5 D Display Type LCD Colors White, Ivory, Black Compatibility 7000 Thinline Series keypads are compatible with all DMP panels. Current Draw 7060 Standby 72mA Alarm 87mA 7063 Standby 85mA Alarm 100mA 7070 Standby 72mA + 1.6mA per active zone Alarm 87mA + 2mA per active zone 7073 Standby 85mA + 1.6mA per active zone Alarm 100mA + 2mA per active zone LISTINGS AND APPROVALS Underwriters Laboratory (UL) Listed UL 294 Access Control System Units UL 365 Police Connected Burglar UL 609 Local Burglar UL 1023 Household Burglar UL 1076 Proprietary Burglar UL 1610 Central Station Burglar UL 985 Household Fire Warning UL 864 Fire Protective Signaling New York City (MEA) California State Fire Marshal (CSFM) FCC Part 15 RFID Reader FCC ID: CCKPC0086 For additional information, access www.dmp.com and select Compliance. fax 800.743.5724 dmp.com 29

Aqualite TM keypads classic function meets innovative design The Aqualite cool blue radiance delivers high-tech design to any residential or commercial installation. The Aqualite keypads are loaded with the same flexible features as standard DMP keypads. Visual and audible alarm notification Silence alarm while system remains armed Optional integrated proximity reader Four optional on-board fully programmable zones Retrofit to any DMP panel ENHANCED OPTIONS 7063A and 7073A keypad proximity readers accept DMP 1300 Series proximity credentials. AQUALITE LCD KEYPADS 7060 A/ 7063A/ 7070 A/ 7073A FEATURES Attractive Aqualite keypad housing available in three colors Large, 32-character, blue Liquid Crystal Display (LCD) Custom 16-character home or business name Keypad and logo backlighting turns Red in alarm conditions User-adjustable brightness, tone, and volume controls Built-in diagnostics for ease of service Simple harness connection to 4-wire keypad bus Connect devices directly to keypad zones View system events/user activity through keypad display AC power and Armed LEDs Suitable for access, burglary, and fire applications Distinct fire, burglary, zone monitor, and prewarn tones Displays time of day, armed zones, and armed areas Optional backboxes for conduit or wall-mount applications User-safety feature allows the user to silence alarm bells and still keep the system armed Compatible with all DMP panels 30 Customer Service 800.367.4850 x225

AQUALITE SERIES VERSATILE SUPERVISED AND UNSUPERVISED OPERATION When programmed for supervised operation, the keypad occupies its own unique device address on the keypad data bus. Unsupervised operation allows you to install an unlimited number of keypads set to the same device address. Increasing the number of keypads allows maximum system operating flexibility. USER-FRIENDLY MENU FUNCTIONS The User Menu allows you to quickly browse through menu options. Disarming and Arming functions are fast and easy. Any function allowed by the user authority level is simply accessed through the keypad, such as silencing alarms, resetting sensors, or displaying events. 2-BUTTON PANIC KEYS The top row of keys can be used as 2-button panic keys. The user simply presses and holds two of the keys simultaneously to send either a panic, non-medical emergency, or fire report to the Central Station. HIGH TRAFFIC AREA PROTECTION The user presents a proximity credential or enters a user code to access any function. This protection level allows you to install the keypad in high-traffic public areas without danger of unauthorized access. END-USER CONTROL Each of the Aqualite Series keypads provides a simple User Options menu for adjusting brightness, speaker tone, and volume. VALUABLE VISUAL ALARM INDICATOR In a normal state, both the keypad and logo backlighting remain Blue. However, during an alarm state, the keypad and logo turn Red. The change in color allows persons on-site to instantly recognize an alarm condition. Red Backlighting DISTINCT SOUND PATTERNS The keypads also provide distinct sound patterns for fire, burglary, zone monitor, and prewarn that can help users identify the event occurring on their system. RETROFIT ANY EXISTING DMP SYSTEM Retrofitting is quick and easy. Aqualite keypads have the same footprint as existing DMP keypads and mount in currently installed backboxes. Aqualite Series keypads require no special modules or panel upgrades. You can provide a new look and greater functionality to an existing system at just a fraction of the cost of all new equipment. MULTIPLE-KEYPAD SAVINGS Install multiple keypads on the same wire run. Compatibility and cost savings make the Aqualite Series an asset in every installation. OPTIONS The Aqualite Series keypads also provide Keypad Options and Keypad Diagnostics menus available only to system installers and service technicians. Enter Keypad Options to set the keypad address and change the default keypad message. Test the keypad operation at any time without disabling the system. The diagnostics program tests the LCD segments and backlighting, each of the 16 keyboard keys, and the four zones on the 7070A and 7073A keypads. Panic Key Labels Blue Backlighting fax 800.743.5724 dmp.com 31

UNIVERSAL PROGRAMMING TOOL System installation and programming can be achieved without carrying around or purchasing expensive external programmers since panel and add-on module programming is integrated into DMP Keypads. Individually program panels, an icom Network Alarm Router, icomsl Network Alarm Communicator, and other programmable add-on modules directly from the keypad. 7070A/7073A FOUR EXPANSION ZONES Zone expansion is available right on the keypad where you need it the most. The four expansion zones on the 7070A and 7073A models are fully programmable Class B protection zones that can be used for a variety of fire, burglary, and access control applications. ZONE TYPE SELECTION Keypad zones can be programmed using the same zone types available on the panel. Select supervised, unsupervised, night, fire, panic, exit, and emergency operation depending on the user requirements. ZONE DEVICE CHOICES Connect PIRs, door and window contacts, pull stations, sprinkler tamper switches, and silent panic buttons. Plan the installation to afford the best coverage while eliminating potential problems associated with multiple wire runs. 7063A/7073A CODELESS ARMING AND DISARMING The innovative 7063A and 7073A Aqualite keypads contain an on-board DMP proximity reader that allows users to simply present their proximity credentials to the keypad to gain access to a protected area. For added flexibility, the 7063A and 7073A can also read HID 1300 series proximity credentials. 7073A SOFT-SHUNT MOMENTARY BYPASS To provide an entry and exit window on systems with 24-hour perimeter protection, DMP offers the Soft-Shunt feature. Soft- Shunt allows the user enough time to enter or exit the area. If the door remains open when the timer expires, a zone open/short is sent to the panel for the keypad Zone 2. REQUEST-TO-EXIT (REX) To enable easy user exit from an area, connect a motion sensing or mechanical device to Zone 3 on the keypad. As the user trips the zone, the keypad activates the door strike allowing the user to exit the area without presenting a card or entering a user code. PRIVATE LABELING DMP offers dealers the option to present their company logo on the Aqualite Series keypads. The logo displays on the rubber logo insert and replaces the DMP logo. The backlighted logo glows Blue during normal operation and turns Red in an alarm state. Place Your Logo Here KEYPAD MODEL FEATURES Model 2-Button Panic Red in Alarm 4-Zones Internal Prox Reader Wiegand Input Internal Form C Door Strike Relay 7060A X X 7063A X X X 7070A X X X 7073A X X X X X 32 Customer Service 800.367.4850 x225

AQUALITE SERIES KEYPAD ACCESSORIES Backboxes 695/696 4 Square Mounting Box Keypad Wiring Harness 300 4-wire harness 300-5 5-wire harness 300-12 12-wire harness 300-512 12-wire harness, 5 ft. long HID Proximity Credentials 1306 Prox Patch 1306PW Prox Patch 1326 ProxCard II Card 1346 ProxKey II Access Device 1351 ProxPass 1386 ISOProx II Card External Proximity Readers PP-6005B ProxPoint Plus Proximity Reader MP-5365 MiniProx Proximity Reader PR-5455 ProxPro II Proximity Reader MX-5375 MaxiProx Proximity Reader TL-5395 Thinline II Proximity Reader KEYPAD ORDERING INFORMATION The Aqualite Series keypads are available in White, Platinum or Black to complement any decor. Select from the following options: 7060A-W 7063A-W 7070A-W 7073A-W White 7060A-P 7063A-P 7070A-P 7073A-P Platinum 7060A-B 7063A-B 7070A-B 7073A-B Black SPECIFICATIONS Operating Voltage 12 VDC Dimensions 7 W x 5.25 H x 0.5 D Display Type LCD Compatibility 7000 Aqualite Series keypads are compatible with all DMP panels. Aqualite keypads are not available in Fire Keypad Variation. Current Draw 7060A Standby Alarm 7063A Standby Alarm 7070A Standby Alarm 7073A Standby Alarm 72mA 87mA 85mA 100mA 72mA + 1.6mA per active zone 87mA + 2mA per active zone 85mA + 1.6mA per active zone 100mA + 2mA per active zone LISTINGS AND APPROVALS Underwriters Laboratory (UL) Listed UL 294 Access Control System Units UL 365 Police Connected Burglar UL 609 Local Burglar UL 1023 Household Burglar UL 1076 Proprietary Burglar UL 1610 Central Station Burglar UL 985 Household Fire Warning UL 864 Fire Protective Signaling New York City (MEA) California State Fire Marshal (CSFM) FCC Part 15 RFID Reader FCC ID: CCKPC0086 For additional information, access www.dmp.com and select Compliance. fax 800.743.5724 dmp.com 33