Helicycle Crew Alerting System (CAS)

Similar documents
Public Safety DAS Annunciator Panel

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Installation and Operation Manual AEC9005 Series Low Voltage Warning and Auxiliary Battery Management Modules

CIRRUS AIRPLANE MAINTENANCE MANUAL

A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS MD SERIES TERRAIN AWARENESS ANNUNCIATION CONTROL UNIT FOR GARMIN TAWS SYSTEMS

Kelly Aerospace Willoughby, OH NC , Rev. A FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR LC40-550FG AIRFRAME DE-ICING SYSTEM

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

21-light Remote Annunciator. Owner s Manual

JUAN RIVERA HELICYCLE BUILDER LOG #2 INSTRUMENT PANELS

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

AS DIGITAL FIRE PUMP CONTROLLER

1592 In Cab Monitor (ICM) QUICK START GUIDE

EXTINGUISHING AGENT RELEASE MODULE

Field Start-Up Sheet Direct Fired Gas Equipment

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

ESP TECHNOLOGIES LIMITED

Victoreen Primalert 35 Area Radiation Monitor

DASSAULT AVIATION Proprietary Data

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

P0032-O2 SENSOR 1/1 HEATER CIRCUIT HIGH

OWNERS MANUAL MODEL 451 (-101 & -201)

CIRRUS AIRPLANE MAINTENANCE MANUAL

Powerohm Resistors Digital HRG System

New Silent Alert Fire Safe System

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

MODEL 5100 VOTING LOGIC MODULE

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA C22.2 No-46 / UL 2021 BEF33H & BEF40H ELECTRIC FIREPLACE

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

PM100/PM100E PLANTER MONITOR. Operator s Manual

Q1. Carefully read the following extract from a safety leaflet. Then answer the questions.

Introduction... 1 System Overview... 1 System Diagram... 2

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

Operator: Save these instructions for future use!

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

20 Light Remote Annunciator

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

The Remote alarm Panel, TYPE RAPv2

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Beacon 410A Gas Monitor Operator s Manual

OPERATION MANUAL KP4041 POLY SCRAP COMPACTOR

The TC-2 also records maximum temperatures reached for each channel in permanent memory.

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

Ozone Generator and Ozone PCB Tests and Fault Troubleshooting

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

PPG meter instrument for power paragliding

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Installation, Operating and Maintenance Manual

SENTRY PRODUCTS, INC. 01/98 SCAN - STAND-ALONE - Sample Specification

Mini-Rooter Operating Instructions

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

Module Features are-configurable, no module jumpers to set

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

1U ULTRA Compact System

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Sierra Series 900 Single & Dual Channel System. Instruction Manual

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET NOVA

ADS-B and Transponder

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

TECH SHEET DO NOT DISCARD PAGE 1. If unsuccessful entry into diagnostic mode, actions can be taken for specific indications:

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Silencing The ALS-1306 Fans

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Model 3300 Technical Support and Installation Manual

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

DETECTION SYSTEMS. GCM Auto Alarm. Instruction Manual. GA0203P01 Rev. D

PORTABLE ENGINE HEATER AND EXTERNAL BATTERY CHARGER. Specifications: Benefits: IN: NC:

MARC70 Installation Manual

TECHNICAL DATA OBSOLETE

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

ACCURATE ELECTRONICS INC

Smart Series TAS-05-11, TAS-05-12

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

AIRDATA COMPUTER ALTITUDE ENCODER AVIONICS COOLING FANS. Model Part Number LIST PRICE DESCRIPTION

T-6B Electrical System. Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Troubleshooting Guide For FG3000 Dual Medium Intensity Lighting System

D O U B L E A U G E R M O R TA R M I X E R OWNER S MANUAL

Transcription:

Helicycle Crew Alerting System (CAS) CAS Logic Boards Mounted on Radio Trays (Only 3 left as of Aug 14 th.) 8/14/2015 page 1 OF 12

INTRODUCTION If you view my Monterey Bay Shoreline video on YouTube, you may notice that my low rotor warning light comes on as I start to climb out after passing a sunken ship towards the end of the video. The alarm worked flawlessly and was indicating that my belts were slipping. But unfortunately I was too busy navigating my way back across a mountain range to notice it. The alarm indicator is bright, and located right under my dual tachometer near the middle of the upper panel, but I never noticed that it was illuminated. It was only after viewing the video that I realized that I had experienced an in-flight problem on that flight. This is not good! In the Helicycle we spend a lot more time looking outside than when flying a fixed wing aircraft. For one thing, we are often flying close to the ground or other obstructions. It s the nature of helicopters and one of the capabilities that attracted me to them. But that presents a potential problem what good are your instruments and warning lights if you don t look at them? Even assuming that you have a good scan going and check your instruments on a regular basis, it can be very difficult to catch a transient fault condition such as a fluctuating oil pressure. My lack of situational awareness on that flight caused me serious concern. It was unrealistic to think that I would improve my instrument scan to the point where that could never happen again. To make matters worse, most of my indicator lights are lower on my panel and even further out of my field of view when looking outside the aircraft. Clearly, something needed to be done. All of the military and commercial passenger aircraft that I have ever worked on have a Crew Alerting System and a sunlight-readable Master Warning Annunciator which is usually located in the center of the glare shield or at the top of the instrument panel. Its purpose is to call attention to any out-of-tolerance condition. The crew can then determine the nature of the problem and deal with it. If this works for these aircraft, it will also work on the Helicycle. In the picture to the left you see my annunciator at the top of the Helicycle upper panel. Since it is higher up on the panel, many times brighter than the individual indicator lights, and substantially larger, it is much easier to see with your peripheral vision while looking outside the aircraft. The Crew Alerting System (CAS) is designed around a group of eight high-quality UMA aircraft instruments that I have customized for the Helicycle. Five are shown in the center of the panel in Figure 1. A total of nine alarm inputs come from those indicators, three from my Rotor RPM Alarm, and one from my 55-Amp alternator, one from the chip detectors, and one from the clutch switch, for a total of fifteen alarms (Figure-2). The CAS logic module is flexible, however, and it can take inputs from many other devices. Figure 1 - Upper Instrument Panel 8/14/2015 page 2 OF 12

TP6 LAMP TEST +13 VDC TP9 TP2 HIGH ENGINE OIL TEMP LOW ENGINE OIL PRES HIGH ENGINE OIL PRES ENGINE BUFFER RELAY ENGINE EGT REDLINE TP4 HIGH TRANS OIL TEMP HIGH FUEL FLOW TRANS BUFFER RELAY TRANS CUSTOM UMA INSTRUMENTS TP3 LOW VOLTAGE HIGH VOLTAGE VOLTAGE BUFFER RELAY VOLTAGE TP7 FUEL QTY FUEL QTY BUFFER RELAY FUEL QTY CHIP CHIP CHIP ALTERNATOR CHARGE ALT CHARGE ALT CHARGE CLUTCH CLUTCH +13 VDC RESET TP5 TP1 CLUTCH TP9 MASTER WARNING LATCHING RELAY MASTER WARNING ANNUNCIATOR ROTOR RPM ALARM PROCESSOR ROTOR LOW ROTOR LOW ROTOR RESET HIGH ROTOR HIGH ROTOR ROTOR REDLINE ROTOR REDLINE +13 VDC Figure 2 - Simplified CAS Logic Board 8/14/2015 page 3 OF 12

MAJOR COMPONENTS IN THE CREW ALERTING SYSTEM Table-2 and Figure-3 show all the interconnections to and from the CAS logic board. As mentioned, this board was designed as one components in an integrated Crew Alerting System. The major components in the CAS are as follows: Customized UMA Engine Oil Pressure indicator (2 alarm outputs) Customized UMA Engine Oil Temperature indicator (1 alarm output) Customized UMA Transmission Oil Temperature indicator (1 alarm output) Standard UMA Fuel Quantity indicator (1 alarm output) Customized UMA Fuel Flow indicator (1 alarm output) Customized Exhaust Gas Temperature indicator (EGT) (1 alarm output) Customized UMA Voltmeter (2 alarm outputs) Helicycle.Org Rotor RPM Alarm processor board (3 alarm outputs) Chip Detectors (1 alarm output MR and TR detectors are wired in parallel) 55-Amp automotive Alternator (1 alarm output) Clutch Engaged Switch (1 alarm output) Master Warning Annunciator Assembly with a normally open DPST momentary push button switch (lamp test) and illuminated warning indicator Normally open SPST momentary push button reset switch CAS LOGIC BOARD THEORY OF OPEERATION LOGICAL S An OR Gate is a circuit with multiple inputs and one output. An OR Gate will produce an output if any one or more of its inputs are active. OR gates are widely used in my circuit and are implemented using silicon diodes. Starting at the top of figure-2, notice that eight of the alarm outputs from the custom UMA indicators are grouped into three alarm outputs using OR gates. This reduce clutter on the instrument panel. SPST REED RELAYS These relays act as buffers for all of the UMA indicator alarms. The UMA instrument alarms are only capable of driving a maximum load of 40 milliamps, so those outputs are buffered to allow them to drive much heavier loads. REMAINING ALARMS The remaining alarms are capable of driving larger loads directly and do not need to be buffered. LAMP TEST SWITCH Each of the alarm inputs drives an OR gate, and one input to each OR gate comes from the Lamp Test switch. The gates isolate each alarm circuit from that common switch. This switch also triggers a reboot of the Rotor RPM Alarm processor board, which will test not only the three alarm indicators, but the processor itself. This switch is located in the Master Warning Annunciator assembly. LATCHING RELAY Each alarm circuit drives one common OR gate which sets a latching reed relay when activated. This relay provides drive to the Master Warning Annunciator. MASTER WARNING ANNUNCIATOR The job of the Master Warning Annunciator is to call attention to a fault condition in a way that is very difficult to miss. It is a large and very bright indicator that is located as close to the top of the upper panel as possible. 8/14/2015 page 4 OF 12

RESET SWITCH Pressing this momentary push button will reset the latching relay and extinguish the Master Warning Annunciator (if all the faults have been cleared). If a fault condition still exists this button will have no effect. The alarm inputs can be grouped into three categories: ALARM INPUTS UMA Indicator alarms These alarm outputs pull a load low during an alarm condition and they are limited to a maximum load of 40 milliamps. These alarms drive small sealed reed relays located on the logic board. No additional loads may be connected directly to the UMA indicator alarm outputs (pins 6 and 7). +13 VDC Inputs A number of the remaining alarm inputs such as the Rotor RPM Alarm output +13 volts to indicate an alarm condition. These lines are capable of driving higher current loads and they are not buffered with reed relays. As a result, they directly drive indicator lights. Grounding Inputs The remaining alarm inputs pull the load to ground to indicate an alarm condition. These inputs are also capable of driving larger loads and they are not buffered with reed relays. They also drive their indicators directly. One example is a chip detector. It shorts the alarm line to ground to indicate an alarm condition. Alarm outputs can also be divided into several groups: Indicator Lights illuminated by applying a ground Indicator Lights illuminated by applying +13 VDC The Master Warning Annunciator which is illuminated by applying +13 VDC ALARM OUTPUTS Note that any suitable alarm can be used in place of an indicator light. I use an aural alarm in place of an indicator light for my rotor redline alarm. Alarm indicators should be limited to a maximum load of 200 milliamps or less. All of my indicator bulbs are T-1 ¾ 14V (Digikey CM330-ND). WIRING All wiring to the CAS logic board terminates in a 37-pin D-Subminiature connector that is supplied with the logic board. See Table-2 and Figure-3 for details. The assumption is made that all wiring is connected directly from the alarm sources and the alarm indicators. If you have any additional connectors in your wiring they will need to be taken into account. For lines that are long such as the ones to the clutch switch and chip detectors, you should use shielded wiring and ground the shield at the CAS logic board. The far end of the shield should float. All remaining wiring will probably be confined to the upper instrument panel and can probably be left unshielded. NOTE: Pins 24 through 30 are set aside for shield grounds as needed. 8/14/2015 page 5 OF 12

CAS POWER-UP AND ENGINE START ALARM SEQUENCE POWER FIRST APPLIED TO INSTRUMENT BUS When power is first applied to the instrument bus the CAS Master Warning Annunciator will illuminate, indicating that one or more alarm conditions exist. At this time the Rotor RPM Alarm processor board will boot up and initiate a self-test by sequencing through its three alarms in order. You would expect to see the following: The Rotor RPM Alarm will complete a self-test and light the low rotor, high rotor, and rotor redline indicators one at a time The ENGINE alarm indicator will be illuminated indicating that the engine oil pressure is low The ALT light will illuminate (if you are using my 55-Amp alternator modification) indicating that there is no charge current The Low Rotor alarm will illuminate after the self-test is complete, indicating a low rotor condition The CLUTCH alarm indicator will illuminate indicating that the clutch is not fully engaged The MASTER WARNING ANNUNCIATOR will illuminate ENGINE RUNNING AT IDLE: The ENGINE alarm indicator should extinguish indicating that the engine oil pressure is now within limits. CLUTCH ENGAGED BLADES TURNING STILL AT ENGINE IDLE: The CLUTCH alarm indicator should extinguish indicating that the clutch is fully engaged. The ATL alarm indicator should extinguish showing that the alternator is charging the batteries ENGINE RUNNING AT FULL SPEED: Low Rotor Alarm extinguishes indicating that the main rotor rpm is now in the green All alarm indicators should be extinguished except the MASTER WARNING ANNUNCIATOR It can now be extinguished by pressing the RESET button (on my cyclic grip). Depending on how you have wired your ship, the CAS will now be monitoring up to fifteen separate parameters for you during your flight. NOTE: The simplified diagram on Figure-3 shows the UMA and Rotor RPM Alarm outputs as mechanical switches for simplicity. They are actually solid state and not mechanical. ALARM TEST When you press the Master Warning Annunciator it will activate all of the alarm indicators including the annunciator itself and also initiate a reboot of the Rotor RPM Alarm processor board. This action tests a large portion of the alarm circuitry and wiring and will give you confidence that the CAS is fully functional. Once the Rotor RPM Alarm has completed its self-test you can extinguish the CAS Master Warning Annunciator by pressing your reset button. During this test the CAS will draw maximum current of slightly more than 1.0 Amps. 8/14/2015 page 6 OF 12

CREW ALERTING SYSEM - LOGIC BOARD WIRING CAS P1 DESCRIPTION STATE WHEN ACTIVATED FROM PIN COMMENTS 19 +13 VDC In Battery Bus To +13 VDC Battery Bus (Fused Internally) 37 Low Engine Oil Pressure Alarm In Low UMA Engine Oil Pressure Gauge 6 18 Low Voltage Alarm In Low UMA Voltmeter 6 36 High Engine Oil Temperature Alarm In Low UMA Engine Oil Temperature Gauge 7 17 High Voltage Alarm In Low UMA Voltmeter 7 35 EGT Redline Alarm In Low UMA EGT Gauge 7 16 High Transmission Oil Temperature Alarm In Low UMA Transmission Oil Temperature Gauge 7 34 High Engine Oil Pressure Alarm In Low UMA Engine Oil Pressure Gauge 7 15 Fuel Flow Redline Alarm In Low UMA Fuel Flow Indicator 7 33 Shield Ground Use as needed to ground shields 14 Master Warning Output High Master Warning Annunciator 1,2,3,4 Pin C to Battery Return 32 Shield Ground Use as needed to ground shields 13 Engine Alarm Out Low ENGINE Indicator Lamp 1 Pin2 to +13 VDC 31 Shield Ground Use as needed to ground shields 12 Voltage Alarm Out Low VOLTAGE Indicator Lamp 1 Pin2 to +13 VDC 30 Shield Ground Use as needed to ground shields 11 Transmission Alarm Out Low TRANSMISSION Indicator Lamp 1 Pin2 to +13 VDC 29 Shield Ground Use as needed to ground shields 10 Master Warning Reset High RESET Momentary Push Button 1 Pin2 to +13 VDC 28 Shield Ground Use as needed to ground shields 9 Lamp Test Input Low Master Warning Annunciator 5 Pins C, 7 and 8 to battery return 27 Shield Ground Use as needed to ground shields 8 Chip Alarm In Low Chip Detectors Depends on sneak path through frame for return 26 Chip Alarm Out Low CHIP Indicator Lamp 1 Pin2 to +13 VDC 7 Low Fuel Quantity Alarm In Low UMA Fuel Quantity Gauge 6 25 Low Fuel Quantity Alarm Out Low FUEL Indicator Lamp 1 Pin2 to +13 VDC 6 Alternator Charge Alarm In (Automotive Only) Low Automotive Alternator L 24 Alternator Charge Alarm Out (Automotive Only) Low CHARGE Indicator Lamp 1 Pin2 to +13 VDC 5 Low Rotor Alarm In High Rotor Alarm Processor Board 2 23 Low Rotor Alarm Out High LOW ROTOR Indicator Lamp 1 Pin2 to battery return 4 High Rotor Alarm In High Rotor Alarm Processor Board 3 22 High Rotor Alarm Out High HIGH ROTOR Indicator Lamp 1 Pin2 to battery return 3 Rotor Redline Alarm In High Rotor Alarm Processor Board 4 21 Rotor Redline Alarm Out High Sonalert Aural Alarm + - to battery return 2 Loose Clutch Alarm In Low Clutch Switch 20 Loose Clutch Alarm Out Low CLUTCH Indicator Lamp 1 Pin2 to +13 VDC 1 Battery Return Battery Bus To Battery Bus Negative Table 1- CAS Logic Board Pinouts 8/14/2015 page 7 OF 12

SIMPLIFIED CAS WIRING DIAGRAM Figure 3 - Simplified CAS Wiring Diagram 8/14/2015 page 8 OF 12

Figure 4 Mechanical Layout of the CAS Logic Board The CAS Logic Board mounts in three places (Figyre-4) using 4-40 standoffs. Use caution when installing the center standoff and do not damage the reed relays on either side. The maximum clearance for this center mount is 0.500 inches. Also insure that the standoffs you use do not short any of the traces on either side of the board. Use metallic standoffs as the mounting pads are used to ground the board to your ship. I suggest mounting to the radio trays as the instrument panel is not a good ground. 8/14/2015 page 9 OF 12

WIRING, TESTING, AND TROUBLESHOOTING Notice in Figure-2 and Figure-5 that there are nine test points on the logic board. These can be very useful during wiring, testing, and troubleshooting. They are also clearly marked on the board itself. I suggest that you wire the CAS is a methodical step-by-step process, checking for proper functionality as you go. If you run into a problem, stop and sort it out before proceeding. I plan to install connectors on all of my sensors. I fabricated a small box with one switch and a pot. I can connect this box in place of any UMA sensor for temperature or pressure and use it to exercise the associated indicator. This will allow me to test the wiring to that indicator and also trigger an alarm condition which will then feed into the CAS Logic Board where it should illuminate the correct indicator and set the latching relay which will illuminate the Master Warning Annunciator. WARNING: Shorting out a test point will probably destroy the board. Be careful and take your time! Figure 5 - PCB Layout 8/14/2015 page 10 OF 12

CONTACT INSERTION AND EXTRACTION Figure 6 - Wire Side of Mating DB-37 female Connector Figure-6 shows the wire side of the mating 37-Pin D-Subminiature connector that you will be wiring to. Observe the contact numbers when installing your wiring. You do not need an insertion tool to insert the contacts just push the contact firmly into the hole until you hear and feel a click. However, if you make a mistake, you will need an extraction tool to remove that wire. Be careful! 8/14/2015 page 11 OF 12

The sunlight-readable Master Caution Annunciator is at the heart of the CAS. I was lucky enough to purchase nine of these illuminated push buttons as new/unused military surplus. They originally sold for about $900 a piece. Needless to say, the quality is very high! The assembly mounts from the front through a rectangular hole in the panel and is clamped into position and held by sliding these pieces over the unit and pulling them tight with the screw as you see. Figure 7 - Master Warning Annunciator The unit uses four T-1 ¾ flanged bulbs in parallel and re-lamps from the front. This is a view of the back of the lamp assembly. It then clicks into position in the front. Figure 8 - Lamp Assembly My intention is to make eight CAS circuit boards which will be mated to eight of these units. Four or five are already spoken for. If you would like one of the remaining three drop me a note at this address: juan(at)helicycles(dot)org. View YouTube video here https://www.youtube.com/watch?v=yeh-0gwmiuw 8/14/2015 page 12 OF 12