INSTRUCTION MANUAL FLOAT TYPE LEVEL SWITCHES HITROL CO., LTD.

Similar documents
Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Limit Switch Box YT-870/875 SERIES

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

A.YITE GROUP (Hongkong & Shanghai)

Dust Concentration Meter

Oil Leak Detector NAR300 System

1510 Side Mounted Level Switch

Description. Applications

BINDER Scientific Product Catalog

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

A.YITE GROUP (Hongkong & Shanghai)

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Tank Gauge Transmitter AT-5000

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

INTRODUCTION / TABLE OF CONTENTS

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Certificate of Compliance

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

Instrumentation and Controls Group

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

High Pressure Conductivity Monitor

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

Series Temperature Controller Instruction Sheet

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Level gauges Series LS Level indicator, switch and transmitter for liquids

Model 144H. Product Data Sheet , Rev DB February Content

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

Screw plug immersion heaters

INTEX INDUSTRIES (XIAMEN) CO.,LTD. Declaration of Composition Acc. to Directive 2002/96/EC (WEEE)

Operating Instructions. For. Alarm Control Module. Model SSR 500

INSTRUCTION & MAINTENANCE MANUAL

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Two-Channel Gas Controller

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Series. Access Power Controllers. Installation Guide

Enraf Servo Gauge 854 ATG

+ + + EUGEN WOERNER. Level Switch KFA-A. Two switching points for level monitoring max.

INTRODUCTION / TABLE OF CONTENTS

Certificate of Compliance

Sitron s CF Line of Flow Switch Monitors

Rotameter series 250 metal tube variable area flowmeter

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Approved by: Document no.: EGT

SET-2000 Oil/Sludge 12 VDC

13-1. Temperature Regulator

Model 4001 Series Single Channel Controller

ASSEMBLY & OPERATING INSTRUCTIONS

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

Technical Data. General specifications. Rated operating distance s n 5 mm

Paragon. Induced Draft, Counter Flow Optional Accessories

Technical Data. Dimensions

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

TM Series. Induced Draft, Counter Flow Optional Accessories

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

CL & CLG Clamp Mount Mixers

Process Protection. MFA 4P Motion Failure Alarm

Industrial Filters Replacement Procedure

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

Oil Leak Detector NAR300 System High Temperature

FLOAT LEVEL SWITCHES Vertical and horizontal models For OEM applications

SET-2000 Hi Level/Oil

Centrifuge/Vortex for PCR plates CVP-2

Instructions. Explosion Proof Smoke Detector U Rev: 9/

50 Disassembly and assembly Cab and its attachments

Rack Mount Series Installation Guide

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Using the DewTrak II Dew Point/ Humidity Transmitter

47LV BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL DC INPUT DIGITAL PANEL METER MODEL. (4 1/2 digit, LED display type)

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology

SpeedClave Steam Sterilizers

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Certificate of Compliance

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch

Model 144H. Product Data Sheet , Rev DB February Content

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

INSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES 62-9FS & FS

Hazardous Area Telephone Model EP600

Flange immersion heaters

Switch-Pro. AU13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

Safety vacuum drying oven for flammable solvents

Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches

REFRIGERATED BATH CIRCULATOR. Instruction Manual. Covers model : LRBC-13C / LRBC-22C. Please read this manual carefully before using the instrument

Exit Stopper. STI-6400 Series

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

DTS Light fittings for explosive atmospheres

RAEGuard 2 PID. User Guide

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual

Dräger Polytron 8100 EC Detection of toxic gases and vapors

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

D564A13002GPS D564A15002GPS Medium Intensity Obstruction Light FAA Compliant

Transcription:

HITROL CO., LTD. HEAD OFFICE.FACTORY.R&D INSTITUDE HITROL CO., LTD 141, Palhakgol-road, Jori-eup Paju-si, Gyeonggi-do, Korea TEL. : (00)-82-31-950-9700 FAX. : (00)-82-31-943-5600 www.hitrol.com INSTRUCTION MANUAL FLOAT TYPE LEVEL SWITCHES HR-30 Series Doc. no. : HR-30(EX) M_Eng_2016, Rev. 5 Issued date : 2016. 11 HITROL CO., LTD. 1

Table of contents Overview of the product 3 Precautions for external wire lead-in method 11 Operation principle 3 Precautions for ground connection 11 Characteristics 3 Attachment and precautions for attachment 11 Specifications 3 Connection method 12 STAINLESS STEEL (FLANGE) 3 STAINLESS STEEL (SCREW) 3 Matters regarding operation and use 13 PVC 4 TEFLON 4 Matters regarding safety and the environment 13 Specifications applied to the FLOAT 4 Product marking 14 Contact point capacity 5 Matters regarding user education 14 SPST 5 SPDT 5 Warranty and contact number 14 Latching Switch SPST&SPDT 5 Warranty and service 14 SPST/SPDT Max. Contact form 5 Head office / factory / laboratory contact number 14 Minimum section distance 6 STAINLESS STEEL 6 PVC 6 TEFLON 6 Material application table 7 Product composition 8 Product size 9 WEATHER-PROOF Version 9 Ex-PROOF Version 9 Maintenance method 10 Precautions for separation 10 Precautions for installation 10 HITROL CO., LTD. 2

Overview The HR-30 Series are measuring instruments that operate with the use of lead switches and magnets; can be applied to various storage containers, including those in chemical factories, which are highly oxidative and corrosive; can be widely used in all industrial areas; and have high reliability and long life spans. Operation principle In the case of the HR-30 Series, the FLOAT made to fit the specific gravity of the measure object moves up and down along with the liquid surface by buoyancy; the magnet installed in the FLOAT operates the REED S/W to generate contact points. Multiple detection positions can be set to issue the level of the upper/lower limit alarms or adjust the alarm levels. Characteristics Frequently used to measure most liquids (HH, H, L, LL) Materials of the detecting element are resistant to corrosive measure objects (PVC, PTFE) Have explosion-proof structures (Ex Version) Durable and highly reliable structure Shows high reliability in level detection Specification STAINLESS STEEL (FLANGE MOUNTING) Model HR-30S HR-30SH HR-30S-Ex HR-30SH-Ex Mounting Flange Temperature Max. 80 Max. 150 Max. 80 Max. 150 Process Pressure Switch Type Switch Form Up to 20kg/cm2(300#) Reed S/W SPST, SPDT Enclosure Weather-Proof Ex-Proof(Ex d IIC T6) Wetted Part Material SUS 304, 316 Process Connection 80A JIS 10K Housing ; Cable Entry PC. ; PF3/4 (F) AL. ; PF 3/4 (F), IP65 STAINLESS STEEL (SCREW MOUNTING) Model HR-30C HR-30CH HR-30C-Ex HR-30CH-Ex Mounting Screw Temperature Max. 80 Max. 150 Max. 80 Max. 150 Process Pressure Switch Type Switch Form Up to 20kg/cm2(300#) Reed S/W SPST, SPDT Enclosure Weather-Proof Ex-Proof(Ex d IIC T6) Wetted Part Material SUS 304, 316 Process Connection PT 2 (M) Housing ; Cable Entry PC. ; PF3/4 (F) AL. ; PF 3/4 (F), IP65 HITROL CO., LTD. 3

PVC Model HR-30V HR-30V-Ex Mounting Flange Temperature Max. 60 Process Pressure Switch Type Switch Form Up to 0.5kg/cm2 Reed S/W SPST, SPDT Enclosure Weather-Proof Ex-Proof(Ex d IIC T6) Wetted Part Material Process Connection PVC 80A JIS 10K FF Housing ; Cable Entry PC. ; PF 3/4 (F), IP65 AL. ; PF 3/4 (F), IP65 TEFLON Model HR-30T HR-30TH HR-30T-Ex HR-30TH-Ex Mounting Flange Temperature Max. 80 Max. 150 Max. 80 Max. 150 Process Pressure Switch Type Switch Form Up to 0.5kg/cm2 Reed S/W SPST, SPDT Enclosure Weather-Proof Ex-Proof(Ex d IIC T6) Wetted Part Material Process Connection SUS 304+TEFLON 80A JIS 10K Housing ; Cable Entry PC. ; PF3/4 (F) AL. ; PF 3/4 (F), IP65 Specifications applied to the FLOAT Float Environment Temperature Pressure Acid Alkaline Oil Solvent Liquid gas 304-20 ~150 Up to 20kg/ cm2 X 316-20 ~150 Up to 20kg/ cm2 PVC -10 ~60 0.5kg/ cm2 X X X TEFLON -20 ~150 0.5kg/ cm2 X X NBR -48 ~60 Up to 20kg/ cm2 X TITANIUM -20 ~150 Up to 10kg/ cm2 X Note: = Excellent = Good = Acceptable X = Not good *Application can be differed according to the specific gravity and the medium HITROL CO., LTD. 4

Contact point Capacity SPST FLOAT Max. switching voltage Max. switching current 1" 24VDC 0.5A 2",3",4" 250VAC/24DC 1A/0.5A SPDT FLOAT Max. switching voltage Max. switching current 1",2" 24VDC 0.25A 3",4" 250VAC/24DC 1A/0.5A Latching Switch SPST&SPDT FLOAT Max. switching voltage Max. switching current 1",2"(SPST) 24VDC 0.25A 3",4"(SPST) 220VAC/24DC 1A/0.5A 3",4"(SPDT) 220VAC/ 24VDC 0.5A/0.5A <Ex-PROOF Version> SPST/SPDT/ Latching Switch SPST&SPDT FLOAT Max. switching voltage Max. switching current 1" 24VDC 0.5A 2,3,4 110VAC/24VDC 1A/0.5A Contact form SPST/SPDT Max. Contact form FLOAT Contact form 1 4-SPST 2-SPDT 2 6-SPST 3-SPDT 3 6-SPST 4-SPDT 4 6-SPST 4-SPDT HITROL CO., LTD. 5

Minimum section distance STAINLESS STEEL STANDARD TYPE FLOAT SIZE 1" 2" 3" 4" Section A (mm) 40 50 100 100 Section B (mm) 55 80 160 170 Section C (mm) 40(100) 50(100) 100 100 LATCHING TYPE FLOAT SIZE 1" 2" 3" 4" Section D (mm) 20 20 20 20 PVC STANDARD TYPE FLOAT SIZE 2" 3" 4" Section A (mm) 100 100 100 Section B (mm) 150 150 150 Section C (mm) 100 100 100 LATCHING TYPE FLOAT SIZE 2" 3" 4" Section D (mm) 20 20 20 TEFLON STANDARD TYPE FLOAT SIZE 1" 2 3" 4" Section A (mm) 40 50 100 100 Section B (mm) 55 80 150 150 Section C (mm) 40(100) 50(100) 100 100 LATCHING TYPE FLOAT SIZE 1 (1.5 ) 2 3 4 Section D (mm) 20 20 20 20 A = Minimum distance for operation at the installed position B = Minimum distance for operation between floats C = Minimum distance for operation at the end of the product D = Minimum distance for outputting two set points with one FLOAT ( )= Minimum distance for operation at the Latching type HITROL CO., LTD. 6

FLOAT application table Product name SIZE Size (mm) D H A GUIDE TUBE Material SG range HR-30S HR-30C HR-30S 1" 2" 3" 4" Ф28 28 Ф9.5 Ф8 316L 0.9 1.3 Ф26 15 Ф9.5 Ф8 Foam NBR 0.8 1.3 Ф49 50 Ф15.5 Ф12.7 316L 0.7 1.0 Ф50 45 Ф20 Ф15.8 Foam NBR 0.6 0.9 Ф45 52 Ф15 Ф12.7 316L 0.7 1.1 Ф73 105 Ф23.5 Ф21.7 316L 1.0 1.5 Ф73 116 Ф23 Ф21.7 Titanium 0.6 0.9 Ф65 90 Ф25 Ф21.7 316L 0.8 1.3 Ф95 119 Ф30 Ф25.4 316L 0.8 1.3 Ф95 103 Ф23 Ф21.7 Titanium 0.6 0.8 Ф95 118 Ф23 Ф21.7 Titanium 0.5 0.6 Ф80 80 Ф28 Ф25.4 Foam NBR 0.5 0.7 Product name SIZE Size (mm) D H A GUIDE TUBE Material SG range 2" Ф49 105 Ф20 Ф18 PVC 1.2 1.7 HR-30V 3" Ф76 110 Ф31.5 Ф26 PVC 1.0 1.6 4" Ф76 110 Ф31.5 Ф26 PVC 1.0 1.6 Product name SIZE Size (mm) D H A GUIDE TUBE Material SG range 1 Ф28 28 Ф11 Ф8 TEFLON 1.2~1.7 1.5 Ф30 30 Ф11 Ф8 PP 1.0~1.7 HR-30T 2" Ф45 50 Ф17 Ф15 TEFLON 1.1 1.7 3" Ф71 100 Ф20.5 Ф18 TEFLON 1.1 1.7 4" Ф83 100 Ф33 Ф28 TEFLON 1.2 1.7 *S.G : Specific gravity HITROL CO., LTD. 7

Product composition Polycarbonate housing MAX. 80 Aluminum Housing MAX. 80 MAX. 150 Aluminum Housing MAX. 80 MAX. 150 Flange Flange Flange Flange 304, 316L 304, 316L PVC 304, 316L, W/TEFLON Flange Screw Stopper Stopper Stopper Stopper 316L 316L PVC TEFLON Guide Pipe 304, 316L Protection Pipe 304, 316L Guide Pipe 304+PVC Guide Pipe 304, 316L W/ TEFLON Float Float Float Float 316L 316L PVC TEFLON Stainless Steel Stainless Steel PVC TEFLON (Guide Type) HITROL CO., LTD. 8

Product size <WEATHER-PROOF Version> HR-30S HR-30V HR-30T HR-30SH HR-30TH HITROL CO., LTD. 9

<Ex-PROOF Version> HR-30S-EX HR-30V-EX HR-30T-EX HR-30SH-EX HR-30TH-EX HITROL CO., LTD. 10

Maintenance method The major parts of HR-30 Series to be inspected are the FLOAT and REED S/W in the sensor element. The life spans of major parts vary with user environments and can be used in optimum conditions through periodic inspections. Therefore, the user should maintain and repair the product through periodic inspections conducted at least once per year. The appearance of the product should be visually checked to see if there is any damage, and if there is scale caused by measure objects, it should be removed for the smooth operation of the FLOAT. The REED S/W can simply be inspected using a Digital Multimeter as follows. Select the buzzer of the Digital Multimeter and connect it to one of product s terminal blocks, E1 E4, and the COM terminal. When the FLOAT is moved, if the buzzer rings at the lower or upper limit contact point, the REED S/W is normal. When checking contact point conditions based on resistance, if the Digital Multimeter indicates 0Ω when the FLOAT is moved, the REED S/W is normal in the NC (Normal Close). In the NO (Normal Open) state, the Digital Multimeter indicates 0Ω when the REED S/W is normal. Moreover, when the product is used for highly viscous liquids, the sensor element should be periodically cleaned. For maintenance, the power of the product should be completely turned off before inspection. Precautions for separation The lines should be separated after checking the level inside the tank and whether or not there is any measure object in the tank. Gloves should be worn when separating the lines in the case of products for high temperatures because burns may occur. The cover of the product should not be opened in cases in which there is an explosive gas atmosphere. In the case of explosion-proof products, the SET SCREW (explosion-proof key) should be unlocked before opening the COVER. The lines should be separated after turning off the power. When opening or closing the cover of the product, be attentive to prevent causing damage to the O-ring or the gasket. HITROL CO., LTD. 11

Precautions for installation When flanges or screws are used for fastening, the size should be the same. The user should place a washer between each bolt and nut to prevent loosening. When fastening flanges to each other, gaskets should be used. (The gaskets should be selected considering the temperature of the content and the pressure of the container.) The user should install appropriate products after judging whether the products are to be used in explosion-proof regions. The power should be supplied when the installation has been completed and the cover has been fastened. Great impacts should not be applied to the product when the product is moved. Precautions for external wire lead-in method The user should use a cable grand connection method or a metal pipe wire lead-in method on wire inlets, and when external wires are led in for connection, products that have been certified for at least the same explosion-proof performance as the relevant explosion-proof equipment should be used. Plugs for closing that passed safety certification tests for at least the same performance as the relevant explosion-proof equipment should be used for external wire inlets not used. Precautions for ground connection (explosion-proof products) Ground connections are divided into external ground connections and internal ground connections. In the case of external ground connections, the size of ground wires should be at least 4mm2 (4mmSQ). Internal ground wires should be of the same size as the power cable and the size of internal grounding terminal lugs should be 3.1mm2 (3.1mmSQ). If the power cable is larger than 3.1mm2, the terminal lug should be taken out before connecting the ground wire. When connecting a ground wire to an internal grounding terminal after taking out the terminal lug, a washer should be used without failure (to prevent loosening). HITROL CO., LTD. 12

Attachment and precautions for attachment When attaching the product, the following matters should be considered. The product may malfunction if the product has been installed at the inlet through which the measure object flows in. Therefore, a guide should be installed in such When the measure object flows or slops; protecting tube type products should be used. case or the product should be installed at a position distant from the inlet for measure When installing the product on a concrete wall, you Diameter d should be larger than the FLOAT. may want to install it as shown in the figure above. HITROL CO., LTD. 13

Connection method The terminals of the products are composed as the following according to contact points and shall be connected as follows. Open the product COVER and insert the cables through the wire inlet. Identify the contact points (E1, E2.) on the terminal block and connect the cables. Weather-Proof Ex-Proof 1F ~ 2F SPST 1F SPDT 3F ~ 5F SPST 2F SPDT 6F SPST 3F ~ 4 SPDT Contact Form Indication E.p) 3-SPST A Contact order indication E.p) 3-SPDT order indication Matters regarding operation and use The product may be made with NO (contact point A) or NC (contact point B) as ordered by the customer and is made with NO (contact point A) unless there is a special request regarding contact points. The shapes of the contact points are as shown by the following figures. Contact point A (OFF) Contact point A (ON) Contact point B (OFF) Contact point B (ON) HITROL CO., LTD. 14

NO NC NO NC ON when the level rises (contact point A) ON when the level drops (contact point B) The stopper that fixed the FLOAT should not be arbitrarily moved. Matters regarding safety and environment Matters that require attention when the product is used - When fastening the product to the container, make sure that the product is maximally pressed to the container by using tools. - The locking device should not be lost while the product is being used, and the product should be locked without failure. - Great impacts should not be applied to the product. Matters that require attention when connecting the product - Wire should be corrected to terminals that correspond to the locations of contact points (refer to the connection method). Disposal of the product - When disposing of the product because it is not usable, the AMP in the product housing shall be separated and disposed of. No special attention is required because there are no parts that affect environments (e.g., mercury switch). Product marking Product identification mark Product identification marks are attached to housings. These marks indicate products model name, serial number, workable temperature, working pressure, and matters regarding output. Serial numbers are unique manufacturing numbers for the identification of products. <Weather-Proof Version> <Ex-Proof Version> HITROL CO., LTD. 15

Matters regarding user education The above matters should be fully understood, and the temperature of fluids in the container where the product is used shall not exceed 80 in the case of general types and 150 in the case of high-temperature types. In addition, temperatures around the housing should be within the range of 20 60. (In the case of products with sensor elements made of PVC, the temperature of fluids in the container is limited to 60.) Because explosion-proof products are pressure-resistant explosion-proof products, their cover should never be opened when they are in use. Explosion-proof products have been designed pursuant to Article 34 of the Industrial Safety and Health Act and Article 58-4 of the enforcement rules of the same act. Products that are not explosion-proof shall not be applied to explosion-proof regions. Explosion-proof products can be used only in places where the surrounding environment and fluids in the container are class 1 or 2. Warranty and contact number Warranty and service The warranty period of this product is two years after the shipment of the product, and service will be provided free of charge during this period for problems that have occurred during normal use. If service is requested for matters other than product issues, charges may be requested regardless of the warranty period. A/S may be requested through our home page or head office. Head office Factory Laboratory contact number Address : HITROL CO.,LTD 141, Palhakgol-road, Jori-eup, Paju-si, Gyeonggi-do, Korea TEL : 031-950-9700 (head office and A/S) FAX : 031-943-5600 (head office and A/S) Doc. no. : HR-30(EX) M_Eng_2015, Rev. 3 Issued date : 2016. 05 HR-30 M_Eng_2015 HITROL CO., LTD. 16