Armstrong Cool-Fog Systems

Similar documents
PRESSURE FOG HIGH ATOMIZING HUMIDIFICATION SYSTEM

High-Pressure Atomizing System

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Psychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart

HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems

THE SIX STEPS OF HUMIDIFICATION DESIGN

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

HIGH-PRESSURE ATOMIZING SYSTEM. Humidification and adiabatic cooling. Energy efficient Reduces cooling load Multiple zone capabilities

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

THE PSYCHROMETRIC CALCULATOR By: Stanley F. Gallos, The Bastian-Blessing Company INTRODUCTION PROPERTIES OF THE RSES CALCULATOR

ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall

Chapter 14, Problem 27.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

Atomizing Nozzle Humidifiers. Designed for Air Handling Systems, and Manufacturers, Processors and Distributors of Humidity Sensitive Products.

VENTURI NOZZLE SYSYTEM Specification Sheets ALL STAINLESS STEEL COMPRESSED AIR NOZZLE HUMIDIFIERS. With ON/OFF or Proportional Controls

R07. Answer any FIVE Questions All Questions carry equal marks *****

Humidification Systems Product Guide

Pharmaceutical Facility Design

Energy Recovery Ventilation

INTELLIGENT SOLUTIONS FOR ADIABATIC COOLING IN DATA CENTERS

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

OPTIMIZING PERFORMANCE IN SPRAY OPERATIONS

A660 Air Conditioning Laboratory Unit

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Thermodynamics II Chapter 6 Mixtures & Psychrometry

Reducing energy use, airstream heat gain, and condensate production

HVAC (Heating, Ventilating, and Air Conditioning)

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

GORD COOKE. issues associated with humidification and dehumidification systems. In this article, humidification

Steam Injection. Humidification system

Fundamentals of Psychrometrics. By James L. Murphy, Colorado Building Environments Sales Engineer

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Steam humidification: Reducing energy use, airstream heat gain, and condensate production

UNIT 1 AIR CONDITIONING 1. Write the various psychometric processes? Explain any four processes with neat sketches?

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

CHAPTER 4. HVAC DELIVERY SYSTEMS

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

ENGINEERING. Edition No. 13 October 2002

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

Energy Management and Controls

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

100% Outdoor Air Dehumidification Methods

Trane CDQ Desiccant Dehumidification

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Use this Construction/HVAC Glossary to answer the questions below.

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

Pressure Steam Humidifiers LS SERIES. humidity.com

Controlling Wrap-Around Heat Pipes for Systems with Strict Space Humidity Requirements. By Michael O. Davis, PE, August 2015

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Air Conditioning Clinic

2. CURRICULUM. Sl. No.

Reducing energy use, airstream heat gain, and condensate production

Insty-Pac Steam Humidifiers

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

ENCLOSURE COOLING. Glossary

AIR CONDITIONING. Carrier Corporation 2002 Cat. No


ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

Yarway Narvik Steam Desuperheater Series 4300 TempLow

EvaPack SERIES EVAPORATIVE PAD ADIABATIC HUMIDIFIERS

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

Temperature. In the HVAC area, we talk about two kinds of temperatures.

EVAPACK SERIES EVAPORATIVE PAD ADIABATIC HUMIDIFIERS

Air Conditioning and process cooling Energy Components at a Glance

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Designing Energy Efficient Outdoor Air Systems

Standards and Guidelines. Presented by: Aric Murray December 12, 2014

Cool, Clean and Comfortable Nortec HP-Series. Adiabatic In-Duct High Pressure Humidification System... Simply Awesome

Psychrometrics: The Science of Moisture in Air. Presented by Tom Peterson, CEO and Founder. Climate by Design International

NHS Sustainable Development: 14 th February Reduce Energy Consumption Through Steam System Modernisation. National Key Account Manager

TDSHS Air Change Requirements and the Basics of Psychrometrics. Presented by: Aric Murray December 06, 2013

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

Energy-Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Department of Mechanical Engineering ME 322 Mechanical Engineering Thermodynamics

H O B O K E N R E S I D E N T I A L

Optimizing Electric Humidifier Operation with an Air Side Economizer

How to ensure Thermal Comfort in buildings with CFD

: REFRIGERATION & AIR CONDITIONING COURSE CODE : 6023 COURSE CATEGORY : A PERIODS/ WEEK : 6 PERIODS/ SEMESTER : 90 CREDIT : 6 TIME SCHEDULE

Dehumidifying with Dedicated Outdoor Air

HUMIDIFIERS EXTRAORDINAIRE

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

Transcription:

Armstrong Cool-Fog Systems Armstrong International, Inc. is a leading supplier of hydropneumatic fogging systems used for both humidification and evaporative cooling. Its systems were first developed in response to industry needs for humidification systems that would be: Energy efficient Low maintenance Reliable Precisely controlled Clean Cool Fog Systems, Inc. installed its first hydro-pneumatic humidification system in 1977. Since then, Armstrong-Cool Fog Systems has established itself with professional engineers and industry as a viable and desirable technology. Armstrong-Cool Fog has humidified over million square feet of space including corporate occupancies, museums, hospitals, institutional facilities, and semiconductor fabrication, and electronics manufacturing. Armstrong currently manufactures and markets the following systems for environmental control applications: Cool Fog Systems (CF) for use with potable or reverse osmosis purified water. All wetted parts are either stainless steel, brass, or copper. For general commercial and industrial application. Pure Fog Systems (PF) for use with de-ionized water. All wetted parts are stainless steel. For clean rooms, laboratories, semiconductor fabs, and other ultra clean environments. Standard Proportional Systems (STD) for air handler or duct applications. Available as CF or PF. For reduced evaporation distance requirements with medium to high compressed air consumption rates and :1 control modulation. Variable Differential Control Systems (VDC) for air handler or duct application. Available as CF or PF. For reduced compressed air consumption rates and :1 control modulation. HumidiComp (HC), ON/OFF SYSTEMS for air handler or duct applications. Available as CF or PF. For reduced cost compared to STD and VDC. Systems. Only recommended for fixed outside air rates and stable humidification loads. Direct Area Discharge (DDF), ON/OFF SYSTEMS for direct area discharge. Available as CF or PF. Available from Armstrong Cool-Fog Armstrong-Cool Fog Systems offers a complete package of products and services: Fogger assemblies with manifolds Control systems - standard & custom Precise engineering design and application assistance Detailed energy analysis and design Submittal drawings Installation Instructions Operating and maintenance manuals Full warranty Commissioning services Maintenance contracts Packaged systems -Humidification -Controls -Compressed air supply -RO water supply Water analysis 1

What is Fogging? Armstrong-Cool Fog Systems are humidification systems that atomize water particles to produce a fog. When the fog is sprayed into a warm, dry air stream or space, the water readily evaporates without the addition of heat. The process is also referred to as evaporative humidification and follows the wet bulb line (i.e. constant enthalpy) on the psychrometric chart. Armstrong-Cool Fog Systems may also be used for the purpose of air-cooling. Because no heat is added to evaporate the water, there is a cooling effect that is directly proportional to the amount of water evaporated. This is also referred to as adiabatic or constant enthalpy cooling and humidification. How Foggers Operate Armstrong-Cool Fog Systems use both compressed air and pressurized water to achieve atomization. The mixture of atomized water and expanding air is discharged through an orifice and deflected off a resonator tip which further reduces the water particle size and spreads the atomized water and air mixture. The final product is fog. Compressed Air Figure 161-2. Fogger Head Pressurized water is injected into the discharge orifice of a compressed air stream. As the compressed air is discharged through an orifice, the air s potential energy is converted to kinetic energy, which is imparted to the injected water. In the process, the water is sheared into atomized water particles. In other words, the rapidly expanding air stream breaks up the water particles. Water Fog Particles Figure 161-1. rh (%) 9 8 7 Fogger Humidification Steam Humidification t(f) 6 7 7 8 8 9 9 Cooling 161

Features and Benefits 162 Humidification Reduces Heating Costs All forms of humidification provide a variety of benefits, not the least of which is a reduction in heating load for human comfort. Studies indicate people are generally most comfortable when relative humidity is maintained between % and %. When air is dry, moisture evaporates more readily from the skin, producing a feeling of chilliness even with temperatures of 7 F or more. Because human perception of RH is often sensed as temperature differential, it s possible to achieve comfortable conditions with proper humidity control at lower temperatures. The savings in heating costs are typically very significant over the course of just a single heating season. Efficient use of internal heat gain and waste heat can yield up to a 9% reduction of energy costs compared to steam humidification. Large commercial offices and manufacturing facilities can have an extended cooling season or year round cooling load. In such situations, a mixed air economizer system can be employed to exhaust warmer return air and replace it with cooler outside air. Although free cooling is achieved, the dryer outside air actually increases the humidification load and humidification energy consumption. Instead of exhausting the warmer return air, foggers use the warm return air to evaporate water. Humidification is achieved without the energy required to boil water and economizer cooling is still achieved without mechanical refrigeration. -% reduction of economizer humidification load and associated energy costs. Because of the cooling experienced with fogging systems, economizer systems can run at higher mixed air temperatures which means less outside air is required. Therefore, the humidification load is greatly reduced compared to the conventional steam humidification load. Efficient use of warm, dry outside air reduces cooling costs. Some outdoor climates require both cooling and humidification to achieve the desired indoor design conditions. Obviously, economizers cannot deliver free cooling when the outside air is warmer than the desired zone temperature. However, if the humidity levels are low, such as in the Western High Plains of the United States, significant free cooling may be achieved with an evaporative humidification system. This is true for both mixed air and % make-up air systems. If fact, many non-desert climates experience significant cooling and humidification hours each year. Ultra clean humidification source. Armstrong-Cool Fog s Pure Fog (PF) systems are currently installed in many of the world s highest technology electronics and semiconductor manufacturing facilities. De-ionized water is used for an ultra-pure source of humidification to maintain a non-contaminated environment. Highest Kinetic Energy. Armstrong-Cool Fog Systems use the highest air pressures of all high capacity atomizer systems. The result is the highest kinetic energy imparted to the water particles. Because Armstrong-Cool Fog Systems produce the highest energy particle, we have the highest evaporation efficiency. In other words, we evaporate more water per unit volume of water sprayed. This translates directly into the highest energy savings. This also results in less waste of purified water which, if not evaporated, goes down the drain. Highest kinetic energy also means the driest running system. Because Armstrong-Cool Fog Systems produce the highest energy particle, we have the shortest evaporation distances and have the driest running system of all high capacity atomizer systems. Energy savings with clean rooms. Clean room humidification typically requires ultra-pure (i.e. deionized or reverse osmosis filtered) water as a humidification source. As ultra-pure water is considered corrosive at elevated temperatures, all stainless steel components would be required for steam service. In many applications, a stainless steel re-boiler would be used to accomplish clean room humidification with ultra-pure water. Due to the inefficiencies of the heat exchange process, a Cool Fog system could be more energy efficient... even if % outside air is used. Reduced maintenance cost with no boiler or steam distribution system. Steam injection humidification, while similar to Cool Fog Systems in reliability and accuracy, can require more maintenance in the following areas: blowdown leaks traps scale carbonic acid chemical treatment Reduced maintenance and improved reliability over other evaporative systems. Traditional evaporative systems and other atomizing systems have many maintenance requirements that are not a concern with Armstrong-Cool Fog Systems. Swamp coolers require replacement of pads, cleaning & chemicals. Air washers require cleaning & chemicals. Low pressure air/water atomizers have moving parts in their nozzles that break. High pressure water atomizers (no compressed air) are prone to clogging of the orifice. Cool Fog manifolds come completely assembled, so less installation time is required. Instant and Precise Control Response. :1 turndown with standard proportional control :1 turndown with variable differential control no staging fast pneumatic response patented feedback system Quick and Easy Installation. simple design pre-assembled manifolds Highest Mechanical Integrity. As with everything Armstrong makes, quality is not compromised in order to produce a low priced system. Armstrong-Cool Fog Systems are made with both the sturdiest materials and design.

Potential Energy Savings Opportunities with Armstrong-Cool Fog Systems Due to the dry bulb cooling effect of evaporative humidification systems, substantial energy saving opportunities present themselves when compared to the cost of using steam for humidification. These opportunities are easily quantified using bin weather data. The estimated energy saving may be used to estimate the payback period for an investment in an Armstrong- Cool Fog System. Mixed Air System with Dry Bulb Economizer During the fall, winter, and spring economizer seasons, typical commercial air conditioning systems supply air to conditioned spaces at F. If the minimum outside air percentage is low enough, return air and outside air can be mixed to F, or higher, during most, or all, of the season without pre-heating. The typical maximum humidification load conditions occur when the outside air is F. At such conditions,% outside air is used for the free cooling effect. When the outside air temperature is between the supply air temperature and the building design temperature, % outside air is cooled to the supply air temperature. When the outside air temperature is above the building design temperature, outside air is reduced to the minimum percentage to minimize the cooling load. Energy savings potential may be realized in three ways with mixed air systems using a dry bulb economizer: 1. Latent Heat Recovery from Return Air. Due to the typical internal heat gain of commercial offices and manufacturing facilities, outside air and return air can be mixed to the required temperature for evaporative humidification without pre-heating. However, if minimum outside air requirements are high enough, pre-heating of the mixed air could be required on the coldest days. Therefore the energy savings for each temperature bin may be calculated as follows: + Cost of Steam - Additional Cost of Preheat (if any) - Cost of Air Compressor with Armstrong-Cool Fog = Latent Energy Savings The psychrometric representation of the process looks like this: (see Figure 163-1.) Figure 163-1. Latent Heat Recovery from Return Air Supply Air @ F rh(%) 9 8 7 Return Air From Zone @ 7F @ % RH % Min. Outside Air Mixed Air, 47.F Steam and Fogger Grain/Lb. Dry Air Outside Air @ -F & % RH Fogger Pre-Heat Point Steam Pre-heat Point t( F) 6 7 7 8 8 9 9 Additional Fogger Pre-Heat Steam Pre-Heat All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 163

Potential Energy Savings Opportunities with Armstrong Cool-Fog Systems, continued 2. Reduction in Humidification Load Due to their dry bulb cooling effect, Armstrong-Cool Fog Systems require that outside and return air are mixed to the wet bulb temperature of the supply air. Whereas, steam humidification systems require that outside air and return air are mixed to the dry bulb temperature of the supply air. The result is that less outside air is used with evaporative humidification, and therefore, the humidification load is also reduced. Therefore the energy savings for each temperature bin may be calculated as follows: Cost of Differential Increase in Humidification Load with Steam = Economizer Energy Savings The psychrometric process of the reduced humidification load is as follows: (see Figure 164-1.) Figure 164-1. Reduction in Humidification Load rh(%) 9 8 7 Return Air From Zone @ 7 F at % RH Supply Air @ F Fogging Mixed Air Outside Air @ F & % RH Steam Mixed Air (% OA) Fogger Grains/ Lb Dry Air Reduced Fogger Load Steam Grains/ Lb Dry Air t( F) 6 7 7 8 8 9 9 17 Btu/lbm Enthalpy Recovery with Fogging Btu/lbm 164

3. Mixed Air Cooling Savings Anytime the outside air temperature is both above the dry bulb temperature and below the dew point of the supply air, cooling savings may be realized. Therefore the energy savings for each temperature bin may be calculated as follows: +Cost of Differential Increase in Mechanical Cooling with Steam -Cost of Air Compressor with Armstrong-Cool Fog =Cooling Energy Savings The psychrometric representation of mixed air cooling savings is as follows. (see Figure 16-1, 166-1 and 167-1.) Figure 16-1. Mixed Air Cooling Savings Spring/Fall Economizer Mixed Air Supply Air @ F rh(%) 9 8 7 Return Air From Zone @ 7 F & % RH Mixed Air with Economizer Outside Air t(f) 6 7 7 8 8 9 9 Mechanical Cooling Required with Steam 16

Potential Energy Savings Opportunities with Armstrong-Cool Fog Systems, continued 3A. Mixed Air Cooling Savings Anytime the outside air temperature is both above the dry bulb temperature, and below the dew point of the supply air, cooling savings may be realized. Therefore the energy savings for each temperature bin may be calculated as follows: +Cost of Differential Increase in Mechanical Cooling with Steam -Cost of Air Compressor with Armstrong-Cool Fog =Cooling Energy Savings The psychrometric representation of mixed air cooling savings is as follows. (see Figure 16-1, 166-1 and 167-1.) Figure 166-1. Mixed Air Cooling Savings Spring/Fall Economizer % Outside Air Mechanical Cooling Required for Steam Mechanical Cooling Required for Fogging Cooling Savings Supply Air @ F rh(%) 9 8 7 Return Air From Zone @ 7 F @ % RH % Outside Air with Economizer t(f) 6 7 7 8 8 9 9 166

3B. Mixed Air Cooling Savings Anytime the outside air temperature is both above the dry bulb temperature, and below the dew point of the supply air, cooling savings may be realized. Therefore the energy savings for each temperature bin may be calculated as follows: +Cost of Differential Increase in Mechanical Cooling with Steam -Cost of Air Compressor with Armstrong-Cool Fog =Cooling Energy Savings The psychrometric representation of mixed air cooling savings is as follows. (see Figure 16-1, 166-1 and 167-1.) Figure 167-1. Mixed Air Cooling Savings Summer Cooling Minimum Outside Air Return Air From Zone @ 7 F @ % RH Supply Air @ F rh(%) 9 8 7 Fogger Discharge Air Mixed Air Point Outside Air t( F) 6 7 7 8 8 9 9 Cooling Savings Mechanical Cooling Required with Fogging Mechanical Cooling Required with Steam 167

Potential Energy Savings Opportunities with Armstrong Cool-Fog Systems, continued 4. % Make-up Air Cooling Savings In hot and dry climates with light heating season and extensive cooling and humidification season, substantial energy savings can be realized with evaporative cooling systems, even when % outside air is required. The potential energy savings for each temperature bin may be calculated as: + Cost of Differential Increase in Mechanical Cooling with Steam Humidification - Cost of Preheat (if any) - Cost of Air Compressor with Armstrong-Cool Fog = Cooling Energy Savings The psychrometric representation of the % outside air cooling savings is as follows: (see Figure 168-1) Figure 168-1. % Make-up Air Cooling Savings Supply Air @ F rh(%) 9 8 7 Return Air From Zone @ 7 F @ % RH Outside Air t( F) 6 7 7 8 8 9 9 Pre-heat Cooling Savings infiltration losses or cooling coil dehumidification. 168

. Pre-Cooling of Inlet Air for Air Cooled Water Coils or Gas Fired Turbines In hot and dry climates, evaporative pre-cooling of air cooled water coils for industrial process cooling or air conditioning can present the opportunity for substantial energy savings over mechanical refrigeration. Because the system is only used when excessive outdoor temperatures persist, no preheat is ever required. The energy saved for each temperature bin can be calculated as follows: +Cost of Equivalent Mechanical Cooling -Cost of Air Compressor with Armstrong-Cool Fog =Mechanical Cooling Savings The psychrometric representation of the water coil pre-cooling savings is as follows: (see Figure 169-1.) Figure 169-1. Pre-Cooling of Inlet Air for Air Cooled Water Coils or Gas Fired Turbines Cooled Inlet Air rh(%) 9 8 7 rh (%) Outside Air t( F) 6 7 7 8 8 9 9 Cooling Savings 169