NEBOSH International Technical Certificate in Oil and Gas Operational Safety

Similar documents
Emergency shutdown systems. Procedures for bypassing ESD s

(Material correct at 1/11/2011)

Fire Detection System: An Overview

InstrumentationTools.com

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

LEARNING SPECIAL HAZARD DETECTION TYPES

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

Explosion Protection Engineering Principles

Element IC3: Workplace Fire Risk Assessment. Fire Detection and Alarm Systems and Procedures

Meeting NFPA standards for

EXTINGUISHING SYSTEM DETECTION AND CONTROL

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

SEMICONDUCTOR FABRICATION FACILITIES

Safety Engineering. Fire Protection Systems and Life Safety Systems

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

Fire fighting Questions

DELUGE SYSTEMS FALSE OPERATIONS

Gas Detection in Process Industry The Practical Approach

Characterising the smoke produced from modern materials and evaluating smoke detectors

Element C3.4 Fire Fighting Equipment

WATER MIST CONVENTION AND EXHIBITION

Fire protection in hazardous locations:

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

Smoke detection in hazardous areas:

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

PRESSGUARD PDF-VERSION (ADJUSTED FROM BROCHURE) PRESS & HOT OIL PUMPS PROTECTION

RMS-I-DE-01 Smoke Detector

Contents. xiii. 4. PHYSICAL PROPERTIES OF HYDROCARBONS General Alkene Series... 28

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM

Introduction to Fire Detectors Training Manual

Fixed High Volume Water Spray System fireward.co.uk

Making sense of risk Risk engineering. Metalworking operations

ISO/TS TECHNICAL SPECIFICATION. Fire detection and alarm systems Part 9: Test fires for fire detectors

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

AS/NZS :2008

SECURITY BLANKET Foam Fire Protection Products

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 20: Aspirating smoke detectors

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

1 Exam Prep Fire Alarm Signaling Systems Tabs and Highlights

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

Water Mist Fire Suppression

Building Description Applicable Codes & Standards Prescriptive Requirements. Performance Based Design

Level 2 Award in Fire Safety (QCF) (SCQF Level 5 in Scotland) Unit 1 title: Fire safety principles

Protecting Ethylene Process Facilities: A Review of Gas Detection Methods

Monitoring Flammable Vapors and Gases in Industrial Processes

Fire Safety Basics II: Detection & Warning Systems

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Technical Information

NITOL INSURANCE COMPANY LIMITED

Application Note. Gas Turbines. Introduction. Market Segments

SOUTH AFRICAN NATIONAL STANDARD

T.ex Single Gas Detector VISA

Lamp Supply (Recommended)

Unit 1: Fire Engineering Science (A/505/6005)

The Science Behind Water Mist Protection of Typical Building Hazards

MODULE 2. Water-Based Suppression System Basics

IFE Level 4 Certificate in Fire Science and Fire Safety

Rosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

VQ500 Series Combustible Gas Detector Elements

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

Fire protection on chemical manufacturing sites

Australian/New Zealand Standard

INTERNATIONAL STANDARD

Minifog PressProtect Fire protection solutions for industrial presses BRANCH SOLUTION

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

Intelligent Signature Series Analog Detection

Water Spray Systems: NFPA 15

AGT 1 Confined Space. Authorised Gas Tester 1. Scienco Limited. Authorised Gas Tester 1 1

Active & Passive Fire Protection System. Page 1 Kalidasan S BT IN SSP-OP

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

Siansonic Technology Leading The Ultrasonic Technology

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

Intelligent. Signature Series Multisensor Detection. An EDWARDS brand.

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

Foam Products ENGLISH

MEDIUM-DENSITY HOUSING # 7. Fire safety

Checklist For Building Inspection & Fire Safety

LYOTRAP FREEZE-DRYING MACHINE OPERATING INSTRUCTIONS

contents iii Drilling Tools 27 Adjustable Choke 27 Automatic Drillers 29 MWD and LWD Tools 30 How They Work 30 Uses 30

ISO INTERNATIONAL STANDARD. Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements

PDF- VERSION ADJUSTED FROM THE BROCHURE. tissue. How to protect tissue mills from fire

HANDLING FLAMMABLE AND COMBUSTIBLE LIQUIDS ON DOCKS, PIERS AND WHARVES

Fire Prevention Plan for Alter Hall 3743 Ledgewood Drive

Transcription:

IOG1 - Element 4 - Fire protection and emergency response July 2012 NEBOSH International Technical Certificate in Oil and Gas Operational Safety Licence details RMS Publishing Victoria House, Lower High Street, Stourbridge DY8 1TA RMS Publishing. First Edition July 2012 All rights reserved. No part of this presentation may be stored in a retrieval system, reproduced, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without either the prior written permission of the Publishers. This presentation may not be lent, resold, hired out or otherwise disposed of by way of trade in any form other than that in which it is published, without the prior consent of the Publishers. Whilst every effort is made to ensure the completeness and accuracy of the information contained herein, ACT/RMS can bear no liability for any omission or error. Issued to: Single Licence Licence No: IOG1 Element 4 - First Edition - v.1.0 - Slide 1 IOG1 Element 4 - First Edition - v.1.0 - Slide 2 4 Fire protection and emergency response Learning outcomes 4.1 Outline appropriate control measures to minimise the effects of fire and explosion in the oil and gas 4.2 Outline the principles, procedures and resources for effective emergency response IOG1 Element 4 - First Edition - v.1.0 - Slide 3 IOG1 Element 4 - First Edition - v.1.0 - Slide 4 Content Content 4.1 Fire and explosion risk in the oil and gas 4.2 Emergency response 4.1 Fire and explosion risk in the oil and gas 4.2 Emergency response IOG1 Element 4 - First Edition - v.1.0 - Slide 5 IOG1 Element 4 - First Edition - v.1.0 - Slide 6 Sample of Powerpoint presentation for NEBOSH International Technical Certificate in Oil and Gas 1

Leak and fire detection systems Fire and gas detection systems in Oil and Gas installations are designed to mitigate unexpected events Designers need to know what is available in order to choose the correct systems for their plants There are two principal types of detector which are commonly in use in off-shore installations: 1) Heat, flame & smoke 2) Flammable gas instruments Infrared absorption combustible gas detection The technology uses the absorption characteristics of the hydrocarbon molecules to infra-red light This technology is more expensive than catalytic detection It is used for many applications Point infra red detectors record the gas concentration at the detector location They need to be placed where a release of gas is considered possible IOG1 Element 4 - First Edition - v.1.0 - Slide 7 IOG1 Element 4 - First Edition - v.1.0 - Slide 8 Infrared absorption combustible gas detection Infrared open-path gas detectors send out a beam of infrared light, detecting gas anywhere along the path of the beam This linear sensor is typically a few metres up to a few hundred metres in length An open path detector usually costs more than a single point detector The open path detector excels in outdoor situations Infrared point gas detector IOG1 Element 4 - First Edition - v.1.0 - Slide 9 IOG1 Element 4 - First Edition - v.1.0 - Slide 10 Catalytic gas detectors Catalytic detectors rely upon burning gas in a sintered chamber For this reason they are only available as a point detector or as part of a multi-point aspirating system Toxic gas detection Technologies available include chemical cell and semiconductor point detectors Many different types of gas can be detected IOG1 Element 4 - First Edition - v.1.0 - Slide 11 IOG1 Element 4 - First Edition - v.1.0 - Slide 12 Sample of Powerpoint presentation for NEBOSH International Technical Certificate in Oil and Gas 2

Leak detection Leak detection Leak detection may not be considered to be part of the fire and gas detection system Leak detection is often regarded as a supervisory or maintenance facility, or an adjunct to the fire and gas system by using them in conjunction with other detection methods Ultrasonic leak detectors Devices are available for detecting the sound of leaks at ultrasonic frequencies Mainly used for outdoor environments where weather conditions can easily dissipate IOG1 Element 4 - First Edition - v.1.0 - Slide 13 IOG1 Element 4 - First Edition - v.1.0 - Slide 14 Fire detection Smoke detection Infrared (IR) flame detectors The detector relies on infrared radiation produced by flames Ultra-violet (UV) flame detectors These detectors rely on the effective detection of ultra-violet radiation produced by flames Point smoke detectors Detect smoke at a fixed point They need to be placed where smoke realistically could travel in the event of a fire IOG1 Element 4 - First Edition - v.1.0 - Slide 15 IOG1 Element 4 - First Edition - v.1.0 - Slide 16 Smoke detection Heat detection Ionisation point smoke detectors These detectors use a small radioactive source and detect decreased conduction caused by the ionisation of smoke particles in a detection chamber Optical point smoke detectors These detectors generally detect smoke particles inside a chamber by an increase of light scatter caused by smoke particles or by the smoke particles obscuring a light beam Heat detection is used where ambient temperatures or environment preclude the use of smoke detection IOG1 Element 4 - First Edition - v.1.0 - Slide 17 IOG1 Element 4 - First Edition - v.1.0 - Slide 18 Sample of Powerpoint presentation for NEBOSH International Technical Certificate in Oil and Gas 3

Heat detection Passive fire protection Point heat detection These detect high temperatures at a given point They are still commonly described as Rate of rise, and fixed heat detectors Example uses include: kitchens, turbine hoods Linear (line) heat detectors These detectors detect heat somewhere along the length of the device Example uses include: tank rim seals; cable tunnels Types of PFP Spray coatings Enclosures Fireproof cladding Seals and sealants Cable coating Fire walls Compartmentalisation IOG1 Element 4 - First Edition - v.1.0 - Slide 19 IOG1 Element 4 - First Edition - v.1.0 - Slide 20 Active fire protection Active fire protection systems such as water sprinkler and spray systems are widely used in the process for protection of storage vessels and process plant The duty of the fire protection system may be to extinguish the fire, control the fire, or provide exposure protection to prevent domino effects Systems can be fixed (for example, deluge or sprinkler systems) or portable (extinguishers) Fixed water based systems A source of water: sea water, tank, river, wells A pump: designed to deliver at the required flow rate and pressure, with quick or automatic activation Fire water mains: a piping system to transport the water from the pump to where it is needed (for example, fire hydrants, risers, sprinkler heads) Water systems primarily operate by cooling the fire Suitable environments containing solid combustible materials (class A fires) IOG1 Element 4 - First Edition - v.1.0 - Slide 21 IOG1 Element 4 - First Edition - v.1.0 - Slide 22 Fixed foam systems Similar to fixed water based systems, except that a foam concentrate is injected into the fire water system from a separate vessel Foam is a stable mass of small, air-filled bubbles that have a lower density than oil, petrol, or water Foam can be used on fire involving solid combustible materials and is highly effective on flammable liquid fires (for example: hydrocarbon fuel fires) Fire monitor converted for foam use IOG1 Element 4 - First Edition - v.1.0 - Slide 23 IOG1 Element 4 - First Edition - v.1.0 - Slide 24 Source: Williams Fire & Hazard Control Sample of Powerpoint presentation for NEBOSH International Technical Certificate in Oil and Gas 4

Foam monitor: may be used to protect tanks or jetties Sprinkler systems The purpose of an automatic sprinkler system is to detect the fire, extinguish or control the fire and to raise the alarm Each sprinkler head will open when it reaches a specific temperature and spray water on to a fire Source: Narfoam Kar Company. IOG1 Element 4 - First Edition - v.1.0 - Slide 25 IOG1 Element 4 - First Edition - v.1.0 - Slide 26 Deluge systems Deluge water spray systems are similar to sprinkler systems, except all nozzles are open and will discharge together when the system is activated Water mist systems Water mist is a fine spray with 99 percent of water volume contained in water droplets less than one millimetre (1,000 microns) in diameter IOG1 Element 4 - First Edition - v.1.0 - Slide 27 IOG1 Element 4 - First Edition - v.1.0 - Slide 28 Dry powder installations (chemical) Dry powders, in common with vaporising liquids, offer the advantage of a quick knock-down of fire, but unlike vaporising liquids, they have negligible toxic effects A dry powder installation consists of dry powder containers linked by pipework to discharge nozzles covering the areas of risk Part only of the complete Element 4 - Fire protection and emergency response IOG1 Element 4 - First Edition - v.1.0 - Slide 29 IOG1 Element 4 - First Edition - v.1.0 - Slide 30 Sample of Powerpoint presentation for NEBOSH International Technical Certificate in Oil and Gas 5