Product Catalog. Ultrasound Leak Detection and Condition Based Monitoring

Similar documents
October Airborne & Structure-Borne Ultrasound as a key component to Predictive Maintenance

NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In?

Model R9100. REED Instruments Instruction Manual. Ultrasonic Leak Detectortor

i-alert Monitoring Solution Sensor App Ai Platform

Energy Conservation and Equipment Reliability With Ultrasound

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

Whisper. Ultrasonic Leak Detector

SONOCHEK The ultrasonic testing device

Tru Pointe Ultra Ultrasonic Leak Detector

Enhancing Current Maintenance Practices 04. Managing the Risk 06. Constant Monitoring of Electrical Enclosures 08

EN-ENGLISH INSTRUCTION MANUAL. METPOINT LKD 300 Leak Detector (LD109) For leak detection in pneumatic systems.

EAGLE: Smart Wireless Solution. Condition monitoring installation has never been so easy. Brand of ACOEM

SONAPHONE E. ATEX Certificated for the Use in Areas with Risk of Explosion. Features:

Lutron GS-5800 ULTRASONIC GAS LEAKAGE DETECTOR

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

FUNCTIONAL SAFETY MANUAL

Itron Water Loss Management Solutions. Advanced Digital Leak Detection Overview Session

Delta T Alert: Wireless Temperature Monitoring of Electrical Enclosures

GS Model. Instruction Manual. Ultrasonic Leak Detector. reedinstruments. www. com

Your computer system is the lifeblood of your business. Cyber threats are. what you hear most about today. Hacks, viruses and spyware get constant

Ultrasound Solutions. Time to enhance your maintenance programme.

Innovative Industrial Solutions, Inc Skyline Drive Russellville, AR 72802

LEADING THE INDUSTRY THROUGH INNOVATION. UNILINC TM CONTROL SYSTEM

Remote Monitoring of Offshore Structures using Acoustic Emission.

Successful Applications Using ISA100 Wireless Technology

Who we are... What we do... How we work with you...

PROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS

WG Railway Security Protection System

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

Wireless 0-5 Volt Meter Sensor

ULTRASONIC TESTING DEVICE LEAK DETECTION AND CLASSIFICATION STEAM TRAP INSPECTION VALVE INSPECTION TIGHTNESS TESTING DETECTION OF PARTIAL DISCHARGES

FUNCTIONAL SAFETY MANUAL

A WORLD WITHOUT DOWNTIME

condition monitoring & machinery diagnostics

Enabling IoT in Existing Plants

Frequently asked questions: Intelligent Transmitter Series

White Paper. Maintenance Inspection Windows on Transformers. Maintenance Inspection Windows on Transformers. Abstract: iriss.com

VENDED. Speed Queen. Front Load Washers

IoT use cases for smart building. IoT is changing the way facility management, security and construction companies are operating.

Train Conformity Check System TCCS

SENSAPHONE 901 Tryens Road Aston, PA PH:

VT-3-1 VERTICAL THERMOFORMER

SMARTWALK DEMENTIA WANDERING SYSTEM

User Detection Sensors

Crime Central Station Burglary Alarm Systems

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

Aquarius - Spectrum. multi-layer acoustic water pipe monitoring solutions. Game changer in water network management

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek

Summary. Assessment Methodology

User Manual for ULTRASCAN High Pressure Leak and Corona Discharge Detector

THE INDUSTRIAL APPROACH TO DUST MONITORING

THE EDDY IQ METER PRODUCT MANUAL

EVERY SECOND COUNTS CONNECTED SAFETY SOLUTIONS

ULTRASCHALLPRÜFGERÄT ULTRASONIC TESTING DEVICE LEAK DETECTION AND CLASSIFICATION

The New Device Class for Preventive Maintenance

Part Number Structure ZT 028 L D CT R 15

Gear Unit Condition Monitoring. Portfolio overview

Why are infrared cameras indispensable for building inspections?

Your specialist partner for total electrical compliance. Electrical Testing

Smart Wireless Sensor

Application Note. Technique description CPB measurements give early fault detection with minimal risk of false alarms

Case Study. Detecting Vacuum Leaks in a Multi Effect Evaporator Using Ultrasound Detection

GASSONIC Ultrasonic Gas Leak Detection. How fast does your Gas Detection System detect leaks? Because every life has a purpose...

Smart Wireless Sensor

Hunting the Mighty Milliwatt- The next Technology Step

Affordable wireless monitoring without compromise

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

NFEC FIRE SAFETY SEMINAR Krish Mysore

Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT

PRESENTS AQUADUCT AUTOMATED WATER-LEAK MONITORING SYSTEM A KINGPIN TECHNOLOGY

Vacuum Pump Vacuum Pump

Safety Standards for Electronic Products

DASPOS A/S Gammel Klausdalsbrovej Herlev Denmark Tel.: website: DASPOS USA, Inc NE 116th Street, PMB

Numerical Standards Listing

The WAVE Plus Instant Notification System for Schools and Colleges

Affordable wireless monitoring without compromise

Radar technology in surveillance

Condition monitoring using FAG products. Technical Product Information

1.1 DESCRIPTION A. The purpose of this section is to specify Division 23 responsibilities in the commissioning (Cx) process.

CASE HISTORY#1 BAD COOLING TOWER GEARBOX? Barry T. Cease Cease Industrial Consulting (843)

Keeping Chillers Efficient - Archives - Energy and Power Management

Preliminary Operations and Maintenance Plan Baron Winds Project

PIP PCTPA001 Testing of Process Analyzer Systems

ADVANCED MONITORING AND DIAGNOSTIC SYSTEMS FOR INDUSTRIAL GAS TURBINES

VIBRA-series: VIBRA, VIBRA +

Central Monitor. Central Monitoring System. Intuitive, Reliable, Flexible CNS-9601K. Shown with options

Product Application Guide- Industrial Alarms

Speed and Frequency Seite 1 von 7

A Powerful Case for Infrared Windows

Steam Trap Inspection Methods And Steam Cost Analysis

WHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE

How to spot and address potential process problems using thermal imaging

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

Independent Living without Leaving Home. Personal Emergency Reporting Systems from Linear

GM Ultrasonic Gas Leak Detection Gas Detection at the Speed of Sound. How fast does your Gas Detection System detect leaks?

Engineering Design & Testing Corp./EDT Engineers, P.C.

Monitoring of Electrical Equipment Failure Indicators and Alarming

Surface Acoustic Wave Technology based Temperature Monitoring of High Voltage and High Current Switchgear Boxes

This Chapter Sponsored by CASTOOL Tooling Solutions

Soon. CELL682 Wireless Alarms WSG30. NEW for. Coming

Transcription:

Product Catalog Ultrasound Leak Detection and Condition Based Monitoring

CTRL UL101 Ultrasound Receiver 40 khz Ultrasonic Analog Meter Microphone Output Switch (Meter/Battery) Gain Switch (Sensitivity) Potentiometer (Sensitivity/On/Off) Ruggedized Alumimum Housing Solid State Electronic Board Headset Jack (Output) 9-Volt Battery UL101 Ultrasound Detector Benefits (45-50 Hours) Finds all turbulent flow leaks Most sensitive detector on the market today for compressed air/gas, vacuum, valve, etc. leak detection. Easier to use Turn the receiver on, adjust sensitivity, and begin testing. Does not require calibration Begin testing immediately. There is no need to calibrate or routinely send back to the factory. Longer battery life A single, 9 Volt battery powers the receiver for more than 45 continuous hours. Complements vibration analysis or infrared Add the UL101 to your predictive maintenance routines for instant feedback. Designed for a wide range of applications Leak detection, mechanical & rotating equipment tests, electrical arcing & corona discharge detection Standard or intrinsically safe models Intrinsically safe models can be used in explosive atmospheres Intrinsically Safe: ANSI/UL 91 3-88, for DIVISION 1, CLASS I, Groups A, B, C and D, CLASS II, Groups E, F, G and CLASS III. It also complies with DIVISION 2, CLASS I, Groups A, B, C and D, CLASS II, Groups F, G, and CLASS III

CTRL UL101 Ultrasound Detector Kit UL101 Ultrasound Detector Technology The CTRL UL101 detects and converts ultrasound produced by mechanical, pneumatic, hydraulic, and electrical systems. Changes in the amplitude and characteristics of the ultrasound are easily detected in noisy plant environments. Leaks are easily pinpointed. Equipment problems are diagnosed even earlier than other technologies such as vibration, infrared inspection, or oil analysis. UL101 Ultrasound Detector Applications Leak Detection Indicate and locate pressurized and nonpressurized system leaks of any type of gas Motor Bearings & Gearboxes Dianose critical mechanical equipment for production reliability and proper lubrication Valves & Steam Traps Detect internal by pass leaks and diagnose proper operation conditions Electrical Inspection Detect arcing, tracking, and corona discharge in low, medium, or high voltage Specifications Dimensions: Receiver: 8.75 x 1.26 x 1.26 (222 x 32 x 32 mm) Transmitter: 4.125 x 1.26 x 1.26 (105 x 32 x 32 mm) Weight (including battery): Receiver: 11.6 oz (330 g) Transmitter: 6.2 oz (175 g) Housing: Extruded Aluminum, wall thickness.09 (2.3mm) Power Supply: 9 Volt Alkaline Battery Life: Receiver: > 45 hours Transmitter: > 300 hours Distance of Reception: Up to 150 feet (without PowerBeam300) Receiver Threshold of Sensitivity: Minimum Intensity: 10 12 W/m2 Minimum Ultrasonic Pressure: 2.0 x 10 5 PA @ 40 khz Frequency Bandwidth: 1.8 2.2 khz @ level 0.7 (or 3 db) Working Resonance Frequency: 40 khz +/ 1.5 khz Operating Temperature Range: 4 to +130 F ( 20 to +54 C) Headset: Industrial Grade/600 Ohm Impedance 21 24 db Ext. Noise Attenuation Warranty: 1 year parts & labor Extended warranty available

CTRL UL101 for CBM Ultrasound Condition Based Monitoring Not Pictured: SoundCTRL with PDA, Carrying Case, David Clark Headset, Operator's Manual, Training CD Condition Based Monitoring Under Lubrication When bearings lose their lubrication, the first indication is through ultrasound. The RMS (overall average amplitude) level rises dramatically. A comparison to the bearing's history and a previously set baseline will send an automatic email notification for call to action. Over Lubrication Likewise, when a bearing has too much lubrication, the RMS is used to indicate that no ultrasound is being produced. InCTRL is a Web Based Application with Secure Access to Data From Anywhere Excessive Wear As a bearing shows signs of wear, the subtle impacts are amplified and clearly indicated with CTRL's unique algorithms that help identify "Events Per Second" (EPS). The software compares changes to EPS and RMS with the bearing's history and identifies the current condition as suspect or questionable. Replacement of the bearing can be scheduled during routine shutdown without fear of catastrophic failure. Other Mechanical Operations Any mechanical equipment produces ultrasound, for which the UL101 together with the software can provide immediate, historical, and comparative analysis to assess the condition. Changes to any condition from the "norm" are apparent.

Software for CBM SoundCTRL & InCTRL for Analysis, Trending, Reporting, Etc. InCTRL Features Web based Access ultrasound test data from the Internet Wireless Uploads Upload ultrasound samples wirelessly from SoundCTRL Flags & Sends Email Alerts Flags and sends alerts when amplitude exceeds set threshold Bearing Health Assessments Responses include: under lubricated, normal, suspect, questionable Stack & Overlay Ultrasound Waveforms Detect early signs of equipment wear Trend Ultrasound Data Plot root mean square calculations overtime SoundCTRL with SocketMobile SoMo 655 Standard PDA for Data Acquisition and Real Time Assessment Reporting Create reports for cost justification, meetings and longterm planning Multiple Location Deployment Corporate wide implementation Share Data Share data with other departments or with multiple plants around the world

InCTRL CBM Software Package Condition Based Monitoring Software Trend Ultrasound Data PDA w/ Touch Screen Analyze Amplitude Assess Bearing Health Conditions Track Changes Compare Wave Files RMS Measurement (Root Mean Squared) EPS Measurement (Events Per Second) Real-Time Waveform Display Identify Location & Test Point Wireless Upload To Server Instant Feedback For Analysis The First Step to Predictive Maintenance to Reduce Production Downtime! InCTRL is used for condition based monitoring to record and analyze the output from the UL101. The recordings are uploaded to a server to establish thresholds and for future comparisons of the test point. Once a baseline or benchmark signal of a component is recorded, future recordings may be compared in order to determine the wear or proper lubrication of the component over time. If there are anomalies as indicated by the "EPS" (Events Per Second) calculation or the "RMS" (average amplitude) value has climbed beyond the threshold, the testpoint will be indicated as flagged. Instantly see, hear, monitor & diagnose Bearings, Gears, Pumps, Valves, & Cylinders Comparison Analysis Compare ultrasound readings of similar equipment. Baseline Analysis Set a baseline and trend the ultrasound readings over time, looking for changes Threshold Set the RMS threshold level; get an e mail alert when RMS rises too high Bearing Health Assessment InCTRL indicates if bearing is "normal", "under lubricated", "suspect", or "questionable" FFT for Electrical Inspection Harmonics, RMS, & EPS help indicate mechanical looseness, corona, or arcing

InCTRL CBM Software Package Condition Based Monitoring Software UL1 01 CBM Package Standard Model (p/n 0001 01 ) CTRL Intrinsically Model Safe Part # Part # NSN No 0001 01 Kit Components Part # Part # NSN UL1 01 Full Kit (Standard Model) 000031 SoundCTRL Software for Data Acquisition 00001 0 InCTRL Dedicated Account 041 000 InCTRL Monthly Subscription 041 006 or InCTRL Yearly Subscription 041 005 On-Site Training & Implementation Options 1 1 /2 Days On-Site 090030 2 1 /2 Days On-Site Certified Level 1 090050 UL1 01 CBM Package Intrinsically Safe* Model (p/n 0001 02) CTRL Intrinsically Model Safe Part # Part # NSN Yes 0001 02 Kit Components Part # Part # NSN UL1 01 Full Kit (Intrinsically Safe Model) 000033 6635 01 587 1 093 SoundCTRL Software for Data Acquisition 00001 0 InCTRL Dedicated Account 041 000 InCTRL Monthly Subscription 041 006 or InCTRL Yearly Subscription 041 005 On-Site Training & Implementation Options 1 1 /2 Days On-Site 090030 2 1 /2 Days On-Site Certified Level 1 090050 *The CTRL UL1 01 Full Kit (p/n 000033) is certified by CTRL as Intrinsically Safe: ANSI/UL 91 3-88, for DIVISION 1, CLASS I, Groups A, B, C and D, CLASS II, Groups E, F, G and CLASS III. It also complies with DIVISION 2, CLASS I, Groups A, B, C and D, CLASS II, Groups F, G, and CLASS III

CTRL UL101 Full Kit Airborne Ultrasound: Leak Detection, Electrical Inspection Not Pictured: Carrying Case, David Clark Headset, Operator's Manual, Training CD CTRL UL101 More Than A Leak Detector Ultrasound detectors designed with the right technology and software can be used for condition monitoring and predictive maintenance. Using the UL101 regularly will minimize production downtime, improve quality control and safety, and decrease man hours by improving troubleshooting capabilities. The CTRL UL101 ultrasound detector is capable of accurately interpreting the sounds created by under lubrication, over lubrication, and early signs of wear. The right ultrasound technology is a fast and effective means of determining such conditions in moving, mechanical components such as bearings, gearboxes, motors, compressors, etc. Valve Inspection Save money by locating internal by pass leaks with a single point inspection. Motor Bearing & Gearbox Diagnostics Quickly identify bad bearings, even before vibration or heat occurs. Quality Control Develop test procedures that reduce waste and improve performance. Non-Pressurized Vessel Testing Use the Ultrasound Transmitter to test the weld beads and gaskets of vessels without pressurizing.

CTRL UL101 Full Kit UL1 01 Full Kit Standard Model (p/n 000031 ) CTRL Intrinsically Model Safe Part # Part # NSN UL1 01 -E No 000031 Kit Components Part # Part # NSN UL1 01 Receiver (Standard Model) 026005 1 001 5 6635 01 270 6829 UT2000 Universal Transmitter (Standard Model) 02601 0 201 08 6625 01 270 6828 David Clark Headset 02501 0 301 01 5965 01 270 6832 Carrying Case 02001 5 301 00 6625 01 270 6830 1 -inch Acoustic Probe 070035 6635 01 579 6899 Acoustic Extension Probe Set (5 Pieces) 000005 1 01 1 4 5355 01 270 6833 Solid Probe Set (4 Pieces) 000050 Concentrator Set (3 Pieces) 000065 6635 01 579 6932 Operator's Manual 00501 0 Training CD 005025 TO 33D7-22-50-1 * UL1 01 Full Kit Intrinsically Safe Model (p/n 000033) CTRL Intrinsically Model Safe Part # Part # NSN UL1 01 -ISE Yes 000033 6635 01 587 1 093 Kit Components Part # Part # NSN UL1 01 Receiver (Intrinsically Safe Model) 026007 6635 01 578 7933 UT2000 Universal Transmitter (Intrinsically Safe Model) 02601 2 David Clark Headset 02501 0 301 01 5965 01 270 6832 Carrying Case 02001 5 301 00 6625 01 270 6830 1 -inch Acoustic Probe 070035 6635 01 579 6899 Acoustic Extension Probe Set (5 Pieces) 000005 1 01 1 4 5355 01 270 6833 Solid Probe Set (4 Pieces) 000050 Concentrator Set (3 Pieces) 000065 6635 01 579 6932 Operator's Manual 00501 0 Training CD 005025 TO 33D7-22-50-1 * *TO assigned by U.S. Air Force Intrinsically Safe: ANSI/UL 91 3-88, for DIVISION 1, CLASS I, Groups A, B, C and D, CLASS II, Groups E, F, G and CLASS III. It also complies with DIVISION 2, CLASS I, Groups A, B, C and D, CLASS II, Groups F, G, and CLASS III GSA Contract Number: GS-06F-0001 N Cage Number: 62373

CTRL UL101 Air Audit Kit Airborne Ultrasound: Leak Detection, Electrical Inspection Not Pictured: Carrying Case, David Clark Headset, Operator's Manual, Training CD Ultrasound Leak Detector The CTRL UL1 01 Air Audit Kit includes attachments for airborne ultrasound applications including leak detection (any type of gas), vacuum leak detection, electrical inspection, and steam leak detection. Additionally, the kit includes a single 3-inch solid probe for diagnosing steam traps and valves by detecting internal by-pass leaks. The Air Audit Kit can be expanded to a Full Kit by purchasing the UT2000, additional solid probes, and the SoundCTRL/InCTRL software. Leak Detection Compressed Air For Energy Savings Leaks account for 20% 30% of the energy usage of a compressor. HVAC Ultrasound is not affected by wind. Expensive Gas (Any Type) Finding one Nitrogen leak has immediate ROI. Steam Leaks Improve steam system efficiencies and save money.

CTRL UL101 Air Audit Kit UL1 01 Air Audit Kit Standard Model (p/n 000036) CTRL Intrinsically Model Safe Part # Part # NSN UL1 01 -SA No 000036 Kit Components Part # Part # NSN UL1 01 Receiver (Standard Model) 026005 1 001 5 6635 01 270 6829 - no transmitter David Clark Headset 02501 0 301 01 5965 01 270 6832 Carrying Case 02001 5 301 00 6625 01 270 6830 1 -inch Acoustic Probe 070035 6635 01 579 6899 Acoustic Extension Probe Set (5 Pieces) 000005 1 01 1 4 5355 01 270 6833 3-inch Solid Probe 040045 6635 01 579 6901 Concentrator Set (3 Pieces) 000065 6635 01 579 6932 Operator's Manual 00501 0 Training CD 005025 TO 33D7-22-50-1 * UL1 01 Air Audit Kit Intrinsically Safe Model (p/n 000038) CTRL Intrinsically Model Safe Part # Part # NSN UL1 01 -ISA Yes 000038 000038 6635 01 534 251 2 Kit Components Part # Part # NSN UL1 01 Receiver (Intrinsically Safe Model) 026007 6635 01 578 7933 - no transmitter David Clark Headset 02501 0 301 01 5965 01 270 6832 Carrying Case 02001 5 301 00 6625 01 270 6830 1 -inch Acoustic Probe 070035 6635 01 579 6899 Acoustic Extension Probe Set (5 Pieces) 000005 1 01 1 4 5355 01 270 6833 3-inch Solid Probe 040045 6635 01 579 6901 Concentrator Set (3 Pieces) 000065 6635 01 579 6932 Operator's Manual 00501 0 Training CD 005025 TO 33D7-22-50-1 * *TO assigned by U.S. Air Force Intrinsically Safe: ANSI/UL 91 3-88, for DIVISION 1, CLASS I, Groups A, B, C and D, CLASS II, Groups E, F, G and CLASS III. It also complies with DIVISION 2, CLASS I, Groups A, B, C and D, CLASS II, Groups F, G, and CLASS III GSA Contract Number: GS-06F-0001 N Cage Number: 62373

CTRL UL101 Corona Kit UL101 Receiver, Headset, & PowerBeam 300 Not Pictured: Carrying Case, David Clark Headset, Operator's Manual, Training CD Power Distribution & Transmission Has A Cost-Effective Solution! Leaking or tracking voltage can be serious at any specific temperature rise and special provisions should be taken to determine the severity. Load demands and the critical nature of particular components should also be considered while determining severity. It is important to document all inspection routes for familiarization of all components inspected, as well as identify systems unable to be tested due to lack of electrical load or lack of access. Using the CTRL UL101 Corona Kit provides an affordable, effective solution to reducing transmission loss and outages. Predictive Early detection of corona discharge, tracking, & arcing Accurate Detect problems when no heat is present; used with or without infrared Safety Inspect from great distances. There is no need to open electrical panels. Costs 10 to 20 times less than a corona camera.

CTRL UL101 Corona Kit UL1 01 Corona Kit Standard Model (p/n 000041 ) CTRL Intrinsically Model Safe Part # Part # NSN UL1 01 -PB No 000041 Kit Components Part # Part # NSN UL1 01 Receiver (Standard Model) 026005 1 001 5 6635 01 270 6829 - no transmitter David Clark Headset 02501 0 301 01 5965 01 270 6832 Carrying Case 020030 PowerBeam 300 007005 Operator's Manual 00501 0 PowerBeam 300 Operator's Manual Training CD 005025 TO 33D7-22-50-1 * PowerBeam 300 (p/n 007005) Extended Range Attachment for UL101 Receiver CTRL Intrinsically Model Safe Part # Part # NSN PowerBeam 300 No 007005 Kit Components Part # Part # NSN PowerBeam 300 007005 Carrying Case 020030 PowerBeam 300 Operator's Manual Extends range of detection of UL1 01 Receiver to 300 Feet! The PowerBeam 300 accurately pinpoints source of ultrasound to within 1 degree from center and improves the sensitivity of the UL101. The "PB300" was originally designed for the indication and location of corona discharge and arcing on medium/high voltage transformers. The PB300's ability to pinpoint ultrasound is very useful when finding compressed air/gas or steam leaks in pipes located on high ceilings. There is no need to get a ladder or scissor lift. Power Transmission Corona discharge is a major contributor to energy loss and also Radio Frequency Interference Electrical Inspection Arcing indication that a failure has occurred Tracking detectable even when infrared cannot Leak Detection Find leaks from further away and pinpoint to exact source without use of a scissor lift. Steam Leaks/Traps Detect leaks and operation from a safe distance. GSA Contract Number: GS-06F-0001 N Cage Number: 62373

CTRL Ultrasound Training Product Training & Implementation Ultrasound Certified Training Level 1 (p/n 090040 or 090050) Scope CTRL Systems Inc. level 1 certification uses parts of ISO 29821 and ISO 1 8436 to outline methods and requirements for carrying out condition monitoring and diagnostics of machines using scan mode and contact mode ultrasound to provide measurement, data interpretation, and assessment criteria. These techniques are typically carried out on operating machinery under a range of conditions and environments. CTRL's ultrasound detector is a passive technology that detects acoustic anomalies produced by machines. The skills and expertise of the practitioner performing the measurements and analyzing the data are critical to the effective application of ultrasound. A practitioner of ultrasound, with knowledge based and practical training should be able to develop proper techniques to incorporate methods and procedures that lead to reliable and repeatable ultrasound inspection results. Training Options Part # Part # NSN 3 Days Ultrasound Certified Training Level 1 090040 Per Person at Scheduled Training Course in a Designated City Contact CTRL Systems for a List of Dates and Locations 3 1 /2 Days On-Site Ultrasound Certified Training Level 1 090050 Max: 1 0 Persons Per Class 1 1 /2 Days On-Site Ultrasound Training (p/n 090030) Scope CTRL will spend 1 1 /2 days on-site to provide a comprehensive training program that includes extensive classroom training as well as hands-on equipment training. This program was designed to bring the classroom to you while providing input and practice on your equipment. We train up to 1 0 people per class at your facility. A review of the benefits of ultrasonic inspection and the basic principals of ultrasound Demonstrations of how the technology can be used for a wide variety of applications Tips and techniques for determining the condition of critical bearings, pinpointing gas leaks, air leaks and more Hands-on experience with ultrasound technology in your facility with your equipment Set up of InCTRL & SoundCTRL Software including establishing baselines on critical equipment Identify procedures & steps to integration Train up to 1 0 people in 1-1 /2 days Training Options Part # Part # NSN 1 1 /2 Days On-Site Ultrasound Training 090030 Max: 1 0 Persons Per Class

CTRL Ultrasound Training Product Training & Implementation 1 /2 Day On-Site Ultrasound Training (p/n 090020) Scope Half day training is designed to help your organization implement ultrasound as quickly as possible. Learn the basics of ultrasound detection and how it applies to your facility through hands-on operation of CTRL Ultrasound Products & Programs. We train up to 1 0 people per class on-site. A review of the benefits of ultrasonic inspection and the basic principals of ultrasound Demonstrations of how the technology can be used for a wide variety of applications Tips and techniques for determining the condition of critical bearings, pinpointing gas leaks, air leaks and more Quick start training for up to 1 0 people in 1 /2 day Training Options Part # Part # NSN 1 /2 Day On-Site Ultrasound Training 090020 Max: 1 0 Persons Per Class On Site Training & Implementation Enables Our Clients to Learn and Integrate the Maximum Potential Savings Opportunities for Ultrasound Condition Based Monitoring

What Can CTRL Systems, Inc. Do For You CTRL Systems, Inc. is a designer and manufacturer of ultrasound detection systems for maintenance. Manufacturers face many challenges, such as extending the life and improving the performance of equipment. It is sometimes necessary to do these things with limited resources less personnel, less time, and more demands. A good predictive maintenance, energy savings, and quality control program can prevent unexpected failures, downtime, and waste. CTRL's ultrasonic technology provides an efficient and cost effective method for monitoring critical equipment and leak detection. Frequent inspection, documentation, and trending are crucial for an effective program. CTRL can work closely with your organization to provide a seamless integration of ultrasound technology into current processes for the maximum level of ROI and satisfaction. CTRL Systems, Inc. 1 004 Littlestown Pike, Suite H Westminster, MD 211 57 USA ph. (41 0) 876-5676 fax. (41 0) 848-8073 www. ctrlsys. com