Smoke control in car parks

Similar documents
FAÇADE FIRE TESTS Towards a new European standard method

BUSINESS PLAN CEN/TC 72 FIRE DETECTION AND FIRE ALARM SYSTEMS EXECUTIVE SUMMARY

General Principles of Smoke Control

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

Development of a European approach to assess the fire performance of facades

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Update on European Standardization Work

This document is a preview generated by EVS

BUSINESS PLAN CEN/TC 197 PUMPS EXECUTIVE SUMMARY

The national standards bodies of:

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

This document is a preview generated by EVS

Sprinklers in Europe known problems and misconceptions. Alan Brinson

European Sprinkler Campaigns. Edinburgh, 20 January 2010 Alan Brinson

Impact of quick incident detection on safety in terms of ventilation response

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

Fire Protection and Safety in Tunnels Conference Opening Remarks. Dr Fathi Tarada Secretary, PIARC Tunnel Operations Committee

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels

Mobile ventilation units in tunnels

This document is a preview generated by EVS

SOLIT PROJECT: WATER MIST FIRE SUPPRESSION SYSTEMS AS PART OF THE TUNNEL SAFETY SYSTEM

BUILDING INDUSTRY TUNNEL RAIL TUNNEL FIRE FIGHTING WITH HIGH PRESSURE WATER MIST

Forum for European Electrical Domestic Safety FEEDS. Residential Electrical Safety How to ensure progress?

Sprinklers Modeling for Tunnel Road Fire Fighting

RETOS Y TENDENCIAS DESARROLLO DE INFRAESTRUCTURA EN AUSTRIA. Leonardo Rosas Sánchez Bogotá Agosto 9 de 2018

This document is a preview generated by EVS

Eurocode 9 Design of aluminium structures

CEN/TC 442 Decisions taken /16

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

NOVENCO CAR PARK THRUST VENTILATION SYSTEM DESCRIPTION. Pure competence in air.

ISO INTERNATIONAL STANDARD. Steel cord conveyor belts Part 4: Vulcanized belt joints

ISO INTERNATIONAL STANDARD. Rotary positive displacement pumps Technical requirements

English version. Management Centre: Avenue Marnix 17, B Brussels

International Standards and their relevance to the Modern Built Environment

This document is a preview generated by EVS

Emergency Ventilation System Design - Preliminary Report Shishir Gupta

This document is a preview generated by EVS

Seminar on Standardisation in Research and Innovation Practical tools for the dissemination and implementation of research results

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66

List of EGOLF technical experts (assessors) in fire testing

TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS

ISO INTERNATIONAL STANDARD

This document is a preview generated by EVS

This document is a preview generated by EVS

WG 1: Fire Engineering V. Strategy and guidelines for damage prevention Fire design in Europe

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

Considerations in the Design of Smoke Management Systems for Atriums

CEN/TC 442. Building Information Modelling REPORT TO ACE BRUSSELS ØIVIND ROOTH, CHAIR CEN/TC442

Performance Based Fire Protection With Water Mist

BUSINESS PLAN CEN/TC 125 MASONRY EXECUTIVE SUMMARY

ISO INTERNATIONAL STANDARD. Welding Acceptance inspection of electron beam welding machines Part 4: Measurement of welding speed

High flying fire protection HI-FOG for aircraft hangars

BUSINESS PLAN CEN/TC 145 PLASTICS AND RUBBER MACHINES EXECUTIVE SUMMARY

Sýnishorn Fire resistance test for service installations - Part 1: Ventilation ducts

Case Study 1 Underground Car Park

JOINT VENTURE WITH HANIEL Delivering Shareholder Value. 16 December 2016

This document is a preview generated by EVS

This document is a preview generated by EVS

Fire resistance design in Europe

Practical problems of applying performance-based structural fire engineering in building design

ISO INTERNATIONAL STANDARD

designed for rail 5000 Series

Fire classification of construction products and building elements

Construction Products Regulation (CPR) and BS 6701

Fire Resistance - Implications for regulations and standards of the September 11th terrorist attacks on the world trade centre Tom Lennon, FRS, BRE

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Plastics piping systems for hot and cold water installations Crosslinked polyethylene (PE-X) Part 1: General

EUROPEAN BUREAU. EuroTAP European Tunnel Assessment Programme

ISO INTERNATIONAL STANDARD. Packaging Tactile warnings of danger Requirements. Emballages Indications tactiles de danger Exigences

Sýnishorn Health care services - Quality management systems - Requirements based on EN ISO 9001:2015

This document is a preview generated by EVS

Extended Coverage Sidewall Sprinklers

English Version. Office furniture - Office work chair - Part 4: Clarifications to EN :2000 (Dimensions)

This document is a preview generated by EVS

and Sprinkler System in Resalat Tunnel of Tehran

This document is a preview generated by EVS

This document is a preview generated by EVS

Overview of the PRISME project Technical Description and Main Outcomes

Welcome to Holophane

This document is a preview generated by EVS

Crossrail. Clare Hebden; September 2012

Sýnishorn Ventilation in hospitals - Coherent hierarchic structure and common terms and definitions for a standard related to ventilation in hospitals

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD

Smoke and heat control systems Part 3: Specification for powered smoke and heat exhaust ventilators

English Version. Daylight of buildings

EIB FINANCING FOR SUPPORTING GORENJE GROUP R&D STRATEGY Mr. Štefan Kuhar, Executive director for Finance in Gorenje Group January 2017

ISO 1806 INTERNATIONAL STANDARD. Fishing nets Determination of mesh breaking force of netting

This document is a preview generated by EVS

This document is a preview generated by EVS

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

A Priori Modelling of Fire Test One

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Flex resistance

This document is a preview generated by EVS

Case Study 2 Production and Storage. SFPE Polish Chapter Wojciech Węgrzyński, Grzegorz Krajewski Building Research Institute (ITB)

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

This document is a preview generated by EVS

CEN/TC 186 ISO/TC 244

Transcription:

Smoke control in car parks The actual situation in CEN TC 191 SC1 WG9 Imagine the result Jean-Claude DE SMEDT MIFireE,MSFPE,MNFPA Senior Fire Safety Engineering Consultant @ ARCADIS Belgium Convener of CEN TC191 SC1 WG9 Smoke Control in Car Parks

About ARCADIS

What we do Consultancy, design, engineering and management services In infrastructure, water, environment and buildings For companies and governments

Our mission We want to be the leader in Flanders, Brussels and Wallonia for complex projects in our fields of activity

A solid partner with healthy growth Top 3 in Belgium for consultancy and engineering Annual revenues in millions! People (FTE)

Strong local presence Antwerp Berchem Ghent Hasselt Leuven Brussels Charleroi Luik

A worldwide network based on strong local positions 15.000 people strong and! 2 billion in annual revenues A worldwide netwerk for consistent quality to multinational clients in Europe, North and South America Top 3 in Europe and top 10 worldwide Quoted on Euronext

Smoke control in car parks The actual situation in CEN TC 191 SC1 WG9

Both systems will be covered by the European standard ducted systems as well as jet fan systems

Scope This standard gives minimum design, installation and commissioning requirements for powered smoke and heat control systems for enclosed car parks, with or without sprinkler protection, on one or more levels, for cars and light commercial vehicles (max 3,5 T), to reach the design objectives outlined in this standard. This standard is applicable for cars powered by petrol or diesel or other fuels which will have a fire performance similar to vehicles powered by petrol or diesel. This standard only covers traditional means of single vehicle parking, that is, those car parks with cars parked alongside each other with common access roadways/lanes for cars to be driven in and out.

Scope It does not cover other forms of car parking systems, such as stacking systems. Smoke and heat control systems for lorry parks and coach parks are not covered by this standard. This standard covers systems intended 1. to provide smoke clearance after a fire (system 1), 2. to assist active fire!fighting operations (system 2), 3. to protect the means for occupants to escape from the car park (system 3) Controls of and power supplies to the smoke control system are included. This standard does not cover requirements for normal day!to!day ventilation

CEN TC191 SC1 WG9 So far we had 10 meetings in EUROPE and 2 more meetings planned in 2011 (Antwerp & Paris) The activities started in December 2008 Participating countries: Austria, Belgium, France, Finland, Germany, Italy, Poland, Spain, The Netherlands, Luxemburg and UK At this moment we have about 125 documents into our portfolio A TG1 has been created within CEN TC191 SC1 WG9 Will deal with the parts of the standard dealing with CFD Chaired by Grzegorz SZTARBALA from Poland

A first draft based on the Belgian Standard & British standards had been prepared and discussed After discussion and analysis of this draft text we came to the conclusion that these two standards where mainly based on inspired guesswork and that it was not possible to adopt a calculation method as such Also some problems occur when we started to discuss the Fire Sizes for cars

To proceed with the discussions and make a final choice regarding Fire sizes we have invited Daniel JOYEUX from EFECTIS France who had been involved into a major research program in 1999 at CTICM and Martin SHIPP from BRE - FRS who recently lead the recent research in UK CTICM HRR BRE TESTS

Further to these both presentations it was agreed to use following values for HRR: Single burning car = 4 MW (Sprinklered fire) Two cars burning = 8 MW Three cars burning = 10 MW A 3 option approach has been suggested: Steady state Standard 3 car time dependent curve Special time dependent curved based on 1st and subsequent curves from CTICM

In order to proceed with the calculation procedure it has been agreed to adopt the method published in 1999 Extending the principles of Impulse Ventilation in Tunnels to apply to Smoke Control in Car Parks By H. P. Morgan B Sc, PhD, C Phys, M Inst P, C Eng, F I Fire E B. Vanhove, ir-arch J-C. DeSmedt, MIFireE,MNFPA,MSFPE

This calculation method allows to calculate the horizontal spread of the ceiling jet under the ceiling and takes into account the type of ceiling present in the car park. The velocity of the ceiling jet will vary if there is a flat ceiling,a ceiling with transversal beams or longitudinal beams

Situation with longitudinal beams Situation with a flat ceiling Situation with transversal beams

We are very hopeful that in addition to the results of the CTICM research and FRS/ BRE research we also will be able to utilize the results of a large research program which takes place in Gent at Ugent which will certainly validate everything we have so far!

Fire IVRY/ SEINE (level -3) This fire started in Paris on 31/10/2009 in an underground car park under a residential building was announced in the press as been a fire where 200 cars where destroyed Each level had an area of 3600 m" and was separated in two area s of about 1.800 m" separated by a fire door All the levels had separated boxes where the owners could park their cars This building was situated in an area where a lot of vandalism takes place and therefore most of the people did not want to park their car in the garages anymore

Fire IVRY/ SEINE (level -3) Most of the garage boxes have been used as a storage room(see photo s) with a high fire risk potential The investigation suspect that this fire is a criminal fire as they found two ignition sources They have fires in this building very regularly This fire lasted 5 hours The fire started at level -3 and spreaded towards levels -2 & -1 through the dilatation joints and probably also through conduction in several garages baring in mind the high potential risk

Fire IVRY/ SEINE (level -3) The Paris Fire Brigade have extinguished the fire by injecting foam through the ventilation ducts 37 cars have been destroyed by this fire (and not 200!!) as stated in the press

No comments needed#

No comments needed#

No comments needed#

Fire Safety & Smoke Control in a Multifunctional project including a very large car park in Hasselt, Belgium

Design criteria Smoke control: following BR186 & BR368 including NBN EN 12 101-5 for the shopping Center Car Parks: following the Belgian standard NBN S21 208-2 & calculation of the ceiling jet velocity Large stores: following the Belgian standard NBN S21 208-1 & NBN EN 12 101-5 Sprinkler system: following CEA 4001 Smoke Detection: following EN54-14

Fire Safety Level Kade

No downstand 1400 700 1 4500 5900 Smoke Free Height 3000

Shops Promenade SHEVS duct SHEVS fans SHEVS Shaft 3.00 m Evacuation level Promenade Shops Kade Motorised dampers SHEVS duct Evacuation shaft Shops Kade Parking -1 Parking -2

Sprinklers Sidewall sprinklers SHEVS duct 4.60m 6.10 m

Sprinklers Sidewall sprinklers SHEVS duct 4.60m Smoke Free Height 3.00 m Min. 3.50m 6.10 m

Sprinklers Sidewall sprinklers SHEVS duct 4.60m Smoke Free Height 3.00 m Min. 3.50m 6.10 m

First approach for SHEVS

SHEVS principle level -1

Sprinklers Jet fans

Sprinklers Impulse fans Private parking Public parking

schacht 4 schacht 2 schacht 3 67 m utobrand inductieventilatoren schacht 1 dwarsbalken In/uitrit inductieventilatoren stuwkrachtventilatoren 283 m HRR-curve

Air velocity vectors without fire Air velocity vectors with fire

Visibility

Temperature at 1.7m & 2.6m

SHEVS for level -2

SHEVS for level -3

IMAGINE THE RESULT

THANK YOU