T8112 Programmable Thermostat

Similar documents
T8132C Programmable Thermostats

T8112C,DElectronic ProgrammableThermostats

T8011R Programmable Heat Pump Thermostat

CT2800 Programmable Thermostat

MagicStat CT3300 Programmable Thermostat

T8602C Chronotherm IV Deluxe Programmable Thermostats

T8112C,D Electronic Programmable Thermostats

Honeywell/20 Programmable Thermostat

T8600D Chronotherm IV Deluxe Programmable Thermostats

Deluxe Programmable Thermostats

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

T8611M Deluxe Programmable Heat Pump Thermostats

Honeywell CT3550 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

T8131C Programmable Thermostat OWNER S GUIDE

Deluxe Programmable Heat Pump Thermostat T8611M

CT2700 An Electronic Round Programmable Thermostat

T8034C Heating/Cooling Thermostats

Programmable Load Management Thermostat

Programmable Thermostat by Duracraft

T4098A,B Deluxe Electric Heat Thermostats

T4398A,B High Performance Electric Heat Thermostats

T8700B,C An Electronic Round Programmable Thermostat

T6984F,G Electronic Floating Control Thermostats

T8400C and T8401C Electronic Thermostats

Honeywell/36. Programmable Thermostat OWNER S GUIDE

T8401C Electronic Thermostats

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

T7200D,E Series 2000 Commercial Microelectronic Thermostats

CT500 Electronic Thermostat

T8524 Deluxe Electronic Thermostat

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

T8411R Electronic Heat Pump Thermostat

Honeywell CT8602 PROGRAMMABLE THERMOSTAT

T8400C Electronic Thermostat

C554A Cadmium Sulfide Flame Detector

T6984 A,D,E Electronic Floating Control Thermostats

ACONT600AF11MA Programmable Comfort Control

The T6140A,B Remote Bulb Temperature Controller

TCONT800AS11AA Touch Screen Programmable Comfort Control

T834C Heating-Cooling Thermostat

T7984 A,B,C Electronic Modulating Control Thermostats

ACONT800AS11AA Touch Screen Programmable Comfort Control

T8000C Programmable Thermostat

TCONT602AF22MA. Programmable Comfort Control. Installation Instructions 18-HD37D1-1

TCONT800AS11AA Touch Screen Programmable Comfort Control

T7100D Microelectronic Conventional Thermostat

T8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE

T874 Multistage Thermostat and Q674 Subbase

F150E Media Air Cleaner

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

Programmable Load Controller USER S GUIDE

ASYSTAT625A Humidity Control

tcu.z Commercial Programmable Thermostat Installation Instructions

C6097A,B Pressure Switches

Operator: Save these instructions for future use!

T7079A,B Solid State Remote Temperature Controllers

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

F25F Media Air Cleaner

H1008A,D Automatic Humidity Controls

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

T8400C Universal Electronic Thermostats

TH8320U and TH8321U Touch Screen Programmable Thermostats

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

heat (2 heat/1 cool).

Honeywell CT3611 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

RA889A Switching Relay

Operator: Save these instructions for future use!

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

M6063A Compact Rotary Mixing Valve Actuator

F200E Charged-Media Air Cleaner

EWT-3102/EWT-3103 Touchscreen Programmable Thermostat

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

VisionPRO 8000 with Wi-Fi

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

Q7300L Series 2000 Commercial Thermostat Subbases

CT1001/CT1002 Touchscreen Programmable Thermostat

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats

Smart Temp. Model

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Microelectronic Programmable Thermostat Owner s Manual. 1 J.H Form Number

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

This thermostat provides electronic control of 24 VAC single-stage and multi-stage

OWNER'S MANUAL. How to operate your new Programmable Thermostat

5+2 Day. up to HEAT COOL

Commercial Touchscreen Thermostat

Home and Building Control Home and Building Control Helping You Control Your World

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Operator: Save these instructions for future use!

Commercial/Industrial Combustion Control Level Three Announcement

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

Safety & Installation Instructions

OPERATING & MAINTENANCE MANUAL HORIZONTAL WATER SOURCE HEAT PUMP. World class comfort.

Product Instructions. Viega Programmable Heat/Cool Thermostat. Technical data

Must be installed by a trained, experienced technician

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

CR7075 Two-Stage Lighting Controller

Transcription:

T8112 Programmable Thermostat FEATUES PODUCT DATA HEAT-OFF-COOL system switch. AUTO-ON fan switch. Separate programs for weekdays and weekends (5 day/2 day). Digital LCD display. Easy to program and install. Precise temperature control. GENEAL The T8112 Programmable Thermostat provides energy savings for single-stage heating and cooling applications while providing reliable, precise temperature control. Four daily energy saving programs. Compatible with most 24 Vac standing pilot, gas electronic ignition, oil or central electric systems. equires two AA alkaline batteries. LCD flashes bat Lo indicating low battery power. Isolated heating/cooling circuits. Contents General... 1 Features... 1 Specifications... 2 Ordering Information... 2 Installation... 3 Programming the Thermostat... 6 Checkout and Settings... 7 Troubleshooting... 8 U.S. egistered Trademark Copyright 1996 Honeywell Inc. All ights eserved 68-0170

SPECIFICATIONS IMPOTANT The specifications given in this publication do not include normal manufacturing tolerances; therefore, an individual unit might not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. Model: T8112 Thermostat: Provides electronic programmable control for 24 to 30 Vac heating and cooling systems. Programming Keys: Eight program keys; without keyboard door. Electrical ating: Battery operated (2 AA alkaline batteries). System and Fan atings: 1.2A run; 7.5A inrush. Total cooling and fan load not to exceed 1.2A. Dimensions: See Fig. 1. Mounting: Mounts on mounting plate directly on wall. Mounting screws and wall anchors provided. Setpoint ange: 45 F to 88 F (7 C to 31 C). Operating Ambient Temperature ange: 40 F to 110 F (4 C to 43 C). Shipping Temperature ange: -20 F to 120 F (-29 C to -49 C). Temperature Display: Fixed or field selectable. Operating elative Humidity: 5 to 90 percent H; noncondensing. Time Indication: 12 hour with AM, PM indication. 6-7/8 (175) 1(25) 3/4 (19) 4 (102) 1-1/4 (32) M9349 Fig. 1. T8112 dimensions in in. (mm). ODEING INFOMATION When purchasing replacement and modernization products from your TADELINE wholesaler or your distributor, refer to the TADELINE Catalog or price sheets for complete ordering information, or specify: 1. Model Number. 2. Accessories, as desired. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Home and Building Control Sales Office (check white pages of phone directory). 2. Home and Building Control Customer Logistics Honeywell Inc., 1985 Douglas Drive North Minneapolis, Minnesota 55422-4386 (612) 951-1000. In Canada Honeywell Controls Limited, 155 Gordon Baker oad, North York, Ontario M2H 2C9. International Sales and Service offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 68-0170 2

Cycles Per Hour Adjustment: Heating: Field adjustable to 3, 6, or 9 cph ±10 percent. Cooling: Factory set at 3 cph ±10 percent (not field adjustable). Calibration: Thermostat and thermometer self-calibrating to ±1.25 F. Accessories: 205013 Isolation elay Kit. 205014 Transformer Plug-in Kit. 205015 International Organization for Standardization elay and Transformer. INSTALLATION When Installing this Product 1. ead these instructions carefully. Failure to follow the instructions can damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product and in the compatibility chart (Table 1) to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. Compatibility Check Table 1 to make sure the thermostat is compatible with the intended system. Table 1. Compatibility Chart. Compatible System Type with T8112 Gas Standing Pilot Gas Electronic Ignition Gas-Fired Boilers a Gas Millivolt No Oil-Fired Boilers a Oil-Fired Furnace Electric Furnace Electric Air Conditioning Baseboard Electric (120/240 Line Volt) No Heat pumps/multistage Equipment No a Compatible with 2-wire Honeywell zone valves. All system types: Not compatible with any 120/240 volt circuit. Not designed for steam or gravity systems. Not compatible with 2-wire White odgers no. 1361 Valves. Isolating relay required for 3-wire thermostats for zone valves. WANING ELECTOCUTION HAZAD CAN CAUSE POPETY DAMAGE, SEVEE INJUY, O DEATH. Disconnect power supply before wiring to prevent electrical shock or equipment damage. Location Locate the thermostat about 5 ft (1.5m) above the floor in an area with good air circulation at average temperature. Do not mount the thermostat where it can be affected by: drafts or dead spots behind doors and in corners. hot or cold air ducts. concealed pipes and chimneys. unheated (uncooled) areas such as an outside wall behind the thermostat. Mounting Plate Installation (Fig. 2) Hold mounting plate in position and mark the two holes for mounting. Level for appearance only; thermostat functions properly even when not level. Tighten the mounting screws. Set aside the mounting plate. Drill the two holes in the wall as marked. Drill 3/16 in. holes for drywall. Drill 7/32 in. holes for plaster or wood. eposition the mounting plate over the holes and pull wires through the wiring opening. Loosely insert the two mounting screws into the holes. WALL WALL ANCHOS (2) WIES THOUGH WALL OPENING MOUNTING SCEWS (2) MOUNTING PLATE M1718 Fig. 2. Mounting plate installation. Wiring Thermostat All wiring must comply with local electrical codes and ordinances. efer to Fig. 5 through 8 for typical hookups. A letter code is located near each terminal for identification. 3 68-0170

CAUTION Disconnect power before wiring to prevent electrical shock or equipment damage. Connect the system wires to the thermostat. See Fig. 3. A letter code is located near each terminal for identification. Hold the thermostat as shown in Fig. 4 to minimize the need for wire extenders. Securely tighten each terminal screw. Push excess wire back into the hole. Plug the hole with nonflammable insulation to prevent drafts from affecting thermostat operation. un the required number of wires to the thermostat location. efer to Fig. 5 through 8 for typical wiring diagrams. In 5-wire installations only, be sure to remove the factoryinstalled jumper connecting the terminals and. 1 2-WIE HEAT-ONLY (JUMPE INTACT) HEATING ELAY O VALVE COIL A B C D POWE SUPPLY. POVIDE DISCONNECT MEANS AND OVELOAD POTECTION AS EQUIED. 1 JUMPE M1709B Fig. 5. 2-wire heat-only application (jumper intact). 5/16 in. (8 mm) STIP INSET STAIGHT UNDE SCEW HEAD c JUMPE (FACTOY- INSTALLED) EMOVE IF 5-WIE SYSTEM 3-WIE COOL-ONLY (JUMPE INTACT) A C B D JUMPE END OF WIE VISIBLE HEE M1712A Fig. 3. Proper wiring technique. COOLING CONTACTO COIL FAN ELAY 1 POWE SUPPLY. POVIDE DISCONNECT MEANS AND OVELOAD POTECTION AS EQUIED. M848A Fig. 6. 3-wire cool-only application (jumper intact). Fig. 4. Holding thermostat while installing. M3002A 68-0170 4

4-WIE HEAT/COOL (JUMPE INTACT) HEATING ELAY O VALVE COIL A B COOLING CONTACTO COIL C D FAN ELAY JUMPE 1 POWE SUPPLY. POVIDE DISCONNECT MEANS AND OVELOAD POTECTION AS EQUIED. M1710B Fig. 7. 4-wire heat/cool application (jumper intact). 5-WIE HEAT/COOL (JUMPE EMOVED) THEMOSTAT BACK FO HIGH EFFICIENCY FUNACE (90%+ AFUE) ADJUST: SCEW A OUT 1 TUN SCEW B IN FUEL SWITCH F POSITION A B FUEL SWITCH F E C D ADJUST SCEWS THOUGH HOLES TO SELECT OPEATION DESIED HEATING SYSTEM FUEL SWITCH POSITION WAM AI A IN FUNACE HOT WATE BOILE ELECTIC A IN FUNACE B IN A OUT 1 TUN B IN Fig. 9. Back view of thermostat. B OUT 1 TUN M3669 Adjust System On-Time as equired The thermostat on-time is factory set for a warm air, gas or oil heating system. If you are installing it on another type of system, the system on-time must be adjusted by changing the setting of screws A and B on the back of the thermostat. Use the heating system table in Fig. 9 as a guide to minimize room temperature swings. The system on-time should be optimized according to the type of system. Setting the screw out one turn means turning the screw approximately 360, or one complete turn. F F E A B C D This thermostat does not have a setting for steam/ gravity air. Cycles would not be long enough for accurate temperature control. For condensing furnaces, follow manufacturer instructions. HEATING ELAY O VALVE COIL FAN ELAY IMPOTANT When using a high efficiency furnace such as a 90 percent or greater AFUE (Average Fuel Utilization Efficiency) unit, adjust screw A out one turn and screw B In one turn. COOLING CONTACTO 1 COIL 1 1 POWE SUPPLY. POVIDE DISCONNECT MEANS AND OVELOAD POTECTION AS EQUIED. M1711B Fig. 8. 5-wire heat/cool application (jumper removed). Adjust Fan Operation Switch, as equired The thermostat fan operation switch, labeled FUEL SWITCH (see Fig. 9) is factory set in the F position. This is the correct setting for most systems. If you have an electric heat system, set the switch to E. In systems with the G terminal connected, the E setting turns on the fan immediately with heating or cooling. If you want a longer on-time, readjust screws A and B as follows (refer to Table 1 Compatibility Chart): Warm Air Furnace set at the Hot Water setting (A out one turn, B in). Electric Furnace leave at the Warm Air Furnace setting (A in, B in). This thermostat does not have a setting for steam/ gravity air. Cycles would not be long enough for accurate temperature control. Install Batteries IMPOTANT Batteries must be installed for programming and operating the thermostat and heating/cooling system. 5 68-0170

TU LEAVE T8112 POGAMMABLE THEMOSTAT Use two AA alkaline batteries; nonalkaline batteries will not last as long. Make sure the thermostat is set to the Off position. Use a coin to remove the battery door (see Fig. 10). Install the new batteries as shown, making sure positive and negative terminals are oriented correctly (see Fig. 11). eplace the battery door. When the batteries are running low, a bat Lo indicator will flash for one to two months before batteries run out completely. eplace the batteries as soon as possible after the indicator starts flashing. If the batteries are not replaced when the bat Lo indicator is flashing, the indicator eventually stops flashing. When the batteries are almost completely dead, bat Lo will stay on without flashing, indicating that the thermostat and heating/cooling system have stopped working. The thermostat will not function after the batteries are completely dead, and the bat Lo indicator disappears, leaving a completely blank display. To remove the batteries, press down on the left ends. When the new batteries are installed within 20 to 30 seconds of removing the old ones, the thermostat does not have to be reprogrammed. If the display is blank, the batteries are dead or incorrectly installed and the thermostat has to be reprogrammed. See Owner s Manual for reprogramming instructions. IMPOTANT Although the thermostat has a low battery indicator, replace the batteries once a year to prevent the thermostat from losing time and programming due to lack of battery power. M5781 Fig. 10. emoving battery door. FAN SWITCH Fan INSTALL TWO AA ALKALINE BATTEIES AS SHOWN Auto On TU LEAVE AM System Cool Off Heat Fig. 11. Installing batteries. SYSTEM SWITCH M5782 Mounting Thermostat Engage the tabs at the top of the thermostat and mounting plate. See Fig. 12. Press the lower edge of the case to latch. To remove the thermostat from the wall, first pull out the bottom of the thermostat and then remove the top portion. A. ENGAGE TABS AT TOP OF THEMOSTAT AND MOUNTING PLATE. B. PESS LOWE EDGE OF CASE TO LATCH. AM M5780 Fig. 12. Mounting thermostat on mounting plate. POGAMMING THE THEMOSTAT Set the Current Time/Day To set the time: Press and release the Clock/Day key once. Press the Time keys or until the current time displays. To set the day: Press and release the Clock/Day key again. Press the Time keys or until the current day displays. Press the un Program key. Heating Program To set the system switch to HEAT: Press and release the Schedule key once. WAKE, Mon-Fri, and SET appear on the display. Press the Time keys or to program WAKE time, and Temp keys or to program WAKE temperature for Mon-Fri. epeat this sequence for LEAVE, ETUN, and SLEEP. Press the Schedule key until SAT, SUN, WAKE and SET appear on the display. Press the Time keys or to program WAKE time, and Temp or to program WAKE temperature for Sat-Sun. epeat this sequence for SLEEP. Cooling Program Set the system switch to COOL and follow the same procedure as for the Heating Program. 68-0170 6

After programming, adjust the fan and system switches as desired. Press and release the un Program key to start the program. A Quick Guide for Operating or Making Changes The system switch must be set to Heat or Cool to perform the following. To temporarily change the temperature for the current period only: Press the Temp keys or. The temporary indicator shows on the display and cancels itself at the next scheduled change. To cancel sooner, press the un Program key. To hold a temperature indefinitely: Press the Hold Temp key. Press the Temp keys or. To cancel, press the un Program key. To check the current temperature setting: Press the un Program key. (When using TEMPOAILY CHANGE or HOLD, pressing this key will cancel the change or hold.) To check the programs: Press the Schedule key repeatedly to see each time and temperature. Press the un Program key. To cancel a program: Press the Schedule key until the program to cancel appears Press both the Time keys and together. To permanently change a program: epeat the steps in the Heating Program or Cooling Program section as applicable. To return to the normal program: Press the un Program key. CHECKOUT AND SETTINGS After the thermostat is mounted on the mounting plate, check operation as follows: Heating Do not check the heating system operation by jumpering the thermostat terminals at the primary control such as the gas valve, zone valve, or oil burner control. This will damage the thermostat. Instead, you could jumper and wires at the thermostat. Move the system switch to HEAT and the fan switch to AUTO. Press the TEMP key until the setting is about 10 F (6 C) above the room temperature. After a short delay, the heating should start and the fan should run (immediately if fan operation switch is set in E position). Press the TEMP key until the setting is about 10 F (6 C) below the room temperature. The heating equipment should shut off. Cool Off Heat Auto On Temp Temp M1705 M1703 Cooling To avoid possible compressor damage, do not operate the cooling system when the outside temperature is below 50 F (10 C). See the compressor manufacturer instructions for further information. When the cooling setting is changed, the thermostat can delay up to five minutes before turning on the air conditioner to protect the compressor. Move the system switch to COOL and the fan switch to AUTO. Press the TEMP key until the setting is about 10 F (6 C) below room temperature. The cooling equipment and fan should start. Press the TEMP key until the setting is about 10 F (6 C) above the room temperature. The cooling equipment and fan should stop. Cool Off Heat Auto On Temp Temp M1705 M1704 Move the system switch to OFF with the fan switch remaining at AUTO. The system and fan should be off. Cool Off Heat M1707 Auto On M1705 7 68-0170

Fan Switch FAN AUTO: Normal setting for most homes. A single-speed fan turns on automatically with the air conditioner or furnace. A two-speed fan usually runs on high with the air conditioner and on low with the furnace. FAN ON: The fan runs continuously. Use for improved air circulation during special occasions or for more efficient electronic air cleaning. Auto Auto On M1705 On M1706 System Switch COOL: The thermostat controls the air conditioning system. OFF: Both the heating and air conditioning systems are off. HEAT: The thermostat controls the heating system. Cool Cool Cool Off Off Off Heat M1704 Heat M1707 Heat M1703 TOUBLESHOOTING IF Display will not come on. Temperature display will not go lower than 45 F (7 C) or higher than 88 F (31 C) during programming. Heating will not come on. Cooling will not come on. SYSTEM ON indicator is lit, but no heat is coming from the registers. Furnace or air conditioner cycles too frequently. The system on-time is too short or too long. The thermostat current setting does not match the display temperature. bat Lo remains on the display after fresh batteries have been installed. THEN Set the system switch to OFF; remove batteries; insert backward for at least five seconds to reset thermostat; replace batteries correctly. Display should come on. Make sure batteries are fresh and installed correctly. The temperature setting limit has been reached. The setting range is 45 F to 88 F (7 C to 31 C). If the display is blank or displays bat Lo, install fresh batteries. Check that the switch on the thermostat is set to HEAT. Check the system fuse or circuit breaker and replace or reset if necessary. If the temperature setting is higher than the current temperature, and SYSTEM ON indicator is lit, see the furnace manufacturer instructions. If the display is blank or displays bat Lo, install fresh batteries. In 2- or 4-wire installations, verify that the - jumper is installed. Check that the switch on the thermostat is set to COOL. Check the system fuse or circuit breaker and replace or reset if necessary. The thermostat has a built-in time delay on cooling. Allow five to ten minutes after changing the setting before the air conditioner starts. If the temperature setting is lower than the current temperature, and the SYSTEM ON indicator is lit, move the system switch from COOL to OFF for ten minutes. After ten minutes, return the switch to the COOL position. If the air conditioner comes on, the compressor could have reached its high limit temperature protection and shut down. If the air conditioner does not come on after ten minutes and the SYSTEM ON indicator is lit, see the air conditioner manufacturer instructions. Allow time for the furnace to heat up and the fan to come on before checking for heat at the register. Check to make sure system on-time is set correctly according to the instructions in the Installation section. Check the system setting on the back of thermostat. eadjust according to the instructions in the Installation Section. Check that the wiring hole in the wall behind the wallplate was plugged with insulation to prevent drafts that could adversely affect thermostat operation. It is normal for the current setting and display temperature to differ occasionally. emove batteries. Wait one hour. Install fresh alkaline batteries. Home and Building Control Honeywell Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker oad North York, Ontario M2H 2C9 Helping You Control Your World 68-0170 1-96 Printed in U.S.A. 8 Printed on recycled paper containing at least 10% post-consumer paper fibers.