DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Similar documents
DUAL MONITORED INPUT/OUTPUT UNIT BN-305

SINGLE MONITORED INPUT UNIT BN-303

Instructions AutroFlame IR Flame Detector BG-201/BG-21

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Easy Reliable Flexible. Interactive fire detection system

ADAPTER FOR VENTILATION DUCT BWP-143A-SS (STAINLESS STEEL)

Operating Instructions. For. Alarm Control Module. Model SSR 500

FEC400 Series. Installation Manual

Interface and EOL Modules 8

Input/Output Modules Data Sheet

ECO N DATE DESCRIPTION OF CHANGE CHG

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Motorised Infrared Optical Beam Smoke Detector. User Guide

AutroSafe interactive fire detection system AUTROSAFE. An interactive fire detection system for complex installations

AUTROSAFE. An interactive fire detection system for larger vessels

System Description Autroprime Interactive Fire Detection System

M2500 Engine Controller Installation Manual

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

AUTROSAFE 4 A new level in interactive fire detection systems

Excel-EN Conventional Fire Control Panel

Interface Modules for SENTRI

Motorised Infrared Optical Beam Smoke Detector. User Guide

Installation, Operating and Maintenance Manual

Heat Sensor Cable Alarm Units DT650L / DT950L

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

Intelligent addressable fire alarm control panel

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

System 800 Addressable Fire Detection & Alarm System

MODEL 5100 VOTING LOGIC MODULE

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

MD12-1 Vehicle Loop Detector

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

INPUT / OUTPUT MINI MODULES

LD1000 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

1.7. Insulation fault evaluators EDS460/490 EDS461/491

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

MD12-2 Vehicle Loop Detector

Power Supply Display Module PSDM. Installation and Operation Manual

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

End To End Optical Beam Smoke Detector. Additional Information

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

Conventional Fire Alarm System 2014 V1.2

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

02/11/2015

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

Process & TeMPerATUre UniversAl input DigiTAl MeTers

FX FIRE DETECTION SYSTEM

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

FIRERAY 5000 range USER GUIDE

Addressable Loop Modules

Annunciator Unit SACO 16 D1. Product Guide

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Vega Devices.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

QA16 Addressable System

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Carbon Monoxide Transmitter

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

AutroFlame X33AF. Addendum. Multi-spectrum IR flame detector. Protecting life, environment and property...

DS7465i. Installation Instructions. Input/Output Module

Door Release Power Supply

AL600ULADA. NAC Power Extender. Installation Guide

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OPERATION AND INSTALLATION MANUAL

Technical Manual. Level Alarm Unit CARLA & WIDS

EXTINGUISHING AGENT RELEASE MODULE

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Application, Installation, Operation & Maintenance Manual

Touch Screen 1 loop Addressable Fire Alarm Panel

Reflective Optical Beam Smoke Detector User Guide

AO Annunciator Module

MINERVA MX. 800 Series Ancillary Equipment

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

An introduction to... Sigma

HART XL High Sensitivity Smoke Detection

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

FireNET Plus Wiring Instructions

LDRA6 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

Loop units. a wide range covering your basic fire detection needs

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

Snifter. User Manual. Distributor

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

FX NET FIRE DETECTION SYSTEM Installation and commissioning manual

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

On the job around the clock 24/7: Fire detection systems

Added password for IP setup page : Password must be in IP format!

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Transcription:

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection systems Multifunction unit: Function selected by switch setting Input / Output signals 2 non-isolated inputs: on /off function with end-ofline monitoring 2 outputs: Potential free contact without end-of-line monitoring 1A 30 VDC dry relay contact for the output ports Includes the SelfVerify function for reduced maintenance/testing and increased reliability on the input for critical alarm functions Short-circuit isolator in each unit Automatic addressing Proven technology DIN-rail mounted Designed to meet the requirement of the major maritime classification societies Approved according to EN-54-17, EN 54-18 Description / Application The Dual Monitored Input / Output Unit BN-305-2 has been designed for use with Autronica s interactive fire detection systems, Autroprime and AutroSafe, and includes the SelfVerify function. This function ensures the highest grade of reliability and reduces the need for manual testing because the panel is able to continuously and automatically check all units that include this function. Note: External devices attached to this interface unit require a separate power source (they cannot be powered by the detection loop). SelfVerify: The unit s ability to initiate alarm is regularly checked. Function/Connection Options and Switch Settings The internal DIP switch S1 (see drawing on page 3) selects the function performed by the BN-305-2 unit. For detailed description of connection options, see page 5. For detailed description of function options see page 7. 116-P-BN305-2/CGB, Rev. A, 2016-02-17 Protecting life, environment and property

Product Name Part number Description BN-305-2 116-BN-305-2 Dual monitored input/output unit Technical specifications Dimensions (mm) Weight (g) Housing material Colour Mounting Power Current consumption 125 x 87 x 49 (complete unit) 100 x 85 x 20 (PCB w/comp. only) 122 (complete unit) 54 (PCB w/components) Polyamide PVC V0 Pale green NS32 and NS35 DIN-rail BN-305-2 shall be installed in an external enclosure which has an IP grade of at least IP22 and a total mass of more than 4.75kg. Connects to Al_Com loop only 0,1 ma Temperature range -25 to +70 C Humidity Degree of protection Communication loop protocol Cable terminals Cable requirements Al_Com Maximum input cable length Maximum cable capacitance Serial impedance ZC Max Response time Output relay rating Output relay type Threshold 10 % - 95 % RH (non-condensing) IP20 (without external enclosure) Autronica loop communication protocol (AL_Com) Max 2.5 mm² single core wires Refer to specification for AutroSafe or Autroprime 100 m 30 nf 40mΩ <= 1 second 1 A 30 VDC Dry contact, Latching type; keep state on loss of power. No EOL monitoring Short-circuit: 0-235 Ω Normal: 1200-4800 Ω Activate: 260-1000 Ω Open circuit: 5400- Ω LED Approvals 3 ms flash at 0,5 Hz Output: 10 ma current source 16-24 VDC Maximum length of connected wire: 3 m See website Autronica Fire and Security AS Tel.: +47 90 90 55 00 E-mail: info@autronicafire.no www.autronicafire.com Page 2

0470 Autronica Fire and Security AS, N-7483 Trondheim 11 0470-CPD-0031 EN 54-17:2005 Short circuit isolators EN 54-18:2005 Input/output devices Dimension Drawings 49mm 125mm 87mm Autronica Fire and Security AS Tel.: +47 90 90 55 00 E-mail: info@autronicafire.no www.autronicafire.com Page 3

Connectors and DIP switches on Circuit Board Dipswitch S1 Connectors All connections are made to screw terminals numbered 1-12. Terminal Function 1 AL_Com In (+) 2 AL_Com In (-) 3 AL_Com Out (+) 4 AL_Com Out (-) 5 Input 1 (+) 6 Input 1 (common) 7 Relay 1 contact 8 Relay 1 contact 9 Input 2 (+) 10 Input 2 (common) 11 Relay 2 contact 12 Relay 2 contact LED connectors Terminal Function J2.1 LED1 + (LED Activate) J2.2 LED1 - (LED Activate) J2.3 LED2 + (LED Fault) J2.4 LED2 - (LED Fault) LED connector: A pin header enables the option to add LED indicators. The indication is a short blink at 0,5Hz period. LED activate: The input or output is in Activation condition. LED fault: There is a fault on the input or the unit itself. Mounting BN-305-2 shall be installed in an external enclosure which has an IP grade of at least IP66 and a total mass of more than 4.75kg. Autronica Fire and Security AS Tel.: +47 90 90 55 00 E-mail: info@autronicafire.no www.autronicafire.com Page 4

Descriptions of Connection Options Input configuration A 5 N.O. 2KOhm 6 910 Ohm Input configuration B 5 N.C. 2KOhm 6 910 Ohm Input configuration C Class 3 5 N.O. 2KOhm 6 Input configuration D 5 N.C. 2KOhm 6 Figure 1 Autronica Fire and Security AS Tel.: +47 90 90 55 00 E-mail: info@autronicafire.no www.autronicafire.com Page 5

The electrical connection options for the input to the unit are shown in Figure 1. The various electrical input configurations allow a user to select under what condition the unit will be triggered to provide a signal the fire alarm system indicating the selected condition. The four different behaviours can be configured by DIP switch 5 and 6 in order to be able to monitor different setups of the input contact(s). (Switch 8 is not used). ON OFF 1 2 3 4 5 6 7 8 (See location of DIP switch S1 on the circuit board drawing) Input configuration A activates when the contacts are closed. This arrangement also allows the unit to monitor for an electrical wiring fault in the form of an open or short-circuit, between the contacts and the unit, either before or during activation. S1.5 S1.6 OFF OFF Normally Open contact with activate resistor, fault monitored for open and short-circuit. Input configuration B activates when the contacts are opened. This arrangement allows the unit to monitor for an electrical wiring fault in the form of an open or short-circuit, between the contacts and the unit, either before or during activation. S1.5 S1.6 OFF ON Normally Closed contact with activate resistor, fault monitored for open and short-circuit. Input configuration C activates when the contacts are closed. This arrangement allows the unit to monitor for an open circuit fault in the electrical wiring before activation. A short-circuit in the wiring will trigger the unit. S1.5 S1.6 ON OFF Normally Open contact without activate resistor, fault monitored for open circuit. Input configuration D activates when the contacts are opened. This arrangement allows the unit to monitor for an open circuit fault in the electrical wiring during activation. S1.5 S1.6 ON ON Normally Closed contact without activate resistor, fault monitored for open circuit. The output can be set to Normal Open or Normal Closed operation by DIP switch 1.7: DIP 1.7 OFF = Normally open DIP 1.7 ON = Normally closed DIP switch 1.8 determines the state of output if the unit loses its power. DIP 1.8 OFF = Relay remains in current state DIP 1.8 ON = Relay switches to initial state as chosen by DIP 1.7 Autronica Fire and Security AS Tel.: +47 90 90 55 00 E-mail: info@autronicafire.no www.autronicafire.com Page 6

Descriptions of Function Options The available functions include (see detailed information on the next pages): Function A Alarm condition signaling input unit with relay feedback Function B Pre Alarm condition signaling input unit with relay feedback Function C Fault condition signaling input unit with relay feedback Function D Uncommitted input unit (Output follows input) Function E Pre Alarm and Alarm condition signaling input unit with configurable input delay and relay feedback Function F Fault, Pre Alarm and Alarm condition signaling input Function G Alarm condition signaling input unit with relay output used for reset Function H Alarm condition signaling input and independent relay output function Function I Uncommitted input unit and independent relay output function Function J Relay output function (Input not in use) Function K Relay output function with activation feedback (input) Function L Relay output function with activation feedback of both positions Function M Relay output function with activation feedback and external fault input Function N Pre Alarm and Alarm condition signaling input unit with relay feedback Autronica Fire and Security AS Tel.: +47 90 90 55 00 E-mail: info@autronicafire.no www.autronicafire.com Page 7

Function A OFF OFF OFF OFF Function: Alarm condition signalling input unit with feedback function. The relay contact will follow the state of the input. Application include: Fire Alarm push buttons Flame, heat or beam detectors with relay contacts Sprinkler contacts, etc. Function B ON OFF OFF OFF Function: Pre Alarm condition signalling input unit with feedback function. The relay contact will follow the state of the input. Application include: Manual input for Pre Alarm Pre Alarm input from a detector with relay output Sprinkler contacts, etc. Function C OFF ON OFF OFF Function: Fault condition signalling input unit with feedback function. The relay contact will follow the state of the input. Application includes: Monitoring of associated equipment for faults Monitoring of detectors with relay contacts Autronica Fire and Security AS Tel.: +47 90 90 55 00 E-mail: info@autronicafire.no www.autronicafire.com Page 8

Function D ON ON OFF OFF Function: Uncommitted input. Applications: A typical application is monitoring of the power fault contact in the power supply or a fire pump. This unit can be used for: Monitoring of water level detection systems Monitoring of smoke control damper systems Monitoring of extinguishing systems Relay contact closes when input is activated. Function E OFF OFF ON OFF Function: Delayed Alarm condition signalling input unit with feedback function. Input delay 2 seconds. Configurable delays for entering Pre Alarm and Alarm condition. Default delays: Pre Alarm 10 seconds, Alarm 20 seconds. The relay contact will follow the state of the input. Application include: Sprinkler contacts, etc. Autronica Fire and Security AS Tel.: +47 90 90 55 00 E-mail: info@autronicafire.no www.autronicafire.com Page 9

Function F ON OFF ON OFF Function: Fault, Pre Alarm and Alarm condition. Applications include: Fire detectors with two-level output (Pre Alarm and Alarm). Relay contact activates for a configurable period when the unit is reset. This provides a pulse with 5 seconds interval for resetting the external detector. ALARM PRE- ALARM FAULT 910R 2K Function G OFF ON ON OFF Function: Alarm condition signalling input unit with reset function for external detector. Relay contact activates for a configurable period when the unit is reset. This provides a pulse with 5 seconds interval for resetting the external detector. Application include: Flame, heat or beam detectors with relay contacts Autronica Fire and Security AS Tel.: +47 90 90 55 00 E-mail: info@autronicafire.no www.autronicafire.com Page 10

Function H ON ON ON OFF Function: Alarm condition signalling input and independent relay output function. Number of addresses: 4 Input application includes: Fire Alarm push buttons Flame, heat or beam detectors with relay contacts Sprinkler contacts, etc. The output unit contains a potential free contact, which can be activated from a detector or a combination of several detectors or other preconfigured cause and effect relationships. No end-of-line monitoring on output function. The output can be used for: Door release Sprinkler control/functions Control of fire dampers FPE/FAD without bell patterns Function I OFF OFF OFF ON Function: Uncommitted input and independent relay output function. Number of addresses: 4 Applications: A typical application is monitoring of the power fault contact in the power supply or a fire pump. This unit can be used for: Monitoring of water level detection systems Monitoring of smoke control damper systems Monitoring of extinguishing systems The output unit contains a potential free contact, which can be activated from a detector or a combination of several detectors or other preconfigured cause and effect relationships. No end-of-line monitoring on output function. The output can be used for: Door release Sprinkler control/functions Control of fire dampers FPE/FAD without bell patterns Autronica Fire and Security AS Tel.: +47 90 90 55 00 E-mail: info@autronicafire.no www.autronicafire.com Page 11

Function J ON OFF OFF ON Function: Relay output function (input not in use) Applications: The output unit contains a potential free contact, which can be activated from a detector or a combination of several detectors or other preconfigured cause and effect relationships. The output can be used for: Door release Sprinkler control/functions Control of fire dampers FPE/FAD without bell patterns Function K OFF ON OFF ON Function: Relay output function with activation feedback monitoring. Default delay for change of position is 17 seconds. At activation there is a 30 seconds delay before a technical alarm is initiated. When the door closes an indication of this status is given. When the door is closed, an indication of this status is sent after 120 seconds. All delays are configurable. Applications: Door control and monitoring Fire damper control and monitoring Low location lights control and monitoring Other equipment Function L ON ON OFF ON Function: Relay output function with activation feedback monitoring (output 2 not in use). Both inputs are used to achieve monitoring of both end positions Number of addresses: 1 Applications: Door control and monitoring Fire damper control and monitoring Other equipment Autronica Fire and Security AS Tel.: +47 90 90 55 00 E-mail: info@autronicafire.no www.autronicafire.com Page 12

Function M OFF OFF ON ON Function: Relay output function with activation feedback monitoring (output 2 not in use). The second input is used for external fault input. Number of addresses: 1 Applications: Door control and monitoring Fire damper control and monitoring Low location lights control and monitoring Other equipment Function N ON OFF ON ON Function: Pre Alarm and Alarm condition signalling input unit with feedback function. One input is used for Pre Alarm and the other for Alarm. Relay contacts closes when the pre alarm state or alarm state is entered, and opens when the unit is reset. (Output 2 not in use). Number of addresses: 1 Application include: Pre Alarm and Alarm input from a detector with relay outputs Autronica Fire and Security AS Tel.: +47 90 90 55 00 E-mail: info@autronicafire.no www.autronicafire.com Page 13