May 2016 ENERGY EFFICIENT RETROFIT SOLUTIONS The Power To Supply... All Your Electrical Products www.cef.co.uk All products are subject to availability and are correct at the time of print. Errors and omissions excepted. All prices shown are exclusive of VAT where applicable.
T8 - T5 CONVERSION DIRECT RETROFIT REPLACEMENT SAME PHYSICAL SIZE AS T8 FLUORESCENT NEW T5 LAMP SITS IN AN ADAPTOR WHICH INCLUDES AN H/F BALLAST ANY COMPETENT PERSON CAN INSTALL PART CODE REPLACES ENERGY CONSUMPTION EXISTING FLUORESCENT CO 2 EMISSIONS ELECTRICITY COST ENERGY CONSUMPTION T5 CONVERSION CO 2 EMISSIONS ELECTRICITY COST ELCQ X 2ft Modular 183 kwh 0.08 tonnes 21.96 11 kwh 0.05 tonnes 13.63 ELC2 / ETT2 2ft Fluorescent 56 kwh 0.025 tonnes 6.7 29 kwh 0.013 tonnes 3.9 ELC / ETT ft Fluorescent 91 kwh 0.0 tonnes 10.98 55 kwh 0.025 tonnes 6.62 ELC5 / ETT5 5ft Fluorescent 135 kwh 0.06 tonnes 16.22 58 kwh 0.026 tonnes 6.9 ELC6 / ETT6 6ft Fluorescent 156 kwh 0.07 tonnes 18.72 95 kwh 0.0 tonnes 11.37
Information based on: ELECTRICITY COST: 0.12 per kwh EXISTING LIGHTING SWITCHED ON 5 days per week 52 weeks per year EXISTING LIGHTING OPERATES 8 hours per day USE THE E-MATIC APP for savings information for your site www.ematic.pixelcortex.com/app PAYBACK PERIOD ENERGY CONSUMPTION PER YEAR SAVINGS CO 2 EMISSIONS ELECTRICITY COST ENERGY CONSUMPTION 5 YEAR SAVINGS (INCLUDES EQUIPMENT COST) CO 2 ELECTRICITY EMISSIONS COST NET SAVING 11 months 69 kwh 0.03 tonnes 8.3 35 kwh 0.15 tonnes 1.70 76.00 12 months 27 kwh 0.012 tonnes 3.26 135 kwh 0.06 tonnes 16.30 17.27 12 months 36 kwh 0.016 tonnes.36 180 kwh 0.08 tonnes 21.80 23.53 12 months 77 kwh 0.03 tonnes 9.28 385 kwh 0.17 tonnes 6.0.9 1 months 61 kwh 0.027 tonnes 7.35 305 kwh 0.1 tonnes 36.75 36.72
NEXT GENERATION LED RETROFIT TUBES AUTO SENSE T8 LED Direct retrofit for switch start and electronic ballast Auto sense smart technology No rewire No replacement starter Glass tube technology c/w PET cover UP TO 63% ENERGY SAVING 3 YEAR WARRANTY AS LOW AS17 MONTHS ROI PART CODE TYPE LED TYPE LED QUANTITY OUTPUT POWER CRI ESLED ESLED5 ET5LED2 ET5LED3 ET5LED ET5LED5 T8 Universal T8 Universal T5 T5 T5 T5 2835 0.5W 2835 0.5W 2835 0.2W 2835 0.2W 2835 0.2W 2835 0.2W 108 135 70 128 150 192 18W 2W 6W 10W 13W 18W
T5 LED RETROFIT Direct retrofit No rewire Glass tube technology c/w PET cover Long lifespan UP TO 62% ENERGY SAVING 3 YEAR WARRANTY COLOUR LUMEN SAVING AGAINST FLUORESCENT ROI 5YR SAVING,000K,000K,000K,000K,000K,000K 1,800 2,200 720 1,000 1,300 1,600 59% 63% 62% 56% 56% 51% 22 MONTHS 17 MONTHS 30 MONTHS 23 MONTHS 2 MONTHS 27 MONTHS 25.81 3.30 7.82 1.0 16.08 16.12
T8 LED TUBES FEATURE Glass tube construction 20 beam angle Single end circuit design Bridging unit (replacement starter) supplied Up to 100 lumen per watt PART CODE LENGTH (MM) LED TYPE LED QUANTITY OUTPUT POWER CRI ECLED2 ECLED3 ECLED ECLED5 ECLED6 ECLED8 600 900 1,200 1,500 1,800 2,00 01 01 01 01 01 01 60 90 120 150 180 20 9W 12W 18W 2W 32W 2W
FULL GLASS LED TUBE RANGE UP TO 68% 15 ENERGY SAVING 3 YEAR WARRANTY AS LOW AS MONTHS ROI BENEFIT Lower cost, higher light transmittance, better heat dissipation More even light spread, no need to manoeuvre Safer to install Direct retrofit for magnetic ballast type fittings Lower power consumption for high light output COLOUR LUMEN SAVING AGAINST T8 ROI (PAYBACK) 5 YEAR SAVING,000K 900 66% 1.3 years 20.8,000K 1,200 59% 1.3 years 26.60,000K 1,800 59% 1.3 years 29.66,000K 2,200 63% 1.2 years 5.98,000K 3,000 57% 2.0 years 0.07,000K,000 68% 1. years 96.0
RETROFIT LED CONVERSION PLATES CONVERT EXISTING 5FT FLUORESCENT NON CORROSIVE AND WITH NO NEED TO REPLACE THE EXISTING FITTING... No conduit to change Keep existing cabling Magnetic fixing High lumen output Complete retrofit solution Long life 50,000hrs LED ELED5NCT UP TO 38% ENERGY SAVING PART CODE REPLACES WATTAGE ELED5NC ELED5NCT PM2D10 PM2D10E Single 5ft 58W Twin 5ft 58W 28W 2D 28W 2D 0W 80W 10W 10W
28 WATT 2D FITTINGS INTO ENERGY SAVING LED - Keep existing cabling No redecoration issues Standard or emergency options Universal mounting PM2D10E UP TO 68% ENERGY SAVING LUMEN 3,900 7,600 900 900 / 180 (emergency) COLOUR TEMP 5,500k 5,500k,000k,000k ENERGY SAVING 38% 35% 68% 68%
ULTRA SLIM LINE RETROFIT LED PANELS ELEDS6 Only 6.5mm depth Reduces installation time Perfect retrofit option Allows option for utilising existing cut outs (flush clips also supplied) 168mm Maximum cu t size 150mm White frame 3,000K /,000K / 6,000K 12 watt ALL SUPPLIED WITH DRIVER, MULTIPLE ACCESSORIES AVAILABLE. PART CODE DIAMETER MAXIMUM CUT SIZE WATTAGE ELEDS6 168MM 150MM 12W ELEDS8 217MM 195MM 15W ELEDS12 310MM 290MM 25W
ULTRA SLIM SURFACE MOUNT ELEDS8 217mm Maximum cu t size 195mm White frame 3,000K /,000K / 6,000K 15 watt ELEDS12 310mm Maximum cu t size 290mm White frame 3,000K /,000K / 6,000K 25 watt CRI COLOUR OPTIONS 3,000K /,000K / 6,000K 3,000K /,000K / 6,000K 3,000K /,000K / 6,000K LUMEN 900-1020 1125-1275 2125-2375
LED CIRCULAR PANELS (FLUSH) ALL SUPPLIED C/W DRIVER WITH MULTIPLE ACCESSORIES AVAILABLE 85mm 225mm 170mm 120mm PART CODE DIAMETER (MM) CUT SIZE LED TYPE WATTAGE CRI REPLACES ELED85 ELED120 ELED170 ELED225 ELED300 85 120 170 225 300 75mm 105mm 160mm 210mm 287mm SMD2835 SMD2835 SMD2835 SMD2835 SMD2835 3W 6W 12W 20W 25W 80 80 80 80 80 35W GU10 50W GU10 1 x 26W CFL 2 x 26W CFL 2 x 26W CFL
Slim line: 13mm depth UP TO 91% ENERGY SAVING White and silver frame options Retrofit solutions from 35WGU10 to 2 x 26W CFL Accessories available 3,000K /,000K / 6,000K options AS LOW AS 9 MONTHS ROI COLOUR OPTIONS LUMEN FRAME OPTIONS ROI (PAYBACK) 3,000K /,000K / 6,000K 3,000K /,000K / 6,000K 3,000K /,000K / 6,000K 3,000K /,000K / 6,000K 3,000K /,000K / 6,000K from 230 from 70 from 920 from 1,50 from 1,800 White or Silver White or Silver White or Silver White or Silver White or Silver 9 months 9 months 3 years 1.7 years 3.7 years
LED PANELS NEW IMPROVED SPECIFICATIONS 3 YEAR WARRANTY PANEL (ELEDP600C2) PART CODE SIZE COLOUR TEMP LED TYPE WATTAGE ELEDP600C2/000 600 x 600,000K 5730 38W ELEDP600C2/6000 600 x 600 6,000K 5730 38W ELEDP600C3/000 600 x 600,000K 2835 38W ELEDP600C3/6000 600 x 600 6,000K 2835 38W ELEDP1200C2/000 1,200 X 600,000K 2835 62W ELEDP1200C2/6000 1,200 X 600 6,000K 2835 62W
STURDY CONSTRUCTION SAFETY FIXING CABLE INCLUDED UP TO 5% ENERGY SAVING HIGH QUALITY COMPONENTS 3 or 5 YEAR WARRANTY 5 YEAR WARRANTY PANEL (ELEDP600C2) LUMEN CRI POWER FACTOR VIEWING ANGLE 3,500 3,600 3,100 3,200 5,700 5,900 0.9 0.9 0.9 0.9 0.9 0.9 180 180 180 180 180 180
DRIVERS, EMERGENCY PACKS AND ACCES 600 X 600 PANEL DRIVERS ELEDP600C2/D: Standard replacement 38w driver (ELEDP600C2 Panels) ELEDP600C2/DT: Triac dimming driver (ELEDP600C2 Panels) ELEDP600C2/D10V: 1-10V dimming driver (ELEDP600C2 Panels) ELEDP600C3/D: Contract 38w driver (ELEDP600C3 Panels) 1200 X 600 PANEL DRIVERS ELEDP1200C2/D: Standard replacement 62w driver ELEDP1200C2/DT: Triac dimming driver ELEDP1200C2/D10V: 1-10V dimming driver FLUSH CIRCULAR PANEL DRIVERS ELED/DIM85: Triac / 1-10v dimming driver for ELED85 ELED/DIM120: Triac / 1-10v dimming driver for ELED120 ELED/DIM225: Triac / 1-10v dimming driver for ELED170/ELED225 SURFACE SLIM LINE PANEL DRIVERS ELEDS6/TD: Triac dimming driver for ELEDS6 ELEDS8/TD: Triac dimming driver for ELEDS8 ELEDS12/TD: Triac dimming driver for ELEDS12
ORIES EMERGENCY PACKS ELEDP600C2/EM: 3hr emergency pack for ELEDP600C2 ELEDP1200C2/EM: 3hr emergency pack for ELEDP1200C2 ELEDPEM3: 3hr emergency pack for ELED85 ELEDPEM6: 3hr emergency pack for ELED120 ELEDPEM12: 3hr emergency pack for ELED170 ELEDPEM20: 3hr emergency pack for ELED225 ELEDS6/EM: 3hr emergency pack for ELEDS6 ELEDS8/EM: 3hr emergency pack for ELEDS8 ELEDS12/EM: 3hr emergency pack for ELEDS12 LED DIMMING (SUITABLE FOR E-MATIC DIMMING DRIVERS) PMD1G250: 1G 250w dimmer PMD2G250: 2G 250w dimmer PMD3G250: 3G 250w dimmer PMDG250: G 250w dimmer PMD1G00: 1G 00w dimmer PMD2G00: 2G 00w dimmer PMD1G1000: 1G 1000w dimmer PMD1G1/10V: 1G 1-10v dimmer (16 x drivers)
LED OCCUPANCY FITTINGS Energy efficient LED Microwave IP65 Polycarbonate Opal Diffuser Hinged gear tray Hinged Gear Tray Terminal PART CODE DIMENSIONS LED QTY WATTAGE LUMEN 100% PM60LEDP 33 x 106mm 38 18W 1,5 PM60LEDPD 33 x 106mm 38 18W 1,5 PM60LEDPE 33 x 106mm 38 18W 1,5 PM60LEDPED 33 x 106mm 38 18W 1,5
THE COMPLETE RANGE 18W c/w sensor 18W c/w sensor & 3hr emergency 18W c/w sensor & 10% dimming 18W c/w sensor, 3hr emergency & 10% dimming 3 YEAR WARRANTY Occupancy Sensor IP65 Seal Locking Gear Tray Block on Base Quality Components IP65 Pressure Valve DETECTION DISTANCE LUMEN EMERGENCY LUMEN 10% CRI COLOUR TEMP 2-10m 2-10m 2-10m 2-10m n/a n/a 238 273 n/a 150 n/a 150 6,000K 6,000K 6,000K 6,000K
ULTRASONIC DUAL TECHNOLOGY OCCUPANCY DUAL PIR/US ULTRASONIC technology uses sound waves to detect even slight movement PIR senses changes in temperature emitted by human movement Ultrasonic doesn t require an unobstructed line of site. It can see around corners. Ultrasonic is more sensitive to movement towards the detector Both technologies used (DualTech) ensures minimal false triggering PMUSW No Motion Soundwave out Soundwave in PMUSC Motion Soundwave out Soundwave in COVERAGE PMUSW APPLICATIONS Corridor, hotel lobby, classroom, large conference room, staircase etc. PMUSC APPLICATIONS Open plan office, classroom, multi-stall toilet PART CODE MOUNTING ACCESSORIES SUPPLIED PMUSW PMUSC Wall Ceiling - Surface Base
Rated Voltage SPECIFICATION 230V ~± 10% 50 / 60Hz PIR Load: For lighting control Incandescent Lamp max. 2,000W AC Halogen Lamp max. 1,000W LV Halogen Lamp max. 1,000VA / Fluorescent Lamp max. 900VA / 100µF 25 x (1 x 18W) : 12 x (2 x 18W) 15 x (1 x 36W) : 7 x ( 2 x 36W) 10 x (1 x 58W) : 5 x (2 x 58W) max. 1,000VA / (uncompensated) LED Lamp Energy Saving Lamp Detection Angle Detection Range Auto Off Time Adjustment: Lux Adjustment: ACC ON/OFF: Triggering Methods: (PMUSW) max. 500VA / 00W max. 600VA / 00W PMUSW: 180 PMUSC: 360 PIR adjustable approx. 8m in frontward, approx. 6m in sideward. (PMUSW) US adjustable approx. 8m x 8m Adjustable from approx. 5sec to 30min, Test & t s Adjustable from approx. 10Lux to 1,000Lux Select ON for activating or select OFF for deactivating air current compensation function PIR + US, PIR only, US only, PIR or US Obstructed operational area Ultrasonic Ultrasonic Sensor Frequency: 32KHz Operating Temperature: Environmental Protection: 0 C - +5 C Class II, IP20 Full coverage of area MAX. LIGHTING LOAD MAX. HVAC LOAD TRIGGERING OPTIONS 2,000W 2,000W n/a 10AMP PIR, Ultrasonic, Both PIR, Ultrasonic, Both
RETROFIT OCCUPANCY USE WITH EXISTING LIGHTING FIXTURES... PMSMRH PMSML 2W LED for low output channel orientation light Unit with arm IR Remote included Retrofit design allows mounting on high bay and batten fittings Adjustable up to 10m detection radius IR remote control supplied for easy set up High sensitivity microwave technology LED indication Up to 1,000W Up to 10m mounting height Cost effective alternative to dimming Dual outputs - high output is activated by movement, low output activated by ambient lux level High sensitivity microwave sensor for detecting the slightest of movement Retrofits into existing fittings. No need for additional wiring or decorating etc. Low output is ideal as an orientation or night light in areas such as corridors and stairwells, with the added benefit of switching to high output upon movement Controls all types of lamps including low energy Manual on or off by using additional push button or rocker switch Supplied with 2W low output LED night light Side view Top view Mounted on light fitting Side view Top view Dia: 10m Ceiling mount Dia: 3m 10m 10m 2.5m Major motion 3m 10m Minor motion Dia: 10m Dia: 2m
MICROWAVE OCCUPANCY PMSMCS MICROWAVE (HIGH FREQUENCY) technology detects solid object movement. Microwaves travel through certain materials such as wood, brick, glass and can detect movement through these. Microwaves will not pass through metal. ADVANTAGES Extremely sensitive to even the slightest movement Will see through objects placed in the sensor s path Not affected by change in temperature DISADVANTAGES Can easily be triggered by movement outside of a room if not set up correctly Will see water as a solid object and can see through glass - correct positioning is crucial to avoid false triggers. Top view Side view SPECIFICATION 360 Dia: 3m Dia: 10m 2.5m 5m 1.5m 1.5m 5m Major motion Minor motion Rated voltage Detection range Lux adjustment Auto off time adjustment Operating temperature 230V ~±10% 50/60Hz 10m @ 2.5m height from approx. 10-2,000 lux approx. 5secs - 30mins 0 C - +5 C (indoor usage) -20 C to +5 C (outdoor usage) Environmental protection IP (surface mount with junction box JB-6); APPLICATIONS High level areas, warehouses, open plan office, classroom, multi stall toilet Load: Incandescent lamp HV Halogen lamp LV Halogen lamp Fluorescent lamp PL lamps IP0 (flush mount with spring clip or European standard junction box); max. 2,000W max. 1,000W max. 1,000VA / max. 900VA max. 500VA / 00W
DAYLIGHT DIMMING USED WITH 1-10V DIMMING BALLASTS TO MAINTAIN LIGHT LEVELS AUTOMATICALLY Monitors ambient light and adjusts lighting brightness to maintain constant lighting level Suitable for 1-10v dimming electronic ballasts & LED drivers 360 coverage, 8m range Absence detection function via push switch PMSCDD Enough daylight, occupied - Lighting keeps OFF Decreased daylight, occupied - DIM lighting Night, occupied - Lighting keeps ON with higher brightness Night, unoccupied - Switching lighting OFF
ABSENCE DETECTION USED WITH MOMENTARY SWITCHES TO DETECT ABSENCE AFTER MANUAL ACTIVATION Switch lighting on manually via separate push button Sensor checks for absence then switches off lighting Used in classrooms/meeting rooms PMSCA Switch on lighting manually Lighting remains on whilst occupied Lighting turned off when Absence detected
BLUETOOTH OCCUPANCY USE A SMARTPHONE/TABLET TO SETUP AND MONITOR ENERGY USAGE PMSCBT Ceiling mount occupancy sensor Bluetooth control function Lighting automation control Dimming capability Energy monitor function Controllable through app. The PMSCBT PIR Occupancy Sensor is configured with a Bluetooth interface and user friendly app which enables the user to program it by smartphone or tablet (android). The occupancy sensor automatically switches on the lighting load upon movement and off, after the preset delay time when vacant. Lighting can be dimmed and additional benefits including schedules, holiday mode and energy monitoring options enable the user to maximise energy saving and automation potential.
2 CHANNEL OCCUPANCY SWITCHES 2 TYPES OF LOAD INDEPENDENTLY WITH SEPARATE DELAY TIME ADJUSTMENT PMSCF8 PMSCF20 Lighting and HVAC control Up to 2,000W Incandescent, Halogen, Fluorescent, LED and energy saving loads Auto learn function Pre-wired Manual on/off override via push button Individual channel adjustable detection range, lux and off time Spring clamps for easy and quick installation Ideal for toilets, switching lighting and fans separately Lighting and HVAC control Up to 2,000W Incandescent, Halogen, Fluorescent, LED and energy saving loads Auto learn function Pre-wired Manual on/off override via push button Individual channel adjustable detection range, lux and off time Spring clamps for easy and quick installation Ideal for larger areas and corridors Top view Side view Top view Side view 360 Dia: 2m 360 Dia: m Dia: 8m 2.5m Dia: 20m 2.5m m 1m 1m m 10m 2m 2m 10m Major motion Minor motion Major motion Minor motion
SINGLE CHANNEL PIR OCCUPANCY VARIOUS OPTIONS WITH A SINGLE RELAY OUTPUT WITH PMCSF6 PMCS6 PMCS20 PMSCFS7 PMSCFMINI CEILING - FLUSH includes cable CEILING - SURFACE & FLUSH CEILING - SURFACE long range 20m CEILING - SURFACE & FLUSH CEILING - FLUSH miniature head OCCUPANCY SENSOR ENERGY SAVING EXAMPLE Current Installation Lights on 8 hours per day, 5 days per week. Electricity cost 0.12 per kwh. 5 x 5ft 58W fluorescent tubes. Electricity cost per year: 81.12 Energy per year: 676 kwh
WALL AND CEILING OPTIONS... PMSCF PMSCS PMSCSS PMWS PMWS2W PMPC10 CEILING - FLUSH entry level CEILING - SURFACE entry level CEILING - SURFACE IP66 WALL - 3 WIRE WALL - 2 WIRE (no neutral needed) Photocell 10AMP Stage 1: Change Lighting to Energy Efficient LED Tubes Energy per year: 250 kwh Electricity cost per year: 29.95 Savings: 63.08% Energy saved: 26 kwh per year Electricity saved: 51.17 per year Payback: 1.21 years Stage 2: Add Occupancy Sensor* Occupancy 10% of day Energy per year: 25 kwh Electricity cost per year: 3.00 Savings: 96.3% Energy saved: 651 kwh per year Electricity saved: 78.12 per year Payback: 1.2 years *based on PMCS6 Sensor.
OCCUPANCY SELECTION CHART PMSCF PMCSF6 PMSCF8 PMSCF20 PMSCA PMSCFS7 PMSCS PMCS6 PMCS20 PMSCSS Extreme minor movement Lighting & HVAC channels Standby (low light) channel Long range 1-10V dimmable Surface Flush Retrofit Absence IR remote control Manual on/off override (via switch) Coverage (m) 6 8 20 8 7 6 20 5 Bluetooth control Ultrasonic Miniature sensor head Automatic Dimming CHANNEL 1 (LIGHTING) Incandescent 2000W 2000W 2000W 2000W 2000W 1000W 1 2000W 2000W 1 AC Halogen 1000W 1000W 1000W 1000W 1000W 500W 1000W 1000W LV Halogen Fluorescent (uncompensated) LED 0-200W 200W 00W 00W 00W 200W 250W 300W 300W 300W 0-200W 200W 0-200W 300W 300W 0-200W Energy Saving 0-200W 200W 00W 00W 00W 300W 0-200W 200W 0-200W 0-200W CHANNEL 2 (HVAC) (cos = 1) for <= 250V AC <= 30V DC (cos = 0.) for <= 250V AC 5A 5A 1A 5A 5A 1A 5A 5A 1A Low level channel (standby)
PMWS PMWS2W PMSMCS PMSMRH PMSML PMSCDD PMSCFMINI PMSCBT PMUSW PMUSC PMPC10 Photocell 12 12 2-10 2-10 2-10 8 8 8 2-8 2-16 2000W 2000W 2000W 2000W 2000W 2000W 2000W 2000W 10AMP 1000W 00W 1000W 1000W 00W 1000W 1000W 1000W 1000W 1000W 200W 200W 150W 150W 150W 150W 150W 150W 150W 00W 00W 00W 00W 00W 120W 120W 120W 120W 120W 00W 00W 00W 00W 00W 10 AMP* 5 AMP* 3 AMP* 5W * not a 2 channel unit. HVAC control via jumper cable.
RETROFIT LIGHTING SURVEY APP Web based app Survey details emailed to an address of your choice Use whilst online or offline Use on ipad, iphone, Android, tablet, PC Provides instant energy saving information, payback period and equipment estimates DOWNLOAD IT TODAY! www.e-matic.co.uk