CONSTRUCTION STANDARDS FOR COMMERCIAL FISHING VESSEL

Similar documents
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Fire fighting Questions

FOOD PREPARATION WITHIN EXHIBITS

ORT6WXA ORT9WXA Slide-out Rangehoods

Brandon Fire and Emergency Services

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

MUNICIPALITY OF THE COUNTY OF KINGS

Completed Projects / Projets terminés

Chapter 101 OPEN FIRES

2012 International Mechanical Code Significant Changes. About the Significant Changes

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

OUTLINE FOR FIRE PREVENTION ACTIVITY

OPERATING INSTRUCTIONS AND OWNER S MANUAL

MOBILE FOOD SERVICE EQUIPMENT FIELD APPROVAL SUBMISSION INFORMATION

Dear Exhibitor, To assist in th. and safety issues that you may encounter with your booth.

Emergency Operating Procedures for: Fire and Emergency

Integrated Hood Liner

Ships and marine technology Fireextinguishing. of galley cooking equipment

ISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment

NC Mechanical Code. Land Use and Environmental Service Agency (Code Enforcement) Table of Contents

Top quality for boaters

Annex 4a Common Minimum Technical Competency Requirements for Oil Appliance Installation Work (Domestic)

1. GENERAL SAFETY RULES

CYLINDER NOT INCLUDED

Crosswalk: Weight-Based Rating versus Performance-Based Rating

Protecting Children from Carbon Monoxide Poisoning

City of Cleveland. Division of Fire Fire Prevention Bureau 1645 Superior Avenue Cleveland, Ohio Standard Operating Procedure 18

Special Occupancy Requirements

Integrated Hood Liner

Fire Risks in our Woodshops. Sam Altshuler January 2018

Level I Chapter 1 Worksheet

GIMBALLED GALLEY STOVE

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

This policy is applicable to all DMS-owned, -leased and -managed facilities.

After receiving the following letter from a consulting client a discussion on the subject of CO poisoning seemed in order.

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT

NFPA 45 NFPA 211 NFPA 1600

ISO INTERNATIONAL STANDARD. Hydrogen generators using fuel processing technologies Part 1: Safety

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

BSS Examination Record Form: Non-private Boats (2002 ECP Parts 2 to Part 10)

APPENDIX A FEES SECTION FC A01 CERTIFICATES A01.1

LA-Turbo Downdraft INSTALLATION INSTRUCTIONS

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

DISTRICT/ MUNICIPALITY OF Wood Burning Appliance Bylaw No., 20

All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event.

IMC Significant Changes Summary Tier I

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

USER MANUAL. Cooker Hood ZHG51250GA

OWNER S MANUAL PG9YAA HIGH EFFICIENCY GAS FURNACE ! WARNING SAFETY CONSIDERATIONS

Range hood Instruction Manual

HEATING. Additional heating

2015 MECHANICAL CODE REQUIREMENTS

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON

Address 3255 Pepper Ln., Suite 112 Las Vegas, NV 89120, USA

Exhibits and Trade Shows Permit Application

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

Service life twice as long (6,000 operating hours). Automatic altitude adjustment of the Hydronic M10 / M12 up to 3,500m.

Common Items that May Be Hazardous Descriptions that Indicate Dangerous Goods (Courtesy of UPS)

ORDINANCE NO

REQUIREMENTS FOR EVENTS AND TEMPORARY STANDS AT FAIRS AND SHOWS

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

Impact of Sophia s Law. Recreational Vessels. Vessel Safety Checks

EN Instruction on mounting and use

tççç= ÜÉ~íáåÖ çéíáçåë

FIRE MARSHAL REGULATIONS

(h) Pesticide Application.

Smoke detection in hazardous areas:

Installation and maintenance manual

Laboratory exercise 3: Condensing water heater

SOPHIA S LAW. Nations Toughest Carbon Monoxide Law: Educating Boaters and Changing an Industry

Hot Topic. a Guide to Help Prevent Fire Damage

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels

Government Gazette Staatskoerant

Second Revision No. 3 implements the text of Committee Input No. 36 as proposed in the First Draft Report, along with the following amendments:

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Report on First Revisions with Statement June 2014 NFPA 101

Ashirwad Carbonics (India) Private Limited

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Plant Processing and Extraction Facilities

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

RESOLUTION MSC.44(65) (adopted on 11 May 1995) STANDARDS FOR FIXED SPRINKLER SYSTEMS FOR HIGH SPEED CRAFT

Gas-fired water heaters, volume III, storage water heaters with input ratings above 75,000 Btu per hour, circulating and instantaneous

CITY OF GREATER SUDBURY (CGS) ARENA EVENTS FIRE REGULATIONS

C0-210 Carbon Monoxide Probe

GASEOUS HYDROGEN SYSTEMS

CRAFTSMAN EXAMINATION, NOVEMBER 2009 GASFITTING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

carbon monoxide Preventing carbon monoxide poisoning in your home

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2012 EDITION

What Does Propane Smell Like?

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

L O S S C O N T R O L

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Cookshack, Inc. Model FEC100 Fast Eddy Oven. Version /1/10

Transcription:

Transports Canada Région du Québec Sécurité maritime Transport Canada Quebec Region Marine Safety CONSTRUCTION STANDARDS FOR COMMERCIAL FISHING VESSEL Ventilation systems, cooking, heating and other domestic appliances Section 6.0 Accommodation ventilation (6.8) -Ventilation required with minimum duct size without regards to fuel burning appliances -Additional requirements if the crew spaces and the engine room are in adjoining compartments vessels < 15.2 m -Suitable ventilation, no minimum required vessels < 15 grt Proposed requirements: -Ventilation required in addition to conventional means -Increase in duct size for each berthed crew member -Minimum effective area offered by air ducts fuel burning appliances -Provisions made for mechanical means of forced ventilation -Every space containing a toilet natural ventilation 1

Accommodation ventilation (6.8) -A vessel which is fitted with an enclosed accommodations space and a gasoline inboard engine, an LPG appliance or any fuel burning appliances with a non-sealed combustion chamber shall be fitted with an explosive or noxious gases detection system. The system shall be UL/ULC/CSA approved and give both audible and visual alarm at the control station. Impacts: -Low to moderate cost wise -May create design or construction related problems Engine room ventilation (6.3) -Gasoline fuelled engine the engine compartment shall be mechanically force ventilated before starting the engine -Suitable air supply minimum duct size required >15 grt Proposed requirements: -Gasoline fuelled engine in addition to the actual requirements minimum air flow and ventilation time must be observed and a visual indicator available when the blower is operating 2

Engine room ventilation (6.3) - Air supply and exhaust Provisions made for ducts layout Ducts cross sectional area related to machinery needs including a minimum cross sectional area applicable Provisions made for materials used in ducts and components >12 m ducts made of metallic material Provisions made for cowls and ventilation openings -Impacts: moderated cost wise May create new construction or refurbishing related problems Ventilation for open spaces vessel construction (6.3.3) None Proposed requirements : -A separate ventilation system is not required if some design requirements are met (size of open area) Impact: -Very low applies to only a very small portion of the fleet 3

Battery spaces ventilation (6.7) Requirements stated at section 8: Cooking, heating and other domestic appliances (6.6) - Suitable supply of air needed to fulfilled the combustion process - free circulation of air all around the appliance and all inflammable material nearby must be insulated - Liquefied petroleum gas systems to meet the marine machinery regulations >15 grt and a certificate of compliance issued by an approved organisation <15 grt Proposed requirements: - Cooking, heating and other domestic appliances shall be electrically operated except where the installed generator capacity is inadequate 4

Cooking, heating and other domestic appliances (6.6) Fuel burning appliances shall be accepted subject to the following 1. Type of fuel Solid fuel coal, charcoal or wood these are prohibited on gasoline installation Liquid fuel allowed diesel et Kerosene oil prohibited gasoline, alcohol and naptha Gaseous fuel allowed liquefied petroleum gas prohibited compressed natural gas Cooking, heating and other domestic appliances (6.6) 2. Appliances general particulars appliances designated for marine use and listed by a recognized agency such as UL/ULC/CSA and installed in accordance with manufacturer s recommendations provided with a flame failure device which will provided an automatic shut-down of all burner operations and a means of automatic shut-off of the fuel supply on detection of high temperature or flame failure operator intervention required to restart a burner 3. Appliances specific particulars stoves continuously lighted pilot lights are prohibited except for appliances using sealed combustion chamber space heaters sealed combustion chamber type designed only 5

Cooking, heating and other domestic appliances (6.6) 4. Installation general specifications appliance installation free circulation of air all around the appliance and all inflammable material nearby shall be insulated exhaust ducts provided with draughts limiting devices and shall be insulated supply of air related to appliance needs and each berthed crew member fuel supply shall be in accordance with the requirements of section 7.0 printed instructions for operation and safety instructions shall be permanently mounted in a location adjacent to the appliance Cooking, heating and other domestic appliances (6.6) 5. Installation specific particulars Stoves provided with steel exhaust fan and hood. The hood or duct shall be fitted with a grease trap shall not be used for spaces heating purposes shall not be installed in dedicated sleeping spaces 6. Special requirements for appliances using liquefied petroleum gas no more than two 10 kg containers shall be carried on board shall not be used in dedicated sleeping spaces shall be installed to provincial gas enforcing authority standards 6

Cooking, heating and other domestic appliances (6.6) Impact: Some items can only be purchased as special equipment end up being expensive for all concerned vessels Limited use small vessels where berthed spaces open to the galley THANK YOU Bernard Leclerc Marine Inspector Transport Canada / Marine Safety 180, de la Cathédrale, Rimouski, G5L 5H9 418-722-3040 or 1-800-427-4417 leclerb@tc.gc.ca 7