The Use Of Attic Space For Cooling and Dehumidification

Similar documents
Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Experimental Performance of Solar Collector cum Regenerator for Coupling with a Liquid Desiccant Cooling System

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Compressor Capacity Control

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

Efficiency of Non-Azeotropic Refrigerant Cycle

Air-Cooled Heat Exchanger Performance for R410A

A study of radiant cooling for a room with daytime application in tropical climate

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Purdue e-pubs. Purdue University

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

A New Control Approach for a Direct Expansion (DX) Air Conditioning (A/C)System with Variable Speed Compressor and Variable Speed Supply Fan

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

HSPF Calculation of a System Allowing Switching Between a Single-Stage to a Two-Stage Compression System

Chapter 10. Passive Cooling Contents

Study on an Air-Side Heating Source Liquid Desiccant Regeneration Model

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

K.F. Fong *, C.K. Lee, T.T. Chow

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Screw Compressor For Ammonia-Water Heat Pump Lubricated By The Process Mixture

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

developed, and parametric studies are conducted with the model. Based on the parameter study results, a dehumidification performance diagram is propos

Desiccant Cooling with Solar Energy

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

NISTIR Mathematical Analysis of Practices to Control Moisture in the Roof Cavities of Manufactured Houses

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Low GWP Refrigerants for Air Conditioning Applications

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

System Using Exhaust Heat from Residential GHPs

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Heat Transfer of R-22 and Alternatives in a Plate- Type Evaporator

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Real Time Upright Freezer Evaporator Performance Under Frosted Conditions

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Recent Advances in Energy, Environment and Economic Development

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Green Roofs Impact on Buildings Cooling Load

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Fifteen Years of Dehumidification Results from Heat Pump Water Heaters

Design Optimization of Variable Geometry Microchannel Heat Exchangers

High Efficiency R-134a Compressor for Domestic Refrigerator

Low Global Warming Refrigerants For Commercial Refrigeration Systems

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

AR/IA 241 LN 231 Lecture 6: Passive Cooling

So far, we have covered the basic concepts of heat transfer and properties.

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Potential and Simulation of Open-Cycle Solar-Assisted Climatisation-Plants in Single-Family-Houses

System Modeling of Gas Engine Driven Heat Pump

An Experimental Study of the Air-Side Particulate Fouling in Fin-and-Tube Heat Exchangers of Air Conditioners

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Review of Temperature and Humidity Control Technology for Heat Pump and Air Conditioning Systems

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Dynamic Simulation of Liquid Chillers

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

HYGROTHERMAL PERFORMANCE BENEFITS OF THE CELLULOSE FIBRE THERMAL INSULATION STRUCTURES

Sub-Critical Operation of the CO2 Expander/ Compressor

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

Purdue e-pubs. Purdue University. Yoshinori Hamamoto Kyushu University. Hideo Mori Kyushu University. Fumio Matsuoka Mitsubisi Electric Corporation

ω = (1) Kirby S. Chapman Ph.D.

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER

Evaluation The Effect Of Washing On The Heat Transfer Capacity And Air-Side Flow Resistance Of Air Cooled Condensers

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Compressor Capacity Control: A New Direction

Effect of magnetic field on the performance of new refrigerant mixtures

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2002 The Use Of Attic Space For Cooling and Dehumidification H. F. Abaza Virginia Polytechnic and State University Follow this and additional works at: http://docs.lib.purdue.edu/iracc Abaza, H. F., "The Use Of Attic Space For Cooling and Dehumidification" (2002). International Refrigeration and Air Conditioning Conference. Paper 536. http://docs.lib.purdue.edu/iracc/536 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

R2-6 THE USE OF ATTIC SPACE FOR COOLING AND DEHUMIDIFICATION Hussein F. Abaza, Ph.D., Research Specialist, Virginia Polytechnic and State University 1405 Bayside Ave. Apt #12, Woodbridge, VA 22191,USA, Tel: 703/498 3084; Fax 703/550 1288 E-mail:habaza@vt.edu Abstract Traditionally, attic space in buildings is perceived as a source of nuisance where the moisture condensation occurs in winter encourages mildew growth, and heat build up in the attic space in summer increases the cooling load. However, if the attic is integrated in a holistic design and control strategy, it can function as a solar collector, a heat exchanger, and a desiccant!. This research investigates energy saving by optimizing direct and indirect ventilation through attic to pre-cool buildings and reduces humidity. This strategy was examined in a double story house with attic in a moderate- humid climate. The built up heat in the attic space and outside air ventilation were used to dry up roof construction materials during the day. When outside air cools down during the night but maintains high humidity, the indoor air circulates through the attic space. The attic construction materials absorb moisture from the indoor air. Thus indoor air loses both heat and moisture. EnergyPlus Simulation software was used to simulate this cooling and dehumidification strategy. The simulation results showed significant passive cooling and dehumidification in the building. Key notes: Dehumidification, Nighttime ventilation, Indirect Ventilation, Cooling load Introduction Traditionally, utilizing nighttime ventilation and thermal mass is a major strategy for passive cooling in dry climates. However, in moderate and humid climates, passive cooling through ventilation is more difficult to achieve. In these climates, the outside air is relatively cold during the early evening, but its relative humidity is high. Therefore, it is not suitable for nighttime ventilation. Later at night, outside relative humidity reaches the upper limit of the comfort zone, but the outside air enthalpy remains equal or more than the inside air enthalpy. Thus, introducing outside air to the space may reduce the inside air temperature without reducing the air enthalpy. Instead it could lead to more moisture absorption by inside building materials and furniture [1]. In the daytime, more moisture is produced inside the building due to the required ventilation and other inside latent energy sources. In most cases, dehumidification is needed to extract the excess moisture. Thus, more active cooling is needed to extract the extra moisture, which is admitted to the space during nighttime ventilation [2]. Conventional building materials usually store heat efficiently for short period of time. However, moisture content of building materials and furniture varies widely in their capabilities to store moisture. In addition, to achieve comfort, the air temperature tolerance in a space usually should not exceed 8-11 Fº(5-6 Cº), but the comfort level can be achieved with wide relative humidity range of approximately 30-60%. Thus, the "enthalpy storage" capacity of the building materials can significantly contribute to cooling load. In addition, during the day where active cooling is required, if inside relative humidity is lower, thermal comfort can be achieved at higher air temperatures, and less dehumidification is required. During sunny winter days, solar radiation heat gain in the attic space may exceed the conduction and convection heat loss. Thus attic space will act as a passive heating collector. In summer, the attic space can work as a desiccant, here, the desiccant materials are the attic wood construction, and the regeneration energy is the solar energy collected in the roof. Summer Dehumidification Unlike heat transfer in building materials, which is clearly defined, moisture transfer in buildings is rather complex and involved many mechanisms that are still not fully explained [3]. There are at least 9 different mechanisms of water transport in solids which are; molecular vapour diffusion, molecular liquid diffusion, capillary flow, Kundsen diffusion, surface diffusion, Stefan diffusion, evaporation condensation, Poiseuville flow, and movement due to gravity.

To get a general idea of moisture transfer in building materials and to explain the concept of using the attic space to dehumidify buildings let us consider the following example; In a typical clear sky summer day in a moderate climate, if the outside air temperature reaches 90Fº(32Cº) and relative humidity of 50%, the attic air temperature in a typical wood building can reach 108Fº(42Cº) and relative humidity 29%. During the night, if the air inside the attic is mixed with the house living space, we can assume that relative humidity in the attic will equal the living space relative humidity and let us say that it is 50%. Under steady state condition, the moisture isotherm curve shows that moisture content in the particleboard insulation will drop from.08 to.05 lb/lb (kg/kg) [4]. Isetti showed that the particleboard could approach the steady state in 12 hours [1]. This suggests that in a house with a roof area of 861 F² (80 m²), if the relative humidity fluctuated between 50% and 29%, roof particleboard insulation will have a daily moisture capacity of approximately 353 lb (160 kg) of water. From another hand, the wood attic construction has also high moisture absorption capacities, which can reaches.15 lb/lb (kg/kg) under relative humidity of 50%, and.1lb/lb (kg/kg) under relative humidity of 29% [4]. In addition, wood can reach the balance point in more than 3 months [5]. In this case attic wood construction can contribute to moisture control in the short and the long term. Thus, in a typical wood house with attic space, moisture capacity of the attic construction materials is more that moisture produced in the house due to ventilation and internal latent heat gain (Figure 1)(Figure 2). The moisture balance in buildings can be defined by the following equation [6]; n ci n V V = G ( ci cu) β ( ci csur) A dt 3600 i= 1 Where ci = moisture content in indoor air lb/ m³ (kg/m³) t = time(s) V G = Building volume ft³ (m³) = moisture production lb/s (kg/s) N = air change per hour cu = moisture content in outdoor air lb/ft³ (kg/m³) β = moisture resistance from air to material ft/s (m/s) csur = moisture content of air in material lb/ft³ (kg/m³) A = area of material in room ft² (m²)

Vapour Pressure = 2.3 Kpa Air Temperature = 26C Relative Humidity = 60% Mass Flux = -.002kg/s/m² Vapour Pressure = 2.3 Kpa Air Temperature = 36C Relative Humidity = 33% Mass Flux =.001 to +.0015kg/s/m² Vapour Pressure = 1.3 Kpa Air Temperature = 20C Relative Humidity = 50% Figure1: Moisture transfer and Air circulation in a typical house during the day. Figure2: Moisture transfer and Air circulation in a typical house during the night. Vapour Pressure = 1.4 Kpa Air Temperature = 13C Relative Humidity = 90% Mass Flux = Vapour Pressure = 1.3 Kpa Air Temperature = 15C Relative Humidity = 80% Mass Flux = +.0015kg/s/m² Vapour Pressure =.96 Kpa Air Temperature = 17C Relative Humidity = 50% Figure2: Moisture transfer and Air circulation in a typical house during the night.

From the equation above, to make sure no moisture build up in the space, building moisture production due to ventilation and other building activities should be less than or equal to the moisture absorption of building interior materials. The moisture production in a house may range between 32-53 lb (14-24 kg). In order to flush the extra moisture, which is produced during the day in the living space, the internal building material and furniture shall also accommodate the moisture production in the house during the day. Nielson showed that this is achievable if considering the internal building material and furniture [6]. Testing To predict the yearly dehumidification cycle through attic space, Energy Plus simulation software was used to simulate a simple two-floor house with a floor area of 2691 ft² (250m²) and an attic space. An actual yearly weather data for Roanoke, Virginia was used. This climate is relatively cold in winter, and warm and humid in summer. Energy Plus, the official Department of Energy building simulation software is used to simulate heat transfer, moisture transfer, and air movement in the house. Energy Plus combines the best of DOE-2 and PLAST, and it has the capability of simulating moisture transfer in buildings and cross mixing airflow between building spaces [7]. The proposed house construction is mainly wood. The walls are composed of 13mm wood cladding from outside, R13 glass fibers insulation faced with building paper, and 13mm gypsum board from inside. The floor of the main level is constructed of a composite concrete and wood structure. It consists of 10mm plywood over to 100x250mm wood joists. The windows are composed of double-glazing with 30mm cavity and adjustable bronze blind inside this cavity. This window design allows for controlling the solar radiation admitted through it. The attic roof is composed of black asphalt shingles placed over 13mm wood. The attic floor consists of 150mm re-circulated paper particleboard insulation and 20mm wood board. An outside air controller is scheduled to control the air flow rate in the attic, which was scheduled to operate introduce outside air flow rate of 5.29 ft³/s (.15m³/s) between 12pm and 7pm. A cross mixing airflow of 1.6m³/s was also scheduled to operate between the living space and the attic between 1 am and 6 am. To account for long-term moisture sorption and desorption, the house was simulated for a full year in a passive mode. Results Under the new ventilation and dehumidification strategy, the house maintained a comfort Predictive Mean Vote between -.5, +. 5 for more than 95% of the entire cooling period (Figure 4). The simulation results also showed that during summer when the average outside relative humidity was 85%, the average relative humidity in the house living space was 61%(Figure 4). Further more, when outside air humidity ratio reached.018 kg/kg, the house living space maintained a humidity ratio of less than.011 lb/lb (kg/kg) (Figure 3). The mass flux rate of the roof plywood was approximately between 0.024 to 0.033 lb/hour (-0.001 to +0.015 kg/hour), and the mass flux rate of the insulation was between approximately 0.001 to.007 lb/hour (-0.0003 to +0.0003 kg/hour) (Figure 6). This result suggests that the attic structure has higher moisture content fluctuation than the roof particleboard thermal insulation, which is placed, on the attic floor. That is because plywood in the attic roof is in direct contact with the roof asphalt shingles; hence its temperature is higher than the insulation temperature. The simulation results showed that the humidity ratio fluctuation of the roof building materials was low (Figure 6). This suggests that there will be no negative effect of the new dehumidification mechanism on the roof construction. It also suggests that roof-building materials has the capabilities of balancing the building relative humidity for long periods. Unlike building sensible thermal mass which can store heat for short periods of time (12-24 hours), building latent thermal mass continue to balance the house moisture content for long time periods. Figure 4 and figure 5 show how the house interior maintained low air moisture content and low relative humidity even when the outside air maintained high air moisture content for more than 8days. When comparing the house performance before implementing the new dehumidification strategy, the overall annual latent cooling load reduction of the new dehumidification strategy is approximately 83%. Recommendations This research introduces a new approach of utilizing natural ventilation through attic space to reduce latent cooling load. The new approach makes attic space a source of energy saving rather than a source of nuisance. Other advantages of this strategy is utilizing indirect nighttime ventilation when the outside air is cold but humid, thus outside air is used for cooling without admitting more moisture to the space. Since air pollution diffusion has similar

mechanism to moisture diffusion, better air quality will presumably be achieved through this ventilation strategy. However further research is needed to measure the air pollution desorption and absorption. Figure3: Comfort Predicted Mean Vote (PMV) in the house living space.

Figure4: The air Temperature and relative humidity, which are predicted by simulation. Figure5: Humidity ratio in the living space ant the attic.

Figure 6: Moisture flux and surface humidity ratio in the attic and living space. References [1] Isetti, C., Laurenti, L., and Poticiello, A., 1988, Predicting Vapour Content of the Indoor Air and Latent Loads for Air-conditioned Environments: Effect of Moisture Storage Capacity of the Walls Energy and Buildings, 12, pp 141-148. [2] Bailey, D., Bauer, F., and Slama, C., 1996, Investigation of Dynamic Latent Heat Storage Effect of Building Construction and Furnishings ASHRAE Transactions, v 102, n2, pp 133-141. [3] Planther, P., 2000, Modeling Water Vapour Conditions In Dwellings PhD thesis, University of Westminster, London, United Kingdom. [4] Burch, D., Desjarlais, A., 1995. Water-Vapour Measurements of Low-Slope Roofing Materials Building and Fire Research Laboratory, National Institute of Standard and Technology, Gaithersburg MD, USA. [5] Arfvidson, J., 1999. A New Algorithm to Calculate the Isothermal Moisture Penetration For Periodically Varying Relative Humidity at the Boundary Nordic Journal of Building Physics, Vol. 2. Sweden. [6] Neilsen, A., 1999. 3D Room Model for Moisture Balance Calculations 5 th Nordic Building Physics Symposium, Goteborg, Sweden. [7] Energy Plus, 2002, EnergyPlus Manual Ernest Orlando Lawrence Berkeley National Laboratory, Version 1.0, USA.