MERLIN RANGE KITCHEN EQUIPMENT CT1200S CT1250

Similar documents
Troubleshooting Guide

Troubleshooting Guide

MERLIN RANGE GAS DETECTION EQUIPMENT

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

ULTRAFLUE ACCLAIM GAS COAL CONVECTOR

Boiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Read these instructions carefully before operating or servicing.

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Gas interlock system S & 100 CS

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

100 Series Gas Ventilation Interlock System

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Gas Safety Devices & Accessories

Installation Instructions

VGPS-evo V3.3. Installation Instructions. The VGPS-evo is a gas pressure proving system with ventilation interlock and optional CO2 detection.

Installation Instructions. The SEC-L is a gas pressure proving system with water and electric isolation, gas detection and ventilation interlock.

12W Round LED Wall/Ceiling Light with Microwave Sensor

PGR-8800 TECHNICAL FAQ

Catalogue. ActionpacEMSStandard. Electro Mechanical Control & Monitoring System.

18W Round LED Wall/Ceiling Light with Microwave Sensor

GPPS-evo V3.3. Installation Instructions

GS100M Gas Detector. Technical Specification

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

CaterSense 03 & ATSC-02-xx

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

Please read this sheet as it contains important information

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Heat Pump Defrost Board Replacement Kit

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

CentaurPlus C21 Series 2 User Operating Instructions

Lo-Carbon Sentinel Kinetic Horizontal

, ,

Version 2.2. Radiator Valve (TRV) Model No. LW922. Instruction Manual. Professional Series.

CentaurPlus C27 Series 2 User Operating Instructions

iheat 25c iheat 30c iheat 35c

Submittal Data Performance Data Electrical Data

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SENSA MRE DDM MR

MWS3A-PRM Product Guide

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

Kair Single Room Heat Recovery Ventilator

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Axiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL

Four Channel Gas Detection System AGDS 4. The Home of Control & Automation in Ireland

Lo-Carbon Sentinel Kinetic Range Overview

BX444-Mc Gas Detector

ASSURE HP/COMBI CONCEALED DIGITAL ONE OUTLET CONTROL INSTRUCTION MANUAL Model:

All alerts are still logged as alarms and also show up in the current alarm list.

User's Instructions. Alpha CB50

Operator Guide E-P OneTouch Controls

The Sentinel Kinetic Horizontal Range

SWITCHLITE MRE SLDM ADJ

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

Smoothflow Student Fume Cupboard Installation Instructions

Volume MATHEWS COMPANY. Legacy Series L1250 /L1350 /L2550 /L2650 /L2700 /L3100 /L3105 /L4145 /L5175. Operations Manual

SAT- 3 Installation Setup Guide

HOT CUPBOARD WITH BAIN MARIE

The V-series of rack ovens

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

Settings and Maintenance of the CombinAir

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

1 (5) Exhaust Fans. Example Implementation with Lonix Technologies. Example Application 01/2009. Exhaust Fans

BX444-M Gas Detector. Features. Application. Operation

Manitex Operation Manual

Controlled Thaw Cabinets

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

Plant Growth Cabinets

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

PROFIRE BMS Controller

Thank you for choosing EnviroVent

Operating Instructions

Mini oil filled radiator OR320-6

. w. POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL

Construction Electrical

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

FX BLAST CHILLER ISO ISO 9001

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Installation & Maintenance Manual

Greenstar 12i/24i System

OPERATING INSTRUCTIONS

GS100M Gas Detection Controller

Transcription:

MERLIN RANGE KITCHEN EQUIPMENT CT1250 CT1200S

MERLIN RANGE

CT1250 KITCHEN EQUIPMENT Merlin CT1250 The Merlin CT1250 ventilation interlock system, with built in current monitoring, is designed specifically for use in commercial kitchens to meet BS6173: 2001, which is now a much-recognised standard in the catering industry. This panel is to be used when the kitchen appliances do have flame failure devices, therefore Gas proving is not a requirement. The Merlin CT1250 acts as an interlock between the ventilation system and the gas solenoid valve. The system has a built in power monitor which is a method used for interlocking a kitchens gas supply with the ventilation system. As an alternative to pressure differential switches the CT1250 is designed to monitor the electrical current going to a ventilation fan. When the fan is turned on the CT1250 monitors the electrical current going to the fan motor, when there is sufficient current going to the fan motor our panel receives a signal to indicate the fans are operating. Turning the key to the on position will open the gas solenoid valve. If the fans should fail, the fan fault LED on the panel will illuminate and the gas solenoid valve will close. When there is a fan fault the supply fan or extract fan led on the Merlin CT1250 panel fascia will flash. This informs the electrician or kitchen staff which fan has failed. Key features of the Merlin CT1250 Allows Compliance with BS6173: 2001 for commercial kitchens Clear LED display for system indications Complete all in one box Can be used when pressure differential switches cannot be used e.g. wall-mounted fans Reliable method of interlock, with no moving parts there s little to go wrong Straightforward to install and calibrate. The CT1250 can be easily adjusted to the users requirements This method is not recommended with belt driven fans Easy installation BMS Terminals Normally Closed or Normally open and common. Will accept remote emergency shut-off buttons Three year warranty All Merlin systems are designed to comply with the latest CE requirements and low voltage directives Operating the system in the above manner will ensure the requirements of BS6173: 2001 are fully met where all the catering equipment has flame failure devices fitted. Installation for the Merlin CT1250 is easy as there is no calibration. Wiring of the system is straightforward using volt free connections for all BMS and remote emergency stops. A corgi-registered installer would be required to fit the gas solenoid valve. All panels and gas solenoid valves supplied by S&S Northern carry a full 3-year manufactures warranty. Current Monitoring Calibration of the current monitor is easy, once wired set the fan speed controller to setting 1 (or low setting) for example. Turn the blue rotary switches anti-clockwise until the green LED goes out, then slowly turn clockwise until the green LED is again illuminated. This will give you the minimum current requirement, if the fan is turned off the LED will go out, send a signal to the Merlin panel, which will in turn shut off the gas.

MERLIN RANGE Merlin CT1200S The Merlin CT1200S ventilation interlock system is designed specifically for use in commercial kitchens to meet BS6173: 2001, which is now a much-recognised standard in the catering industry. This panel is to be used when the kitchen appliances do have flame failure devices. Therefore Gas proving is not a requirement. The Merlin CT1200S acts as an interlock between the ventilation system and the gas solenoid valve. It ensures the gas solenoid valve cannot be opened until the ventilation system is proven to be operating. The fans are monitored with air pressure differential switches. To operate the Merlin CT1200S the fans should be turned to the on position, once our panel receives a signal to indicate the fans are operating turn the key to the on position this will open the gas solenoid valve. If the fans should fail, the fan fault LED on the panel will illuminate and the gas solenoid valve will close. When there is a fan fault the supply fan or extract fan led will flash to inform the electrician or kitchen staff which fan has failed. Operating the system in the above manner will ensure the requirements of BS6173: 2001 are fully met where all the catering equipment has flame failure devices fitted. Installation for the Merlin CT1200S is easy as there is no calibration. Wiring of the system is straightforward using volt free connections for all air pressure differential switches and remote emergency stops. A corgi-registered installer would be required to fit the gas solenoid valve. All Gas solenoid valves supplied by S&S Northern carry a full 3-year manufactures warranty.

CT1200S KITCHEN EQUIPMENT Service If an air pressure differential switch goes into alarm (indicating fan fault) and drops the gas solenoid valve this indicates a fan fault. If however upon inspection it is found the fan is operating correctly and the fault lies with the air pressure differential switch a service facility is available. An Electrician can bypass the air pressure differential switch by opening the panel and turning on the service switch this allows gas to be used until the situation can be resolved. The service switch will give the kitchen gas until an electrician has resolved the problem with the airflow switch or any fan fault, which may need tending to. Air pressure differential Switch (volt free) We only supply the highest quality air pressure differential switches for increased longevity and reliability. Electrical connections are made by use of two-core cable. Incorporated in the Merlin CT1200S is a 30 seconds Airflow dropout delay. In the event of interruptions to airflow for less than 30 seconds the delay will allow the gas solenoid valve to remain open, preventing nuisance tripping. Should the airflow be interrupted for 30 seconds or more the fan fail LED will illuminate and the gas solenoid valve will close. Key features of the Merlin CT1200S Complies with BS6173: 2001 for commercial kitchens Clear LED display for system indications Interlocking with fans using Air pressure differential switches. Easy installation BMS Terminals Normally Closed or Normally open and common.

MERLIN RANGE 7 1 6 2 3 4 5 6 5 7 Merlin CT1250 Wiring Diagram 1 230v AC Supply 1 230v AC Supply 2 230v AC output to valve 3 Terminal for BMS connections 4 Remote emergency stop Input 5 Fan sensor input- close when fan on (for use with PD switches) 6 Pots are adjusted to increase or decrease sensitivity 7 Live wire going to the fan goes in and back out onto the fan Merlin CT1250 Dimensions Height 254 mm Length 178 mm Depth 62 mm

CT1250 & CT1200S KITCHEN EQUIPMENT 1 2 3 4 5 5 Merlin CT1200S Wiring Diagram 1 230v AC Supply 2 230v AC output to valve 3 Terminal for BMS connections 4 Remote emergency stop Input 5 Fan sensor input- close when fan on (for use with PD switches) Merlin CT1200S Dimensions Height 113 mm Length 163 mm Depth 62 mm

for safety & service contact: s&s northern head office: unit 2 - dickinsons industrial estate - coppull - chorley - PR7 5AL t 01257 470 983 f 01257 471 937 e info@snsnorthern.com w www.snsnorthern.com southern division: 42 towerfield road - shoeburyness - essex - SS3 9QT t 01702 291 725 f 01702 299 148