Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

Similar documents
SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

MERIT SERIES Up Flow / Horizontal

ELITE SERIES Upflow / Horizontal - Two-Stage Heat

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17.

AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

ML 1 80 UH 070 X E 36 B

MERIT Series R-410A - Upflow / Horizontal

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Heavy Duty Transformer. Low Voltage Circuit Breaker. Visit us at For the latest technical information,

MERIT SERIES Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

MERIT SERIES Downflow

CB X 32 mv

MERIT SERIES Up Flow / Horizontal

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

ELITE SERIES Downflow - High Efficiency Blower Motor

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

ML 1 93 UH 070 x P 36 B

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

8+* Bulletin No November 1997

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

MERIT SERIES Upflow / Horizontal

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

MERIT SERIES Upflow / Horizontal

13 GEP A L P - 1 A

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

C22 Bulletin # October 1993 Supersedes May 1993

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

RGE 13 A T - 1 A

C22FC Bulletin # October 1993 Supersedes May 1993

2 shp 13 lc 1 36 t - 1 a

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

T P A 120 S 4 S N 1 Y

INSTALLATION INSTRUCTIONS

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

GSR21Q PULSE21 SERIES

T S A 048 S 4 N 4 1 T

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

G34M Bulletin #69/ August 2003

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

14 AC x

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

ELITE Series R-410A - Two-Stage Compressor

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

MERIT SERIES Downflow

T P A 048 S 4 N 4 1 T

AFUE 95% Heating Input 50,000 to 200,000 Btuh

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

MERIT SERIES Upflow / Horizontal

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

Product Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140

GREEN REFRIGERANT R-410A

HIGH EFFICIENCY AIR HANDLER

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

CBX32MV (HFC-410A) SERIES UNITS

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

Visit us at For the latest technical information,

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

PRPHP16 PRODUCT SPECIFICATIONS PRP HP P A TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER MINOR REVISION SEQUENCE A = 1ST GENERATION

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Transcription:

WTER HETING / OILERS CWMV PRODUCT SPECIFICTIONS Residential Hot Water Heat ir Handler ulletin No. 0434 ugust 05 Supersedes June 04 Heating Capacity - 3,700 to 0,000 tuh Nominal dd-on Cooling - to 5 Tons MODEL NUMER IDENTIFICTION CW M V - 4-070 - 3 Unit Type CW = ir Handler with Hot Water Coil Minor Revision Number Configuration M = Multi-Position lower V = Variable Speed lower Nominal Water Coil Heat 040 = 40,000 tuh 070 = 70,000 tuh 090 = 90,000 tuh 00 = 00,000 tuh 0 = 0,000 tuh Nominal Cooling Capacity - Tons 04 = tons 036 = 3 tons 060 = 5 tons Cabinet Width = 7-/ in. C = in.

FETURES CONTENTS lower Data... 9 Dimensions... 6 Dimensions - Furnace/Coil Combined Combinations... 8 Electrical Data... 5 Features... Field Wiring... 5 Heating Performance... 0 Installation Clearances... 5 Model Number Identification... Optional ccessories... 5 Optional ccessory Dimensions... 7 Specifications... 5 C WRRNTY ll covered components - Limited warranty for ten years limited warranty in residential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. SEQUENCE OF OPERTION CWMV includes supply air blower, hot water coil, and blower control. circulating pump can be ordered extra for field installation. fter a 45-second (fixed) timed-on delay the blower energizes at heating speed. fter a 30-second (fixed) timed-off delay the supply air blower shuts off. PPROVLS Units certified by CS International. lower data from unit tests conducted in Lennox Laboratory air test chamber. PPLICTION CWMV can be used with properly sized gas-fired or oil-fired water heating devices. Cannot be used with potable water. Supply air blower moves the return air past the coil to extract the heat and then distribute the heated air throughout the conditioned space. CWMV is a multi-position (upflow, downflow, or horizontal) blower/hot water coil unit. Lennox add-on indoor coil with remote air conditioning unit, air cleaners, automatic humidifier, and all Lennox Indoor ir Quality products can easily be added for a complete all season system. Zoning pplications Units may be used with certain zoning systems. Zone control panel must be able to interface and communicate with the variable speed blower motor in the unit. Lennox Harmony III Zoning System has this capability. E HETING SYSTEM Hot Water Coil Corrugated/lanced aluminum fins. Seamless corrosion resistant copper tubes. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections and silver soldering provides tight, leakproof joints. Factory tested under high pressure. Entire coil accessible for cleaning. Freezestat Protects system from freezing temperatures when unit is installed in unconditioned areas. Thermostat automatically energizes circulating pump when water line temperature falls below 45 F. Optional ccessories Circulating Pump ronze construction, Non-metallic impeller with Carbon bearings. Self lubricating. Impedance protected. D Motor and impeller removable as single unit for servicing. CWMV / Page

C FETURES CINET Heavy gauge cold rolled steel constructed. Pre-painted cabinet finish. Foil faced fiberglass insulation on hot water coil access door panel, side panels and on back panel reduces cabinet temperatures. lack mat faced fiberglass in blower compartment assures quiet operation. Complete service access by removing hot water coil section and blower compartment access panels. lower assembly completely removable for easy servicing. lower deck rails angle down for easy blower removal. Electrical inlets in both sides of the cabinet. Safety interlock switch automatically shuts off power to unit when blower compartment access door is removed. Return air entry on either side or bottom of cabinet. CWMV is applicable to upflow, horizontal, or downflow installations. Field Make-up ox Furnished for line voltage wiring. ox may be installed on either side of CWMV cabinet. Cabinet - continued Optional ccessories Horizontal Support Frame Kit Provides support of unit in horizontal applications. Consists of () x -/ x 3-5/8 in. and () x 3 x 53-7/8 in. painted heavy gauge cold rolled steel support channels with assembly and suspending holes. olts and nuts furnished for field assembly. Suspending rods must be field provided. R Return ir ase C and D width bases required with 60C models with air volumes over 800 cfm in up-flow applications when only one side return is used. width base is not required but may also be used to provide clearance in certain applications (if required). Cabinet is pre-painted steel to match the furnace. See Dimension Drawing. D ir Filter and Rack Kit for Upflow Side Return ir pplications - Not for use with R Return ir ase Washable or vacuum cleanable polyurethane frame type filter and external side return air rack available for field installation. vailable in single and ten pack kits. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. Field installs on either side of unit cabinet. See dimension drawing. EZ Filter ase for Upflow ottom Return ir pplications Hinged door with thumbscrew for easy filter access. Uses standard size filters (field provided). LOWER Variable Speed lower Motor Variable speed motor (VSM) maintains specified air volume from 0 though 0.80 in. w.g. static range. Gradual acceleration and deceleration of variable speed blower motor when starting and stopping over a specific time frame results in extremely quiet operation. Variable speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Motor is controlled by Electronic lower Control. Motor is resiliently mounted. When units are used with Harmony III Zoning System, blower motor operates from predetermined minimum to maximum air volumes to satisfy zone requirements. Variable Speed lower Each blower assembly statically and dynamically balanced. Change in blower speed is easily accomplished by simple jumper pin position change on Electronic lower Control. lower assembly completely removable for easy servicing. See blower performance tables. ir Filter and Rack Kit for Horizontal Return ir (End) pplications Washable or vacuum cleanable polyurethane frame type filter and external end return air rack available for field installation. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. See dimension drawing. CWMV / Page 3

E FETURES CONTROLS Electronic lower Control Interfaces variable speed motor with thermostat. Controls evaporator humidity by controlling blower and compressor speed on two-stage outdoor units. Two COOL speeds and one HET speed (with four different air volume selections for each) are made by simple jumper pins on board. DJUST jumper pin allows approximately 0% higher, normal, or 0% lower motor speed selection within HET and COOL speeds selected for fine tuning the air volume. DELY jumper pin allows selection blower motor dehumidification profiles during cooling mode. Option - Motor runs at 00% of capacity until demand met. Once demand is met, motor ramps down to stop. Option - Motor runs at 00% of capacity until demand is satisfied. Motor runs at 00% of capacity for 60 seconds then ramps down to stop. Option 3 - Motor runs at 8% of capacity for approximately 7-/ minutes. If demand is not satisfied, motor runs at 00% capacity until demand is satisfied. Once demand is met, motor ramps down to stop. Option 4 - Motor runs at 50% capacity for 30 seconds, then 8% capacity for approximately 7-/ minutes. If demand is not satisfied, motor runs at 00% capacity until demand is met. Once demand is met, motor runs at 50% capacity for 30 seconds, then ramps down to stop. Control has two diagnostic indicator lights, CFM and RUN, to assist in servicing. ccessory relay terminals provide connections for power humidifiers or electronic air cleaners. Control is factory installed in the unit control box. 4 Volt Transformer Furnished in CWMV control box. Optional ccessories ComfortSense 7500 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/ Cool. uto-changeover. Dual-fuel control with optional outdoor sensor. Controls dehumidification during cooling mode and humidification during heating mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. See the ComfortSense 7500 Product Specifications bulletin in the Controls section for more information. Remote Outdoor Temperature Sensor for ComfortSense 7500 Thermostat llows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol applications. Thermostat Thermostat is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price ook for selection. CWMV / Page 4

SPECIFICTIONS Heating Performance Indoor lower Heating Coil Model No. CWMV -4-040 CWMV -36-070 CWMV -36C-090 CWMV -60C-00 CWMV -60C-0 Nominal heating capacity - tuh 40,000 70,000 90,000 00,000 0,000 Temperature rise range - F 3-0 45-5 5-5 4-3 45-5 Wheel nominal diameter x width - in. 0 x 8 0 x 8 0 x 8 -/ x 0 -/ x 0 lower motor output - hp / / / Tons of add-on cooling - 3-3 - 3 3.5-5 3.5-5 Heating capacity range - tuh 3,700-84,700 30,300-3,800 3,400-38,400 49,600-8,700 55,000-0,000 Net face area - sq. ft. 3.83 3.83 4.33 4.33 4.33 Tube diameter & no. of rows - in. 3/8-3/8-3/8-3/8-3/8-3 Fins per inch 6 6 6 6 6 Required pump flow rate for coil capacity rating - GPM 6 6 9.5 9.5 9.5 Water Line Connections (sweat) - in. I.D. Inlet 3/4 3/4 Outlet 3/4 3/4 Shipping Data lbs.- package 7 44 57 57 65 ELECTRICL DT Electrical characteristics 0 volts - 60 hertz - phase Maximum Overcurrent Protection 5 5 5 0 0 Minimum Circuit mpacity 0. 0. 0.4 6.8 6.8 OPTIONL CCESSORIES (ORDER SEPRTELY) 3 ir Filter & Rack Kit Circulating Pump Horizontal (end) - in. 87L96 8 x 5 x 87L97 0 x 5 x in. Side Return - in. Single 44J or Ten Pack (66K63) - () 6 x 5 x Catalog Number 99K69 99K69 53J76 53J76 53J76 Motor output - hp /40 /40 /5 /5 /5 Capacity - U.S. GPM 0-0 0-0 0-4 0-4 0-4 Pressure drop thru coil @ rated flow - psi 3 3 3 3 3 ComfortSense 7500 Thermostat 3H4 3H4 3H4 3H4 3H4 Outdoor Temperature Sensor - for ComfortSense 7500 X658 X658 X658 X658 X658 EZ Filter ase Catalog Number 73P56 73P57 Dimensions - H x W x D - in. 4 x 7-5/8 x 8-5/8 4 x -5/8 x 8-5/8 Size of field provided filter - in. 6 x 5 x 0 x 5 x Horizontal Support Frame Kit 56J8 56J8 56J8 56J8 56J8 R Return ir ase 98M60 98M58 Minimum temperature rise is based off 40 F entering water temperature and the maximum heating air volume. Maximum temperature rise is based off 00 F entering water temperature and the minimum heating air volume using the Harmony III Zoning System. HCR type breaker or fuse. 3 Cleanable polyurethane frame type filter. FIELD WIRING DISCONNECT SWITCH (by other) OPTIONL THERMOSTT CWMV UNIT Two wire power with ground Three wire control voltage (Heating Only) Four wire control voltage (Cooling) Five wire control voltage ( Stage Cooling) Field wiring not furnished ll wiring must conform to NEC or CEC and local electrical codes. INSTLLTION CLERNCES CWMV Upflow / Downflow CWMV Horizontal Sides 0 inches (0 mm) 0 inches (0 mm) Rear 0 inches (0 mm) 0 inches (0 mm) Top 0 inches (0 mm) 0 inches (0 mm) Front 0 inches (0 mm) 0 inches (0 mm) Floor Combustible 0 inches (0 mm) NOTE - Termination location must conform to the methods outlined in merican National Standard (NSI-Z3.) National Fuel Gas Code or National Sta dard of Canada CN/CG-49., and CN/CG-49. Installation Code for Gas urning ppliances. Line contact installation permissible between jacket top or sides and builing joists Front clearance for alcove installations is 30 in. CWMV / Page 5

DIMENSIONS - INCHES (MM) NOTE - Single side inlet applications result in approximately 4% reduction of air volume on -size units and approximately 5% reduction of air volume on C-size units. G WTER INLET Optional External Side Return ir Filter Kit is not for use with the optional R Return ir ase. F E SUPPLY IR OPENING WTER OUTLET D OPTIONL EXTERNL SIDE RETURN IR FILTER KIT (Either Side) 3-3/4 (603) 5 (635) TOP VIEW 9/6 (4) LTERNTE WTER INLET (Left Side Only) -/4 (3) 8-/ (74) 9-7/6 (494) 9/6 (4) OPTIONL EXTERNL SIDE RETURN IR FILTER KIT (Either Side) 40 (06) LTERNTE WTER OUTLET (Right Side Only) -3/4 (44) (5) 0-/ (67) ELECTRICL INLET (Either Side) 4-3/4 (375) 6 (406) 4 (0) 3 (584) OPTIONL RETURN CUTOUT (Either Side) 4 (356) IR FLOW -5/6 (49) 3/4 (9) C 3/4 (9) ottom Return ir Opening FRONT VIEW 5/8 (6) 4-/4 (08) 3-/ (597) ottom Return ir Opening SIDE VIEW Model No. CWMV-4-040 CWMV-36-070 CWMV-36C-090 CWMV-60C-00 CWMV-60C-30 C D E F G in. mm in. mm in. mm in. mm in. mm in. mm in. mm 7-/ 446 6-3/8 46 6 406 -/ 38-3/4 44 8 03 5 533 9-7/8 454 9-/ 495 5 -/ 64 9-/ 4 -/ 38 CWMV / Page 6

OPTIONL CCESSORY DIMENSIONS - INCHES (MM) HORIZONTL FILTER KIT 4 3/4 (69) 5/8 (6) -/4 (3) 5/8 (6) RETURN IR OPENING IR FLOW 5/8 (6) 5/8 (6) 3 / (597) SIDE VIEW IR FILTER (Furnished) FRONT VIEW Catalog Number inch mm inch mm 87L96 8 457 6-3/4 45 87L97 533 8-3/4 476 R RETURN IR SE (Upflow pplications Only) IR FLOW 7-/4 (84) IR HNDLER FRONT 4 (356) 4 (0) 3 (584) Overall (Maximum) Unit side return air Opening 5-5/8 (43) SIDE RETURN IR OPENINGS (Either Side) Minimum (79) Maximum 4 (356) -7-6 (570) Overall (Maximum) 7-/ (446) R- (98M60) (533) R-C (98M58) FRONT VIEW OPTIONL R RETURN IR SE 7/8 () 3 (584) 7-5/8 (70) SIDE VIEW NOTE- Optional Side Return ir Filter Kits are not for use with R Return ir ase. oth the unit return air opening and the base return air opening must be covered by a single plenum or IQ cabinet. Minimum unit side return air opening dimensions for units requiring 800 cfm or more of air (W x H): 3 x in. (584 x 79 mm). The opening can be cut as needed to accommodate plenum or IQ cabinet while maintaining dimensions shown. Side return air openings must be cut in the field. There are cutting guides stenciled on the cabinet for the side return air opening. The size of the opening must not extend beyond the markings on the furnace cabinet. To minimize pressure drop, the largest opening height possible (up to 4 inches) is preferred. NOTE- Optional Side Return ir Filter Kits are not for use with R Return ir ase. 3/4 (9) CWMV / Page 7

DIMENSIONS - INCHES (MM) - FURNCE/COIL COMINED COMINTIONS UPFLOW POSITION UPFLOW POSITION 40 (06) DOWNFLOW POSITION CWMV Width 40 (06) Model No CX34-8/4-6F C33-4 CX34-8/4C-6FC33-4C Cased Uncased (CX34 - cased only) in. mm in. mm in. mm in. mm 6-/ 49 56-/ 435 3-7/8 35 53-7/8 368 CX34-5-6F C33-5 9-/ 495 59-/ 5 5-7/8 403 55-7/8 49 CX34-30-6F CX34-30C-6F C33-30 C33-30C 0-/ 5 60-/ 537 7-3/4 45 59-3/4 467 CX34-3-6F C33-3 3-/ 597 63-/ 63 0-/4 54 60-/4 530 CX34-36-6F C33-36 4-/ 6 64-/ 638-7/8 556 6-7/8 57 CX34-36C-6F C33-36C 4-/ 6 64-/ 638 -/4 540 6-/4 556 CX34-38-6F C33-38 4-/ 6 64-/ 638 559 6 575 CX34-4-6F C33-4 4-/ 6 64-/ 638-7/8 556 6-7/8 57 CX34-43-6F C33-43 8-/ 74 68-/ 740 6-/4 667 66-/4 683 CX34-43C-6F C33-43C 8-/ 74 68-/ 740 5-3/4 654 65-3/4 670 C33-44C 4-/ 6 64-/ 638 -/ 546 6-/ 56 CX34-44/48-6FC33-48 4-/ 6 64-/ 638 -/8 56 6-/8 578 CX34-44/48C-6FC33-48C 4-/ 6 64-/ 638 -/ 546 6-/ 56 CX34-49C-6F C33-49C 9-/ 749 70-/ 79 8-/ 74 68-/ 740 CX34-50/60C-6FC33-50/60C7-/ 699 67-/ 75 4-3/4 69 64-3/4 645 CX34-6C-6F C33-6C 3-/ 86 7-/ 84 30-5/8 778 70-5/8 793 Coil Width HORIZONTL 40 (06) Coil Height Overall Height NOTE Downflow applications with add on cooling coil require field fabricated transitions to provide adequate clearance for servicing/removing the cooling coil without cutting the water lines. See Installation Instructions. DOWNFLOW POSITION Model Number Coil Width Furnace Width Coil Height Overall Height in. mm in. mm in. mm in. mm CR33-4-F 7-/ 446 7-/ 446 3-/4 337 53-/4 353 CR33-30/36-F 7-/ 446 7-/ 446 6-/8 40 56-/8 46 CR33-30/36C-F 533 533 6-/8 40 56-/8 46 CR33-48-F 533 7-/ 446 0 508 60 54 CR33-48C-F 533 533 0 508 60 54 CR33-50/60C-F 4-/ 6 533 3-5/8 600 53-5/8 36 HORIZONTL POSITION Model Number CH33-5-F CH33-3-F CH33-36-F CH33-36C-F CH33-4-F CH33-43C-F CH33-48C-F CH33-43-F CH33-44/48-F CH33-49C-F CH33-50/60C-F in. mm in. mm 6-/ 673 66-/ 689 3-/ 800 7-/ 86 CWMV / Page 8

LOWER DT CWMV-4-040 lower Performance 0 through 0.80 in. w.g. External Static Pressure Range DJUST Jumper Setting lower Control Jumper Speed Positions HET Speed - cfm First Stage COOL Speed - cfm Second Stage COOL Speed - cfm 3 4 3 4 3 4 + 80 990 80 340 60 770 930 00 880 0 340 440 NORM 750 900 070 30 560 700 830 90 800 000 00 300 670 80 940 080 50 630 750 80 70 900 080 70 CWMV-36-070 lower Performance 0 through 0.80 in. w.g. External Static Pressure Range DJUST Jumper Setting lower Control Jumper Speed Positions HET Speed - cfm First Stage COOL Speed - cfm Second Stage COOL Speed - cfm 3 4 3 4 3 4 + 790 980 40 30 590 745 895 975 850 090 300 430 NORM 730 870 040 90 545 680 805 890 775 990 90 80 640 770 90 070 490 600 75 780 700 870 065 50 CWMV-36C-090 lower Performance 0 through 0.80 in. w.g. External Static Pressure Range DJUST Jumper Setting lower Control Jumper Speed Positions HET Speed - cfm First Stage COOL Speed - cfm Second Stage COOL Speed - cfm 3 4 3 4 3 4 + 80 000 80 340 60 770 930 00 890 30 340 450 NORM 760 900 070 0 570 700 830 90 800 00 0 30 675 80 950 00 50 630 760 80 70 900 00 80 CWMV-60C-00 lower Performance 0 through 0.80 in. w.g. External Static Pressure Range DJUST Jumper Setting lower Control Jumper Speed Positions HET Speed - cfm First Stage COOL Speed - cfm Second Stage COOL Speed - cfm 3 4 3 4 3 4 + 500 700 880 00 0 50 380 530 540 760 970 00 NORM 370 540 70 90 000 30 50 380 400 600 800 980 50 380 540 70 930 040 30 60 70 40 600 780 CWMV-60C-0 lower Performance 0 through 0.80 in. w.g. External Static Pressure Range DJUST Jumper Setting lower Control Jumper Speed Positions HET Speed - cfm First Stage COOL Speed - cfm Second Stage COOL Speed - cfm 3 4 3 4 3 4 + 50 70 900 0 00 50 400 560 570 800 000 00 NORM 380 560 740 90 990 30 60 400 40 60 80 00 40 380 540 70 930 00 30 60 60 440 60 80 Factory default jumper setting. NOTES - The effect of static pressure and filter resistance is included in air volumes shown. First stage COOL is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position. Harmony III Zoning System applications - Minimum blower speed: 50 cfm for -4-40, -36-070, -36C-090. 450 cfm for -60C-00. 380 cfm for 60C-0. Maximum air volume is the same as second stage cool position. pplications with single sided inlets will reduce the air volume by approximately 4% on -size units and 5% on C-size units. CWMV / Page 9

HETING PERFORMNCE CWMV-4-040 HETING OUTPUTS NOTE - Capacities in shaded area require Harmony III Zoning System to reach the air volumes listed ir Volume (cfm) CWMV / Page 0 Heating Outputs t Various Water Temperatures (tuh) 40 F 50 F 60 F 70 F 80 F 90 F 00 F 400 3,700 6,900 30,00 33,500 36,700 39,900 43,00 500 7,400 3,00 34,800 38,800 4,500 46,00 49,900 600 30,700 34,800 38,900 43,500 47,600 5,700 55,900 700 33,600 38,00 4,600 47,600 5,00 56,700 6,00 800 36,00 4,000 45,900 5,400 56,300 6,00 66,000 900 38,500 43,700 48,800 54,800 60,000 65,00 70,400 000 40,700 46,00 5,600 57,900 63,400 68,900 74,400 00 4,700 48,400 54,00 60,700 66,500 7,300 78,00 00 44,500 50,400 56,400 63,400 69,400 75,500 8,500 300 46,00 5,400 58,500 65,900 7,00 78,400 84,700 CWMV-36-070 HETING OUTPUTS NOTE - Capacities in shaded area require Harmony III Zoning System to reach the air volumes listed ir Volume (cfm) Heating Outputs t Various Water Temperatures (tuh) 40 F 50 F 60 F 70 F 80 F 90 F 00 F 400 30,300 34,400 38,500 4,700 46,800 50,900 54,900 500 36,00 4,00 45,900 5,00 56,000 60,900 65,700 600 4,500 47,00 5,600 58,700 64,300 69,900 75,500 700 46,300 5,500 58,700 65,600 7,800 78,00 84,300 800 50,700 57,400 64,00 7,800 78,700 85,500 9,400 900 54,600 6,900 69,00 77,600 85,000 9,300 99,700 000 58,00 66,000 73,700 8,800 90,700 98,600 06,500 00 6,500 69,700 78,000 87,600 96,000 04,300,700 00 64,600 73,00 8,800 9,00 00,900 09,700 8,500 300 67,400 76,400 85,400 96,300 05,500 4,600 3,800 CWMV-36C-090 HETING OUTPUTS NOTE - Capacities in shaded area require Harmony III Zoning System to reach the air volumes listed ir Volume (cfm) Heating Outputs t Various Water Temperatures (tuh) 40 F 50 F 60 F 70 F 80 F 90 F 00 F 400 3,400 35,600 39,800 44,00 48,400 5,600 56,800 500 38,000 43,000 48,00 53,400 58,500 63,600 68,700 600 44,000 49,900 55,800 6,000 67,900 73,800 79,700 700 49,600 56,00 6,900 69,900 76,600 83,300 90,000 800 54,800 6,00 69,400 77,300 84,700 9,00 99,400 900 59,600 67,500 75,500 84,00 9,00 00,00 08,300 000 64,00 7,600 8,00 90,600 99,300 07,900 6,500 00 68,300 77,400 86,500 96,700 05,900 5,00 4,300 00 7,00 8,800 9,400 0,300,000,800 3,500 300 75,900 86,000 96,00 07,600 7,900 8,00 38,400 CORRECTION FCTOR FOR DIFFERENT INLET IR TEMPERTURES 60 F dd 6% 65 F No Change 70 F Minus 6% 75 F Minus %

HETING PERFORMNCE CWMV-60C-00 HETING OUTPUTS NOTE - Capacities in shaded area require Harmony III Zoning System to reach the air volumes listed ir Volume (cfm) Heating Outputs t Various Water Temperatures (tuh) 40 F 50 F 60 F 70 F 80 F 90 F 00 F 700 49,600 56,00 6,900 69,900 76,600 83,300 90,000 800 54,800 6,00 69,400 77,300 84,700 9,00 99,400 900 59,600 67,500 75,500 84,00 9,00 00,00 08,300 000 64,00 7,600 8,00 90,600 99,300 07,900 6,500 00 68,300 77,400 86,500 96,700 05,900 5,00 4,300 00 7,00 8,800 9,400 0,300,000,800 3,500 300 75,900 86,000 96,00 07,600 7,900 8,00 38,400 400 79,300 89,900 00,500,600 3,400 34,00 44,800 500 8,600 93,600 04,600 7,400 8,600 39,800 50,900 550 84,00 95,400 06,600 9,700 3,00 4,500 53,900 700 88,600 00,400,300 6,00 38,00 50,00 6,00 900 94,000 06,600 9,00 34,00 46,900 59,600 7,400 00 99,000,00 5,400 4,300 54,800 68,00 8,700 CWMV-60C-0 HETING OUTPUTS NOTE - Capacities in shaded area require Harmony III Zoning System to reach the air volumes listed ir Volume (cfm) Heating Outputs t Various Water Temperatures (tuh) 40 F 50 F 60 F 70 F 80 F 90 F 00 F 700 55,000 6,400 69,700 77,400 84,800 9,00 99,600 800 6,600 69,800 78,000 86,700 95,000 03,00,500 900 67,700 76,700 85,800 95,500 04,600 3,700,700 000 73,500 83,300 93,00 03,800 3,700 3,500 33,400 00 79,000 89,500 00,00,600,300 3,900 43,500 00 84,00 95,400 06,600 9,00 30,400 4,700 53,00 300 89,000 00,900,800 6,00 38,00 50,00 6,00 400 93,600 06,00 8,600 3,800 45,400 58,00 70,700 500 98,000,00 4,00 39,00 5,400 65,600 78,900 550 00,00 3,500 6,800 4,00 55,700 69,300 8,800 700 06,00 0,00 34,400 50,900 65,300 79,700 94,000 900 3,400 8,500 43,600 6,600 77,000 9,400 07,800 00 0,000 36,000 5,000 7,300 87,600 03,900 0,300 CORRECTION FCTOR FOR DIFFERENT INLET IR TEMPERTURES 60 F dd 6% 65 F No Change 70 F Minus 6% 75 F Minus % CWMV / Page

REVISIONS Sections Optional ccessories Description of Change dded new ComfortSense 7500 thermostat. Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 05 Lennox Industries, Inc.