ommercial Thermostat Submittal Data English anguage/i-p Units SUBMITTA DATA Unit Designation: Job Name: Architect: Engineer: ontractor: ev.: 02/23/06D limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com. *204* 204 ev.: 02/23/06D
3.00 in [76mm] ATM1101 ne Heat / ne ool Manual hangeover Non-Programmable increase & decrease The ATM1101 thermostat provides single-stage, nonprogrammable temperature control for 24V water-source heat pump systems. 4.70 in [119mm] : turns FF or N olor: White Integral switches control system and fan mode. Vented cover for improved temperature sensing. Mount directly on wall or vertical outlet box using mounting plate. Electronic sensing (no mercury bulb or bi-metal switching). Electrical ating: Voltage 20 to 30 VA Heating: 0.18 to 1.0A at 30VA maximum. ooling: 1.5A running, 7.5A inrush at 25 VA. Settings: Scale ange: 50 F to 90 F (10 to 32 ). 1.25 in Depth (32mm) Mode: Selects system mode - FF, HEAT, or Switching Action: Accurate electronic sensing/switching. 4-wire control of heating/cooling/reversing valve. onnection to XM ontrol ATM1101 Thermostat XM ompressor eversing Valve W onnection to ontrol ATM1101 Thermostat ompressor eversing Valve W /W2 limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com. 204 ev.: 02/23/06D
4.6 in [116.8mm] Mode: Selects system mode - FF, HEAT, or ATM1103 ne Heat / ne ool Manual hangeover Non-Programmable With emote Sensor & Two-Speed ontrol Two-Speed 2.7 in [68.6mm] Fault ight Electrical ating: Input Power: 18 to 30 Vac, 50/60 Hz. Settings: Setpoint ange: 50 F to 90 F [10 to 32 ]. The default setpoint for heating is 70 F [21 ] and for cooling is 74 F [23 ]. Press the or keys to change the setting. To change between heat and cool settings, press the mode key until the setting to be changed appears. decrease 1.1 in Depth (27.9mm) increase : turns FF or N Display ange: Display Updates: Updated every 12 seconds. Differential (autochangeover model): 3 F [1.5 ] minimum. utput atings: Maximum current for each output is 1 Amp. 4.9in [124.5mm] onnection to XM ontrol 1.5in [38.1mm] ATM1103 Thermostat ompressor XM 3.1in [78.7mm] 3.9in [99.1mm] eversing Valve 1 Note 1 2.4in [60.9mm] 24Vac ommon Fault ED S1 Note 2 S2 emote Sensor The ATM1103 electronic thermostat provides single-stage, non-programmable temperature control for 24V water-source heat pump systems. emote sensor is included. Heat-ff-ool System selections. -n-auto selections. High / ow fan speed switch. emote temperature sensor included. F or temperature display. ight emitting diode (ED) for alarm status. Installer setup options allow for customized applications. Setpoints are permanently held in memory (no batteries used) and retained during power outages. Wall mounting plate. onnection to ontrol ATM1103 Thermostat ompressor Hi Speed eversing Valve o Speed 24Vac ommon Fault ED 2 1 S1 S2 Note 1 Note 2 emote Sensor H /W2 Note 1: Two speed fan selection switch is only operable with board and units with PS fan motor. board must be configured (DIP 2.7 in "FF" position) for high speed fan. This feature is typically used for console and vertical stack units. This thermostat will work with the XM board, but the two-speed feature will not control the fan. Note 2: emote sensor is shipped with thermostat. When remote sensor is not used, internal jumper must be reinstalled. limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com. 204 ev.: 02/23/06D
4.55 in [115.6mm] ATA11U01 ne Heat / ne ool Auto / Manual hangeover Non-Programmable 3.30 in [83.8mm] : turns FF or N Fault ight increase Extended fan operation feature can be used to operate fan for 90 seconds after turns off. Setup feature allows either current room temp or the current setpoint to be displayed. ptional safety setpoints ensure that heating and cooling will occur even if thermostat is in ff mode. Backplate wiring for easy installation. decrease Electrical ating: Input Power: 18 to 30 Vac, 50/60 Hz. 0.8 in Depth (20.3mm) Mode: Selects system mode - FF, HEAT,, or AUT 1.587in (40.3mm) 2.375in (60.3mm) Settings: Setpoint ange: 50 F to 90 F [10 to 32 ]. The default setpoint for heating is 70 F [21 ] and for cooling is 74 F [23 ]. Press the or keys to change the setting. To change between heat and cool settings, press the mode key until the setting to be changed appears. Display ange: Display Updates: Updated every 12 seconds. Differential (autochangeover model): 3 F [1.5 ] minimum. UP utput atings: Maximum current for each output is 1 Amp. The ATA11U01 electronic thermostat provides single-stage, non-programmable temperature control for 24V water-source heat pump systems. 2.625in (66.7mm) 3.275in (83.2mm) Heat-ff-ool-Auto System selections. -n-auto selections. F or temperature display. onfi gurable automatic or manual changeover operation. ight emitting diode (ED) for alarm status. Installer setup options allow for customized applications. display adjustment feature provides display offset for custom applications. Setpoints are permanently held in memory (no batteries used) and retained during power outages. onnection to XM ontrol ATA11U01 Thermostat ompressor eversing Valve 24Vac ommon Fault ED onnection to ontrol ATA11U01 Thermostat ompressor eversing Valve 24Vac ommon Fault ED XM /W2 limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com. 204 ev.: 02/23/06D
4.6 in [116.8mm] Mode: Selects system mode - FF, HEAT,, or AUT Two-Speed ATA1104 ne Heat / ne ool Auto / Manual hangeover Non-Programmable With emote Sensor & Two-Speed ontrol Wall mounting plate. 2.7 in [68.6mm] decrease 1.1 in Depth (27.9mm) Fault ight increase : turns FF or N Electrical ating: Input Power: 18 to 30 Vac, 50/60 Hz. Settings: Setpoint ange: 50 F to 90 F [10 to 32 ]. The default setpoint for heating is 70 F [21 ] and for cooling is 74 F [23 ]. Press the or keys to change the setting. To change between heat and cool settings, press the mode key until the setting to be changed appears. Display ange: Display Updates: Updated every 12 seconds. Differential (autochangeover model): 3 F [1.5 ] minimum. 4.9in [124.5mm] utput atings: Maximum current for each output is 1 Amp. 1.5in [38.1mm] onnection to XM ontrol 3.1in [78.7mm] The ATA1104 electronic thermostat provides single-stage, non-programmable temperature control for 24V water-source heat pump systems. emote sensor is included. 3.9in [99.1mm] 2.4in [60.9mm] Heat-ff-ool-Auto System selections. -n-auto selections. High / ow fan speed switch. emote temperature sensor included. F or temperature display. onfi gurable automatic or manual changeover operation. ight emitting diode (ED) for alarm status. Installer setup options allow for customized applications. Setpoints are permanently held in memory (no batteries used) and retained during power outages. ATM1104 Thermostat ompressor eversing Valve 24Vac ommon Fault ED 1 S1 S2 XM onnection to ontrol ATM1104 Thermostat ompressor Hi Speed eversing Valve o Speed 24Vac ommon Fault ED 2 1 S1 S2 Note 1 Note 2 emote Sensor Note 1 Note 2 emote Sensor H /W2 Note 1: Two speed fan selection switch is only operable with board and units with PS fan motor. board must be configured (DIP 2.7 in "FF" position) for high speed fan. This feature is typically used for console and vertical stack units. This thermostat will work with the XM board, but the two-speed feature will not control the fan. Note 2: emote sensor is shipped with thermostat. When remote sensor is not used, internal jumper must be reinstalled. limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com. 204 ev.: 02/23/06D
4.55 in [115.6mm] ATA22U01 Two Heat / Two ool Auto / Manual hangeover Non-Programmable 3.30 in [83.8mm] : turns FF or N 0.8 in Depth [20.3mm] Fault ight increase decrease Mode: Selects system mode - FF, HEAT,, EMHEAT, or AUT Extended fan operation feature can be used to operate fan for 90 seconds after turns off. Setup feature allows either current room temp or the current setpoint to be displayed. ptional safety setpoints ensure that heating and cooling will occur even if thermostat is in ff mode. Backplate wiring for easy installation. Automatic fan staging (when used with board and direct drive motor). Electrical ating: Input Power: 18 to 30 Vac, 50/60 Hz. Settings: Setpoint ange: 50 F to 90 F [10 to 32 ]. The default setpoint for heating is 70 F [21 ] and for cooling is 74 F [23 ]. Press the or keys to change the setting. To change between heat and cool settings, press the mode key until the setting to be changed appears. 1.587in (40.3mm) 2.375in (60.3mm) Display ange: Display Updates: Updated every 12 seconds. Differential (autochangeover model): 3 F [1.5 ] minimum. UP utput atings: Maximum current for each output is 1 Amp. onnection to XM ontrol The ATA22U01 electronic thermostat provides two-stage, nonprogrammable temperature control for 24V water-source heat pump systems. 2.625in (66.7mm) 3.275in (83.2mm) Heat-ff-ool-Em Heat-Auto System selections. -n-auto selections. F or temperature display. onfi gurable automatic or manual changeover operation. ight emitting diode (ED) for alarm status. Installer setup options allow for customized applications. display adjustment feature provides display offset for custom applications. Setpoints are permanently held in memory (no batteries used) and retained during power outages. ATA22U01 Thermostat ompressor Heating Stage 2 eversing Valve 24Vac ommon Fault ED 2/W Note 1 XM W onnection to ontrol ATA22U01 Thermostat ompressor ompressor Stage 2 or Heating Stage 2 eversing Valve 24Vac ommon Fault ED 2/W Note 2 2 W1 /W2 Note 1: ptional onnection for Heating Stage 2 operation, Thermostat "2" option must be configured as "2 - ff". Note 2: onnect "W/2" thermostat output to "2" on the if thermostat "2" option is configured as "2 - n" and the desired operation is for 2 stages of compressor with no electric heat. onnect "W/2" thermostat output to "W1" on the if thermostat "2" option is configured as "2 - ff" and the desired operation is for 1 stage of compressor with electric heat for Heating Stage 2. limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com. 204 ev.: 02/23/06D
4.9 in [124.5mm] ATP11N01 ne Heat / ne ool Manual hangeover Programmable 4.9 in [124.5mm] Mode: Selects system mode - FF, HEAT, or : turns FF or N increase Individual heat and cool set points. Accurate digital performance. Manual changeover operation. onvenient override allows temporary set point change. Set points are permanently held in memory (no batteries used) and retained during power outages. Backlit D display. 0.8 in Depth [20.3mm] Backlight decrease Programming Keys Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz. Settings: Set point range: 45ºF to 90ºF [7º to 32º]. The default (Energy Star) set point ranges are as follows: 6:00 AM 78ºF cool / 68ºF heat 8:00 AM 85ºF cool / 60ºF heat 5:00 PM 78ºF cool / 68ºF heat 10:00 PM 82ºF cool / 60ºF heat Press the or keys to change the temperature setting. The SEET and SET keys allow changes to the program and schedule. TP utput atings: Maximum current for each output is 1 Amp (3 Amp total max.). onnection to XM ontrol* ATP11U01 Thermostat XM ompressor 3.30" [83.8mm] eversing Valve 1.60" [40.6mm] 24Vac ommon The ATP11N01 Thermostat provides 1 stage heating, 1 stage cooling, and programmable temperature control of 24V watersource heat pump equipment. Programming schedule includes one schedule for the fi ve week days, one schedule for the two weekend days and four periods per day (5/2/4). 5-day/2-day programming. Four periods per day. ºF or º temperature display. onnection to ontrol* ATP11U01 Thermostat ompressor eversing Valve 24Vac ommon *Note: Make sure the HP switch is in the HP postion. When switched to HP mode, W1 is connected internally to. /W2 limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com. 204 ev.: 02/23/06D
3.30 in [83.8mm] Thermostat Submittal Data Eng/I-P 0.8 in Depth [20.3mm] 4.55 in [115.6mm] Programming Keys 1.20" [30.5mm] UP : turns FF or N increase decrease Mode: Selects system mode - FF, HEAT,, EMHEAT, or AUT 2.35" [59.7mm] ATP21U01 Two Heat / ne ool Auto / Manual hangeover Programmable Automatic (program mode) or manual changeover. onvenient overrides allow temporary set point changes. Set points are permanently held in memory (no batteries used) and retained during power outages. oom temperature offset adjustment. Back-plate wiring connections for easy installation. Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz Settings: Set point range: 50ºF to 90ºF [10º to 32º] The default (Energy Star) set point ranges are as follows: 6:00 AM 78ºF cool / 68ºF heat 8:00 AM 85ºF cool / 60ºF heat 5:00 PM 78ºF cool / 68ºF heat 10:00 PM 82ºF cool / 60ºF heat Press the or keys to change the temperature setting. The MDE, PAM and HD keys allow changes to the program and schedule. utput atings: Maximum current for each output is 1 Amp. onnection to XM ontrol ATP21U01 Thermostat XM ompressor 0.65" [16.5mm] eversing Valve 24Vac ommon The ATP21U01 Thermostat provides 2 stages heating, 1 stage cooling, and programmable temperature control of 24V watersource heat pump equipment. Programming schedule includes one schedule for the fi ve week days, one schedule for the two weekend days and four periods per day (5/2/4). 3.30" [83.8mm] 5-day/2-day programming. Four periods per day. ºF or º temperature display. Individual heat and cool set points. onnection to ontrol ATP21U01 Thermostat ompressor eversing Valve 24Vac ommon /W2 limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com. 204 ev.: 02/23/06D
6.25 in [158.8mm] ATP32U01 Three Heat / Two ool Auto / Manual hangeover Programmable (7 Day) 4.25 in [108.0mm] 1.1 in Depth [27.9mm] UP 0.72" [18.3mm] Set points are permanently held in memory (no batteries used) and retained during power outages. oom temperature offset adjustment. Progressive ecovery anticipates the time required to bring the space temperature to the next programmed event, and brings on the heat pump accordingly. arge backlit dot matrix display is activated whenever a key is pressed and remains on for 25 seconds. Menu-driven programming with fi ve navigation buttons (UP/ DWN/EFT/IHT/SEET) for ease of use. Fault indication with red backlight display. onfi gurable service interval messages and servicing contractor contact information. Keypad lockout. Back-plate wiring connections for easy installation. Exclusive fault identifi cation (When used with XM or ) displays fault from XM/ board (e.g. condensate overfl ow) and suggests possible causes. ompatible with AST008 sensor for use as remote and/or outdoor sensor. Automatic fan staging (when used with board and direct drive motor). Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz. 2.90" [73.7mm] 6.25" [158.8mm] perating onditions: 32ºF to 104ºF [0º to 40º]. 10% to 95% non-condensing. Settings: Set point range: 40ºF to 90ºF [4º to 32º], +/- 2ºF [1º]. 0.62" [15.7mm] utput atings: Maximum current for each output is 1.0 Amp (2.0 max. output total). The ATP32U01 Thermostat provides 3 stages heating, 2 stages of cooling, and programmable temperature control of 24V water-source heat pump equipment. 7-day programming. Four periods per day. ºF or º temperature display 12 or 24 hour clock. Individual heat and cool set points. Automatic (program mode) or manual (HD) operation. onvenient overrides allow temporary set point changes. limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com. 204 ev.: 02/23/06D
Single Stage Units onnection to XM ontrol ATP32U01 Three Heat / Two ool Auto / Manual hangeover Programmable (7 Day) Units With EM ATP32U01 Thermostat XM onnection to EM ontrol ompressor ATP32U01 Thermostat EM eversing Valve 24Vac ommon Fault ED onnection to ontrol ompressor ompressor Stage 2 eversing Valve 24Vac ommon Fault ED 2 2 ATP32U01 Thermostat Units with XM or board and EM fan motor ompressor 2 Note 1 2 eversing Valve /W2 24Vac ommon Fault ED Single stage unit with PS or belt drive fan motor Two Stage Units ATP32U01 Thermostat ompressor ompressor Stage 2 2 eversing Valve 24Vac ommon Fault ED Two compressor unit with XM boards onnection to XM ontrol XM 1 XM 2 onnection to ontrol ATP32U01 Thermostat ompressor ompressor Stage 2 2 2 eversing Valve 24Vac ommon Fault ED /W2 Two compressor unit with boards limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com. 204 ev.: 02/23/06D
6.25 in [158.8mm] ATP32U02 Three Heat / Two ool Auto / Manual hangeover Programmable (7 Day) With Dehumidifi cation 4.25 in [108.0mm] 1.1 in Depth [27.9mm] UP 0.72" [18.3mm] 2.90" [73.7mm] 6.25" [158.8mm] Thermostat can be programmed to use humidifi cation output to control a humidifi er. Four periods per day. ºF or º temperature display. 12 or 24 hour clock. Individual heat and cool set points. Automatic (program mode) or manual (HD) operation. onvenient overrides allow temporary set point changes. Set points are permanently held in memory (no batteries used) and retained during power outages. oom temperature offset adjustment. Progressive ecovery anticipates the time required to bring the space temperature to the next programmed event, and brings on the heat pump accordingly. arge backlit dot matrix display is activated whenever a key is pressed and remains on for 25 seconds. Menu-driven programming with fi ve navigation buttons (UP/ DWN/EFT/IHT/SEET) for ease of use. Fault indication with red backlight display. onfi gurable service interval messages and servicing contractor contact information. Keypad lockout. Back-plate wiring connections for easy installation. Exclusive fault identifi cation (When used with XM or ) displays fault from XM/ board (e.g. condensate overfl ow) and suggests possible causes. ompatible with AST008 sensor for use as remote and/or outdoor sensor. Automatic fan staging (when used with board and direct drive motor). 0.62" [15.7mm] Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz. The ATP32U02 Thermostat provides 3 stages heating, 2 stages of cooling, and programmable temperature/humidity control of 24V water-source heat pump equipment. 7-day programming. Dehumidifi cation output is designed to work with limadry Modulating eheat option or with EM fan motor dehumidifi cation mode. Integrated control of both temperature and relative humidity. Integrated control eliminates separate thermostat and dehumidistat/humidistat. perating onditions: 32ºF to 104ºF [0º to 40º]. 10% to 95% non-condensing. Settings: Set point range: 40ºF to 90ºF [4º to 32º], +/- 2ºF [1º]. Dehumidifi cation set point range: 15% to 95% H. Humidifi cation set point range: 10% to 45% H. utput atings: Maximum current for each output is 1.0 Amp (2.0 max. output total). limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com. 204 ev.: 02/23/06D
Units with limadry eheat onnection to ontrol ATP32U02 Three Heat / Two ool Auto / Manual hangeover Programmable (7 Day) With Dehumidifi cation Units with EM ATP32U02 Thermostat onnection to EM ontrol ompressor Dehumidification eversing Valve 24Vac ommon Fault ED DH H /W2 ATP32U02 Thermostat ompressor ompressor Stage 2 Dehumidification eversing Valve 2 DH EM 2 DH Single stage unit with limadry Modulating eheat ption and board (PS or belt drive fan motor) 24Vac ommon Fault ED onnection to ontrol ATP32U02 Thermostat ompressor ompressor Stage 2 Dehumidification eversing Valve 24Vac ommon Fault ED 2 DH 2 H /W2 Units with XM or board and EM fan motor, utilizing EM dehumidification mode (w/o limadry option) Notes: 1) EM dehumidification mode slows down fan speed in the cooling mode when dehumidification output from thermostat is active. Normal heating and cooling fan speeds are not affected. 2) EM board DIP switch SW9 must be in dehumid. mode. Units with limadry eheat & EM Two compressor unit with limadry Modulating eheat ption and board onnection to EM & ontrol ATP32U02 Thermostat EM ompressor ompressor Stage 2 2 2 2 Dehumidification DH H eversing Valve /W2 /W2 24Vac ommon Fault ED Single or two-stage unit with limadry Modulating eheat ption and board (EM fan motor) limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact limatemaster's ustomer but are merely limatemaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com. 204 ev.: 02/23/06D