USER S MANUAL UET CONTROL UNIT FOR THE AIR HEATING UNIT WITH ELECTRIC HEATER AOE SERIES

Similar documents
USER S MANUAL. VKP Series INLINE FAN

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

USER S MANUAL DN-2. Drain pump

AXIAL FANS USER S MANUAL

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

Air handling unit. BlauAir RH USER S MANUAL

Centrifugal inline fans

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

AXIAL FANS user's manual. model Quiet

HEAT RECOVERY VENTILATOR

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

Axial intelligent fan USER S MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

AIR HANDLING UNIT WITH HEAT RECOVERY

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

CENTRIFUGAL FANS user's manual. model VENTS VK.

Wind. Service instruction

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SINGLE-ROOM REVERSIBLE ENERGY REGENERATION VENTILATOR

USER S MANUAL SINGLE-ROOM REVERSIBLE ENERGY REGENERATION VENTILATOR. TwinFresh Comfo: RA1-25 RA SA-35 SA-35-2 SA1-35 SA1-35-2

Calm. Service Instructions

INTELLIGENT AXIAL FAN user's manual

Turbo. Service Instructions

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON ECO. PROTON ECO Three-speed AC-motor

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON AST. PROTON AST Air Heater with the anemostat

HEAT RECOVERY AIR HANDLING UNIT

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON JET. PROTON JET Air Heater with with AirJet nozzle.

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

Aero. Service Instructions

USER'S MANUAL PS

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

Operation Manual. Automatic Control System for Air Supply Ventilation Unit with Hydronic Coil Heat Exchanger

Installation manual Mini Comfort 50 S/L 07/ V EN

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

Duct electric heater with temperature controller

Sensor Control Panel

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

Duct electric heater with heating. capacity from 0.6 kw up to 2.4 kw and an integrated. temperature controller

EKA EKA NI EKA NIS EKA NV EKA NV PH EKA NV PTC/PS

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

Obstruction Lighting Controller Manual

OWNERS MANUAL. To Order Parts Call SPEED AIR MOVER

Installation and operating instructions. DK energy storage and DK energy buffer

USE AND INSTALLATION HANDBOOK

Whole Room Dryer WRD, WRD/110

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

Surna 25-Ton Chiller Operating & Maintenance Manual

INSTRUCTION MANUAL (English version) Water still

INSTALLATION AND OPERATION MANUAL

Instructions for the fan motor control system, SILVER C

MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

HEAT RECOVERY AIR HANDLING UNITS

OPERATION AND MONTAGE MANUAL ROOF FANS

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Ceiling Mount Air Purification System

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

AC-12200E Portable Air Conditioner

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

INSTALLATION AND OPERATION MANUAL

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

VC-1, VC-1-SL, VC-2-L, VC-2-SL

TECHNICAL CERTIFICATE USER MANUAL THERMOSTAT TP years warranty

General safety precautions English

SUPER ASTRA PRODUCT MANUAL. PM R20 Issue 3 1/00

Installation Instructions VITOTRONIC 200

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

EKS EKS NI EKS NIS EKS NV EKS NV PH EKS NV PTC/PS

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

FLCH4R Garage and Utility Electric Heater

Transcription:

USER S MAUAL UET COTROL UIT FOR THE AIR HEATIG UIT WITH ELECTRIC HEATER AOE SERIES

2 UET COTETS Safety Requirements 3 Introduction 5 Use 5 Delivery Package 5 Designation Key 5 Technical Data 5 Design and Operating Logic 7 Installation and Setup 7 Connection to power mains 9 Technical Maintenance 14 Troubleshooting 14 Transportation and Storage Rules 14 Manufacturer's Warranty 15 Acceptance Certificate 16 Vendor's Information 16 Installation Certificate 16 Warranty Card 17

www.ventilation-system.com 3 SAFETY REQUIREMETS Read the user s manual carefully prior to the operation and installation of the control unit. Installation and operation of the control unit shall be performed in accordance with the present user s manual as well as the provisions of all the applicable local and national construction, electrical and technical codes and standards. The warnings contained in the present user s manual must be considered most seriously since they contain vital personal safety information. Failure to follow the safety regulations may result in an injury or control unit damage. Read the manual carefully and keep it as long as you use the control unit. While transferring the unit control the user s manual must be turned over to the receiving operator. Symbol legend used in the manual: ATTETIO! RESTRICTED! COTROL UIT ISTALLATIO - SAFETY PRECAUTIOS The control unit must be disconnected from the power supply prior to every installation or repair operation. Ground the control unit! The control unit must not be operated outside the temperature range stated in the user's manual or in aggressive or explosive environments. Do not use damaged equipment or conductors to connect the control unit to power mains. While installing the control unit follow the safety regulations specific to the use of electric tools. Unpack the control unit with care. Do not change the power cord length at your own discretion. Do not bend the power cord. Avoid damaging the power cord. Use the control unit only as intended by the manufacturer.

4 UET COTROL UIT OPERATIO - SAFETY PRECAUTIOS Do not touch the controller or the remote control with wet hands. Do not carry out the control unit maintenance with wet hands. Do not wash the control unit with water. Protect the control unit electric parts from water ingress. Use the control unit only as intended by the manufacturer. Do not connect any cloth dryers or any other equipment to the ventilation system. Do not put any water containers (e.g. vases etc.) on top of the control unit. Do not sit on the control unit or put any foreign objects on top of it. O OFF Disconnect the control unit from the power mains prior to any technical maintenance. Do not let children operate the control unit. Keep the power cord intact while operating the control unit. Do not put any foreign objects on top of the power cord. Keep explosive and inflammable products away of the control unit. Do not open the operating control unit. In case of unusual sounds, smoke disconnect the control unit from power supply and contact the service centre. Do not let air flow from the control unit be directed to the open flame devices or candles.

www.ventilation-system.com 5 ITRODUCTIO The present User s Manual combined with the technical details, the Operation Manual and the Product Certificate contains the information specific to the operation and installation of the VETS AOE series electric warm air heater control unit (UET) (hereinafter «Control Unit»). USE The Control Unit is designed for automatic control of VETS AOE series electric warm air heater operation. THE COTROL UIT IS OT ITEDED FOR OPERATIO BY CHILDRE OR AY PERSOS WITH LIMITED SESORY OR METAL CAPACITY AS WELL PERSOS LACKIG THE REQUIRED TRAIIG. THE COTROL UIT MUST BE HADLED OLY BY PROPERLY QUALIFIED PERSOEL AFTER THE APPROPRIATE SAFETY BRIEFIG. THE CHOICE OF COTROL UIT ISTALLATIO LOCATIO MUST PREVET UAUTHORIZED ACCESS BY UATTEDED CHILDRE. DELIVERY PACKAGE Control Unit - 1 piece. User s Manual - 1 piece. Shipping Box - 1 piece. DESIGATIO KEY UET - Х D Automation Equipment Options E - single-phase D - three-phase Air Heating Unit Power 15 - Up to 15 kw 30 - Up to 30 kw Designation UET - control unit for the electric heater TECHICAL DATA The control unit is designed for operation in an enclosed area at ambient temperatures from 0 C to + 35 C at relative humidity of up to 80% (at +25 C). The units meet the requirements of IP44 hazardous parts access and water ingress protection standard. The units belong to electrical shock hazard protection class I. The main outside and connecting dimensions as well as the appearance and technical parameters of the unit are given on Figure 1 and in Table 1. The control unit undergoes continuous improvement - therefore, some models may slightly differ from the ones described herein.

6 UET Table 1. Technical Data Parameter UET-15D UET-30D AOE Air Heating Unit Compatibility AOE 9 AOE 12 AOE 15 Supply Voltage, 50 Hz [V] 3 ~ 400 High Speed (H) 230±10% ominal Voltage Supplied to Fan Motor [V] Medium Speed (M) 170±10% Low Speed (L) 130±10% Fan Motor Maximum Current [A] 1,3 AOE 18 AOE 24 AOE 30 Maximum three-phase electric power input [kw] up to 15 up to 30 Air Temperature at Heater Outlet [ C] 40±2 Weight [kg] 5 6 225 205 161 115 382 364 Fig. 1. Overall and Connecting Dimensions

www.ventilation-system.com 7 DESIG AD OPERATIG LOGIC The control unit is protected with a metal casing (Fig. 1 and 2). The control unit is activated and deactivated by means of the switch with an indicator light installed on the side panel. The power leads are routed into the control unit through sealed lead-ins. The wires are connected to the terminal blocks according to the connections diagram. The unit is equipped with resettable fuses for short-circuit protection and an electric motor fuse. The single-phase electric motor operation mode is selected by means of the knob on the control unit casing allowing single-speed or triple-speed operation. The fan speed is controlled by means of the TRIAC regulator. The electric heater output is controlled by means of the dedicated TRIAC regulator. The air stream temperature adjustment algorithm is based on the heater activation/deactivation time (full power) control depending on the dialed heating requirements. Switch Terminal Block Sealed Lead-In Sealed Lead-In Motor fuse Terminal Block Fan Speed Selector Controller Circuit Board Fuse Fig. 2. Control Unit Design ISTALLATIO AD SETUP Having unpacked the control unit and prior to the installation: Carefully read the instructions specific to the control unit installation, operation and maintenance; Check for signs of transit damage; Check for any foreign objects which may have penetrated into the unit casing. Follow the safety regulations during the make-ready procedures and control unit operation.

8 UET Control Unit Installation. Secure the control unit to the AOE warm air heater in the vertical position as shown on Fig. 3. Fig. 3. Control Unit Installation Digital Thermostat Installation. The Control Unit is operated in combination with the indoor digital thermostat (not included in delivery package) of the following two types: RTS-1-400 (RTSD-1-400) and TST-1-300 (TSTD-1-300) (Fig. 4). Since the digital thermostat controls the warm air heater operation mode it must be installed on the premises being served by the warm air heater. The digital thermostat is designed for indoor wall mounting. The digital thermostat should be installed at the height of 1.5 m from the floor level. To ensure correct operation of the warm air heater the thermostat should not be installed near windows, doors as well as heating and cooling equipment (Fig. 5). RTS - 1-400 RTSD - 1-400 (with remote-positioned control panel) TST - 1-300 TSTD - 1-300 (with remote-positioned control panel) Fig. 4. Digital Thermostats

www.ventilation-system.com 9 Fig. 5. Digital Thermostat Installation COECTIO TO POWER MAIS DISCOECT THE WARM AIR HEATER FROM THE POWER MAIS PRIOR TO AY ELECTRICAL WORK. THE COTROL UIT MUST BE COECTED TO THE POWER MAIS BY A PROFESSIOAL ELECTRICIA QUALIFIED FOR UASSISTED OPERATIOS WITH ELECTRICAL ISTALLATIOS UP TO 1,000 V AFTER BEIG MADE FAMILIAR WITH THE PRESET OPERATIO MAUAL. THE OMIAL ELECTRICAL PARAMETERS OF THE COTROL UIT ARE STATED O THE FACTORY STICKER. AY TAMPERIG WITH THE ITERAL COECTIOS IS PROHIBITED AD WILL VOID THE WARRATY. THE COTROL UIT MUST BE COECTED TO THE EARTH LOOP! The control unit is designed for connection to 400 V / 50 Hz three-phase AC mains. The control unit connections (cables and wires) must be durable, insulated and heat-resistant. The external lead-in must be equipped with an automatic cutout switch built into the stationary wiring to disconnect all the power mains phases. The external switch position must ensure free access for quick power-off of the unit. The recommended automatic switch nominal current should be based on the specific AOE air heating unit. The recommended conductor section and automatic switch nominal current values are given in Table 2. However, the conductor selection shall be based on the maximum permissible wire heating depending on the wire type, its insulation, length and installation method (i.e. overhead, in pipes or inside the walls). Table 2. Recommended Automatic Switch ominal Current and Conductor Section Values ame of the air heating unit Automatic Switch Current [A] Conductor umber and Section [mm 2 ] AOE-9 20 5х2,5 AOE-12 25 5х2,5 AOE-15 31,5 5х4,0 AOE-18 40 5х6,0 AOE-24 50 5х10,0 AOE-30 63 5х10,0

10 UET Control Unit Connection. Remove the control unit lid. Route the power leads into the unit through the sealed lead-ins. The external electrical conductors are connected to the air heating unit via bolt-down terminals. The fan motor is powered through the K1 cable of which one end is connected to the UET at the factory and the other routed outside through the lower right sealed lead-in (Fig. 2). The wires on the outside end of the K1 cable have terminals for connection to the fan motor screw terminal block. The K1 cable connection to the fan motor is shown in Table 3. Table 3. Control Unit Connection Cable Wire Markings Circuit Motor Connection Circuit 1 U1 L 2 U2 Yellow and Green PE PE 3 Z Z The earth clamp must be connected to the earth loop! Select the single-speed or the triple-speed operation mode by setting the fan speed selector to «V1» or 3» correspondingly (Fig. 1). Complete the electrical connections according to the diagram (Fig. 6-9). To connect the unit according to the diagram shown on Fig. 7 and Fig. 9 remove the jumper o. 68 between contacts X2.1 («L») and X4.1 («L1»). Type TST (TSTD) RTS (RTSD) MH "White" T1 MМ 3 4 5 1 6 7 2 3 4 6 9 1 ML O "Green" "Yellow" "Gray" L M1 * 1 L PE Z 2 "Yellow and Green" "3" C1 - C1 Capacitor E1..E3 Electric Heater (tubular electric heater) М1 Fan Electric Motor QF1 4-pole Automatic Switch T1 Temperature Regulator (Thermostat) ТК1 50 C Thermal Protection TK2 90 C Thermal Protection RT1 Temperature Sensor * - the connection option depends on the motor type E1 E2 1A 1B VS1 VS3 MH MM ML VO L Thermostat X23 MH MM ML VO U1 U2 PE Z Controller X24 Fan X1 E3 1C Control unit for the air heating unit UET-15D X4 X2 X39 X25 400 V 230 V ТК GROUP XS15 XS12 L1 L2 PE L PE Q1 TK21 TK22 Gr1 GD Gr2 32 33 34 35 400 V АС/50Hz QF1 L1 L2 62 63 RT1 PE TK2 TK1 Fig. 6. UET-15D T1Wiring Diagram (automatic switch) M1 * Type TST (TSTD) RTS (RTSD) MH MМ ML O L 3 4 5 1 6 7 2 3 4 6 9 1 "White" "Green" "Yellow" "Gray" 1 L PE Z 2 "Yellow and Green" "3" C1 - C1 Capacitor E1..E3 Electric Heater (tubular electric heater) QF-pole automatic switch М1 Fan Electric Motor KM1 4-pole Contactor T1 Temperature Controller (Thermostat) ТК1 50 C Thermal Protection TK2 90 C Thermal Protection RT1 Temperature Sensor * - the connection option depends on the motor type E1 E2 1A 1B VS1 VS3 MH MM ML VO L Thermostat X23 MH MM ML VO U1 U2 PE Z Controller X24 Fan X1

www.ventilation-system.com PE TK2 RT1 TK1 11 Type TST (TSTD) RTS (RTSD) MH T1 MМ ML O L 3 4 5 1 6 7 2 3 4 6 9 1 "White" "Green" "Yellow" "Gray" M1 * 1 L PE Z 2 "Yellow and Green" "3" C1 - C1 Capacitor E1..E3 Electric Heater (tubular electric heater) QF-pole automatic switch М1 Fan Electric Motor KM1 4-pole Contactor T1 Temperature Controller (Thermostat) ТК1 50 C Thermal Protection TK2 90 C Thermal Protection RT1 Temperature Sensor * - the connection option depends on the motor type E1 E2 1A 1B VS1 VS3 MH MM ML VO L Thermostat X23 MH MM ML VO U1 U2 PE Z Controller X24 Fan X1 E3 1C Control unit for the air heating unit UET-15D X4 X2 X39 X25 400 V 230 V ТК GROUP XS15 XS12 L1 L2 PE L PE Q1 TK21 TK22 Gr1 GD Gr2 32 33 34 35 400 V АС/50Hz KM1.1 L1 L2 230 V АС/50Hz L1 QF1 PE TK2 KM1 62 63 RT1 TK1 Fig. 7. UET-15D Connection Diagram (electromagnetic contactor) Type TST (TSTD) RTS (RTSD) MH T1 MМ ML O L 3 4 5 1 6 7 2 3 4 6 9 1 "White" "Green" "Yellow" "Gray" M1 * 1 L PE Z 2 "Yellow and Green" "3" C1 - C1 Capacitor E1..E6 Electric Heater (air-handling TEH) М1 Fan Electric Motor QF1 4-pole Automatic Switch T1 Temperature Regulator (Thermostat) ТК1 50 C Thermal Protection TK2 90 C Thermal Protection RT1 Temperature Sensor * - the connection option depends on the motor type E1 E2 1A 1B VS1 VS3 MH MM ML VO L Thermostat X23 MH MM ML VO U1 U2 PE Z Controller X24 Fan X1 E3 1C Control unit for the air heating unit UET-30D E4 2A E5 2B VS2 E6 2C VS4 X4 X2 X39 X25 400 V 230 V ТК GROUP XS15 XS12 L1 L2 PE L PE Q1 TK21 TK22 Gr1 GD Gr2 32 33 34 35 400 V АС/50Hz QF1 L1 L2 62 63 RT1 PE TK2 TK1 Fig. 8. UET-30D Connection T1 Diagram (automatic switch) M1 * Type TST (TSTD) MH MМ ML O L 3 4 5 1 6 7 L PE Z C1 C1 E1..E6 QF1 М1 KM1 T1 Capacitor Electric Heater (air-handling TEH) 2-pole automatic switch Fan Electric Motor 4-pole Contactor Temperature Controller (Thermostat)

RT1 12 PE UET TK2 TK1 Type TST (TSTD) RTS (RTSD) MH T1 MМ ML O L 3 4 5 1 6 7 2 3 4 6 9 1 "White" "Green" "Yellow" "Gray" M1 * 1 L PE Z 2 "Yellow and Green" 3 C1 - C1 Capacitor E1..E6 Electric Heater (air-handling TEH) QF-pole automatic switch М1 Fan Electric Motor KM1 4-pole Contactor T1 Temperature Controller (Thermostat) ТК1 50 C Thermal Protection TK2 90 C Thermal Protection RT1 Temperature Sensor * - the connection option depends on the motor type E1 E2 1A 1B VS1 VS3 MH MM ML VO L Thermostat X23 MH MM ML VO U1 U2 PE Z Controller X24 Fan X1 E3 E4 1C 2A Control unit for the air heating unit UET-30D E5 2B VS2 E6 2C VS4 X4 X2 X39 X25 400 V 230 V ТК GROUP XS15 XS12 L1 L2 PE L PE Q1 TK21 TK22 Gr1 GD Gr2 32 33 34 35 400 V АС/50Hz КМ1.1 L1 L2 230 V АС/50Hz L1 QF1 PE TK2 KM1 62 63 RT1 TK1 Fig. 9. UET-30D Connection Diagram (electromagnetic contactor) Digital Thermostat Connection. The thermostat is connected via the K2 cable of which one end is connected to the UET at the factory and the other routed outside through the upper right sealed lead-in (Fig. 2). The wires on the outside end of the K1 cable have terminals for connection to the thermostat screw terminal block. The K2 cable connection to the thermostat is shown in Table 4. Table 4. Thermostat Connection Cable Wire Markings Circuit Thermostat Connection Circuit RTS (RTSD) TST (TSTD) Gray L 1 7 Blue 9 6 White MH 2 3 Brown MM 3 4 Green ML 4 5 Yellow VO 6 1 The control unit allows using the same digital thermostat to control several heating units (Fig. 10). Such solution is recommended when several heating units are used for thermal conditioning of the same premises. The same digital thermostat must not be used to simultaneously control more than 10 heating units while using connector cables of 0.75 mm2 in cross-section and maintaining the total length of interconnected segments below 400 m. The connection diagram is given on Fig. 11.

www.ventilation-system.com 13 Fig. 10. Series Connection of Several Units T1 M1 * Type TST (TSTD) RTS (RTSD) MH MМ ML O 3 4 5 1 6 7 2 3 4 6 9 1 L L PE Z C1 - E1 E2 E3 E4 1A 1B 1C 2A VS1 VS3 "White" "Green" "Yellow" "Gray" MH MM ML VO L Thermostat X23 1 2 "Yellow and Green" "3" MH MM ML VO U1 U2 PE Z Controller X24 Fan Control unit for the air heating unit UET-30D X1 1 For Connecting UET-30D o. n E5 2B VS2 E6 2C VS4 400 V АС/50Hz КМ1.1 L1 L2 X4 X2 X39 X25 400 V 230 V ТК GROUP XS15 XS12 L1 L2 PE L PE Q1 TK21 TK22 Gr1 GD Gr2 32 33 34 35 KM1 62 63 Brown Blue RT1 PE TK2 TK1 E1 1A VS1 E2 1B VS3 MH MM ML VO L Thermostat X23 MH MM ML VO U1 U2 PE Z Controller X24 M1 * L PE Z 1 2 "Yellow and Green" 3 Fan X1 C1-2 E3 E4 1C 2A Control unit for the air heating unit UET-30D E5 2B VS2 E6 2C VS4 X4 X2 X39 X25 400 V 230 V ТК GROUP XS15 XS12 L1 L2 PE L PE Q1 TK21 TK22 Gr1 GD Gr2 32 33 34 35 230 V АС/50Hz L1 QF1 400 V АС/50Hz КМ1.1 L1 L2 PE Brown Blue TK2 KM1 62 63 Brown Blue RT1 TK1 For Connecting UET-30D o. n Fig. 11. Schematic Diagram for Connecting Several UET-30D Control Units

14 UET Engage the switch (Fig. 2) to power up the unit, switch the thermostat to the desired mode (see the Operation Manual for the specific thermostat type) and start the unit up. After the startup the unit operates automatically. To shut the unit down follow the start-up procedure in the reverse order. Switch off the thermostat, let the fan come to a complete halt (upon the thermostat deactivation the fan will run for two more minutes to blow the tubular electric element), then shut the unit down with the switch after the complete stop. TECHICAL MAITEACE The technical maintenance and repair of the control unit may commence only after its disconnection from the power mains. Prior to putting the unit into operation and at least every month thereon check the for any loose wires, cables, threaded joints and terminal connections. If necessary, tighten the connections avoiding damage which may impair further operation of the unit. From time to time clean the air vents of the control unit from dust and dirt. The control unit maintenance must be performed by qualified personnel after familiarization with the unit operation and design, undergoing the appropriate safety briefing and obtaining the work order authorization. TROUBLESHOOTIG Table 5. Possible Malfunctions and Their Elimination Problem Possible Reasons Elimination Method Control unit will not start The automatic breaker activates upon the unit power-up The unit is not connected to the power mains. Loose terminal connections Excessive electric current consumption caused by a short circuit. Make sure that the unit is properly connected to the power mains and make any corrections, if necessary. Switch off the control unit. Check for any loose cables in the terminals. Switch off the control unit. Contact the service centre. STORAGE AD TRASPORTATIO RULES Store the contol unit in the manufacturer s original packing box in a dry ventilated premise at the temperatures from +1 C up to + 40 C. Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion, insulation and sealing deformation. Use hoist machinery for handling and storage operations to prevent the control unit damage in consequence of falling or excessive oscillation. Fulfil the handling requirements applicable for the applicable freight type. Transportation with any vehicle type is allowed provided that the control unit is protected against mechanical and weather damage. Avoid any mechanical shocks and strokes during handling operations.

www.ventilation-system.com 15 MAUFACTURER S WARRATY The manufacturer hereby warrants normal operation of the control unit over the period of 24 months from the retail sale date provided the user s observance of the transportation, storage, installation and operation regulations. Should any malfunctions occur during the control unit operation through the manufacturer s fault during the warranty period the user is entitled to elimination of faults by means of warranty repair performed by the manufacturer. The warranty repair includes work specific to elimination of faults in the control unit operation to ensure its intended use by the user within the warranty period. The faults are eliminated by means of replacement or repair of the complete unit or the faulty part thereof. The warranty repair does not include: Routine maintenance; Control unit installation / dismantling; Control unit setup. To benefit from warranty repair the user must provide the unit, the user s manual with stamped sale date and the payment document certifying the purchase. The control unit model must comply with the one stated in the user s manual. Contact your Seller for warranty service. The manufacturer s warranty does not apply to the following cases: User s failure to provide the control unit with the entire delivery package as stated in the user s manual or with missing component parts previously dismounted by the user; Mismatch of the control unit model and make with the respective details stated on the control unit packing and in the user s manual; User s failure to ensure timely technical maintenance of the control unit; External damage to the casing (excluding external modifications of the control unit as required for its installation) and the internal components of the control unit; Alteration of the control unit design or engineering changes of the control unit; Replacement and use of the control unit assemblies, parts and components not approved by the manufacturer; Control unit misuse; User s violation of the unit installation regulations; User s violation of the control unit management regulations; Control unit connection to the power pains with a voltage different from the one stated in the user s manual; Control unit breakdown due to voltage surges in the power mains; User s discretionary repair of the control unit; control unit repair performed by any persons without the manufacturer s authorization; Expiry of the unit warranty period; User s violation of the established regulations specific to the control unit transportation; User s violation of the control unit storage regulations; Wrongful acts against the control unit committed by third persons; control unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, or blockade); Missing seals if provided by the user s manual; Failure to provide the user s manual with the sale date stamp; Missing payment document certifying the control unit purchase. FOLLOWIG THE REGULATIOS STIPULATED HEREI WILL ESURE A LOG AD TROUBLE-FREE OPERATIO OF THE COTROL UIT. USERS CLAIMS SHALL BE SUBJECT TO REVIEW OLY UPO PRESETATIO OF THE COTROL UIT, THE PAYMET DOCUMET AD THE USER S MAUAL WITH THE SALE DATE STAMP.

16 UET ACCEPTACE CERTIFICATE Product Type Control unit for the air heating unit with electric heater VETS AOE series Model UET Serial umber Manufacturing Date is hereby declared ready for service. We hereby declare that the product complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 93/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. This certificate is issued following test carried out on samples of the product referred to above. Quality Inspector s Stamp SELLER S IFORMATIO Shop name Address Telephone E-mail Sales date This is to certify delivery of the complete control unit with the user's manual. The warranty terms are acknowledged and accepted. Customer's signature Seller s seal MOUTIG CERTIFICATE The control unit UET has been connected to power mains pursuant to the requirements stated in the present user s manual. Company name Address Telephone Installation technician's full name Installation date: Signature: This is to certify that the work specific to the control unit installation has been performed in accordance with all the applicable provisions of local and national construction, electrical and technical codes and standards. The control unit operates normally as intended by the manufacturer. Signature: Installation technician s company seal

www.ventilation-system.com 17 WARRATY CARD Product Type Model Serial umber Manufacturing Date Sales date Warranty Period Sales company Control unit for the air heating unit with electric heater VETS AOE series UET Seller s seal OTES

2013 V98-1E-01