ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Similar documents
Trials Tribulations & Rewards High T Heating Systems

Medium Mass Boilers. Maxim Power VT

SmartPlate. Water Heaters. AERCO.com

Versa- Hydro. up to 96% Efficient

Applications and Piping Strategies for Condensing Boilers - Introduction

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Advanced Heating & Hot Water Systems. High Efficiency Residential & Commercial Space Heating

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

Multifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use

EZ Plate Instantaneous

Ve r s a - Hyd ro. 96% Efficient. The cost effec t i ve. ersa-hydro

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Flo-Rite-Temp Instantaneous Steam/Water Heater

ADMS. AERCO Digital Mixing Station. AERCO.com

David Cronin-Ohio Valley Area Manager. Heat Transfer, Controls & Instrumentation, Metering.

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

Flo-Rite-Temp Instantaneous Steam/Water Heater

Now Available with PVC & Polypropylene Vent Configurations

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

Hot Water Makers. Efficiency at its Best

BOILER APPLICATION GUIDE for:

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM

Innovation. Commercial Tankless Water Heaters. AERCO.com

DIGITAL HOT WATER SOLUTIONS

Outdoor Reset Control Theory FULL versus PARTIAL reset

MAXIMIZING HYDRONIC SYSTEM DESIGN PART III

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

Instantaneous Water Heaters (IWH)

FXLF-9. High Efficiency Water Heaters and Boilers

AM Rapid Recovery Water Heaters

PREMIER SERIES APARTMENT HOUSE SIZING

Get The Edge Over The Competition with The Summit

Hydronic Mechanical Panels

DUKE UNIVERSITY DESIGN GUIDELINES

Best Practices for Condensing Boilers

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS

Eco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

COMMERCIAL SPACES WATER HEATING SOLUTIONS WATER HEATERS

Suggested Specifications Prestige Excellence 110

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Warmth, efficiency, and total peace of mind.

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

hydronics WHAT S WRONG WITH THIS SCHEMATIC?

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

TOTAL SYSTEM EFFICIENCY: CONTROL STRATEGIES & SYSTEM DISTRIBUTION. David Grassl PE Mechanical Engineer Principal

Domestic Hot Water Heaters and Boilers FTIIIC-6

FTIIIC-10. Domestic Hot Water Heaters and Boilers

AM Series. High-Efficiency Boilers and Water Heaters

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Originators of the Flexible Water Tube design

AM Series. High-Efficiency Boilers and Water Heaters. AERCO.com

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

Systems and Tanks. 40 H/V 60 H/V 80 V 115 V 139 V Gallon. Applications Sizing System Design

Originators of the Flexible Water Tube design


The Evolution of. Hot Water. Generation Systems. -Ron George. Geysir at Haukadalur, Iceland ( Ron George, 2016)

Intro to Commercial Tankless Technology

YOUR COMPREHENSIVE LOCHINVAR SUPPLIER

Boiler Basics: Design & Application Differences. Presented by Steve Connor July 30, 2014

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

"Best Practices in Modern Hydronic Heating - THE DETAILS

AM Series. High-Efficiency Boilers and Water Heaters

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

TANKLESS PRODUCT GUIDE

TANKLESS PRODUCT GUIDE

- Essay Control Functions and Benefits

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

HTP s history of developing new and innovative products has allowed the company to grow over 18 % annually for the last 10 years.

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

Raypak Residential Products

Automatic Temperature Controller (ATC)

TABLE OF CONTENTS BRADFORD WHITE BOILERS

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5)

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

Innovation. Commercial Tankless Water Heaters. AERCO.com

Thermal Efficiency Gas-Fired High Efficiency Unit Heater

Date: Project #: Engineer: Prepared By: Bid Date:

Triton Series High Efficiency Boiler

Originators of the Flexible Water Tube design

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

MACH CI. (Condensing-Indirect) Water Heating

MASCOT II. Gas-Fired Wall-Mounted Combination Boiler & Water Heater

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

KN-SERIES GAS-FIRED DIRECT VENT CAST IRON BOILERS KN-6 KN-10 KN-20

Steven Winter Associates, Inc. J827

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Vitocrossal 300, CU3A - Introduction

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

940ES Tankless Water Heater

Small Building Program Design Phase Assistance

heat interface units A BOILER WITHOUT A FLAME

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

Advanced Heating & Hot Water Systems

Transcription:

ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Presentation Overview Water Heater Piping Strategies How to size a water heater? How to size a storage tank? Traditional System Non-condensing water heater and storage tank Condensing Water Heaters with storage Condensing Water Heaters without storage Utilizing the Boiler Plant Water to Water Heater

How to Size a Water Heater Fixture Count ASHRAE Handbook Service Water Heating Hunter Curve Occupancy Load Diversity

ASHRAE -Service Water Heating

ASHRAE -Hot Water Demands

How to Size a Storage Tank Reason for Storage? Protect system from poor temperature control Protect water heater from condensing conditions How to Size a Storage Tank? Typically depends on requirements set by water heater manufacturer Common rule of thumb 125 gallons storage/500 MBH

Traditional System Non-condensing Water Heater Requires a bypass or 3-way valve to maintain inlet water temperatures above 140 F Requires Storage Tank & System Recirculation Necessary to maintain accurate temperature control, due to lack of modulation capability Storage tanks failure will shut down entire domestic water system

Traditional System Wastes Energy Non-condensing water heaters can only reach maximumefficiencies in the mid 80 s Must keep set point at a minimum of 140 F Higher standby/radiant losses Higher burner cycling losses Additional electrical consumption of full flow circulators

Traditional System Larger Installed Footprint Water heater & tank Higher Risk of Legionella Must keep tank at 140 F min. Extra Piping Higher installation cost Added Maintenance Additional components that need to be serviced and maintained

Condensing Water Heaters With Storage Storage Heaters Tank and integral heat exchanger Hot Water Supply Boiler with Separate Storage ASME H Stamp Classified as a boiler Published efficiency is based on ANSI Z21.13 Tested at Full Fire: 80 F -180 F Does not take into account electrical consumption and radiant losses Most Common Designs: Copper Fin primary, Stainless Steel secondary HX 300 series Stainless Steel Water tube HX

Condensing Water Heaters with Storage

Condensing Water Heaters With Storage Common Disadvantages: Larger footprint Typically require 125 gallons of storage per 500 MBH Legionella Risk 140 F set point required Wastes energy & requires mixing station (added cost) Higher standby/radiant losses Limited Warranty Typically 3-5 Year Warranty on Heat Exchanger

Condensing Water Heaters With Storage Added Disadvantages of Separate Storage High Flow Circulator Higher energy consumption Extra piping Limits the effectiveness of condensing Added Maintenance

Condensing Water Heaters without Storage Tankless/Semi-Instantaneous Water Heaters ASHRAE defines a semi-instantaneous water heater as having an Input to Storage Ratio of 4,000 Btu/h per gallon or greater Heat Exchanger material of construction must be suitable for condensing application Stainless Steel Fire Tube Heat Exchanger Reduce risk of scale compared to water tube hx Lower waterside pressure drop compared to water tube hx Less pump electrical consumption compared to water tube hx

Condensing Water Heaters without Storage Requires advanced controls with feed forward & feedback control system Requires high turndown/modulation 14:1 or greater Reduce cycling losses Reduce wear and tear on equipment Extends life of product

Maximize Efficiency

When Storage Should Be Utilized Dump Loads Peak Load for Short Time Commercial Laundry Gang Showers Cage Washers

Maximize Efficiency with Storage Tank

Utilizing a Boiler Plant Water to Water Heater Add indirect domestic load to oversized boiler plant Utilize boiler water to heat domestic water Optimal Heat Exchanger Brazed Plate/Plate & Frame HX Requires advanced controls for accurate temperature control Feedback & Feed forward controls Low boiler water supply and return temperatures - Eliminate waste associated with overheating - Reduce fuel consumption and maximizes boiler efficiency -Reduce radiant losses by up to 15%

System Integration Successful integration with hydronic boilers Ensures acceptable temperature control Minimizes boiler cycling Key Considerations Thermal mass of overall system Year-round load characteristics Peaks and valleys in DHW demand With Low Mass and Fast, Diverse DHW Loads Boiler-side buffer tank may be required (not DHW storage) Should conform with boiler manufacturer recommendations

High Mass System Sufficient water volume in boiler or system piping ensures minimal boiler cycling Can be either a condensing or non-condensing boiler If using a non-condensing boiler, must include bypass line with circuit-setter to ensure 140 F return water temperature

High Mass System Note: Size bypass line to ensure that RWT to non-condensing, high mass boilers always remains above 140 F

Low Mass System Insufficient water volume in boiler or system piping between the boilers and the heaters to ensure minimal boiler cycling Can be either a condensing or non-condensing boiler with average to low turndown, 5:1 or less If using a non-condensing boiler, must ensure 140 F return water temperature

Low Mass System Utilizing a Condensing Boiler with high turndown Turndown greater than 15:1

Low Mass System For use when DHW is the only load on the system (spring/summer) Allows for main system pump shut down

Low Mass System Hydronic buffer tank vs. domestic storage tank In a closed system, corrosion failure is unlikely to occur as quickly as in an open loop Operating temperatures are not limited to >140 F No fear of Legionella bacteria growth Does not require glass or cement lining Less expensive

Optimum Instantaneous Heater Brazed plate and plate and frame are the most efficient water to water heat exchangers available Only requires a +5 F approach temperature vs. DHW set point Result: Lower boiler supply and return temperatures Ideal with high-efficiency, condensing boilers in low temperature applications

Optimum Instantaneous Heater Reduce maintenance costs Plate HX s stand up better in DHW environment 316 SS plate construction for high corrosion resistance Maintain minimum flow velocity and reduce scale dropout Easy to clean when required Reduce future replacement cost Higher cost for domestic storage systems

Optimum Instantaneous Heater Requires accurate temperature control for safe operation and to eliminate the need for storage Should have PID Controls with feed-forward and feedback sensor inputs Should have a fast-acting electronic control with failsafe actuator Should include an integrated safety shutoff system

Utilizing a Boiler Plant Low boiler water supply and return temperatures Eliminate waste associated with overheating Reduce fuel consumption and maximizes boiler efficiency Reduce radiant losses by up to 15% Lower Boiler Water Flow Requirements Less pumping HP Smaller piping requirements Lower Domestic Set Point Temperature Reduces scale No storage tanks or mixing valves Increased heater thermal efficiency Reduced maintenance Longer heater life

Summary Purpose of Storage Protect system from water heater with poor temperature control Protect gas fired water heater from condensing conditions Most Efficient Design Gas Fired Water Heater Condensing, High Turndown, Semi-Instantaneous/TanklessWater Heater without Storage Utilizing a Condensing Boiler Plant with a Water to Water Heater Optimum Water Heater Brazed Plate/Plate & Frame with feedforward & feedback controls coupled with a fast acting electronic control valve Consider total system design when selecting products DESIGN A SYSTEM WITH A LONG LIFE THAT WILL MAXIMIZE EFFICIENCY AND REDUCE ENERGY COSTS!

Questions 1. When should storage be utilized? 2. What is the optimum heat exchanger for water to water heat transfer? 3. Why is turndown important? 4. What is the minimum temperature that a storage tank must be kept at? 5. What type of tank is most likely to fail? Buffer Tank or Storage Tank 6. What material is best suited for gas fired condensing equipment? 7. What does a buffer tank reduce in boilers in Low Mass Systems?