Operation Manual Part-No

Similar documents
Operation Manual Version 1.2

Installation Instructions

Engine Protection Partner AS

Advantages of automatic boiler bottom blowdown

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Beckhoff short profile

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

Compact FREME. flash recovery energy management equipment HEAT TRANSFER SOLUTIONS

CRA24-B3 controlled residential ventilation

The advantages of closed heating systems. White paper

Accuracy counts! Sensors with analog output

EU directives WEEE and RoHS. Information and notes

stylemakerstm SINCE 1895

Fire-Resistant. Automatic Doors

Rotary Screw Compressors SXC»Compact«Series

OIL MIST DETECTION SYSTEMS VISATRON

International standards used locally worldwide ISO/TC 67

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

STT 3000 Series STT250 /150 Surge Protection Device Specifications

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Content. Introduction. Objetive Summary. Business. Trends

Nationwide Footprint International Reach

SBA Profile. Privacy Statement (Back to Profile List, or use Back button) Identification, Location & Contacts

Rotary Blowers COMPACT Series With the world-renowned OMEGA PROFILE Air delivery 0.5 to 93 m 3 /min Pressure up to 1000 mbar, Vacuum to 500 mbar

PTG, SWT Series. Heat Recovery Systems

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Rotary Screw Compressors SXC»Compact«Series. With the world-renowned SIGMA PROFILE FAD 0.26 to 0.8 m 3 /min, Pressures bar

L-force Drive-based Safety. Safe, scaleable and above all integrated

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier!

Signal converters SVE4 Product overview

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Expansion vessel in a solar installation. White paper

Future development of the furniture industry A look at the next 3-5 years

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

Textile fire protection closures EI 30/90

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition

KNX The worldwide STANDARD for home and building control. KNX Association International

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

AutoM Click to go to the page. AutoM Auto Shaker Filter

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Product Warranty and Installation Bulletin for LC5511 Calendered Window Decoration Film

WIO200 Water in oil sensor

Return loss measurement of fiber optic components

Value engineering developed from global experience

KNX The worldwide STANDARD for home and building control. KNX Association International


Foreword. A completely revised report for quicker and easier access to key information

MKN Galley Solutions

Operating Manual MS220DA

Type Approvals GARAGE DOOR OPENER RADIO TRANSCEIVER. (EuroHomeLink 2000) Czech Republic CTU R 1194 Cyprus MCW129/95 12/2000 Denmark 98.

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Air and dirt in closed systems

WORLDWIDE DISTRIBUTORS

Gas meters - Conversion devices - Part 1: Volume conversion

Certificate of constancy of performance,

Heinz Lux. Director, KNX

Installation Manual. SiCOMS. Oil mist Concentration monitoring Diesel- and `-Version. Part No.: Release: (revision )

Labeling and Identification Products

COMMUNICATION SYSTEMS FOR AND REMOTE READING OF METERS - PART 2: PHYSICAL AND LINK LAYER IRISH STANDARD I.S. EN :

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

International Product Compliance and Certifications. Product Safety Consulting, Inc.

STANDARD T6 (200 C) SENSOR CABLE RANGE

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Instruction Manual. Mink. Claw Vacuum Pumps MM 1402 AV, MM 1502 AV. Busch Produktions GmbH Schauinslandstraße 1, Maulburg Germany

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

FieldLink Cable solutions for Automation & Drives

Line Isolation Monitor (LIM) LIM2000plus

Instruction Manual. Seco. Dry-running Rotary Vane Vacuum Pumps SV 1003 D, SV 1005 D

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

This document is a preview generated by EVS

Battery Industry EFFICIENT APPLICATIONS SOLUTIONS

This document is a preview generated by EVS

Pillow Plate Heat Exchanger SYNOTHERM

Sýnishorn Health care services - Quality management systems - Requirements based on EN ISO 9001:2015

CONFORMITY ASSESSMENT - SUPPLIER'S

Achieving Functional Safety with Global Resources and Market Reach

EC3-X33 Stand-alone Superheat Controller

DC 60 & DM 60 displays

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

WIO 200B and WIOI200B Water in oil sensor

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

English version. Alarm systems Terms and definitions

Chromalox PRECISION HEAT AND CONTROL. Generating Value-Added Heating Solutions for the Power Generation Industry

Instruction Manual PB 0003 D. Rotary Vane Vacuum Pumps. Busch Produktions GmbH Schauinslandstraße 1, Maulburg Germany

Contents. +0 % VS 2016 On page 1 you will find the key indicators at a glance : chains in the country: 2016 and 2017 sales, number of stores,,

Hello. We d like to introduce you to our family

RETAIL TRADE AS AN ACTOR IN BALANCED SPATIAL PLANNING AND SUSTAINABLE DEVELOPMENT

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Contents. EN :2012 (E) Issue 5 ( ) Page

Sýnishorn Maintenance - Qualification of maintenance personnel

Transcription:

Version 2.2, 08/2016 VISATRON Remote Indicator II For Oil Mist Detectors Operation Manual Part-No. 180050 VNxxx/87plus VNxxx/93 VNxxx/87-EMC VN115/87plus EX VN301plus (EX) Part-No. 150998

Page 2 of 20 About this Manual This operation manual (Part-No. 180050) was designed to answer your questions concerning the handling, operation and maintenance of the Remote Indicator II. It contains no details about repairs. Should you encounter any interruptions or breakdowns during operation, please contact SCHALLER AUTOMATION Industrielle Automationstechnik GmbH & Co. KG. You can expect a safe and reliable operation of the Remote Indicator II only when the device is operating in accordance with this operation manual. Please note the following rules: This operation manual is valid only for the connection of the Remote Indicator II to Oil Mist Detectors (OMD) VISATRON devices series VN93, VN87-EMC, VN87plus, VN87plus EX and VN301plus (EX). Please acquaint yourself with the operation manual. Read the operation manual carefully and take into account the advice given. Use the Remote Indicator II only for the purpose described in the operation manual. Incorrect maintenance and handling errors may cause failures and accidents! The Remote Indicator II may be used by authorised specialised staff only. This operation manual must be available at the place of installation at all times. The manufacturer does not accept any guarantees resulting from improper handling or insufficient maintenance and service. SCHALLER AUTOMATION Industrielle Automationstechnik GmbH & Co. KG precludes all guarantees for the case that incorrect device combinations are operated with devices not certified to be compatible or not admitted by the manufacturer. Conditions of Sale The standard conditions of sale of SCHALLER AUTOMATION (current version) shall apply to all sales of VISATRON and connected products to any of our customers.

Page 3 of 20 Safety instructions The Remote Indicator II is manufactured according to the high quality standard of SCHALLER AUTOMATION and passes the stringent factory tests. In order to keep the device in a smooth and problem free operation, the user has to take note of the safety hints and warnings. In the instruction manual and at the device they are marked with the following symbol. Used symbols CAUTION! Do not ignore the warnings. The safety of persons can be imperilled or the device can be damaged. WARNING! The marked text contains important information. The marked text contains only a hint for faster processing.

Page 4 of 20 Declaration of Conformity We, the manufacturer SCHALLER AUTOMATION Industrielle Automationstechnik GmbH & Co. KG Industriering 14 D-66440 Blieskastel Tel.: 06842 / 508-0 Fax: 06842 / 508-260 declare on our own responsibility, that the product: Kind of equipment: Type-designation: Monitoring Device VISATRON Remote Indicator II Part-No.: 150998 is in compliance with following norms : EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 CISPR 16-1 CISPR 16-2 D-66440 Blieskastel, 2007/01/22 Stephan Schaller - Managing Director -

Page 5 of 20 Table of Contents 1 Introduction and functional overview... 6 2 Installation instructions... 7 2.1 Mechanical Installation... 7 2.2 Electrical installation on OMD-type VN93 or VN87plus (EX)... 9 2.3 Optional VN87-EMC operation mode... 12 2.4 Schematic Connection Diagram... 14 3 Functional description... 15 4 Maintenance procedures... 16 5 Accessories... 17 6 Technical data... 18 7 Service Partners... 19 8 Notes... 20

Page 6 of 20 1 Introduction and functional overview In combination with the Oil Mist Detection devices VISATRON, the Remote Indicator II from SCHALLER AUTOMATION enables a user-friendly monitoring of the Schaller OMD device, as part of a safety system at large Diesel engines. The Remote Indicator II allows the safe remote monitoring of the oil mist concentration from outside the engine room e.g. from the engine control room. The device can be connected to VISATRON devices of series VN93, VN87plus, VN87plus EX, VN87-EMC and VN301plus (EX). In use with a VN93, VN87plus or VN87plus EX, it is possible to monitor the relative opacity and the state of one OMD device similar to the OMD display. The connection to the VN93 and VN87plus (EX) units is realized by a RS485 two-wire bus. Optional the Remote Indicator II can be connected to a VN87-EMC unit. This connection to the VN87-EMC is realized as a two-wire analog interface. If a VN87- EMC is connected to the Remote Indicator II, the device monitors only the oil mist concentration and not the state of the OMD device. In this case and to fulfil the IACS requests, it is necessary to monitor the status of the Ready- and the Alarm- Relay from the VISATRON device separately in your safety system. Figure 01: Remote Indicator II

Page 7 of 20 2 Installation instructions 2.1 Mechanical Installation slot size IEC 61554, 92+0.8 mm x 45+0.6 mm Step 1: Step 2: Prepare the slot as specified. Select either the normal glass plate a) for vertical installation, the additional glass plate c) for horizontal installation (included in scope of supply) or glass plate b) for VN87mode (see VN87-EMC operation mode) a b c Figure 02: Front glass plates for a) VN87puls (EX)/VN93 vertical connection to OMD b) VN87-EMC vertical type c) VN87plus (EX)/VN93 horizontal Step 3: Put the device into the slot (see figure 3). Step 4: Clip the fixing screws (see figure 4). Step 5: Fix the device by turning the screws.

Page 8 of 20 Figure 03: Insert the Remote Indicator II into the slot and push the holding frame on the device Figure 04: Mounting the fixing screws

Page 9 of 20 2.2 Electrical connection to OMD-type VN93 or VN87plus (EX) The electrical installation consists of following steps: Step 1: Step 2: Step 3: Step 4: If OMD-type is VN93 or VN87plus (EX): Installation of the Terminator and the grommet on the OMD device, Connection of the VISATRON devices to the Remote Indicator II, Switch-on the VISATRON OMD, Connection of the power supply to the Remote Indicator II device. Figure 05: Cable entry and terminator on the bottom side of the VISATRON devices It is necessary to terminate the data link on both sides of the cable. In the Remote Indicator II a terminating resistor is already integrated. The terminator (see figure 06) for the VN93 or VN87plus (EX) unit is scope of supply of the Remote Indicator II package as well as the grommet for the cable entry. Figure 06: Terminator

Page 10 of 20 All electrical connections of the Remote Indicator II are accessible at the rear connector of type Phoenix Contact MC 1,5/12-GF-3,81 (see figure 07) and the plug FK-MCP 1,5/12-STF-3,81. Screws (Description see VN87-EMC operation mode) Figure 07: Connector at the rear side of the Remote Indicator II The following tables show the pin assignment of the Remote Indicator II connector (see also the VISATRON VN93 and VN87plus (EX) manual). Remote Indicator II to VN93 or VN87plus (EX) Oil Mist Detector Name Pin-No. Connected to RS485 A 1 pin 13 of VN93 and VN87plus (EX) RS485 B 2 pin 11 of VN93 and VN87plus (EX) RS485 GND 3 Optional current interface + 4 Optional current interface - 5 VN87 PWM interface + 6 VN87 PWM interface - 7 4-20mA Output + (max. 220Ohm) 8 optional to alarm monitoring system 4-20mA - Output - 9 optional to alarm monitoring system Earth 10 earth and data cable shield Power supply GND 11 0 Volts Power supply 24Volts 12 + 24Volts DC Table 01: Pin assignment and connection to VN93 or VN87plus (EX)

Page 11 of 20 The used data cable must be twisted pair and shielded. The total bus length is limited to 400 m. The grommet (see figure 05) at the VISATRON device is designed for cable diameter between 7,5 and 10,0 mm. We recommend LAPPKABEL UNITRONIC-FD CP (TP) plus UL-CSA, AWG20. The shield must be connected directly at the grommet! After the correct electrical connection and a power-up phase of 30sec, following display appears: green green Figure 08: Ready Mode If the serial RS485-connection between the VISATRON Remote Indicator II and the VISATRON OMD device can not be established, the Ready-LED is blinking. In this case check that the OMD device is switched on and the wires of the communication cable are not interchanged.

Page 12 of 20 2.3 Optional VN87-EMC operation mode First step to adjust the VN87-EMC operation mode: Switch off the power!! If the Remote Indicator II is connected to a VN87-EMC unit, following pin assignment is valid: Remote Indicator II to VN87-EMC Oil Mist Detector Name Pin-No. Connected to RS485 A 1 RS485 B 2 RS485 GND 3 Optional current interface + 4 Optional current interface - 5 VN87 PWM interface + 6 pin 9 of VN87 VN87 PWM interface - 7 pin 10 of VN87 4-20mA Output + (max. 220 Ohm) 8 optional to alarm monitoring system 4-20mA Output - 9 optional to alarm monitoring system Earth 10 earth and data cable shield Power supply GND 11 0 Volts Power supply 24Volts 12 + 24Volts DC Table 02: Pin assignment and connection to VN87-EMC To enable the VN87-EMC operation mode a jumper (also scope of supply) has to be installed inside the Remote Indicator II. First you have to remove the window at the front side and then open the two screws at the rear side (see figure 07). Now the jumper can be installed (see figure 09). Carefully push the PCB back inside the housing and lock the two screws. At least mount the window at the front side. Finalize the installation by mounting the window at the front side using front glass plate b) (see Fig. 2) for vertical VN87-EMC installation

Page 13 of 20 Jumper Figure 09: PCB with jumper

Page 14 of 20 2.4 Schematic Connection Diagram Engine room VN93 or VN87plus (EX) Ready and alarm signals T Engine control room Engine control system Optional 4 20 ma RS485 2-wire-bus Remote Indicator II Alarm monitoring system

Page 15 of 20 3 Functional description The device can be connected to VISATRON devices of series VN93, VN87plus (EX) and VN301plus (Ex). The display of the Remote Indicator II is similar to the display of the VN87plus OMD device. In normal operation mode the Power-LED and the Ready-LED are only lighting green. The LED bar on the right side shows the oil mist concentration given of unit Opacity. If the upper LED is switched on, the oil mist concentration inside the crankcase is equal or higher than the adjusted alarm level. A detected oil mist alarm state was indicated by the red Alarm-LED. If the Ready-LED is off and a LED of the LED bar is blinking, the OMD device (not the Remote Indicator!) has left the normal detection mode. The reason can be found out by reading the corresponding error code (see Table 03). Optional the Remote Indicator II can be connected to a VN87-EMC unit. In this case, the device monitors only the oil mist concentration and not the state of the OMD device. In this case, it is necessary to monitor the status of the Ready- and Alarm-Relay from the VISATRON device separately with your safety system. Also an error of the VN87-EMC will not be displayed by the Remote Indicator II. Figure 10: Front panel of the Remote Indicator II

Page 16 of 20 Blinking LED on Remote Indicator II VN87plus (EX) failure 14 Negative pressure/airflow too low VN93 failure Negative pressure/airflow too low VN301plus (EX) failure Supply pressure out of limits 13 Optical sensor dirty Optical sensor dirty Optical sensor dirty 12 Voltage of internal Voltage of internal Not used battery too low battery too low 11 Ambient temperature too low (<0 C) Ambient temperature too low (<0 C) 10 Ambient temperature too high (>70 C) 9 Electronics temperature too low (<0 C) 8 Electronics temperature too low (>75 C) 7 Reset button defective 6 Supply voltage too high 5 Switch for adjusting sensitivity defective 4 Optical sensor defective 3 Airflow-sensor defective 2 Electronic module defective 1 Blinking: startup phase Table 03: Error Codes Ambient temperature too high (>70 C) Electronics temperature too low (<0 C) Electronics temperature too low (>75 C) Light button defective Supply voltage too high Optical sensor defective Airflow-sensor defective Electronic module defective Blinking: startup phase Central unit electronics temperature too low (<0 C) Central unit electronics temperature too high (>85 C) Sensor unit electronics temperature error Sensor unit heat temperature error Voltage of internal battery too low Central unit supply voltage too low Base plate of sensor unit missing Sensor unit defective Airflow of Sensor unit too low Electronic module of Central unit defective Blinking: startup phase 4 Maintenance procedures Regularly clean the surface of the panel with a soft, dry cloth.

Page 17 of 20 5 Accessories Scopes of supply are all components to connect a Remote Indicator II to one VISATRON OMD-System excluding the cable. The recommended cable can be ordered in steps of 10 m. Part-No. 150993 Part-No. 310375 Part-No. 365925 Part-No. 271685 Part-No. 331056 Part-No. 331057 Part-No. 310690 Part-No. 180050 Remote Indicator II Unit Connector FK-MCP 1,5/12-STF-3,81 Grommet Network Terminator Front glass plate for horizontal VN87plus/VN93 installation Front glass plate for vertical VN87-EMC installation Jumper Manual Table 04: Scope of supply Part-No. 331055 Part-No. 230140 Front glass plate for vertical VN87plus/VN93 installation UNITRONIC cable (10m) Table 05: Accessories

Page 18 of 20 6 Technical data Mechanical data dimensions (w x h x d) standard slot size weight display 96 mm x 48 mm x 123 mm IEC 61554, 92+0.8 mm x 45+0.6 mm 210 g LED-bar with 1 green, 12 yellow, 1 red LED 1 green Ready LED 1 red Alarm LED 1 green Power LED Electrical data power supply nominal voltage communication interface to VN93 and VN87plus analog interface to VN87-EMC connector and plug rel. Opacity Output communication cable recommendation 18 Volts 31.2 Volts DC, 75mA 24 Volts DC 2 wire RS485, galvanic separated 2 wire PWM, 2 wire current loop Phoenix Contact MC 1,5/12-GF-3,81 Phoenix Contact FK-MCP 1,5/12-STF- 3,81 4 20 ma (max. 220 Ohm) LAPPKABEL UNITRONIC-FD CP (TP) plus UL-CSA, 2 x 2 x AWG20, max 400 m length, 7.5-10.0mm Ø Environmental conditions operating temperature 0-55 C storage temperature -20 80 C max. vibrations 0.7 g relative humidity up to 100% protection class IP41 Approval of classes Approval from Germanischer Lloyd for closed areas, environmental category C, installation in control panels or cabinets

Page 19 of 20 7 Service Partners Schaller Automation maintains a worldwide network of service partners in following countries: Argentina Australia Bahrain Belgium Belize Bolivia Brazil Canada Cape Verde Islands Chile Colombia Costa Rica Denmark Ecuador El Salvador Estonia France Germany Greece Guatemala Honduras Iceland India Iran Ireland Italy Japan Korea Kuwait Latvia Lithuania Mauritania Mexico Morocco Netherlands Nicaragua Norway Oman Panama Peru Philippines Poland Portugal Qatar Saudi Arabia Senegal Singapore Spain Sweden Taiwan Turkey United Arabian Emirates United Kingdom United States of America Caribbean Islands As details in relevant addresses are supposed to change, please find actual addresses of the relevant service partner under www.schaller.de or call our technical support center at the German headquarter: Tel. +49 6842 508 0

Page 20 of 20 8 Notes