Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

Similar documents
IFD-E Flame Detector User Manual

IFD-E Flame Detector User Manual

Flame Detector User Manual

FIRE IR SENSOR Flame Detection

Talentum Flame Detector User Guide

Conspec - Why use our Flame Detectors

talentum Flame detection across the spectrum Range Brochure

Talentum - Why use our Flame Detectors?

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

Instruction manual for the Infrared Point Type Flame Detector

Flame Detection Jon Sarfas

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

Dräger Flame 2500 Flame Detection

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Design Manual Installation Operation Maintenance

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Flame 2100 Flame Detection

Dräger Flame 2500 (IR3) Flame Detection

InstrumentationTools.com

Dräger Flame 2100 (UV) Flame Detection

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Dräger Flame 2350 (UV&IR) Flame Detection

SharpEye Flame Detector Selection Guide

Flame Simulator User Manual. Publication Rev. A

Dräger Flame 2370 (UV&IR) Flame Detection

Model 3300 Technical Support and Installation Manual

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Testing Emission Source ITES Operating Manual OM

MSA s Guide to Selecting the Right Flame Detector for Your Application

Pyroelectric Infrared Sensor PIR

Safety Engineering. Fire Protection Systems and Life Safety Systems

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

Reflective Beam Smoke Detector

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

We offer ceramic radiant heaters and infra-red radiant tubes.

LEARNING SPECIAL HAZARD DETECTION TYPES

Flame Detector. Model: ZT-30P. User Guide. Document Ref: GLT Zeta Alarms Limited Morfa Road, Swansea, SA1 2EN, United Kingdom

Basic Vehicle Fire Protection Manual

TECHNICAL REPORT OG MSA 20/20MI Flame Detector Evaluation, 2004

Dräger Flame 5000 Flame Detection

7800 SERIES RM7888A Relay Module

The SharpEye 40/40I (IR3) Flame Detection

TRIPLE WAVEBAND INFRARED FLAME DETECTOR

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

7800 SERIES RM7888A Relay Module

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

Open-area Smoke Imaging Detection (OSID)

ALK-V PHOTOELECTRIC SMOKE SENSOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Dräger Flame 5000 Flame Detection

The SharpEye 40/40M (Multi IR) Flame Detection

COMPACT FLAME CONTROLLER CFC 1000

7800 SERIES EC7885A/RM7885A Relay Module

FLV 40 UV Flame Detector

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

ABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.

Instructions AutroFlame IR Flame Detector BG-201/BG-21

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

Fire & Security Products. Siemens Building Technologies Group

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

ABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)

7800 SERIES EC7823/RM7823 Relay Module

Installation and Operation Manual

CCTV, HOW DOES IT WORK?

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Applications Excellent S/N Intrusion Detectors

Hydrocarbon Gas Detector

LUX Hardwired - Installation Notes

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

HYDROCARBONENGINEERING June June 2015

APPLICATION OF VISUAL FLAME DETECTION

COMPACT FLAME CONTROLLER CFC 2000

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

RS Pro Infrared Temperature Sensor

GL-CO-RFG Channel Gas Leak Alarm System

FR-A180 FR-A360. Occupancy detector. Use

HigH Performance Low cost flame Detection. Courtesy of Foster + Partners. The New 20/20M MINI FLAME DETECTOR SERIES

Fire Detection systems. UniVario industrial fire detectors for every job

Eclipse Self-Check UV Scanner

SIMRAD GD10 IR GAS DETECTOR

Design Manual Installation Operation Maintenance

Industrial Flame Monitoring

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

model No: ir20.v2 FUSE

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

Open-area Smoke Imaging Detection (OSID)

Movement-based energy control

SIMRAD GD10PE IR GAS DETECTOR

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Distributed By: M&M Control Service, INC

UV-IR Flame Detector User Manual. Model: VS-200P

Contents. 1. Fire Detection motivation. 2. SharpEye Detector Range. 3. Detector Accessories. 4. How to Specify & Locate Detectors

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Fire Detection System: An Overview

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

Transcription:

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0 Page 1 of 11

DRD-AS Flame Detector User Manual Table of Contents 1.1 Description... 3 1.2 Alarm Response Modes... 3 1.3 IR Detection Basics... 3 2 Application... 5 2.1 Detectable Fire Sources... 5 2.2 Typical Applications... 5 2.3 Applications and Locations to Avoid:... 5 3 Quantities and Positioning... 6 3.1 Field of View... 7 3.2 Detector Window Contamination... 8 3.2.1 Cleaning... 8 4 Installation... 9 4.1 Functional Testing... 10 4.2 Service & Repairs... 10 5 Detector Specifications... 11 5.1 Compatible Bases... 11 5.2 Angle Mount Bracket... 11 5.3 Tester... 11 Issued JUN,2011 Page 2 of 11 2011 Hochiki Corporation

DRD-AS Flame Detector Installation Manual General 1.1 Description The flame detector is designed for use where open flaming fires may be expected. It responds to the light emitted from flames during combustion. The detector discriminates between flames and other light sources by responding only to particular optical wavelengths and flame flicker frequencies. This enables the detector to avoided false alarms due to such factors as flicking light sources. 1.2 Alarm Response Modes The detector is normally configured to latch into an alarm state when a flame is detected. The power supply to the detector has to be removed in order to reset the detector. 1.3 IR Detection Basics Flame detectors are classified into two types by their principle of detection. UV detectors are sensitive to ultraviolet, and IR detectors are sensitive to infrared. This DRD-AS detector can detect IR radiated from flames. Flames radiated from a fire have an IR peak emission of 4.3um occurring during the CO2 formation due to the combustion of hydrocarbons from 2 to 15 Hz. Fig 1 : External View of DRD-AS Issued JUN,2011 Page 3 of 11 2011 Hochiki Corporation

DRD-AS Flame Detector - Installation Manual Fig 2 : Spectrum of white gas flame The pyroelectric device fitted within the DRD-AS detector, can detect CO2 formation during combustion through an optical filter. The output is amplified from 2 to 15 Hz. The DRD-AS detector will then make a fire decision using an AC-DC converter, comparator, and capacitor. It will then send an alarm signal to the fire panel via a switching circuit. Issued JUN,2011 Page 4 of 11 2011 Hochiki Corporation

DRD-AS Flame Detector Installation Manual 2 Application Flame detectors are used when detection is required to be: Unaffected by convection currents, draughts or wind Tolerant of fumes, vapours, dust and mist Fast reacting 2.1 Detectable Fire Sources Liquids - Aviation Fuels (kerosene), Ethanol, Methylated Spirits, n-heptane, Paraffin, Petrol (gasoline) Solids Coal, Cotton, Grain & Feeds, Paper, Refuse Wood Gases Butane, Natural Gas, Off Gas, Propane 2.2 Typical Applications Coal handling plant Aircraft hangars Atrium Automotive industry - spray booths, parts manufacture Paper manufacture Pharmaceutical Engine rooms Generator rooms Metal fabrication Waste handling Woodworking Power plants Textiles Transformer stations Petrochemical 2.3 Applications and Locations to Avoid: Ambient temperatures above 50 C Location which tends to gather dust or oil film Atmospheres containing corrosive gases Where condensation exists In the vicinity of large IR sources such as heaters, burners, flares Close proximity to RF sources Obstructions to field of view Exposure to weather Large amounts of flickering reflections Direct sunlight or its reflected light by puddle, glass, or mirror surface of metal Spot lighting directly on the detector optics Issued JUN,2011 Page 5 of 11 2011 Hochiki Corporation

3 Quantities and Positioning The number of detectors required and their position depends on: the anticipated size of the flame the distance of the flame from the detector the angle of view of the flame detector DRD-AS Flame Detector - Installation Manual The DRD-AS flame detector is designed to have a class 1 performance as defined in EN54-10 on the high sensitivity setting. That is the ability to detect an n-heptane (yellow) fire of 0.1m² or methylated spirit (clear) fire of 0.25m² at a distance of up to 25m within 30 seconds. In fact, the DRD-AS flame detector will detect fires at distances of up to 40 metres, but the flame size at such distances needs to be proportionally greater in order to be sure of reliable detection. Thus the yellow flickering flame that can be detected at 25m, provided that its size is not less than 0.1m², will have to be 0.4m² in order to be detected at 40metres. In a rectangular room the distance from the flame detector to the fire is calculated by the formula: Fig 3 : Calculation of distance from detector to flame Issued JUN,2011 Page 6 of 11 2011 Hochiki Corporation

DRD-AS Flame Detector Installation Manual 3.1 Field of View The DRD-AS flame detector has a field of view of approximately 90, as shown in the diagram below. Fig 4 : Conical field of view of the flame detector Fig 5 : Detector Field of View Plot The DRD-AS flame detector should be positioned at the perimeter of the room, pointing directly at the anticipated flame or at the centre of the area to be protected. If the detector cannot see the whole of the area to be protected, one or more additional detectors may be required. The DRD-AS flame detector is not affected by normal light sources but should be positioned so that sunlight does not fall directly onto the viewing window. Issued JUN,2011 Page 7 of 11 2011 Hochiki Corporation

3.2 Detector Window Contamination DRD-AS Flame Detector - Installation Manual It is important to keep the detector window clean and checks should be carried out at regular intervals determine locally according to the type and degree of contamination encountered to ensure optimal performance of the DRD-AS flame detector. Although IR detectors can detect flames when the window is contaminated, there may be a reduction of sensitivity. 3.2.1 Cleaning If the window of the DRD-AS flame detector is coated with dust or oil, the sensitivity to flames may decrease. To remove the contamination, use a damp cloth; please ensure to remove any excess moisture with a dry cloth. NOTE: Do not wipe the main body of the detector window with alcohol or benzine. Issued JUN,2011 Page 8 of 11 2011 Hochiki Corporation

DRD-AS Flame Detector Installation Manual 4 Installation The DRD-AS flame detector can be used in conjunction with the following mounting bases: YBN-R/6, YBO-R/6PA. A wall and ceiling mounting bracket are available if required, these should be ordered separately. Please refer to Fig 7 and Fig 8 below. Fig 6 : Installation with Mounting Base Fig 7 : Installation with ceiling bracket (YZU-A) Fig 8 : Installation with wall bracket (YZU-B with YZU-A) Fig 9 : Connection to Conventional Control Panel Issued JUN,2011 Page 9 of 11 2011 Hochiki Corporation

4.1 Functional Testing DRD-AS Flame Detector - Installation Manual A portable flame detector test unit is available to generate simulated flame behaviour (Fig 10.). To test the detector, the test unit needs to be within 600mm of the DRD-AS flame detector. The DRD-AS incorporates a 15 second delay to help filter out any transient IR sources that may occur. Between each test the DRD-AS flame detector will need to be left for minute to allow for stabilisation. If it is safe to do so, a naked flame could also be used to test the DRD-AS flame detector, please ensure that the flame is not exposed directly to the outer casing or lens as damage may occur. < 600mm Fig 10 : Portable Flame Detector Test Unit (Model Name:016061) 4.2 Service & Repairs Servicing of the fire protection system should be carried out by competent persons familiar with this type of system, or as recommended by the local regulations in force. Only the manufacturer or equivalent authorised body may carry out repairs to the flame detectors. In practical terms this means that flame detector may be repaired only at the manufacturer s factory. Issued JUN,2011 Page 10 of 11 2011 Hochiki Corporation

DRD-AS Flame Detector Installation Manual 5 Detector Specifications Ordering code DRD-AS Operating voltage 15-30 Vdc (Nominal rating 24Vdc) Standby current 70 ua at 24Vdc Delay time 15 to 21 Second Detection angle 90 Cone Infrared sensitivity range Class 1 0.1m 2 n-heptane at 25m Maximum current in alarm state 40mA Remote indicator drive(max) 20mA Operating temperature range -10 C to +50 C Maximum humidity 95%RH - Non condensing (at 40 C) Colour and case material White Ivory ABS Weight 125g 5.1 Compatible Bases Order Code Description YBN-R/6 Common Mounting Base. YBO-R/6PA For use with compatible 2-Wire systems. NOTE: Alarm control panel compatibility is required for certain base types. 5.2 Angle Mount Bracket Order Code YZU-A YZU-B Description Ceiling Bracket Wall Bracket (To be used with Ceiling Bracket) 5.3 Tester Order Code Description 016091 Portable Flame Detector Test Unit Issued JUN,2011 Page 11 of 11 2011 Hochiki Corporation