Air/water - Heat pumps

Similar documents
NIBE F2026 air/water heat pump. fresh air s free. NIBE F2026. Efficient scroll compressor that operates at temperatures down to -20 C.

Technical data. Danfoss DHP-A

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

Technical description. Atec.

NIBE SPLIT ACVM 270 Air/water heat pump

Advance Split

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump

NIBE F2120 Air/water heat pump

Technical data. Danfoss DHP-L

Planning guide. Atec.

Planning guide. (2010/09) en

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

NIBE F750 A +++ Flexible, high-performance exhaust air heat pump. Exhaust air heat pump

Efficient heating that won t cost the earth

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

WHY A MHI HEAT PUMP?

NIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication

Technical data LA 60TUR+

your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

INSTALLATION AND MAINTENANCE INSTRUCTIONS F F2025

NIBE F470 A + Complete heat pump unit that provides heating, hot water, ventilation, heated supply air and heat recovery. Exhaust air heat pump

Sweden s leading air source heat pump

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Performance Data ADSORPTION CHILLER AGGREGATES & SYSTEM COMPONENTS

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Outline principle. Application Buildings with water-borne heating systems. Alternative

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

High temperature air-to-water heat pumps

Ground source heat pump NIBE F1255

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

Technical data LA 9S-TU

Flexible heating system without limits.

Technical data LA 60TU

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ALFÉA EXCELLIA DUO. more. less AIR TO WATER HEAT PUMP

INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK ELK 15 LEK

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Technical data LA 28TBS

LZT High efficiency air to water heat pumps with E.V.I. compressors

User manual NIBE F2026

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

NIBE SPLIT HBS 05 Air/water heat pump

Apricus Residential Solar Hot Water Systems CLICK TO START

Process glycol chillers

Installation, operating and maintenance ECOLEAN - EAC/EAR

Heated Gas Sampling Probe PSG Basic

PRODUCT DATA SHEETS HEAT PUMPS

Accumulator tank. 1000, 750 and 500 litres Aqualux Teknik Aqualux UB Aqualux 750 CU

LZA High efficiency air to water heat pumps with HP compressor

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

Saving energy comes naturally to us.

Refrigeration Compressed Air Dryer Boreas Variopulse

Installer manual ELK 213 Immersion heater

UNVENTED WATER HEATERS. Water Heater Display Stand

Air/water heat pump NIBE F2120

12 Technicaldata. Dimensions and setting-out coordinates 25-50

REFRIGERATION COMPRESSED AIR DRYER BOREAS VARIOPULSE

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

AQUASNAP JUNIOR 30RHV

air/water heat pump. NIBE F2040 provides

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

TECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

HOT WATER SYSTEMS.

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

NIBE VVM 500 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER NIBE VVM 500. Flexible all-in-one indoor module for heating and hot water.

v SELECTION GUIDELINES

Solar water heating system

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

kw COOLING kw HEATING

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

Equipment Information

Installation and Commissioning Manual

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

NIBE PRODUCT RANGE NIBE PRODUCT RANGE 1

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Heat pumps. for larger residential and commercial installations. Made in Sweden

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

SECTION ELECTRIC WATER HEATERS

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

Teknik Data NIBE F2120 8, 12, 16, 20

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Pool & Spa The Duratech Heat Pumps

HT V2 HT Split

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Transcription:

Air/water - Heat pumps Installation of a NIBE air/water heat pump can lead to your energy consumption for heating being reduced by up to 50%, in comparison to conventional heating systems. Areas of Use You should choose a NIBE air/water heat pump if is not possible to drill in a ground probe or install a surface absorber on the property. This converts the energy of the outside air into heat and creates a comfortable temperature inside the house. Although none of the air/water heat pumps that are available on the market can cover the heating requirements all year round, this type of heat pump does offer economic benefits. In bivalent operation it covers the majority of the heating requirements in a very economical manner, therefore the existing heating system only needs to cover the peak periods. In mono-energetic operation, i.e. air/water heat pump in combination with an immersion heater, the heat pump should cover heating by itself and the immersion heater is only activated during extreme peak periods. Our product range FIGHTER 2005 utilises the energy of the outside air. Therefore, neither a ground probe nor a surface collector is required. In comparison to traditional air/water - heat pumps, FIGHTER 2005 with its two-stage ventilator achieve much greater economy. FIGHTER 2005 is available in sizes 8 and 11 for single phase 230V and size 8, 10 and 14 for three phase 400V. We claim that the FIGHTER 2005 can transform an existing radiator system into an excellent, complete heating system.

Air/water - Heat pumps FIGHTER 2005 FIGHTER 2005 Accessories (see page 7) Control module SMO 10 SMO 10 is an intelligent control unit which together with a FIGHTER 2005 and an existing heating and service water circuit (VPA) forms a complete heat comfort system. Hot water control VST 11 This accessory enables the FIGHTER 2005 to prioritise refilling of hot water in a system with gliding condensation. An accumulator tank, such as a NIBE-VPA, is required for this feature as well as a temperature controller. Components included in delivery FIGHTER 2005 Heat transfer paste Dirt filter R 25 Cable ties Flex-hoses with packing Aluminium tape Adjustable feet with mounting FIGHTER 2005 is a air/water heat pump which has been specifically developed for the climate of Northern Europe. Due to the fact that the heat pump utilises the energy of the outside air, neither a borehole nor an earth collector are required. FIGHTER 2005 is equipped with automatic, two-stage capacity control for the ventilator. Furthermore, the FIGHTER 2005 has been fitted with an electronic control, which controls those functions that are necessary for heat pump operation. FIGHTER 2005 has been specifically developed for operation with radiator heating systems and is therefore particularly suited for use with most heating systems. An advanced control system for optimal control of the heat pump has been incorporated. The FIGHTER 2005 is activated via a starting signal from another control, a return sensor or a thermostat. FIGHTER 2005 can also be controlled by a specially developed control unit, the SMO 10. This activates the additional heating and monitors the switch between heating operation and hot water production. FIGHTER 2005 can also heat up hot water at high outside temperatures effectively, just as it can deliver high performance to the heating system at low outside temperatures. If the outside temperature sinks below the level of the set cut-off temperature, heating must be provided by an external additional heating. FIGHTER 2005 is available in sizes 8 and 11 for single phase 230V and size 8, 10 and 14 for three phase 400V. The materials used in manufacture have been selected with regard to long service life and consideration of the best possible ruggedness for the weather conditions encountered in Northern Europe. FIGHTER 2005 must be placed in the open on a solid base, ideally on a concrete foundation. It should not be positioned near walls which are sensitive to noise, such as close to bedrooms. Defrosting, max./min. cut-off temperature, heat activation for both the compressor crank tub as well as the condensation tub are controlled and furthermore the motor protection and the overpressure switch are monitored. Additionally, the start amount and the length of the respective operation times can be read off.

The built-in control is set up during installation and can then be used as a reference for future maintenance. Otherwise there is no need for the system operator to check the control under normal operating conditions. FIGHTER 2005 is equipped with an electronic return temperature sensor, which limits the temperature of the return. Flow and return sensors are fitted during installation. FIGHTER 2005 can be switched on and off by a signal from a different control unit or via a thermostat, for instance via an SMO 10 (accessory). FIGHTER 2005 is suitable for a wide range of applications, because it allows alternative integrations. Technical Data FIGHTER 2005 Single Phase Single Phase FIGHTER 2005-8 FIGHTER 2005-11 FIGHTER 2005-8 FIGHTER 2005-10 FIGHTER 2005-14 Heat capacity/receptivity* at A2/W35 C ** (kw) 6,9/1,9 9,3/2,6 6,3/1,8 8,3/2,3 11,9/3,5 Heat capacity/receptivity* at A7/W35 C ** (kw) 7,5/1,9 10,6/2,6 7,9/1,8 10,5/2,4 13,8/3,7 Heat capacity/receptivity* at A-7/W45 C ** (kw) 5,3/2,2 6,9/2,8 3,8/1,7 5,8/2,2 7,8/3,2 Heat capacity/receptivity* at A0/W45 C ** (kw) 6,3/2,2 8,5/3,0 5,6/1,9 7,4/2,5 10,5/3,7 Heat capacity/receptivity* at A7/W45 C ** (kw) 7,7/2,3 10,5/3,1 7,4/2,1 9,7/2,7 13,8/4,1 Heat capacity/receptivity* at A-7/W50 C ** (kw) 5,1/2,3 6,9/3,1 3,5/1,7 5,2/2,2 7,2/3,2 Heat capacity/receptivity* at A2/W50 C ** (kw) 6,8/2,5 9,1/3,3 5,9/2,1 7,4/2,6 10,9/3,9 Heat capacity/receptivity* at A7/W50 C ** (kw) 7,5/2,4 10,4/3,4 7,0/2,2 9,3/2,8 13,3/4,3 Heat capacity/receptivity* at A15/W50 C ** (kw) 9,4/2,5 12,6/3,5 9,9/2,0 11,7/3,1 16,3/4,7 Start current (A) 24 33 24 33 26 Motor protection setting (A) 15 21,5 15 21,5 11 Soft start relays are standard Operating voltage 230V + N + PE 50 Hz 3x400V + N + PE 50 Hz Compressor Scroll compressor Piston compressor Nominal heating circuit flow (l/s) 0,17 0,24 0,17 0,24 0,33 Internal pressure drop at nominal heating circuit flow (kpa) 1,1 2,0 1,1 2,0 2,4 Air flow (m3/h) 1320/1750 1320/1750 1320/1750 1320/1750 2250/3050 Nominal ventilator output (W) 155/185 155/185 155/185 155/185 175/190 Protection class IP 24 Maximum exit temperature to the heating circuit ( C) 58 Refrigerant amount (R407C) (kg) 2,1 2,1 2,1 2,1 2,4 Connection heat transfer fluid ext Ø DN 25 External thread of heating circuit connection Ø DN 25 Defrosting system Hot gas defrosting High pressure switch interruption (bar) 27 Low pressure switch interruption (bar) 0,5 Differential gap for high pressure switch (bar) -7 Differential gap for low pressure switch (bar) +1,0 Height with adjustable feet (mm) 1045 Width (mm) 1200 Depth (mm) 500 Net weight (kg) 150 160 150 160 160 * for compressor, ventilator and control. The relation between heating capacity and receptivity must be reduced by approx. 10% during defrosting. ** Outside air temperature/flow temperature

Water heaters for connection to heat pumps VPA VPA is a range of water heaters intended primarily to be connected to heat pumps. They are also suitable for use with other heat sources. VPA is manufactured in three sizes, 200/70, 300/200 and 450/300. The water heater is made up of a hot water tank, encased by a double jacket of sheet steel. The hot water tank is fitted with copper or enamel corrosion protection on the inside. See table. The water heaters are designed and approved to meet current pressure vessel standards. Due to the polyurethane foam insulation the water heater provides excellent thermal insulation. If necessary VPA enables the use of an immersion heater for sensor controlled hot water heating. The cold water supply line must be fitted with safety equipment in accordance with current standards. If the water heaters are heated to more than 65 C, a mixing valve must be fitted. The highest permitted temperature is 100 C. Rated power specifications for the VPA accumulator NL-Zahl 5 4 3 2 1 VPA 200/70 VPA 450/150 VPA 300/200 Technical Data VPA Size 200/70* 300/200** 450/300* Hot water tank capacity litres 205 285 444 Double-jacket tank volume litres 66 194 285 Net weight kg 150 180 285 Height ** mm 1540 1725 2000 Width x Depth/Diameter mm 600 x 610 Ø 725 Ø 800 Heat exchange (55/45 10/45 C) kw 8.2 10.0 14.5 Heat content at 50 C kwh 9.0 12.5 19.1 Corresponding hot water amount (40 C) litres 260 360 560 Maximum cartridge heater length mm 540 580 750 Max. pressure in the double jacket MPa 0,25 0,3 0,25 Max. pressure in hot water tank MPa 1 1 1 kw * Copper ** Copper or enamel *** Without upper connection pipe 5 10 15

Accessories SMO 10 SMO 10 The SMO 10 has been constructed as a control unit so that it can also control not only the automatic mixing mechanism, load monitoring, circulation pumps and sensors, but also compressors and additional electronic equipment in heating and service water systems. Together with a FIGHTER 2005 an existing heating and service water system is converted into a complete and economical heat comfort unit. VST 11 VST 11 This aftermarket equipment enables the FIGHTER 2005 air/water heat pump to prioritise refilling of service water in a system with gliding condensation. An accumulator tank, such as a NIBE-VPA, is required for this feature as well as a temperature controller. When a hot water temperature sensor is connected, the control system for the refilling function is automatically activated. If required the heat pump will prioritise refilling hot water. This refilling will be performed for a maximum of 20 minutes, after which heat for heating will be produced, before it is permissible to switch back to hot water refilling. 7

encompas Warwick Mill Business Centre Warwick Bridge, Carlisle, Cumbria CA4 8RR Tel: 0845 631 3000 Fax: 0845 631 3333 Email: info@encompas.co.uk Web: encompas.co.uk