Conditioning your ambient, maximising your comfort.

Similar documents
Conditioning your ambient, maximising your comfort.

Conditioning your ambient, maximising your comfort.

DryEnergy Hybrid. Purifying your compressed air, increasing your efficiency. refrigeration dryers 0,3-37,5 m 3 /min. Cooling, conditioning, purifying.

Conditioning your ambient, maximising your comfort.

PRODUCT GUIDE Air conditioning

dryer power consumption Why DE Hybrid saves energy Operational savings Seasonal savings ambient temperature débit d air comprimé

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

DRYMODULE HEAT EXCHANGER

PRODUCT GUIDE. Air Conditioning. Conditioning your ambient, maximising your comfort.

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

DEi COMPRESSED AIR & GAS TREATMENT. Purifying your compressed air, increasing your efficiency.

CoolPro Compressed air and gas aftercoolers (air and water-cooled configurations)

Air cooled industrial chillers with Scroll compressors and R410A refrigerant Cooling capacity kw Cooling your industry, optimising your process.

Energy saving refrigeration dryers SCFM. Purifying your compressed air, increasing your efficiency.

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZA High efficiency air to water heat pumps with HP compressor

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

PRODUCT GUIDE

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AQUASNAP JUNIOR 30RHV

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

LZT High efficiency air to water heat pumps with E.V.I. compressors

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

COMPRESSED AIR & GAS TREATMENT

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

HYDRONIC RESIDENTIAL

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

i-nrg 0061m 0061t Reversible heat pump with inverter compressor, total heat recovery, air source for indoor/outdoor installation 16,3 kw PRANA

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Galletti Water chillers and heat pumps catalogue

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Air Cooled Chillers & Heat Pumps WinPACK HE-A

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

CoolPro COMPRESSED AIR & GAS TREATMENT. Purifying your compressed air, increasing your efficiency.

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Advance Split

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Blue Box Epsilon Echos +

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

WZH Ground source heat pumps

ELFOEnergy Duct Inverter

AWR MTD2 XE. Versions

Modular Air-cooled Chillers

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL


CoolPro. Compressed air and gas aftercoolers (air and water-cooled configurations) Purifying your compressed air, increasing your efficiency.

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

Neosys Product catalogue

KELVIN Clim F497. Kelvin air conditioning

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

Process glycol chillers

Do you want a versatile solution

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

Air-to-water scroll chillers

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

H4T R410A. refrigerant

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

kw COOLING kw HEATING

BRAN. Climaveneta Technical Bulletin BRAN_0011_0121_201211_EN ,6-31,3 kw. Reversible unit, air source for outdoor installation

ELFOEnergy Extended Inverter

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

Modular Air Cooled Scroll Chillers

Transcription:

Air to water high efficiency heat pumps with R410A, monoblock and reversible design, compressor and axial fans with DC Inverter motors and variable speed water pump. Conditioning your ambient, maximising your comfort.

NEWGEN Small Inverter The reversible and monoblock heat pumps of the NewGen S.i. range are suitable for outdoor installation and are high efficiency units with single refrigerant circuit for R410A which does not damage the ozone layer. The units are designed for residential and light commercial applications to be connected to fan coils, high efficiency radiators and radiant heating floor systems. RE SID EN TIA L LIG T C O M M E R CIA L IG ENERGY EFFICIENCY CLASS A ROTARY COMPRESSOR PLATE EXCANGER LOW NOISE ECOLOGICAL REFRIGERANT SCROLL COMPRESSOR ELECTRONIC EXPANSION VALVE PLUG & PLAY PASE CUT PUMP DC INVERTER AXIAL FANS DC COMPRESSOR OT WATER FOR EATING AND SANITARY USE NEWGEN SMALL INVERTER, EFFICIENCY AND RELIABILITY FOR AIR CONDITIONING The NEWGEN Si range of products is extremely versatile and designed for heat pump operation for the supplying of hot water for ambient heating and for sanitary use up to +55 C also at the limit external temperature of -15 C. The inverter compressor technology with brushless motor and microprocessor, which allows adjustment without oscillations of the cooling and heating capacity output, combined with the electronic expansion valve, DC invert fans and variable speed pump, optimizes power consumption by reducing the costs of management and ensuring the best operating efficiency of the unit. The hot or chilled water is produced instantaneously, avoiding the use of the storage tank in radiant and fan coil systems. The compact design, the low noise operation and the high level of the units performances are the perfect solution also for problematic building applications. In the NEWGEN Si range of products are available no. 4 models: NGSi 05, NGSi 07, NGSi 10 and NGSi 15 that, with high EER/ESEER and COP values allow to obtain the tax benefits provided for the EU Member States. The unit installation is very simple and requires only electrical and hydraulic connections.

BENEFITS Energy efficiency Class A with high ESEER values; igh thermal comfort; igh energy savings and consequently reduction of management costs; Very low noise operation; Supplying of hot water for heating and sanitary use also at the external limit temperature of -15 C; The unit allows to avoid the use of a buffer tank also with partial thermic loads; Compact design that meets high quality and safety standards; The inverter technology allows the NEWGEN Si units to operate always at optimum power, modulating the compression of the refrigerant gas, the cooling capacity and the power consumption; Refrigerant gas R410A which does not damage the ozone layer; Microprocessor with high computing capacity for a perfect logic control of the electronic expansion valve, the compressor DC Inverter, the fans DC Inverter and the circulation pump; NEWGEN Si units can produce hot water managing also a 3-way valve (optional VD); The NEWGEN Si allows the connection of max 5 units in parallel configuration with the rotation of units in operation and remote control management (optional CR); Connecting multiple units in series, the user can decide which and how many units should be used for the production of domestic hot water; Climatic compensation function. ACCESSORIES CR - Remote control panel to control up to 5 units NGSi, and up to 70 hydronic terminal units in 9 different climatic areas. AG - Anti-vibration rubber mounts to be fixed on the unit base frame. AK - Antifreeze heater version - Antifreeze heater kit (this accessory has to be requested when ordering because it has to be installed during the unit production). The kit includes heaters applied on the user plate exchanger sides which are energized (also when the unit is switch off but powered) when the water temperature falls below 4 C. The plate heat exchanger heaters are switched off when the temperature measured by the outlet water probe exceeds 6 C. The kit also includes a heating cable installed on the base of the NEWGEN Si unit and it is equipped with a built-in thermostat which activates the power supply of the heating cable (also when the unit is switch off but powered) when the outside air temperature falls below 5 C. DSP Kit (Dual Set Point Kit) - This kit, which allows a second working setpoint side system, is used to improve the thermohygrometric comfort and avoid the formation of condensation on the floor prevent the formation of condensation on the floor in the case of floor radiant cooling assisted by fan coil for dehumidification. The kit consists of a humidistat, a socket for DIN rail and a relay. It also required the use of a 3-way diverter valve (not included in this kit, optional VD). VD - 3-way diverter valve. SAS - Sanitary water probe kit. DRAL NET - Control Panel for hydronic terminals units EURUS series. - BUS adapter for hydronic terminals units EURUS series. NS-BOX - Prewired box for hydronic terminals units EURUS series, within device, Dral NET device and air/water probes. STANDARD FEATURES The DC Inverter compressors are rotary hermetic single phase type for models NGSi 05 and 07, twin rotary single phase type for model NGSi 10 and scroll three-phase type for unit NGSi 15. All compressors are equipped with crankcase electric heater, thermal overload protection and anti-vibration rubber mounts; Axial fans with plastic aerofoil blades, with modulating Brushless motor are equipped with a protection mesh and are managed by the microprocessor. The rotor forms a single unit with the fan wheel and incorporates an overload protection device; The user heat exchanger is made of stainless steel braze-welded plates. It is insulated and equipped with a water thermal sensor that in case of need, switches on the water circulator also when the unit is in stand-by, in order to avoid freezing condition; Air side exchanger made by copper pipes and aluminium fins with turbolenced design, low pressure drop and hydrophilic treatment which increases the corrosion protection and also delay the frosting of the exchanger in heat pump mode reducing the number of defrost cycles and consequently obtaining a considerable energy saving; The refrigerant circuit is contained in a separated compartment and it is equipped with: - electronic expansion valve; - 4-ways reverse cycle valve; - high pressure switch control; - liquid separator (only for models NGSi 05, 07 and 10); - liquid receiver; - high and low pressure transducer; - filters; - oil separator, liquid separator and non return valve (only for mod. NGSi 10 and 15). The units NEWGEN Si are covered by hot-galvanised metal sheet, painted with polyurethane powder enamels at 180 C. The colour is Pantone Warm Grey 2C; The hydraulic circuit is equipped with: - water pump with continuous phase cut-off electronic speed control; - expansion vessel; - safety valve; - pressure gauge; - water flow switch; - water pressure gauge; - loading/unloading valve. The electrical board contains all the power, regulation and safety devices; Thermic/acoustic insulation on the compressor and on the piping of the hydraulic circuit; Plastic mesh protection for air side exchanger; The model NGSi 15 (power supply 400/3+N-PE/50z) is equipped with a device to provide protection against phase loss and phase reversal. All compressors are provided with a function to start at low frequency (soft starter) integrated in the logic management of the compressor driver, to decrease the inrush current at the start-up of the compressor; External ambient temperature sensor; Integrated collection tray in the unit base frame equipped with drain connection; On-off control of the integration system electrical heater and integration sanitary heater.

CR REMOTE CONTROL COMBINED WIT DRAL NET AND DEVICES DRAL-NET DRAL-NET DRAL-NET DRAL-NET The remote control CR combined with the control panel Dral NET and adapter can manage up to 70 EURUS hydronic terminal units connected in series. The control panel DRAL NET can be wall installed and allows the modification of the CR set-point ambient temperature of + / - 5 C. The CR remote control, through the components DRAL NET and, is able to manage: speed of the fan motor, 3 ways diverter valve (VD accessory), water and air NTC 10K probes (TAEL accessories). CR REMOTE CONTROL COMBINED WIT NS-BOX DEVICE NS - box electrical supply Valve Fan Water probe Air probe DRAL-NET The accessory NS-Box is equipped with the devices DRAL NET, and the air and water probes (TAEL accessories) already pre-wired and ready to be connected to the EURUS hydronic terminal units. The NS-Box can be installed inside the fan coil casing or close to the recessed or cassette EURUS units. CR panel for remote control of the unit (optional). Anti-freeze kit AK, equipped with a heating cable and electrical resistance (optional). Innovative logic control and DC Inverter technology.

Technical data: 05 07 10 15 Nominal cooling power (1) (min/max) kw 4,71 (2,88 / 4,99) 6,09 (3,73 / 6,95) 9,03 (5,11 / 9,87) 10,82 (7,23 / 11,40) Nominal power input (1) (min/max) kw 1,52 (1,04 / 1,74) 1,96 (1,32 / 2,38) 2,90 (2,08 / 3,50) 3,49 (2,73 / 4,06) E.E.R. (1) W/W 3,10 3,11 3,11 3,10 Cooling E.S.E.E.R. W/W 3,70 3,69 3,80 4,12 Nominal cooling power (2) (min/max) kw 5,81 (3,56 / 6,48) 8,12 (4,97 / 8,80) 11,90 (7,29 / 13,35) 14,07 (9,40 / 14,61) Nominal power input (2) (min/max) kw 1,61 (1,05 / 1,80) 2,13 (1,42 / 2,42) 3,12 (2,32 / 3,69) 3,70 (2,87 / 4,05) E.E.R. (2) W/W 3,80 3,81 3,82 3,80 Nominal heating power (3) (min/max) kw 5,44 (2,82 / 6,20) 7,44 (4,36 / 7,96) 11,98 (6,61 / 12,96) 14,10 (8,55 / 14,99) Nominal power input (3) (min/max) kw 1,70 (1,01 / 2,13) 2,32 (1,48 / 2,73) 3,72 (2,51 / 4,50) 4,35 (3,07 / 5,16) eating C.O.P. (3) W/W 3,20 3,21 3,22 3,24 Nominal heating power (4) (min/max) kw 5,90 (3,25 / 6,70) 8,01 (4,42 / 8,60) 12,58 (6,94 / 14,01) 14,95 (9,07 / 16,20) Nominal power input (4) (min/max) kw 1,44 (0,92 / 1,70) 1,95 (1,21 / 2,18) 3,05 (2,12 / 3,54) 3,64 (2,65 / 4,15) C.O.P. (4) W/W 4,10 4,11 4,12 4,10 Electrical data Power supply V/Ph/z 230 ±10% / 1 / 50 400 ± 10% / 3+N-PE / 50 Max. absorbed power kw 2,81 4,61 5,78 7,93 Compressor Type Rotary DC Inverter Rotary DC Inverter Twin Rotary DC inverter Scroll DC inverter Number 1 1 1 1 Type Motor DC Brushless Number 1 1 2 2 Fan Rated power input kw 0,156 0,188 0,180 ( 2) 0,180 ( 2) Speed r/min 900 900 1000 1000 Max. air flow m 3 /s 1,08 1,63 2,11 2,59 Type Finned coil Condenser Number 1 1 1 1 Rows n 3 3 3 3 Total frontal surface m 2 0,507 0,619 1,292 1,292 Refrigerant Type R410A Refrigerant quantity kg 1,35 1,80 3,25 3,30 Water flow (1) L/s 0,23 0,29 0,43 0,52 ead pressure (1) kpa 48 42 52 72 ydraulic Circuit Max power input of the water pump kw 0,124 0,124 0,165 0,165 Expansion vessel L 2 2 2 2 ydraulic connections inch 1 M 1 M 1 M 1 M Min. volume of water L 18 25 35 45 Noise level Sound power max (5) db(a) 61 64 68 68 Noise pressure Sound pressure max (6) db(a) 48 51 55 55 Dimensions and Weight Dimensions (W D) mm 1134 717 376 1229 861 371 1258 1400 448 1258 1400 448 Opearation weight kg 73 92 147 152 Transportation weight kg 77 96 153 158 All data refers to standard units at the following conditions: (1) Cooling: outdoor air temperature 35 C; inlet/outlet water temperature 12/7 C (2) Cooling: outdoor air temperature 35 C; inlet/outlet water temperature 23/18 C (3) eating: outdoor air temperature 7 C d.b. 6 C w.b.; inlet/outlet water temperature 40/45 C (4) eating: outdoor air temperature 7 C d.b. 6 C w.b.; inlet/outlet water temperature 30/35 C (5) Sound power: determined on the basis of measurements taken in accordance to ISO 3744 (6) Sound pressure level at 1 m obtained in free field over a reflecting plane. Tolerance ± 2 db The sound levels are referred to max operation of the unit. Data refers to the following operating conditions: external air temperature 35 C, inlet/outlet water temperature 7/12 C. Note: Data declared according to UNI EN 14511:2011. The performance data shown in the table refer to units without options and / or accessories and could be subject to change. Attention: for antifreeze unit version, for lowest ambient temperature -5 C, you must add a suitable quantity of antifreeze additives. Overall dimensions: NGSi 05 NGSi 07 NGSi 10-15 W D W D W D Fancoil Radiant heating floor system Functional limits: Chiller mode Outdoor air temperature Min. -10 C Max. +46 C Outlet water temparature Min. +5 C Max. +25 C eatpump mode Outdoor air temperature Min. -15 C Max. +30 C Outlet water temparature Min. +25 C Max. +55 C eatpump mode - Summer functioning (ot Water for Sanitary Use) Outdoor air temperature Min. -15 C Max. +40 C (water temp. max 48 C) Min. -15 C Max. +35 C (water temp. max 55 C) Outlet water temperature Min. +20 C Max. +55 C 3-way diverter valve (optional VD) Water storage 3-way diverter valve tank (optional VD) Sanitary Water Probe (optional SAS) MSI Aqueduct NEWGEN Si

ENERGY FOR TE FUTURE MTA was born over 30 years ago with a clear objective: improving mankind s relationship with two distinct natural resources, air and water, and optimising their transformation into energy sources. And as each application differs, so MTA offers a personalised energy solution perfectly aligned to each individual need. At MTA energy is our business, and improving your relationship with your energy is our aim. www.mta-it.com STRATEGIC DIVERSIFICATION MTA covers three distinct market segments. As well as Air Conditioning solutions, MTA offers products for Industrial Process Cooling, as well as Compressed Air & Gas Treatment solutions. MTA is renowned for the innovation it brings into each of these three sectors; in fact our strategic diversification offers our Customers unique benefits unseen in their individual fields. FAR REACING BUT ALWAYS CLOSE BY MTA is present in over 80 countries worldwide. 7 MTA Sales Companies cover 4 continents. Expert knowledge and an accurate attention to application consultancy and service support guarantees that our Customers can look forward to long term peace of mind and an optimized energy solution. We always remain close to our Customers, so wherever you may be, we are close by. The data contained herein is not binding. With a view to continuous improvement, MTA reserves the right to make changes without prior notice. Please contact our sales office for further information. Reproduction in whole or in part is forbidden. M.T.A. S.p.A. Viale Spagna, 8 ZI 35020 Tribano (PD) - Italy Tel. +39 049 9588611 info@mta-it.com Air conditioning Fax +39 049 9588604 Industrial process cooling Fax +39 049 9588661 Compressed air & gas treatment Fax +39 049 9588612 Milan branch office Viale Gavazzi, 52 20066 Melzo (MI) Tel. +39 02 95738492 MTA worldwide MTA is present in over 80 countries worldwide. For information concerning your nearest MTA representative please contact MTA. International Sales Companies: DNGSI001CB ed. 05/13 substitutes DNGSI001BB Cooling, conditioning, purifying. ISO 9001 BUREAU VERITAS Certification Nº 220817 MTA is ISO9001 certified, a sign of its commitment to complete customer satisfaction. MTA products comply with European safety directives, as recognised by the CE symbol. MTA partecipates in the E.C.C. programme for LCP-P. Certifi ed products are listed on www.euroventcertifi cation.com. Eurovent Certifi cation applied to the units: - Air/Water with cooling capacity up to 600 kw - Water/Water up to 1500 kw Gost Certifi cation MTA Australasia Tel. +61 3 9702 4348 www.mta-au.com MTA France Tel. +33 04 7249 8989 www.mtafrance.fr MTA Germany Tel. +49 2157 12402-0 www.mta.de MTA Romania Tel. +40 723 022 023 www.mta-it.ro MTA Spain Tel. +34 938 281 790 www.novair-mta.com MTA UK Tel. +44 01702 217878 www.mta-uk.co.uk MTA USA Tel. +1 716 693 8651 www.mta-usa.com