User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

Similar documents
User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

Installation, Operating and Servicing Instructions

USER INSTRUCTION MANUAL. Autofill Water Boiler

INSTALLATION AND USER INSTRUCTIONS

The Professional s Choice

The Professional s Choice

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

Installation, Operating and Servicing Instructions. Lynx 400 Electric Salamander Grill LGT

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions. Silverlink 600 Electric Pasta Boilers PB33, PB66

Installation, Operating and Servicing Instructions. Opus 700 Electric Salamander Grill OE7304

INSTALLATION AND USER INSTRUCTIONS

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions. Lynx 400 Heavy-Duty Contact Grill GG1, GG1R, GG1P

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions. Seal Heated Display Bars HB1, HB2, HB3, HB4, LD2, LD3, LD4

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions. Opus 800 Electric Cook & Hold Salamander OE8306

Installation, Operating and Servicing Instructions

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

The Professional s Choice

INSTALLATION AND USER INSTRUCTIONS COUNTERTOP AND FREE STANDING FRYERS

Autofill counter top water boiler

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

User and Installation Instructions. Opus 700 Electric Wet Well Bain Marie OE7601 IS195 ECN2396

User and Installation Instructions. Opus 700 Electric Salamander Grill OE7304 IS318 ECN3011

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

Autofill Wall Mount Boilers

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

INSTALLATION, USER AND SERVICING INSTRUCTIONS FOR ESLR9C OVEN RANGE

LT4X AND LT6X Electric Slot Toasters

Autofill Countertop Boilers

MIX Boiler & Font Range Service Manual

ELECTRIC WATER BOILER

USER INSTRUCTION MANUAL. Autofill Wall Mount Boilers /12/14

User, Installation and Servicing Instructions. Silverlink 600 Gas Griddles GS4 and GS7 IS212 ECN3592

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Marco Beverage Systems Ltd. INSTRUCTIONS FOR MODELS

CONTENT PAGE INFORMATION INSTALLATION BREWER SETUP BREWING CLEANING KEY BREWER GRINDER MANUAL MODE DILUTION GRINDER MODE PACKS MODE

User, Installation and Servicing Instructions. Panther Hot Cupboards GB2, GB3, GBM2, GBM3, GX2, GX3, GM2, GM3 IS70 ECN 1755

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Autofill Wall Mount Boilers

Installation, Operating and Servicing Instructions

AQUARIUS 45 MARINE SERVICE MANUAL

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

Ecoboiler SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

EcoSmart boiler SERVICE MANUAL

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

T5 ( ) T10 ( ) PB5 ( ) PB10

Hot Water Urns v3.0. all models. Helpline. instructions.indd 1 02/06/ :50

OPUS Electric Chip Scuttle OE7109 USER /INSTALLATION INSTRUCTIONS

Mix Boiler & Font Range ( #, #, #, , )

Please read and keep these instructions for future use

One Cup. Please read and keep these instructions for future use

Calomax Limited Lupton Avenue, Leeds LS9 7DD Tel Fax

4L Instant Water Boiler Instructions for Use

Marco Beverage Systems Ltd.

IS09 ECN2087. EB3, EB4 & EB6 Automatic Fill Water Boilers INSTALLATION, USER & SERVICING INSTRUCTIONS

BRITA Filter Jug Kettle

The Classeq under counter range

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

Actual product may differ from the one illustrated

User and Installation Instructions. Seal Refrigerated Merchandisers

Paper Shredder. Installation & User Instructions Please keep for future reference 913/0153

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

IDL/ De Longhi Appliances via Seitz, Treviso Italia

INSTRUCTION MANUAL KETTLE

INSTRUCTIONS AND WARRANTY

INSTRUCTIONS MODEL: MFBU WET WELL BAIN MARIE

User Instruction Manual

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

PLATE DISPENSER MODEL NUMBERS MPN10000 MPN10500 MPN20000 MPN20500

Diamond Cut 360 Cordless Jug Kettle Cool Touch Plastic

Calomax Limited Lupton Avenue, Leeds LS9 7DD Tel Fax

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

Mira Sport Max with Airboost

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

OG7302 Salamander Grill

HINTS AND TIPS Cleaning and maintenance HELPLINE

OE7008 & OE7010 Electric Oven Ranges

ProAction. Paper Shredder. Installation & User Instructions Please keep for future reference 903/1537

IMPORTANT SAFEGUARDS Ensure that your mains supply voltage is the same as that marked on the underside of your kettle.

User Guide & Warranty Information

WATER KETTLE INSTRUCTION MANUAL

Zip Autoboil Installation and Operating Instructions

INSTANTANEOUS ELECTRIC SHOWER

Zen Boiling Tap Range

Transcription:

User and Installation Instructions Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

Dear Customer Thank you for purchasing this Lincat product. With correct use and careful maintenance as described in these instructions, your Lincat product will give years of trouble free use. We produce over 450 different items of catering equipment and our range is constantly being extended and improved. Find out more about Lincat products from your local distributor or direct from us. CONTENTS CONTENTS...2 SAFETY INFORMATION...3 DELIVERY CHECKLIST...3 TECHNICAL SPECIFICATION...4 ACCESSORIES...4 INSTALLATION...4 CLEANING...8 MAINTENANCE...9 DIAGNOSTIC MESSAGES...11 SERVICE INFORMATION...11 GUARANTEE...12 IS339 ECN3539 2

SAFETY INFORMATION To prevent injury to yourself or your staff, and to avoid damaging the product, please read and follow the safety precautions below before setting up and using the unit: Remove all plastic coatings and clean the unit before use. Ensure that the electrical supply cable is not damaged. If it is, it must be replaced by Lincat Ltd or by qualified personnel. Always disconnect the unit from the electricity supply before servicing. The unit must be earthed. Do not try to modify this unit. Never clean the unit with a water jet or steam cleaner. Inform staff that the surfaces will become hot. Keep these instructions in a safe place near the unit for future reference. DELIVERY CHECKLIST If an item is missing please contact your dealer immediately. Electric water boiler Drip tray and insert White water inlet hose with ¾ BSP connection User instructions Guarantee card Filterflow badge Sample of descaling agent IS339 ECN3539 3

TECHNICAL SPECIFICATION Model EB3F EB4F EB6F EB6TF Width mm 290 290 455 455 Depth mm 465 465 465 465 Height mm 655 655 655 655 Power Rating kw 3.0 4.5 6.0 6.0 Net weight net kg 13 13 17 17 Ambient temperature o C 5 to 30 Water inlet pressure Bar 1 to 8 ACCESSORIES Wall mounting kit for EB3F, EB4F Wall mounting kit for EB6F, EB6TF Replacement filter cartridge BR49 BR50 FC02 INSTALLATION The boiler must be installed on a horizontal surface in a location where it can be supervised by trained personnel. Inform all users that the surfaces may become hot. For safety regulations the plug or means of disconnection must always be accessible. Connecting to the electricity and water and waste supplies The boiler must be earthed. Check that the voltage of your electricity supply corresponds to the voltage shown on the serial plate. EB3F The boiler is supplied with a 13 amp plug. If replacing the plug, connect the terminals as follows: Green and yellow wire Earth E Blue wire Neutral N Brown wire Live L For safety regulations the plug or means of disconnection must always be accessible. IS339 ECN3539 4

EB4F The boiler is supplied with a bulkhead cable connector and must be fitted with 2.5mm 2 3-core cable.the supply end of the cable must be fitted with an allpole disconnection isolator switch with a minimum of 3mm contact separation. For safety regulations the means of disconnection must always be accessible. EB6F / EB6TF The boiler is supplied with a bulkhead cable connector and must be fitted with 4mm 2 single or 3-phase cable. The supply end of the cable must be fitted with an easily accessible all-pole disconnection isolator switch with a minimum of 3mm contact separation. For safety regulations the means of disconnection must always be accessible. Water supply and waste connection: all models Connect the supplied white water inlet hose to the inlet connection point on the base of the boiler and the other end to the mains water supply via an accessible isolating tap with a ¾ BSP thread. The drip tray has a large capacity but if required it can be connected to a waste water outlet using a ½ bulkhead connector (not supplied) If cables are required to exit at either side of the boiler the thinner section between the moulded feet may be cut away using a junior hacksaw. IS339 ECN3539 5

1 Control panel 2 Water dispensing tap 3 Filter cartridge 4 Drip tray and cover 5 Serial plate IS339 ECN3539 6

OPERATION First use 1 Switch on the mains water supply and the electricity supply 2 Leave the boiler for 30 minutes to allow it to fill completely 3 Drain off approximately 5 litres of water to remove any loose carbon particles from the filter. Regular operation The boiler starts automatically when the mains water supply is turned on. After a short delay it fills with water and heats up. During the heating cycle small quantities of water are added to ensure that hot water is always available at the tap. The water temperature, screen backlight and screen contrast can be adjusted as required. The boiler is designed to be left permanently switched on: it is only necessary to turn it off for descaling or maintenance. Changing water temperature, screen backlight and contrast. 1 Turn power off and on again. The Filter Flow screen is displayed Power / Standby button Fn (Function) button 2 Press and hold the power button until the software version is displayed. Press Fn and the temperature will be displayed 3 Press the power button to cycle through the values 70 to 96 deg C. Press the Fn button to select the required value 4 The backlight adjustment screen is displayed next 5 Press the power button to cycle through the values 1 to 25. Press the Fn button to select the required value 6 The contrast adjustment screen is displayed next IS339 ECN3539 7

7 Press the power button to cycle through the values 35 to 60. Press the Fn button to select the required value 8 Press the power button to exit. Standby If the boiler is to be left unused for a long period, the element can be turned off by pressing the power button. Filter replacement The FILTER display shows the estimated remaining life in the current filter cartridge. When the filter needs replacing, a reminder message is displayed. This is followed by the change filter screen. The boiler can be used without a filter but scale may build up more quickly and water taste may be affected. Replace the filter as follows: 1 Twist the base of the filter 90 degrees to the left and carefully lower the filter cartridge out of the unit. It will contain a small amount of water 2 Remove the black cap and place on the new filter 3 Insert the filter fully into its recess and twist to the right to lock in place 4 Press and hold the Fn button for 5 seconds to reset the filter life monitor 5 Drain off approximately 5 litres of water to remove any loose carbon particles from the filter IS339 ECN3539 8

CLEANING Clean the external surfaces of the unit regularly to maintain hygiene. Empty the drip tray regularly. Wipe the dispensing tap daily to remove any limescale deposits and check that the water outlet is clear. Wipe the unit down with a damp soft cloth. Do not allow excess water to run into the unit. Do not use abrasive creams or scourers. MAINTENANCE Drip Tray: Filter: Slide tray out to remove and empty Twist to the left and remove. See section on filter replacement. Descaling The descaling procedure must be performed by trained personnel as it requires the removal of panels from the boiler and access to live electrical components. The boiler should be descaled regularly to maintain efficient operation and water quality. The frequency depends on the hardness of the local water and timely replacement of the filter. The boiler is best descaled at the end of the working day to allow the descaling agent several hours to work. Lincat recommends its own descaling agent, available from Lincat spares department, part code MS19. 1 Wear protective clothing 2 Isolate the boiler from the electricity supply 3 Turn off the power and let the water cool to approximately 60ºC to avoid injury 4 Using a 3mm Allen key, remove the screw on the top of the boiler 5 Remove the insulation on top of the tank, then unscrew and remove the tank lid 6 Add the descaling agent a little at a time as some types can cause hot water to erupt. Always follow the manufacturer s instructions 7 Replace the tank lid and outer lid, and attach an Out of Use notice to the boiler to prevent use during descaling 8 Turn on the electricity and allow the boiler to heat and run normally for approximately 30 minutes 9 Isolate the boiler and allow the water to cool IS339 ECN3539 9

10 Remove the outer and tank lids again and inspect the tank and level sensor housings for scale deposits. If necessary repeat the descaling process 11 Drain and flush all descaling agent from the tank completely as follows i ii iii iv Remove the two screws behind the drip tray that secure the lower front panel Connect a hose from the overflow pipe to a bucket and turn the service valve to drain the remainder of the water from the tank Flush out the tank with clean water When empty shut the valve and replace the cover 12 Replace the tank lid, ensuring that the gasket is sealing the top of the tank correctly 13 Fit the outer lid and turn on the boiler. IS339 ECN3539 10

DIAGNOSTIC MESSAGES The control panel displays messages and information that can help with fault diagnosis. Before calling for service, draw off a litre of water, clear the fault code by pressing the Fn button and turn the boiler off and on again at the mains supply. If the fault persists call service for advice. Message Displayed Possible cause Corrective action Scale on level sensors Boiler overfilling Descale. Check water inlet valve Water turned off Inlet hose bent or blocked Water pressure too high or low Drain valve open Check water supply and drain valve. Call service if fault persists Boil-dry / overheat protector tripped Temperature sensor fault Element failed PCB fault Faulty / loose connection Check connections. Call service if fault persists Temperature set too high Temperature sensor fault Boiler not filling Excessive scale in tank PCB fault Reduce temperature setting and try again. Call service if fault persists Temperature sensor fault Call service IS339 ECN3539 11

SERVICE INFORMATION For help with the installation, maintenance and use of your Lincat equipment, please contact our service department: UK: 01522 875520 All service work, other than routine cleaning should be carried out by one of our authorised service agents. We cannot accept responsibility for work carried out by other persons. To ensure your service enquiry is handled as efficiently as possible, please tell us: Brief details of the problem Product code Type number } From serial plate (beside dispensing tap) Serial number Lincat reserve the right to carry out any work under warranty during normal working hours, Monday to Friday, 08:30 am to 17:00 pm. GUARANTEE This unit carries a comprehensive UK twelve-month warranty. The guarantee is in addition to, and does not diminish your statutory or legal rights. The guarantee does not cover: Accidental damage, misuse or use not in accordance with the instructions in these instructions Consumable items Damage due to incorrect installation, modification, unauthorised service work or damage due to scale The manufacturer disclaims any liability for incidental, or consequential damages IS339 ECN3539 12

This page intentionally left blank IS339 ECN3539 13