AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Similar documents
I.F.U Re/Processing Reusable Medical Devices

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

REUSABLE ENDOSCOPY INSTRUMENTS (thermo resistant)

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

Processing Instructions. Cleaning so easy.

Processing instructions for the Ligamys suture forceps

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

RAP-hip Hip stem extraction set

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

Operating / User Manual

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

Instructions for Use Spinal Punches IFU

AS Medizintechnik GmbH Sattlerstraße Tuttlingen Germany

O-PEP Hygiene-Beileger

Classification of Instruments -

Cleaning & Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Cleaning and Sterilisation for Burs, accessories and filling material

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Cleaning and Sterilization for Instruments & Posts

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Aesculap Implant Systems

RECOMMENDATIONS FOR CLEANING DEVICES

Instruction of use. Flexible Naso-Pharyngo- Laryngofiberscope,

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

CLEANING INSTRUCTIONS

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

Instructions for Use (GA16)

Recommendations for cleaning, decontamination and sterilisation. devices

Reusable Laryngoscope Blades and Handles

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

THE BASICS OF DECONTAMINATION

Aesculap Implant Systems

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

Caution: Federal U.S. law restricts this device to sale by or on the order of a physician.

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

2015 Myco Industries, Inc Fax:

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

PERFORM Operating Document

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

Elaborating of a Reprocessing Instruction According to ISO Klaus Roth

V. Mueller. V. Mueller Reusable Devices: Cleaning and Sterilization Guide USA. Rx Only

Data of 57 hospitals** Estimated for England and Wales

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

Manual. Reprocessing. RICHARD WOLF Heat-Stable Instruments. GA-J020 / en / V17.0 / PDI

Flexible Nasopharyngoscope. Operator Manual. Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc.

Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods th July 2012

STERITITE INSTRUCTIONS FOR USE

Guidelines for Cleaning, Disinfecting and Sterilizing Medela Healthcare Products REPROCESSING GUIDE. Precious life Progressive care

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

Table of Contents. English

LipoCollector II Operating Instructions

Guidelines for cleaning, disinfection, and sterilization of the biopsy adaptor, water bag, coupler, and magnetic sensor securing adaptor

Operator s Guide. Autoclavable Internal Handles with Integrated Paddles Rev. M

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Reprocessing of surgical instruments

Additionally, consider the legal provisions valid for your country as well as to the hygienic instructions of the doctor s practice or hospital.

FLASH PAK STERILIZATION CONTAINER SYSTEM

INSTRUCTIONS EVIS EXERA GASTROINTESTINAL VIDEOSCOPE

When you sterilize an instrument set, you know what the standards are.

Clinical Use Only. ResMed HumidAire 2i. Disinfection and Sterilisation Guide. English

Instructions for Cleaning, Sterilization, Inspection and Maintenance. of Trauma & Extremities Medical Devices

ASPIRE Laboratory Aspirator

IMPORTANT INFORMATION ON THE DEPUY SYNTHES

Fujinon Medical Hygiene. Reprocessing of flexible endoscopes and endoscopic accessories.

PICNet CONFERENCE 2013

MODEL 7000 SUCTION UNIT

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

STERIS Instrument Cleaning Chemistries

Instructions for Use: Endoplus Modular Handle Assemblies, Multi-Use Scissors Inserts, Reusable Inserts

X99 Series. Dental Handpiece. Instruction For Use

The Principles, The Process, and The Results:

idrive Ultra Powered Stapling System

H5i disinfection guide

Important information

Operator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013

Operating Instructions. G 7782 CD Washer/Disinfector. To prevent accidents and machine damage, read these instructions before installation or use.

Instructions for use Vacuum regulation valve with water trap

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

Fiona Collins Liliana Donatelli Andrew Smith

Operating instructions Washer-disinfector G 7824

SteelcoSure Independent performance verification of your equipment and processes

Basic SURGICAL SUCTION PUMP. EN Instructions for use

JT-SB116JH-G-NA JT-SB116JH-W-NA

ENDOILLUMINATION. in accordance with EN ISO 17664

Instructions for Use: Fiberscope and LED Light Source

Transcription:

s 65-201-00-65-202-00 01 Stopcock left 02 Spring Cap 03 Cannula CLEANING / STERILIZATION Immediately after use the instruments have to be soaked in a combined disinfection and cleaning solution in order to prevent operation residues to dry on and a transmission of germs in the endoscopy rooms. Cleaning agents and disinfection solution have to match. Please observe the respective guidelines for these substances. The instruments have to undergo a thorough cleaning process, because detergents, blood, pus, and protein residues may influence the disinfection and sterilization procedure. After the cleaning procedure, all moving parts have to be oiled. All revolving stop cocks and pistons have to be lubricated. Proper care and service are necessary for the safe use of medical products. We therefore recommend a thorough check of function, completeness and damages (especially porous and cracked rubber and plastic parts), sharp edges and rough surfaces. Field of use - Irrigation Cannula The term arthroscopy derives from the classical Greek language. Thereby, the term arthros refers to the joint, scopy means to look. Arthroscopy is generally used for examinations of injuries of the knee, shoulder, hand and ankle joints as well as unclear constant joint pains. Our versions differ in diameter and length. We adapt them so that they are compatible with the common optics of various manufacturers. Disassembly of irrigation Cannula Please, disassemble only pre-washed instruments. Unscrew the spring cap 02 and remove valve 01. The irrigation Cannula is now completely disassembled. Assembly of irrigation Cannula When inserting the valve 01 into the stopcock, please make sure that the guiding pin runs in the guidance and that the lever (in open position) shows to the opening. Screw the valve 01 onto the spring cap 02.Check the instrument for proper function. The irrigation Cannula is now completely assembled. Page 1 of 8

1 Overview of processing steps Reprocessing steps Processing medium Reusable surgical instruments Pre-cleaning directly after use Decontamination Wet Dry Soak in cleaning and disinfection solution and rinse with water Wipe with damp cloth or with cleaning and disinfection solution Pre-cleaning # See section 4 Pre-cleaning on page <?>. Endoscopes (thermostable) Endoscopes (thermolabile) Instruments for use with endoscopes Reusable containers Elastic products 1 HF cables and tool holders Cleaning # Manual 1 Mechanical 1 Ultrasound - - - - - Alkaline cleaning agent 5 ph 9-12 3 Acidic cleaning agent 5 3 Neutral cleaning agent 5 Enzyme cleaning agent 5 - - 3 3 3 3 3 3 3 3 Rinsing Demineralized water Disinfection Chemical max. 60 C - 3 3 Thermal max. 93 C - Drying Temperature 50 60 C / >10 min. Maintenance 6 See section 6 Cleaning on page 4 Sterilization Moist heat autoclave pre-vacuum 134-137 C. 134-137 C - 134-137 C. 134-137 C 134-137 C 134-137 C 1 Deionized water is recommended for the final rinse. 2 Rubber and/or latex, silicone elastomers. 3 Does not apply to (anodized) aluminum alloys. 4 Not suitable for ultrasound-assisted cleaning. 5 Follow usage instructions supplied with the cleaning agent. 6 For detailed information, see section 7 Maintenance on page 6. LL Information about reprocessing is provided by the Robert Koch Institute (RKI) and AKI, the working group for instrument reprocessing: RKI: Anforderungen an die Hygiene bei der Aufbereitung von Medizinprodukten (hygiene requirements for the reprocessing of medical products) (published Nov. 1, 2011, www.rki.de) AKI: Instrumentenaufbereitung richtig gemacht (instrument reprocessing the right way) (8th edition, www.a-k-i.org) Symbol Meaning rocess with validated microbiological effectiveness and verified material compatibility Process with verified material compatibility - Incompatible 0 Contact the manufacturer for more information # For detailed information, see section 6 Cleaning on page 5. Low temperature (steam formaldehyde) Ethylene oxide - Hot air - - - - - - - Liquid sterilant Gas plasma - - - - - - - Page 2 of 8

2 Safety and responsibility Before preparing instruments Read and follow the preparation instructions. Keep these instructions in a place where they can be easily seen for reference at a later date. AMNOTEC International Medical GmbH does not assume any liability for damage as a result of incorrect preparation and care. The user is responsible for validating alternative cleaning and sterilisation methods. Risk of infection Prepare the instrument before use. Prepare the instrument before returning it to the manufacturer. Follow the instructions for use of the cleaning agents and disinfectants used as well as of the cleaning and sterilisation devices used. Wear gloves during preparation. Discard disposable components after initial use. Risk of injury Do not use damaged instruments and do not repair. Only use original accessories. 3 Explanation of symbols DANGER Indicates a danger which results in death or serious injury if not avoided. Indicates a danger which can result in death or serious injury if not avoided. CAUTION Indicates a danger which can result in injuries if not avoided. Indicates measures in order to prevent damage to property. This symbol provides information in order to facilitate handling of the device. Here measures are given which must be followed to prevent a risk. You are requested to take action here. You find out the result of the action taken here. This symbol indicates additional information. TIP: The TIP provides useful advice on handling the instrument. 4 Preparing decontamination To prevent surgical residue from drying on, the following steps must be performed directly after surgery. Page 3 of 8

CAUTION Risk of infection due to the fixation of residues. Rinse the instrument with cold water. Remove coarse dirt with cold water. Rinse out cavities with cold water. If it is not possible to rinse with cold water, the instrument must be wrapped in a moist cloth to prevent any residues from drying on. Always transport the instrument to the preparation site in a closed container to prevent product damage and contamination of the environment. 5 Pre-cleaning Pre-cleaning prevents germs from spreading and surgical residue from drying on. It must therefore be carried out directly after surgery. Pre-cleaning was validated with the cleaning agent Neodisher FA from Dr. Weigert: Cleaning Dosage ph value Alkaline 0.5 % 11.4-11.9 (diluted) Risk of infection and pyrogenicity if unsuitable cleaning agents are used. Do not use fixing agents. Do not rinse with hot water. Avoid damaging product. Do not use abrasive brushes or scourers. Only use suitable cleaning agents. Use disinfectant with corrosion protection. Rinse the instrument below the water level. This prevents the spread of germs. Place the instrument in cold water: > 5 min. Dismantle the instrument (if possible). See instrument s Instructions for Use. Open stop cocks (if relevant). TIP: Remove caked-on tissue residues with a plastic brush. Brush the outside and inside under cold water with a round brush until no more residue is visible. Rinse out cavities, drill holes and threads (if relevant) with a cleaning gun: > 10 s at 3-5 bar. Remove from the water bath and rinse off with cold water. Immerse in combined cleaning and disinfectant solution until subsequent cleaning to prevent any residue from drying on. Page 4 of 8

6 Cleaning Unless stated otherwise in the instrument s Instructions for Use, cleaning is performed with the instrument disassembled. Cleaning was validated with the cleaning agent Neodisher FA from Dr. Weigert: Cleaning Dosage ph value Alkaline 0.5 % 11.4-11.9 (diluted) Risk of infection due to insufficientpreparation. Remove protective caps (if relevant). Avoid damaging product. Only use suitable cleaning agents. Avoid contact with hydrogen peroxide (H2O2). Do not use abrasive brushes or scourers. Choose between manual and mechanical cleaning. 6.1 Manual Rinse the instrument below the water level. This prevents the spread of germs. Open stop cocks (if relevant). Additionally clean the components in an ultrasonic bath with the following settings: Temperature Frequency Duration 40 C 35-45 khz > 4 min Turn and move the components several times during cleaning in the ultrasonic bath. Clean the inner chambers with a cleaning brush below water. Rinse through the inner chambers with a cleaning agent: 3-20 min. at 45-85 C IImmerse the instrument in cold demineralised water and rinse through the cavities several times with demineralised water. Disinfect and dry Disinfection was validated with the disinfectant Cidex OPA from Johnson & Johnson: Cleaning Dosage ph value Alkaline 0.5 % 7.2-7.8 (diluted) Disinfect with disinfectant. See manufacturer s Instructions for Use. Dry on the inside and outside: >10 min at 50-100 C And/or: Blow through with sterile compressed air. 6.2 Mechanical Page 5 of 8

Mechanical cleaning was validated with the cleaning device 7735 CD and 7736 CD from Miele Proper cleaning depends on the right cleaning program. Compare the cleaning program with that of your cleaning system and save where necessary: 1. Pre-rinse with cold water: 1 min. 2. Empty. 3. Repeated pre-rinsing with cold water: 3 min. 4. Empty. 5. Clean with 0.5% mild alkaline cleaning agent: 5 min. at 45-55 C 6. Empty. 7. Neutralise with warm tap water and a suitable neutraliser: 3 min. at > 40 C 8. Empty. 9. Rinse with warm tap water: 2 min. at > 40 C 10. Empty. 11. Disinfect: Observe the national requirements as regards the A0 value (see ISO 15883) 12. Dry: 15-25 min. at 90-110 C Open stop cocks (if relevant). Place instruments in a sieve tray on the MIC cleaning device trolley so that the cleaning agent can reach all inner and outer surfaces. Connect the flush port (if relevant) to the MIC cleaning device trolley. Start the cleaning program. If necessary, additionally dry the instrument after cleaning with sterile compressed air. Additionally clean the components in an ultrasonic bath with the following settings: Temperature Frequency Duration 40 C 35-45 khz > 4 min Turn the components over several times during cleaning in the ultrasonic bath. 7 Care Caring for the instruments properly will lengthen their service life and should therefore be carried out after every cleaning process. Risk of injury from faulty or damaged components Do not reuse faulty or damaged instruments. Check to ensure they are clean and, necessary, repeat cleaning. Check for damage (e.g., sharp edges, rough surfaces). Replace brittle and cracked seals (if relevant). Lubricate moving parts (e.g., joints, rotating stop cocks) with medical oil. Remove any excess oil. Do not use damaged components. Assemble instruments and check to ensure they are in perfect working order. See instrument s Instructions for Use. 8 Wipe-down disinfection Wipe-down disinfection serves to reduce the germs on the surfaces of devices. Wipe-down disinfection was validated with the wipe-down disinfectant Neoform MED AF from Dr. Weigert: Page 6 of 8

Dosage Exposure time 1% 15 min. 2% 5 min. Avoid damaging product. Do not use abrasive brushes or scourers. Use a suitable disinfectant. Wipe down the device surface with a wipe-down disinfectant. 9 Packaging The instrument must be packaged appropriately to prevent recontamination with the environment. Package the instrument to comply with ISO 11607 and EN 868. 10 Sterilising Unless stated otherwise in the instrument s Instructions for Use, sterilisation is performed with the instrument assembled. You will find detailed information on the assembly of the instrument in the latter s Instructions for Use. Sterilisation was validated with the sterilisation device Selectomat S 3000 from MMM Group and Variocalv 400 E from Fisher Scientific. Avoid damaging product. Observe the device s maximum load. See manufacturer s Instructions for Use. Risk of infection due to excessively short sterilisation time. If there is a suspicion of prions and Creutzfeldt-Jakob disease, the sterilisation time must be 18 min. The sterilisation time is between 4-30 min. The following countries make different stipulations which must be observed: Country France Switzerland Sterilisation time 18 min. 18 min. Open stop cocks (if relevant). Place in the sterilisation device so that the components are not touching each other and the steam can circulate freely. Select sterilisation parameters: Temperature Pressure Duration 134-137 C 3 bar 44 psi See details in this chapter. Page 7 of 8

Start the sterilisation process. 11 Storing sterile devices To prevent reducing durability and forfeiting any resistance to bacteria, the following storage conditions must be observed: Store the sterile device sealed in a clean, dust-free and dry sterile container. Store the sterile container in a clean and dry environment with controlled humidity at room temperature. Do not store the sterile container in the vicinity of aggressive substances (e.g., alcohols, acids, bases, solvents and disinfectants). Also observe your internal storage standards for sterile devices. 12 Disposal Environmentally sound disposal enables valuable raw materials to be recycled. Dispose of the device in an environmentally friendly manner in accordance with the valid hospital guidelines. 13 Information on validation The following materials and machines were used for validation: Cleaning agent: Neodisher FA from Dr. Weigert. Cleaning and disinfection device: 7735 CD and 7736 CD from Miele. Sterilisation device: Selectomat S 3000 from MMM Group and Variocalv 400 E from Fisher Scientific Sterilizing agent: Moist heat AS MEDIZINTECHNIK GMBH DOES NOT ACCEPT RESPONSIBILITY IF THIS CUSTOMER INFORMATION HAS BEEN VIOLATED PROVABLY. Page 8 of 8