Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

Similar documents
Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Unvented water heater

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

Unvented water heater

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Regulations, Legislation and Byelaws

Installation Manual EXCELSIOR Unvented Water Heater

Unvented Direct & Indirect Hot Water Cylinders (400L L)

Unvented Hot Water Storage Cylinders Installation and Maintenance Instruction Manual

MEGAFLO Eco Plus Solar Unvented Hot Water Cylinders 400L -570L

Quantum. Installation, User and Service Manual. Hot Spring

KYROS INSTALLATION MANUAL KYROS. Digital Electric Water Heater Wall-hung Unvented

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Instructions for Use Installation and Servicing

Link-Up. Solid Fuel Association Guide to Central Heating.

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Unvented Direct & Indirect Hot Water Cylinders (400L L)

WATER HEATERS INSTALLATION MANUAL

UNVENTED MAINS PRESSURE SOLAR WATER HEATERS 210, 250 AND 300 LITRE CAPACITY INDIRECT MODELS INSTALLATION AND SERVICING INSTRUCTIONS

Technical and Installation manual All Models

EPU - WM30 EPU - WM 50 EPU - WM100

Instructions for use Installation and Servicing. Unvented Hot Water Cylinders/ Hydracyl

PremierPlus Unvented Hot Water Cylinder Installation and User Manual

Design, Installation, User & Servicing Instructions

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

Megaflo Eco Plus Unvented Indirect Hot Water Cylinders 800L L

Megaflo Eco Unvented Direct & Indirect Hot Water Cylinders

Unvented Hot Water Storage Cylinders

Megaflo Eco Slimline Unvented Direct & Indirect Hot Water Cylinders 100L - 200L

Zircon Installation Manual

StainlessLite HP. Design, Installation & Servicing Instructions. Unvented cylinders specifically designed to work with a heat pump

Megaflo Eco SystemReady Unvented Indirect Hot Water Cylinders

Design, Installation, User & Servicing Instructions

Water Heating UK 14 th May 2016

Megaflo Eco Solar PV Ready Unvented Direct & Indirect Hot Water Cylinders 170L - 300L

Megaflo Eco Unvented Direct & Indirect Solar Hot Water Cylinders

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Installation and Servicing Instructions

Instructions for Installation, Servicing and Use

MULTIPOINT 30 & 50 Litre

Baxi Maxflow Combi FS

Instructions for Installation, Servicing and Use

Alpha CombiMax 350 and 600

Schuco SS-TC/SC Cylinders

SEALED THERMAL STORE

Unvented Direct & Indirect Hot Water Cylinders

Unvented Hot Water Criteria

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

UK-specific appendix to Installation instructions DHP-A DHP-A Opti DHP-AQ Maxi DHP-H DHP-H Opti DHP-H Opti Pro DHP-L DHP-L Opti DHP-L Opti Pro

STAINLESSLITE PLUS INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE HOT WATER STORAGE

Advance Stainless Steel Unvented Hot Water Cylinders for Heat Pump Systems. Installation and Commissioning Manual

Baxi Maxflow Combi WM

MULTIPOINT SS H 50/80 & 100

Powerflow Unvented water heater

APP STAINLESS UNVENTED HORIZONTAL HOT WATER CYLINDERS

Unvented water heating

smart line E SLE

MAX O GAZ. Condensing water heater TECHNICAL MANUAL

T E C H C A L EBS-1 T High technology heating

WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7

Installation and Servicing Instructions. Alpha CD50

IMPORTANT: PLEASE READ ALL THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION

StainlessLite. Design, Installation & Servicing Instructions. Unvented mains pressure water storage in Duplex stainless steel

Flomaster. Unvented Hot Water Cylinders INSTALLATION INSTRUCTIONS FOR COPPERFORM FLOMASTER UNVENTED CYLINDERS: DIRECT, INDIRECT AND SOLAR MODELS.

Introduction. General. Other regulations. British Standards and European Technical Specifications

Assessment Schedule - TS.6

MEGAFLO Eco SystemFit Unvented Indirect Hot Water Cylinders

R e n e w a b l e s. Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions. Issue 14 May 2011 Part No.

MEGAFLO Eco SystemReady Unvented Indirect Hot Water Cylinders

Cylinders for Domestic Purposes Heat Pumps

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS,

Instructions & Maintenance

Vented and Unvented Hot Water Systems

Installation and User Instructions Aquaheat Unvented Water Heaters Models: SS V 50/80 & 100

Instructions for use Installation and Servicing. Solar Hot Water Cylinders/ Flurocyl

UNVENTED MAINS PRESSURE SOLAR WATER HEATERS 100 TO 300 LITRE CAPACITY DIRECT AND INDIRECT MODELS INSTALLATION AND SERVICING INSTRUCTIONS

Hotflo Vertical Litres Installation, operation and maintenance manual

IMPORTANT: PLEASE READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION. PACK CONTENTS

PremierPlus SystemFit Unvented Indirect Hot Water Cylinder Installation and User Manual

AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

StainlessLite Horizontal

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Design, Installation & Servicing Instructions

ADVANCED WATER COMPANY LTD COPPERFORM. Advanced Water Company Ltd. Unvented Hot Water Cylinders. Supplied By Advanced Water Company Ltd

Unvented Copper Hot Water Cylinders

unistor Instructions for Installation and Use Unvented hot water storage cylinder

Installation and Servicing Instructions. Alpha CB50

Stainless ES. Design, Installation & Servicing Instructions. Issue 4

Transcription:

Introduction This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will satisfy the requirements of the Building Regulations (Northern Ireland) 1994 ( the Building Regulations ). There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet. If you prefer you may adopt another way of meeting the requirements of the Building Regulations but you will have to demonstrate that you have satisfied those requirements by other means. Other regulations This Technical Booklet relates only to the requirements of regulation P5. The work will also have to comply with all other relevant Building Regulations. British Standards and European Technical Specifications In this introduction and throughout this Technical Booklet any reference to a British Standard shall be construed as a reference to (a) a British Standard or British Standard Code of Practice; (b) a harmonised standard or other relevant standard of a national standards body of any Member State of the European Economic Area; (c) an international standard recognised for use in any Member State of the European Economic Area; (d) any appropriate, traditional procedure of manufacture of a Member State of the European Economic Area which has a technical description sufficiently detailed to permit an assessment of the goods or materials for the use specified; or (e) a European Technical Approval issued in accordance with the Construction Products Directive, provided that the proposed standard, code of practice, specification, technical description or European Technical Approval provides, in use, equivalent levels of safety, suitability and fitness for purpose as that provided by the British Standard. Products conforming with a European Council Directive Any product designed and manufactured to comply with the requirements of a European Council Directive does not have to comply with any other standard or part of a standard, whether British, International or other, which relates to the same characteristic or specific purpose as the EC Directive. EC marked construction products Any construction product (within the meaning of the Construction Products Directive) which bears an EC Mark shall be treated as if it satisfied the requirements of any appropriate British Board of Agrément Certificate, British Standard or British Standard Code of Practice relating to such a product, where the EC Mark relates to the same characteristic or specific purpose as the Certificate, Standard or Code of Practice. Testing of materials and construction Where for the purposes of this Technical Booklet testing is carried out it shall be carried out by an appropriate organisation offering suitable and satisfactory evidence of technical and professional competence and independence. This condition shall be satisfied where the testing organisation is accredited in a Member State of the European Economic Area in accordance with the relevant parts of the EN 45000 series of standards for the tests carried out. 1

Materials and workmanship Any work to which a requirement of the Building Regulations applies must, in accordance with Part B of the Building Regulations, be carried out with suitable materials and in a workmanlike manner. You can comply with the requirements of Part B by following an appropriate British Standard or you may demonstrate that you have complied with those requirements by other suitable means, such as an acceptable British Board of Agrément Certificate, Quality Assurance Scheme, Independent Certification Scheme or Accredited Laboratory Test Certificate. References Any reference in this Technical Booklet to a publication shall, unless otherwise stated, be construed as a reference to the edition quoted, together with any amendments, supplements or addenda thereto current at 28 February 1994. Diagrams The diagrams in this Technical Booklet supplement the text. They do not show all the details of construction and are not intended to illustrate compliance with any other requirement of the Building Regulations. They are not necessarily to scale and should not be used as working details. Contents Page Section 1 General 3 Section 2 Systems with a storage vessel up to 500 litres and 45 kw 5 Section 3 Systems with a storage vessel over 500 litres or over 45 kw 6 Section 4 Discharge pipes from tundishes 8 Appendix Publications referred to 10 2

Section 1 General 1.1 This Section contains provisions for an unvented hot water storage system. All the components within the system shall be of adequate strength and capable of safely withstanding the temperatures and pressures. Definitions 1.2 In this Technical Booklet the following definitions apply Package an unvented hot water storage system having factory fitted safety devices together with a kit containing pressure and other devices supplied by the package manufacturer, to be fitted by the installer (see Diagram 1.1). Unit an unvented hot water storage system having safety devices and all other devices factory fitted by the unit manufacturer (see Diagram 1.2). 1.3 Limitation on heating sources An unvented hot water storage system shall not be heated (a) directly by a solid fuel heating appliance; or (b) indirectly by a sealed primary circuit which is heated by a solid fuel heating appliance. 1.4 Installation The installation shall be carried out by a person holding a current Registered Operative Identity Card for the installation of unvented hot water storage systems issued by (a) the Association of Installers of Unvented Hot Water Storage Systems (Scotland and Northern Ireland); (b) the Institute of Plumbing; (c) the Construction Industry Training Board; or (d) an equivalent body. Unvented hot water storage system includes a system with an unvented vessel for either (a) storing domestic hot water for subsequent use; or (b) heating domestic hot water as it passes through an integral coil or pipe (eg. water jacketed tube heater or combi boiler). 3

Diagram 1.1 Unvented hot water storage system Package * see para 1.2 temperature relief valve hot water expansion vessel expansion valve heat source with thermostat and thermal cut-out pressure reducing valve with strainer tundish tundish heat source with thermostat and thermal cut-out stop valve water main * check valve Heating can be direct or indirect. This diagram illustrates a typical directly heated system. discharge Package Storage vessel with factory fitted safety devices Kit Diagram 1.2 Unvented hot water storage system Unit * see para 1.2 temperature relief valve expansion vessel expansion valve hot water thermal cut-out thermostat motorised valve pressure reducing valve with strainer primary flow heat source primary return tundish tundish stop valve check valve discharge water main * Heating can be direct or indirect. This diagram illustrates a typical indirectly heated system. Unit 4

Section 2 Systems with a storage vessel up to 500 litres and 45 kw 2.1 This Section contains provisions for an unvented hot water storage system, whether heated directly or indirectly, having a storage vessel which has a capacity of not more than 500 litres and a power input of not more than 45 kw. 2.2 Unvented hot water storage systems An unvented hot water storage system shall (a) have pipework complying with Clause 7 of BS 6700: 1987; (b) be a unit or package which has been certified 2.3 Control on heating sources Devices to control the heating source or sources shall be supplied by the manufacturer as part of the unit or package, and shall comply with paragraphs 3.2 and 3.3. However, an indirectly heated system, which incorporates a boiler, may have the thermal cut out on the boiler. (i) as meeting the relevant requirements of regulation P5 by a member body of the European Organisation for Technical Approvals (EOTA) operating a Technical Approvals Scheme (eg. the British Board of Agrément under MOAT 38: 1986); or (ii) by a certification body having National Accreditation Council for Certification Bodies accreditation as complying with BS 7206: 1990; (c) have controls over the heating source or sources complying with paragraph 2.3; (d) have a tundish or tundishes complying with paragraph 3.6; and (e) have a suitable discharge pipe or pipes complying with Section 4. 5

Section 3 Systems with a storage vessel over 500 litres or over 45 kw 3.1 An unvented hot water storage system, whether heated directly or indirectly, having a storage vessel which has a capacity of more than 500 litres or a power input of more than 45 kw will generally be an individual design for a specific project. The system shall generally comply with Clause 7 of BS 6700: 1987, as qualified by paragraphs 3.2 to 3.6. Safety devices temperature 3.2 An unvented hot water storage system shall have the following safety devices to limit the temperature of the stored water (a) a non self-resetting thermal cut out on each heating source, complying with either (i) BS 3955: 1986; or (ii) BS EN 257: 1992, when the stored water is heated by a gas burning appliance; and (b) one or more temperature relief valves to BS 6283 Part 2: 1991 or BS 6283: Part 3: 1991 which have a total discharge capacity (measured in accordance with Appendix F of BS 6283: Part 2: 1991 or Appendix G of BS 6283: Part 3: 1991) at least equal to the power input to the water. These safety devices shall be factory fitted and located directly on the storage vessel, operate in sequence as the temperature rises and be additional to any thermostatic device fitted to control the temperature of the stored water. 3.3 Where the system is indirectly heated the non self-resetting thermal cut out shall be wired to a motorised valve or some other device which is (a) approved by a member of EOTA; or (b) approved by a body having NACCB accreditation, as being capable of shutting off the flow to the primary heater. However, an indirectly heated system, which incorporates a boiler, may have the thermal cut out on the boiler. 3.4 Pressure devices An unvented hot water storage system shall have the following devices to control the pressure within the system (a) a pressure reducing valve complying with BS 6283: Part 4: 1991; and (b) an expansion valve complying with BS 6283: Part 1: 1991. 3.5 Other devices An unvented hot water storage system shall also have (a) a check valve complying with BS 6282: Part 1: 1982 to prevent the expansion of water to the cold supply; and (b) an expansion vessel complying with BS 6144: 1990 sized to accommodate all the expansion of the water on heating. 6

3.6 Tundishes Each temperature relief valve and expansion valve shall discharge through a metal pipe either individually, or via a manifold, to a tundish incorporating an air break. Where the discharge is individual the pipe size, between the valve and the tundish, shall be not less than the nominal outlet size of the valve. Where a manifold is used it shall be so sized that it can accept the total discharges from the valves connected to it. The tundish shall be located (a) vertically; (b) not more than 500 mm horizontally from any valve discharging to it; (c) where it can be readily seen but not create a hazard; and (d) in the case of a temperature relief valve in the same space as the storage vessel. The tundish shall be connected to a discharge pipe complying with Section 4. 7

Section 4 Discharge pipes from tundishes General 4.1 A discharge pipe from a tundish shall (a) be of metal; (b) be at least one pipe size larger than the outlet from the safety device or manifold discharging to the tundish; (c) be no longer than the equivalent in hydraulic resistance of a straight 9 m length of pipe unless its size is increased in accordance with paragraph 4.2; (d) have a vertical section of not less than 300 mm long below the tundish before any elbows or bends in the pipework (see Diagram 4.1); and (e) have a continuous fall. 4.2 In calculating the hydraulic resistance of a discharge pipe the resistance of straight lengths, elbows and bends shall be taken into account. Visibility of discharge 4.3 The discharge from a safety device which may consist of scalding water and steam, shall be visible at the tundish and shall also be visible at the final point of discharge. 4.4 Acceptable discharge arrangements include (a) below a fixed louvred grating and above the water seal in a trapped gully (see Diagram 4.1); or (b) downward discharge at low level but no less than 100 mm above external surfaces and having a wire cage or suitable guard to prevent contact. Where a number of discharge pipes are grouped together each discharge pipe shall be marked to make the system which is discharging readily identifiable. If a discharge pipe is of copper its size shall be calculated using the values given in Table 4.1 and the method shown in the worked example. 8

Diagram 4.1 Typical discharge pipe arrangement see paras 4.1 4.4 safety device (eg. temperature relief valve) metal discharge pipe (D1) from temperature relief valve to tundish tundish 500mm maximum 300mm minimum metal discharge pipe (D2) from tundish, with continuous fall, see Table 4.1 and worked example discharge below fixed grating or as para 4.4(b) fixed louvred grating trapped gully Table 4.1 Sizing of copper discharge pipe D2 for common temperature relief valve outlet sizes Valve Minimum Minimum Maximum resistance Resistance outlet size of size of allowed, expressed created by size discharge discharge as a length of each elbow pipe D1* pipe D2* straight pipe (ie. or bend from tundish no elbows or bends) 22 mm up to 9 m 0.8 m G 1 2 15 mm 28 mm up to 18 m 1.0 m 35 mm up to 27 m 1.4 m 28 mm up to 9 m 1.0 m G 3 4 22 mm 35 mm up to 18 m 1.4 m 42 mm up to 27 m 1.7 m 35 mm up to 9 m 1.4 m G1 28 mm 42 mm up to 18 m 1.7 m 54 mm up to 27 m 2.3 m * See paragraphs 3.2(b), Section 4 and Diagram 4.1 Worked example The example below is for a G 1 2 temperature relief valve with a discharge pipe (D2) having 4 No. elbows and length of 7 m from the tundish to the point of discharge. From Table 4.1 Maximum resistance allowed for a straight length of 22 mm copper discharge pipe (D2) from a G 1 2 temperature relief valve equates to: 9 m Subtract the resistance for 4 No. 22 mm elbows at 0.8 m each = 3.2 m Therefore the maximum permitted length equates to: 5.8 m. 5.8 m is less than the actual length of 7 m therefore calculate the next largest size. Maximum resistance allowed for a straight length of 28 mm pipe (D2) from a G 1 2 temperature relief valve equates to: 18 m Subtract the resistance for 4 No. 28 mm elbows at 1 m each = 4 m Therefore the maximum permitted length equates to: 14 m As the actual length is 7 m, a 28 mm (D2) copper pipe will be satisfactory. 9

Appendix Publications referred to BS 3955: 1986 Specification for electrical controls for household and similar general purposes. AMD 5940, December 1988 BS 6144: 1990 Specification for expansion vessels using an internal diaphragm, for unvented hot water supply systems. BS 6282: Devices with moving parts for the prevention of contamination of water by backflow. Part 1: 1982 Specification for check valves of nominal size up to and including DN 54. BS 6283: Safety and control devices for use in hot water systems. Part 1: 1991 Specification for expansion valves for pressures up to and including 10 bar. Part 2: 1991 Specification for temperature relief valves for pressures from 1 bar to 10 bar. Part 3: 1991 Specification for combined temperature and pressure relief valves for pressures from 1 bar to 10 bar. Part 4: 1991 Specification for drop-tight pressure reducing valves of nominal size up to and including DN 50 for supply pressures up to and including 12 bar. BS 6700: 1987 Specification for design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages. BS 7206: 1990 Specification for unvented hot water storage units and packages. BS EN 257: 1992 Mechanical thermostats for gas-burning appliances. British Board of Agrément MOAT 38: 1986 The Assessment of Unvented Hot Water Systems and the Approval and Surveillance of Installers. 10